Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | ₹12.6 L Quoted ₹13.1 L | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER |
| 2 | L2₹13.6 L+₹49,799 (3.80%)Rejected-AOC M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | ₹13.6 L+₹49,799 (3.80%) | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 3 | L3₹17.2 L+₹4.1 L (31.2%)Rejected-AOC 3RD FLOOR VVIP RESIDENCY MAHINDER VIHAR CHAKRATA RD NEAR RAMADA HOTEL DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹17.2 L+₹4.1 L (31.2%) | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 4 | L4₹20.5 L+₹7.4 L (56.4%)Rejected-AOC | ₹20.5 L+₹7.4 L (56.4%) | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
10 Sept 2022, 6:00 pmClosed
GE I RNDDEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
REPAIR/ MAINTENANCE OF SUBMERSIBLE, CENTRIFUGAL PUMPS MOTORS MS COLUMN, STARTER LT PANEL, PROTECTION DEVICE, IT CONNECTION CLEANING OF WATER TANK AND WATER LEVEL INDICATORS PUMP HOUSE AT TECH AND RESIDENTIAL AREA AT CQA (I) UNDER GE (I) RND DEHRADUN
2022_MES_545239_1
GE(I)RND/9173/E8/22-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DEAL DEHRADUN
Class E Category a(ii) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I R N D DEHRADUN
₹40,000
Yes
15 Oct 2022
13 Aug 2022
12 Sept 2022
13 Aug 2022
10 Sept 2022
27 Aug 2022
13 Aug 2022 - 27 Aug 2022
Amount
Disconnecting and removing the water and electric connections carefully from the existing submersible pump sets of any capacity, any size,any make and taking out the submersible pump set of alongwith column pipe 100 mm dia,electric cable and fittings of bore well or strip opening the pump set (approximately 450 feets depth of pump set from GL) and taking out the pump set alongwith pipes and fittings for flushing the bore well or strip opening the pump set for repairs, replacement of worn out spares, fixing of serviceable spares assembling the pump set completely, testing of pump set, lowering the pump set inside the bore well after repairs, including connecting back the water and electric connections, Commissioning of pump set for satisfactory operation on its full load complete., all as specified and directed. NOTES :- 1. Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost. 2. Number of column pipe may vary from 30 to 50, The existing pipes & flanged joints shall be checked for its serviceability & unserviceable joints alongwith flanges shall be removed from the column pipe by cutting the pipes & making new thread in pipes for fixing of new flange joint, the cost of same shall be deemed to be included in the quoted rate for above item. However cleaning of pipes if any required shall be measured & paid separately. 3. Expendable stores like cotton waste/cleaning materials lubricants , gland packing metal filling, machinaing and transportation to and fro from site to work shop are deemed to be included in rate quoted. 4.The spares required for repair the pump sets,motor,MS pipe,MS Nut& botls ,rubber gasketjoints and rewinding of motors shall be measured and paid for separately as supply only under appropriate items of Schedule ‘A’. 5. Labour elemetns is included in unit rates.
Opening the pump and motor for inspection, repairs and reassembling the pump and motor as per the original assembly after repairs/ replaceing the wourn out unserviceable parts with new parts as ordered (the parts including cleaning replacing the minor items like, packing bolts, nuts and washers and MS clamps etc) making the pump and motor fully serviceable including machining etc and testing the both after refixing duly testing and commissioning all as specified and directed by the E-in-Charge for 35 to 52 HP capacity, 3 phase, 415 volts, 50 HZ, AC supply, pumps & motors of make KSB / SU / CALAMA. complete, all as specified and directed. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under these items. (ii) Burnt out windings of motor shall be replaced, measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include transportation to & fro of pumps/ motors to workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at workshop. (iv) The rate quoted for the item shall include re-metaling of Pump shaft, polishing and grinding and making standard size to match with Gun Metal Bush/Neck-ring. (v) Lifting of pump and motor from bore well and lowering of pump and motor after repairs shall be measured and paid separately under appropriate item of Schedule `A' (vi) The quoted rate shall be deemed to include replacement of small/ minor parts i.e. washers, keys for coupling, cable packing ring etc.
Supply only following items / spare parts suitable for AC submersible pump set of 35 to 50 HP capacity dismantled / fixed under Sch ‘A’ item No. 2 here in above complete, all as specified and directed.
Cast iron stage bowl
Gun metal neck ring
Anti magnetic stainless steel pump shaft with key
Gun metal impeller
Stainless steel sleeve (Inlet)
Stainless steel sleeve (Outlet)
Running bush out let of Gun metal
Stage bowl cover
Bolt stud with nut and washers
Running bush inlet of Gun metal
Strainer stainless steel
Shaft nut with washer
Supply only the following items / spare parts suitable for Motor of AC submersible pump of 35 to 52 HP capacity dismantled/fixed under Sch ‘A’ item No. 2 here in above complete, all as specified and directed.
Stainless steel sleeve DE and NDE.
Connector for motor
Steel bolt
Key for thrust plate
Bush bearing (Set of two)
Thrust bearing (Set of two)
Cable pressure washer
T-bolts with nuts
Bearing bush rubber
Thrust Plate
M & L for rewinding the motor with PVC insulated copper conductor of same guage weight and tuns to achieve its full efficiency inclduing tying the windings and connecting the coils and brining the connections as that of exisitng complete, all as specified and directed for submersible motor of following capacity:-
40 to 60 HP, Three phase, 415 Volts, 50 Hz, AC supply
Supply only 35 Sqmm, 3 Core, flat submersible Cable, PVC insulated, PVC sheathed with multi-stranded copper conductors, conforming to IS : 694- 1990 of 1100 Volt grade,dismantled/fixedunder Sch ‘A’ item No. 1 above complete, all as specified and directed.
Supply only straight through joint complete with jointing materials suitable for three core stranded copper conductor cable PVC insulated and sheathed flat submersible cable 1100 Volt grade of size 35 Sqmm complete, all as specified and directed
Supply only MS water tubing as in column pipe, 100mm bore, medium grade of thickness 4.5mm, ISI marked, conforming to relevant IS for column pipe in required length but length not more than 3.00 mtr, both end flanged 8mm thick flange internally threaded and duly welded with pipe using 4 Nos MS strips of size 20x 3mm in triangular right angled shape with provision of 04 Nos holes and side slot for passing submersible cable on both flanged end, including painting with two coats of anti corrosive bituminous paint over a coat of red oxide primer complete, all as specified and directed . (MAKE : TATA/TT SWASTIK/JINDAL )
M & L for scrubbing out rusted MS pipe of 100 mm bore with wire brush to remove rust, dirt etc. preparing the surface and applying a coat of anti corrosive bituminous paint complete, all as specified and directed by Engr-in-charge.(length of pipes shall be 3.00 meter ).
Supply only rubber gasket joints in flanged end MS/ cast iron pipes and fittings complete with and including minimum 3 mm thick rubber/fibre gasket and necessary nuts/bolts/washers all as specified and directed for following sizes in replacement :-
100 mm bore
150 mm bore
Disconnecting & taking out the existing defective Oil immersed star delta starter of any description, any capacity and in any position, 3 phase, 415 volts, 50 Hz suitable for AC supply submersible pump set upto 80 HP (Make : Jyoti) and strip opening of Star delta starter, taking out unserviceable/defective wiring & parts, cleaning and servicing complete including replacement of unserviceable parts and copper wiring with new one of existing size, reassembling, fixing in position, making connections and testing complete, all as specified and directed Notes :- (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch ‘A’ as supply only but fixing charges of the parts replaced/repaired is deemed to be included in these item (ii) Transformer oil shall be drained out and collected in contractors own containers and reused after heating and filtration through filtration plant to achieve the dielectric strength/insulation value upto 40 KV and filling shall be included in the rate quoted by the contractor for above items. (iii) Fresh transformer oil required for top up shall be measured as “supply only” but its heating and filling shall be included in the rate quoted by the contractor for above items.
Supply only the following items / spare parts suitable for star delta starter of capacity upto 50/60 HP capacity dismantled/fixed under Sch ‘A’ item No. 11 here in above complete, all as specified and directed.
Fixed contact ’ (Set of 24)
Moving contact ’ (Set of 12)
Cam spring
Lever spring
Over load coil
No volt coil 415 Volts AC
Supply only transformer insulating oil EHV grade having dielectric strength not less than 40 KV (R.M.S) at 4mm gap high viscosity in transformer confirming to IS – 335 of 1983 for filling under Sch ‘A’ item No. 14 here in above complete, all as specified and directed Make:- BPCL/HPCL/IOC/SAVITA /POWEROIL
Supply &Fixing in Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete, all as specified and directed.
Supply ,fixing,testing and commissioning in replacement of unserviceable submersible pump NRV from any position complete and Supply and fixing of submersible pump NRV for 100mm dia column pipe, suitable for 35 to 50 HP capacity pumps as per existing model of Make SU/Calama/KSB designed for vertical fitting complete, all as specified and directed.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick masonry including finishing the surfaces even and smooth without using extra cement complete, all as specified and directed.
M&L for providing cement concrete 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in copings, holdfast and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete, all as specified and directed.
M & L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth block for support of pipe including form work weathering slightly chamfered angle and throating with and including necessary form work and finished concrete surface even & smooth without using extra cement complete, all as specified and directed.
M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6 mtr mean radius, old size brick built in Cement Mortar (1:4), for manholes complete, all as specified and directed.
Supply, fixing, testing & commissioning in replacement of unserviceable MCCB 250Amps Triple pole, 415 volts, 50 Hz having breaking capacity 35/36 KA , with fixed thermal magnetic setting complete, all as specified and directed Make: Cat part No: 420249 of Legrand or equivalent in Siemens/ Havells
Supply, fixing, testing & commissioning in replacement of unserviceable Power Contactor ML-4 type, 3 pole, coil voltage 415 / 440 Volts, 50 Hz with 2 NO + 2 NC auxiliary contacts, having current rating (AC3) of 70 Amps at 415 volts complete, all as specified and directedCat part No :- SS 90910 of make L&T or equivalent model in specified make as approved by GE.
Supply, fixing, testing & commissioning in replacement of unserviceable change over switch and Supplying, Fixing, jointing and testing OFF LOAD change over switch, 4 pole, 415 volts of current rating 200 Amps, in and including sheet metal enclosure, side handle operated conforming to IS : 13947 ( Part I & III ) complete, all as specified and directed
Material and labour for repair to run lead joints including caulking properly with using old retrieved lead from taking up or down pipes but with and including using new spun yarn for the following sizes of CI pipes/fittings etc complete, all as specified and directed. Notes : (i) Earth work in excavation, returning filling in and removal shall be measured and paid separately. (ii) Additional quantity of lead & lead wool, if any required, for making new joints other than the quantity of lead retrieved from taking up / down pipes, shall be measured and paid for separately as ‘’supply only’’ under appropriate item of Schedule `A'
150 mm bore
100mm bore
Supply only pig lead of best quality conforming to IS : 782 – 1978 for providing lead joints complete, all as specified and directed
Supply only lead wool of best quality conforming to relevant IS for providing lead joints complete, all as specified and directed
Disconnecting,removing the water ,electric connections and taking out carefully the old existing defective electric motor, 7.5 HP of booster pump / centrifugal pump of any description and in any position, dismantling and strip opening of the motor, removing the old existing burnt windings, cleaning the slots & rewinding of the electric motor 7.5 HP, operating on 415 V, 3 Phase, 50 Hz AC supply with existing gauge super enameled copper wire, including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeves insulating varnish etc for powering multistage booster pumps/ centrifugal pumps & testing at workshop and transportation to site & refixing on existing platform complete, all as specified and directed by Engr-in-charge.
All as per item No. 26 here in above but motor of capacity 10.0 HP complete, all as specified and directed.
Disconnecting, removing the water, electric connections and taking out carefully defective booster/centrifugal pump of capacity 7.5 HP, DSM model of Make Kirloskar,, three phase, 415 V, AC supply and carrying out necessary repairs and replacement of bearing bush, gland plate, impeller, nuts and bolts etc, any trasportation to workshop if required, Repair to bearing housing with metling and turning and fixing the same in position and testing on full load complete, all as specified and directed
All as per item No. 28 here-in- before but booster pump / centrifugal pump of capacity 10 HP complete, all as specified and directed
Supply only the following items/spare parts suitable for centrigugal pump of capacity 7.5/10 HP dismantled/fixed under Sch `A` item No 59 and 60 here in above complete, all as specified and directed.
CI impeller as per existing size
MS stud with nut for split body complete size as per sample
Ball bearing for driving and non driving end.
CI sleeve of DE / NDE
CI/MS gland packing plate
CI bush (stuffing box bush)
Pump shaft EN8 complete including making key groove with check nut
Set of key with nut & washer
Replacement of packing sheet
Supply and fixing in replacement of unserviceable water gauge of range 0-100 psi, 100mm dia in delivery line with in incluing socket welding in pipe line complete, all as specified and directed
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep in soft/loose soil including forming sides and bottom surface to required levels/slops/gradients etc. complete, all as specified and directed by Engr-in-charge Note:- The disturbed surface of roads/paths/plinths etc. shall be repaired and quoted rates deemed to include this aspect.
Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete, all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete, all as specified and directed.
Taking up or down old existing GI tubing and connections, including connected fittings/ accessories and fixtures of any description/ grade and in any position in trenches/under floors/road / floor /duct on walls etc and including cleaning for reuse if serviceable or unserviceable to be removal to store complete, all as specified and as directed by Engr-in-charge(Note:- (i) Earth work in excavation, returning filling in and removal under appropriate items of Schedule ‘A’ for the following bore of pipes:-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply, laying, connecting & testing of galvanised iron water tubing 'medium grade' conforming to IS-1239 with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc as required complete fixed to walls and ceilings, laid in trenches/under floor/under road or floors complete,(Note:-(i) Earth work in excavation, returning filling in and removal complete all as specified and directed by Engr-in-charge for the following bore of pipes :-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Re-laying, jointing & testing of old serviceable galvanised iron water tubing 'any grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc as required complete fixed to walls and ceilings, laid in trenches/under floor/under road complete all as specified and directed for the following sizes :- (Note:- Old pipe will be obtained from sch 'A' item No- 41 of taking down. Earth work and additional GI fitting will be measured and paid separetely under respective item of sch "A")
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply, fixing and testing in replacement of unserviceable Gate valve/Globe valve and Supply, fixing, jointing and testing, of gun metal globe or gate valve with iron wheel head, both ends screwed for iron pipe, conforming to IS 778 complete, all as specified and directed for following bore of pipes :- (Make: Sant/Bir/ Leader/Upadhaya)
20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
Taking out or down defective sluice valve from main line and opening carefully old defective sluice valve of any description and in any position for and including servicing, over-hauling / greasing etc, and replacement of old unserviceable / worn out parts and reassembling the sluice valve after repair and refixing the same & testing after installation complete, all as specified and directed for following bores :- Note :- (i) The cost of Earth work, joints & jointing materials washers, gaskets and minor parts shall be deemed to be included in the quoted rates but Replacement of the defective parts i.e. cast iron gate & stainless steel spindle of Sluice valve shall be measured and paid for separately as supply only under appropriate items of Schedule ‘A’
200 mm bore
150 mm bore
100 mm bore
80 mm bore
Supply only stainless steel spindle, heavy duty, threaded, with and including one gun metal check unit suitable for sluice valves of any description dismantled/fixed under Sch `A` item No 108 here in above complete, all as specified and directed by Engr-in-charge for following bores :-
150 mm bore
100 mm bore
80 mm bore
Supply, installation, fixing, jointing and testing in replacement of unserviceable cast iron sluice valve of class PN-1 both ends flanged with iron wheel head and stainless steel spindle, short body type, conforming to IS-14846 of 2000 including rubber gasket and nut blot with washer for flange joints complete, all as specified and directed for following bores :- Notes:- The cost of Earth work, joints & jointing materials of the sluice valve shall be deemed to be included in the quoted rates.
200 mm bore
150 mm bore
100 mm bore
80 mm bore
M & L for cleaning/ scraping of steel/ cast iron surfaces of existing dull painting of Valve pit chamber inner pipe lines and valves etc and applying two coats of synthetic enameled paint over a coat of red oxide primer by spray machine complete, all as specified and directed Note : The Chamber, valves, connected pipe line etc. shall be painted according to colour code specified as per IS Instructions and as directed by Engr-in-Charge at site.
M&L in replacement of unserviceable Indicator lamps of any size & capacity after disconnecting all the electrical connections and supplying, fixing connecting and testing Indicator lamps neon type suitable for 220 volts 50Hz, AC supply including wiring with 1.5 Sqmm PVC insulated stranded copper conductor cable complete, all as specified and directed(Make : L&T/BCH/Rishab )
M&L in replacement of unserviceable volt meter of any description and supply, fixing, connecting and testing Digital type of size 96mm x 96mm, AC Volt meter 500 Volts including wiring with 1.5 Sqmm PVC insulated stranded copper conductor cable complete, all as specified and directedMake : DENKO/ESCORP/AE
M&L in replacement of unserviceable Amp meter of any description alongwith CT’s and supply, fixing, connecting and testing Digital type of size 96mm x 96mm, AC Amp meter 200 Amps with including 3 Nos C.T of Ratio 200/5 of class-1.0 including wiring with 1.5 Sqmm PVC insulated stranded copper conductor cable complete, all as specified and directed by Engr-in-charge.Make : DENKO/ESCORP/AE
Supply, laying, jointing and testing in replacement of unserviceable DI/CI pipe by new one ductile Iron Pipe with spigot socketed ,heavy duty including specials and rubber tyton joint ring, laid in trenches,or floor/under road complete, all as specified and directed by Engr-in-charge for the following bore: Note:- Earth work in excavation, returning filling in and removal & joints shall be measured and separetely under appropritate of sch "A")
200 mm bore
150 mm bore
100 mm bore
Supply, installed, jointing and testing in replacement of unserviceable non return valves of cast iron non return valve both ends flanged complete all as specified and directed for following bores :- Notes:- (i) The cost of Earth work, joints & jointing materials of the non return valve shall be deemed to be included in the quoted rates.
150 mm bore
100 mm bore
M&L for cleaning and disinfecting of RCC OH tank of 1,00,000 gallon capacity upto 21 Mtr staging, of any shape by initially cleaning the external area and the entry man hole with skilled manpower with protective clothing and apparatus etc and approved electrically operated equipments including all tools, tacles and labour equipments e.g. electric machines, pumps (including desludging pump), pressure water jet, sludge removal etc. required for completion of the work in all respect by specialized water tank cleaning process as under: (i) Dewatering of over head tank by drain out pipe. (ii) Mechanized removal of all remaining dirty water by high capacity pump set. (iii) Removal of sludge by vacuum operated Pump. (iv) Cleaning of walls, ceiling and bottom of tank by high pressure rotary jet 120 bars pressure. (v) Removal of all dirty particles by industrial wet vacuum cleaner leaving the tank 99.9% physically cleaned. (vi) Sterilization of tank by Echo-Friendly biodegradable and highly effective anti bacterial non toxic agent approved by NTC (National Toxicology Center) against all pathogens agent of tank clean. (vii) Sterilization of tank atmosphere by industrial UV radiator leaving the tank complete sterlite by specialized method (viii) After complete treatment is carried out, all inlet, over flow, delivery, wash out pipes, ladder and doors shall be painted with two coats of synthetic enamel black paint after thorough cleaning the surfaces and also the surfaces of sluice valves shall be painted with P.O. Red paint and writing " capacity of tank, date of cleaning and due date of cleaning" on wall as specified and as directed. Notes: (i)The work will be got executed from the reputed specialized water tank cleaner as approved by GE. (ii) All the sludge materials / fungus removed from the underground sump / semi underground sump and over head tanks will be removed outside defence land from the site. (iii) All underground sump / semi underground sum and overhead tanks will cleaned in all respect upto 3 mtr around the water tanks. (iv) All T & P required for the cleaning of tanks / Sumps will be arranged by the contractor. (v) The wire mesh of ventilations of the tank shall be replaced with new mesh. (vi) The cost of the same shall be deemed included in the respective items.
All as per item No 130 here in above but RCC OH tank of capacity 30,000 gallon complete, all as specified and directed by Engr-in-charge.
All as per item No 130 here in above but RCC OH tank of capacity 25,000 gallon complete, all as specified and directed by Engr-in-charge.
Supply, installation, testing and commissioning in replacement of unserviceable electronic auotmatic phase sequence corrector device working on IC based technology, capable to correct disturbed pahse sequence, prevent the motor from reverse rotation, ptotect motor from phasing, low / high voltage cut with time delay between 350 Volt to 480 volts with 60 second delay, protection against unbalanced load of two phase out of three phase supply system withnout Contractor and box complete all as specified and directed Make as approved by GE.
Disconnecting and taking out single head geared electrcally operated motored Dosing pump, Model No:- 96NGQ51 of DECRIN (Declibac Technologies Privte Limited) (for calcium based granular disinfectant for water treatment system) for servicing and repairs cleaning all parts and checking for any defect, pump is operated by 1/30 HP, 230V, AC operated, 44 RPM, adjustable pressure range from 0 to 100 PSI and adjustable discharge range from 2.0 Gallons per day to 40.0 Gallons per day inclusive of Tubing for suction and discharge, connecting nuts, injection Check Valve, ferrule, Clay Weight, ferrules etc. & refixing on existing frame, and ,testing after repair complete, all as specified and directed. Notes : (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch `A` as supply only but fixing charges of the parts replaced/repaired is deemed to be included in the above quoted rates.
Supply only the following items/spare parts suitable for Dosing pump (for calcium based granular disinfectant for water treatment system) dismantled/fixed under Sch `A` item No 135 here in above complete, all as specified and directed by Engr-in-charge.Note: Contractor should visit adn note down suitable parts of the dosing pump before quoting the rate. Make of the parts should be one of the make approved by E-in-C, Branch
ROTOR ASSEMBLY WITH BEARINGS BRACKETS & TOLERANCE RINGS. Cat Pt No. PMBRPL2 of DECRIN (Declibac Technologies Privte Limited)
COIL 250V 50HZ Cat :MP6J222 of DECRIN (Declibac Technologies Privte Limited)Coil 250V 50Hz
Single Head feed rate control with shaft
Pump head (Ferrules 1/4"& Duckbill included)
Roller Assembly
Pump Tube
Injection check valve 3/8"
Weighted suction line strainer 3/8"
3/8" White suction / Discharge tubing
Check valve duckbill only
Connecting nut 3/8"
Connecting nut 3/8" with adapter
Ferrule 1/4"
Altoch Dosing System ( Modal ADS-1) consisting 100 ltrs FRP tank with level gauge agitetor motor and shaft with impiller
Supply, laying, jointing and testing in replacement of unserviceable CI/DI pipes specials of any size and any type complete of size upto 200mm dia , bend , Y junction , Tee, reducer, tail piece, spigot socketed/ spigot flanged/ flanged end/ plain end any type as required at site and as laid in trenches,or floor/under road complete, all as specified and directed Note :- Earth work in excavation, returning filling in and removal & joints shall be measured and paid separately under appropriate items of Schedule ‘A’
Disconnecting and removing the water and electric connections carefully from the existing water fountain and nozzles, cleaning of fountain sump and repair the water connection and supply of sprinkler of suitable size for 15/20mm size tubing including 03 Nos fountain lights with all electric connection to enable the complete system complete, all as specified and directed
Disconnecting and removing the water and electric connections carefully from the existing water fountain and nozzles, cleaning of fountain sump and repair the water connection, Submersible pump 2/3 HP capacity and supply of nozzles of suitable size for 15/20/25mm size tubing including 03 Nos fountain under water lights with all electric connection to enable the complete system,testing and commissioning complete, all as specified and directed by Engineer-in- Charge.
Supply only Calcium based granular disinfectant for water treatment, more stable than chlorine gas, and stronger than Bleaching powder and sodium hypo chloride, packing in 45 Kg Plastic drums. Make and brand as per approved list of E-in C,s branch,AHQ New Delhi .
Labour only for checking the serviceability of the pipe line of any description and fixed in any position & replacement of un-serviceable/damaged/ broken parts either in single or in combination, dismantling and re-assembling the pipe fittings and making the pipe lines serviceable, fixing the pipe fittings in position, connecting to water supply and its testing on installation complete, all as specified and directed, by Engr-in-charge by emplooying one plumber and one helper (Unshild) by receving complaint slip from MES service centre and returning the same after completion the job to MES authority complete, all as specified and directed here in after in notes. NOTES :- (i) Replacement of parts i.e nipple, union, elbow, bend, reducer & etc for 15/20/25/40/50mm GI pipe fittings, if any required at site, shall be measured and paid for separately under appropriate item of Schedule `A' as ‘supply only. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the pipe fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of pipe fittings of any description on walls / ground etc i.e. in any position at site. (iii) Required parts ie. thread/ adhesive etc and other minor items excluding the required spares parts for repairing and making the water supply line in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. (iv) Contractor’s quoted rates is deemed to include for inspection/checking the serviceability of the pipe line removing the damaged unserviceable / broken parts, fixing the new parts as
Supply only the following parts for Water supply GI fittings complete, all as specified and directed.
Union 15mm bore
Union 20mm bore
Union 25mm bore
Union 40mm bore
Union 50mm bore
Union 80mm bore
Elbow 15mm bore
Elbow 20mm bore
Elbow 25mm bore
Elbow 40mm bore
Elbow 50mm bore
Nipple 15mm bore and of any length upto 150mm
Nipple 20mm bore and of any length upto 150mm
Nipple 25mm bore and of any length upto 150mm
Nipple 40mm bore and of any length upto 150mm
Nipple 50mm bore and of any length upto 150mm
GI socket 15mm bore
GI socket 20 mm bore
GI socket 25 mm bore
Reducer 15X 20 mm
Reducer 15X 25 mm
Reducer 20X 25 mm
Reducer 25X 40 mm
Reducer 40X 50 mm
Tee 15mm bore
Tee 20mm bore
Tee 25mm bore
Tee 40mm bore
Tee 50mm bore
Tee 15 x20mm bore
Tee 20 x25mm bore
Tee 15 x25mm bore
Tee 25 x40mm bore
Tee 40 x50mm bore
M & L for cleaning/ scraping of steel/ cast iron surfaces of existing dull painting of pump/motor of 7.5/10/15/20HP capacity & pipe in side PH building upto 150mm dia & appx 5 RM connecting pipe lines and valves etc. and applying two coats of synthetic enameled paint over a coat of red oxide primer by spray machine complete all as specified and directed. Note : The pump/motor, valves, connected pipe line etc. shall be painted according to colour code specified as per IS Instructions and as directed at site.
Supply,Installation,testing & commissioning in replacement of unserviceable automatically water level indicator system comprising with the following accessories, including making necessary connection for controlling/ maintain the water level indicator automatically complete,all as specified and directed by Engr-in-Charge :- (i) Water controlling automatic system with sutitable size/cap of pump off/on and indicator with timer contractor relay in box for syncoring, Make : BPB. -01 Nos. (ii) Suitable capacity of Senser for 100% filling and position for motor on/off.- 01 Nos (iii) Senser for 30% filling and position for motor on/off . -01 Nos (v) Suitable size of Wire 4 pair and 8 wire .-170 RM (vi) Wire 1.5 Sqmm 3 Core (For Senser.).-25 Mtrs
M & L for fabrication of Installation sign Board of size 900 X 600 made out of 3 mm thick MS sheet and position the same on 50 X 50 X 6 mm Angle iron frame & fixing on 2 Nos posts made out of 40mm dia medium grade GI pipe up to 150 cm height ( 105 cm above the ground level and 45 cm below the ground level) with necessary fixing arrangements such as bolts, nuts and washers incl painting the sign board except GI posts with one coat of red oxide paint and two coats of synthetic enamel paint over the primer & pasting of retro refactive High intensity Grade (HIG) 3 mtr blue sheet over the PGI sheet with white 0.5 incl border and weiting of information over board by cutting and pasting of letters, complete all as specified and directed by Engr-in-Chaarge. Make of PGI Sheet : TATA/SAIL Note :- Information for pasting is approved by GE, all material and cutting ,pasting is deemed to be included in the rates quoted by the contractor in above respective item.
Supply,Installation,testing & commissioning in replacement of unserviceable LED Aviation obstruction lights, fitting of any pattern any description and in any position complete comprising of die cast aluminium alloy housig, finished in avaitation yellow colour, polycarbonate enclosures in red colour , with and including 302 Nos LED and accessoried fixed on over head reservior complete all as specified and directed. Cat part No:- BGAV 302 LED of make Bajaj or equivalent model in specified make as approved by GE. Note :- Rate for any preparatory works, T&P and other resources required for dismantling /repair/ fixing of aviation obstruction light,etc on the top of OHR at the height of 20 to 25 m from Ground level is deemed to be included in the scope of above item.
Supply, laying, jointing and testing in replacement of unserviceable bib taps for 15mm bore pipe chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete, all as specified and directed by Engr-in-charge
Supply, laying, jointing and testing in replacement of unserviceable bib taps for 20mm bore pipe chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete, all as specified and directed
M & L for Cutting of the existing 80/100 150 mm bore of GI/ CI pipe line for rectifying leakage and reducing to required length, in position, for insertion of collars or Tee & other fittings including dewatering etc complete all as specified and directed. Note :- CI fittings, jointing materials and earth work shall be measured and paid separately. How ever cost of dewatering is included in the quoted rates.
Supplying,fixing,testing and commissioning in replacement of LT distribution Panel (CPRI appproved) Cubicle type IP-56,outdoor type factory /fitting fabricated made out of 3 mm thick CRCA sheet outer & 2 mm thick CRCA sheet inner of suitable size to accommodate all accessories / fitting, compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC /epoxy insulators having provision for termination of incoming and outgoing cables. All extension liks/ interconnection shall colour coded sleeves. The cubicle shall have frame work, bottom & 45 CM long 4 legs of size 50 x50 x 6 mm angle iron, grouted in PCC 1:3:6 as directed by Engr-in-charge. A detachable gland plate of thichness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, The panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY STRYCTURE after seven tank phosphate treatment, front & back opening type and fixing 2 Nos danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following :- ( NOTE : - LT Panel board should be as per IS/ICE 61439-Part-I & II Type Test certificates for 4000 Amps with Breaking capacity not less than 65 KA. Panel Builder should submit all Certificates before the drawings approval.) Make of Panel boards :- Legrand, L & T, Shalabh (India) Industries & Bright Panels As Incomer :- (a) Bus bar TPN, Aluminium, 600 Amps - 01 Set. (b) 400 Amp FP Thermalmagnetic release adjustable MCCB with a breaking capacity of 36 kA with Ics= Icu 100%, along with suitable spreader links = 01 No. (Make :- L&T/Legrand/AE/SIEMENS) (c) Digital type multy function meter to measure V.A.F PF with suitable CTs = 01 set. (Make :- L&T/Legrand/AE/SIEMENS). (d) LED type Phase indicator lamp ( RYB) = 03 Nos. As outgoing:- (a) 200 Amps TP Thermal magnetic release adjustable MCCB with a breaking capacity of 25 KA with Ics=Icu 100%, along with suitable spreader links = 02 Nos. (Make :- L&T/Legrand/AE/SIEMENS). (b) 100 Amps TP Thermal magnetic release adjustable MCCB with a breaking capacity of 25 KA with Ics=Icu 100%, along with suitable spreader links = 02 Nos. (Make :- L&T/Legrand/AE/SIEMENS).
All as above item No 198 but indoor type fabricated with 2 mm thick CRCA sheet APFC Panel,30 KVAR with the following :- As incomer :- (a) Bus bar TPN Aluminium 150 Amps = 01 Set. (b) 100 Amps TP Thermal magnetic release adjustable MCCB with a breaking capacity of 25 KA with Ics=Icu 100%, along with suitable spreader links = 02 Nos. (Make :- L&T/Legrand/AE/SIEMENS). (c) Digital type multy function meter to measure V.A.F PF with suitable CTs = 01 set. (Make :- L&T/Legrand/AE/SIEMENS). (d) LED type Phase indicator lamp ( RYB) = 03 Nos. As outgoing:- (a) MCB TP 32 Amps,10KA - 02 Nos. (b) MCB TP 16 Amps,10 KA - 02 Nos. (c) Capacitors, Heavy duty,cylindrical type,480 V with Capacitor duly contactor of conbination size 10 KVAR - 02 Nos & 05 KVAR - 02 Nos. (d) APFC Relay 04 stage with suitable CTs - 01 No. (e) Auto Manuual switch -01 No. (f) ON-OFF Push button - 008 NOs. (g) ONindicator - 04 Nos. (h) Axial flow fan 150 mm, thermostate controlled - 01 No. Note for item No. 69 & 70 : (i) The contractor shall submit proposed drawing of the panel interlia mentioning make of switchgears to be incorporated alongwith name of panel manufacturer for approval of GE before manufacturing. (ii) The quoted rate is inclusive of the cost of danger notice plate of suitable size and marking of letters with PVC sheet/ Stickers such as incoming and outgoing and capacity of breakers etc. (iv) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (v) The bottom of panel shall have minimum 45cm height from existing ground / floor level. (vI) Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job (vii) Interconnection of busbar with MCCB, SFUs, contactor with suitable size aluminium strip - 01 Job
Supplying, laying, jointing and testing single core PVC insulated, unsheathed stranded copper conductor cable of size 25 Sqmm of voltage rating upto 1100 Volts complete all as specified and directed.
Collecting the sample of water from each source "bore well" and testing the sample for physical, chemical & bacteriological parameters and submitting the report in duplicate with comparison by IS-10500, complete for 29 parameter.
Supplying only Resistance lowering GEL Make : DSS. (Earth enhancing compound for earthing).
Material and labour for valve chamber of size 1200x1200x900 mm ( Intenal dimensions) with brick masonry valve chamber, PCC foundations, plastering and necessry excavation and earth work in hard/dense soil, MS sheet cover 3.15 mm thickness alongwith angle iron frame of size 40x40x6 mm with locking arrangment with ncessary fixing materials like hinges, nuts, bolts etc., ( Valve chamber cover shall be opened in two havels) and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete, all,as specified and directed.
All as per item No 204 above but size of valve chamber is 900 x 900 x 900 mm (internal) complete, all as specified and directed.
M&L for two coat of white wash over a coat of primer including prepaation of new surfaces complete, all as specified and directed.
Friends fire Engineers
Dheer Engineering
Amit Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .