Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹1.3 Craccepted-aoc | accepted-aoc |
Tender Value
₹1.7 Cr
EMD Value
₹1.7 L
Closing Date
7 Aug 2026, 3:00 pmClosed
CHIEF ENGINEER, TTD, TIRUPATI
TTD, Tirupati
Construction of additional class rooms in 3rd floor on Eastern side of SPW Junior College, TTD, Tirupati
965779
63/SE-I/TTD/2026-27
OPEN - NCB
Similar Work
TIRUPATHI
15 documents required · 15 mandatory
₹6,038
₹1.7 L
6 Oct 2026
22 Jul 2026
22 Jul 2026
Demolition including stacking of serviceable materials and disposal of unserviceable materials within 100 metres lead - Brick work.
Demolishing and disposal of unserviceable materials within 100 metres lead - Unreinforced cement concrete up to 15 cm thickness
Hire charges for engaging tractor for shifting of department materials to the specified places as directed during execution.
Earthwork excavation for foundations in ordinary Soil -Mechanical Means up to 3 m depth and depositing on bank for all lifts and with an initial lead of 10m including all Operational, incidental ,labour charges such as shoring, sheeting, planking, strutting etc., complete for finished item of work. Note: Cost of dewatering up to 5% may be added, where required, up to 10% of labour cost. Assessment for dewatering shall be made as per site conditions.
Earthwork excavation for foundations in ordinary Soil -Manual means up to 3 m depth and depositing on bank for all lifts and with an initial lead of 10m including all Operational, incidental ,labour charges such as shoring, sheeting, planking, strutting etc., complete for finished item of work. Note: Cost of dewatering may be added, where required, up to 5% of labour cost. Assessment for dewatering shall be made as per site condition
Filling with useful available excavated earth (excluding rock) in trenches, sides of foundations and basement with initial lead in layers not exceeding 15 cm thick, consolidating each deposited layer by watering and ramming including cost and conveyance of water to work site and all operational, incidental, labour charges, hire charges of T&P etc., complete for finished item of work. Note: Cost of transportation of good quality earth has not been included. Only labour for carrying carted earth with a lead of 50 m to the foundation pits has been taken in the rate. The cost of carted earth / sand may be worked out separately if the same is not available from the adjoining area.
Filling of foundations and basement with best river sand in layers of not more than 15 cm thick each well watered to saturation and consolidated including cost and conveyance of all materials, incidental charges etc., complete.
Cement Concrete (1:4:8) using 40 mm ( 0.54 Cum), 20mm (0.27 Cum) and 12 mm (0.09 Cum) nominal size hard broken granite crushed metal from any source conforming to the relevant ISI standards for foundations etc., laid in layers of not more than 15 cm thick well compacted including curing, machine mixing, cost and conveyance of all materials etc., complete.
-do- in First floor
-do- in Third floor
Supply and placing of M 25 Design Mix Concrete corresponding to IS 456 using concrete mixer using of 20 mm HBG crushed metal 0.530 Cum (707 kg),10 mm HBG crushed metal, 0.362 Cum (471 kg) , sand 0.407 Cum (616 kg.) and cement 380 kg with water cement ratio of 0.48 ( 182.40 ltrs/ Cum of CC) etc., to site and including sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, vibrating, laying concrete, curing , cost of centering, shuttering charges using steel scaffolding pipes, jack props, wallers, Foot plates, brackets, steel centering plates, etc.complete with cement from standard suppliers approved by the department and excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402).
Note : The design mix shall be got designed by furnishing the information required as per clause 19.1.1 &19.1.2 of IS 456-2000 by the contractor at his own cost and get approved from the competent authority before execution. The cement considered for above M25 grade concrete is 380 kg/cu.m and the rate is arrived accordingly in the estimate. After the mix is designed and approved, if there is any variation in the quantity of cement, over the cement content adopted in the estimate, the same will be considered and paid/recovered at estimate rate +/- T.P ( Either increase or decrease in quantity adopted in the estimate). Payment will not be made for variation in the quantity of other materials such as coarse & Fine aggregates.
For columns up to basement (Pedestals)
For Plinth Beams
-do- in first floor
- do- in second floor
-do- in third floor
-do- in fourth floor
-do- in first floor
-do- in Second floor
-do- in Third floor
-do- in Second floor
-do- in Third floor
-do- in Fourth floor
Roof slabs (Excluding centering chargers)
-do- in Second floor
-do- in Third floor
-do- in Fourth floor
RCC walls (Excluding centering charges) -do- in first floor
RCC M- 20 Design mix using 20mm HBG crushed metal 0.480 cu.m , 10mm HBG crushed metal 0.320 Cum , sand 0.400 Cum and cement 350 kg with water cement ratio of 0.53 (185.5 Lit per Cum of CC ) etc. horizontal plain sunshades or lofts 0.60 m width projecting from the face of the wall 65mm average thickness,80mm thick at the face of the wall and 50mm thick at the free end and cast monolithically with the lintels or tailed to the full thickness of the wall where there are no lintels using 20mm size graded machine crushed hard granite metal (coarse aggregate) from any source conforming to the relevant ISI standards including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including all operational, incidental and labour charges such as machine mixing, laying concrete, curing , etc.,complete, but including cost of steel centering charges and excluding cost of steel and its fabrication charges for finished item of work. .- do - 0.60 m width (1.0 x 0.065 x 0.60)
.-do- in first floor
-do- in Second floor
-do- in Third floor
Supply and placing of the M20 Design Mix using of 10 mm HBG crushed metal 0.480 cu.m, 6 mm HBG Crushed metal 0.320 cu.m, sand 0.400 cu.m and cement 350 kg with water cement ratio of 0.53 (185.50 ltrs/cu.m of CC) etc., from any source conforming to the relevant ISI standard including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including all operational, incidental and labour charges such as machine mixing, vibrating, laying concrete, curing etc., complete with minimum cement content as per IS code from standard suppliers approved by the department but excluding cost of steel and its fabrication charges,centering charges, shuttering charges for finished item of work (APSS No. 402) .- do - for 50 mm thick precast slabs using 10 mm graded aggregate HBG crushed metal from any source conforming to the relevant ISI standards with necessary reinforcement, but including cost of necessary form work etc., complete as directed by the department.
Hire charges for centering and scaffolding of roof slabs up to 150 mm thick, with unsupported height up to 3.66 m - Casurina ballies, Bamboos, wooden reapers, runners, wood posts,wall plates,steel centering plates etc., complete as directed during execution.
-do- in Second floor
-do- in third floor
-do- in fourth floor
Centering charges for RCC Vertical walls of plane surface (rate is for both sides centering) including open drains. Note: The Centering charges are for both the faces of the respective numbers. The measurement of centering charges shall be in "Sqm" for one face only and the centering charges given are for two faces of centering.
"Providing High Yield Strength deformed (HYSD)/ Thermo mechancially treated (TMT) steel bars of specified grade (as per IS 1786 - 2008) of High Yield Strength Deformed bars below 36 mm Fe - 500/Fe - 500D /Fe 550 grade for RCC works, including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars including all wastages such as over laps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors. (APSS NO.126) (In the absence of 18G binding wire,2 nos of 20G binding wire in tandem are to be strictly adhered). Note: Unless otherwise fabrication and placement of steel, no pre-pament shall be made against the supply of steel reinforcement"
Construction of Brick Masonry in CM (1:6) using well burnt Bricks 2nd class or ground moulded (Non modular or traditional size) (230 x 110 x 70 mm) including curing, cost and conveyance of all materials as directed during execution and complying with standard specifications etc., complete.
-do- Up to basement Level
-do- in First floor
-do- in Second floor
-do- in Third floor
-do- in Fourth floor
Construction of 110 mm thick Brick partition walls in C.M.(1:5) using well burnt bricks 2nd class or ground moulded (Non modular or traditional size) bricks (230X110X70 mm) including curing, cost and conveyance of all materials etc,. complete
-do-- in First floor
-do- in Second floor
--do-- in Third floor
Plastering in Cement Mortar (1:3) 12 mm thick using best river sand from approved quarry including cost and conveyance of all materials, screening, curing, rounding of corners, incidental charges as directed during execution complying with standard specifications etc., complete.
--do-- in first floor
--do-- in second floor
--do-- in third floor
--do-- in Fourth floor
Plastering in Cement Mortar (1:5) 12 mm thick using best river sand from approved quarry including cost and conveyance of all materials, screening, curing, rounding of corners, incidental charges as directed during execution complying with standard specifications etc., complete.
-do- Up to basement Level
--do-- in first floor
--do-- in second floor
--do-- in third floor
--do-- in fourth floor
Plastering in Cement Mortar (1:5) 20 mm thick using best river sand from approved quarry including cost and conveyance of all materials, screening, curing, rounding of corners, incidental charges as directed during execution complying with standard specifications etc., complete.
-do- Up to basement Level
--do-- in first floor
--do-- in second floor
--do-- in third floor
--do-- in fourth floor
Supplying and fixing in position M.S Ornamental grills for windows and ventilators or for veranda openings using M.S. Flats, square rods, angles sheets etc., of approved design including necessary cuttings, bending fabrication, welding, grinding and finishing smooth including painting the grills with Two coats with Synthetic enamel paint over a Primary coat (Red oxide metal primer) (total three coats) of approved make and colour including cost of making the holes into RCC or masonry works and making good the same wherever necessary, including cost and conveyance of all materials, incidental charges etc., complete.
Supply and fixing of stainless steel SS304 grade tubes, sections, plates , sheets and pipes of all sizes and diameters etc., including cost and conveyance of all materials and labour charges for fabrication of stainless steel railing works using SS welding rods including buffing , polishing, lacquer finishing , to present seamless finishing etc., complete as directed during execution.
Supplying and fixing in position Flush door shutters of different sizes with 35 mm thick, solid bond wood block board type with teak veneer on one face and commercial ply on another face (lipping): conforming to IS:2202 of standard make, solid core flush doors with hot pressed bonded with liquid phenol formaldehyde with rebate cutting, Double leaf using Best Indian Teak wood frames of size 65 mm x 100 mm without threshold plate, including cost of M.S "Z" Hold fasts of 230 x 50 x 6 mm, M.S. Powder coated Butt hinges of 125 x 65 x 2.12 mm, screws, nails, etc., complete, (excluding cost of other fixtures which will be paid separately but including labour charges for fixing the fixtures).
Supply and fixing of following Anodized Aluminum fixtures for doors and windows
--do-- tower bolt - 10 mm x 300 mm Long with ISI Mark IS 204
--do-- Anodised Aluminium Aldrop (IS 2681) 300 mm long.
--do-- Door Handles (IS:208) 150 mm Long
--do-- Heavy duty Aluminium Door stopper
Providing and fixing factory made uPVC any colour sliding glazed window up to 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, TPV, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc.. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing& direction of Engineer-in-Charge inclusive of cost of Single / double glass panes, wire mesh and silicon sealant .
Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted. But no extra payment on this account shall be made. -do- three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mmboth having wall thickness of 1.9 ± 0.2 mm and single glazingbead of appropriate dimension (Area of window upto 1.75 sqm).
Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket,/TPV GI fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hard ware's and drainage of water etc.
After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge inclusive of cost of Single/ double glass panes and silicon sealant. Fixed windows/ ventilators made of (small series) frame 47 x 50mm & mullion 47 x 68 mm both having wall thickness of 1.9 ±0.2 mm and single glazing bead of appropriate dimension. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Providing and applying wall putty of white cement or polymer or cement based or equivalent putty of approved make average 1 to 2 mm thickness over plastered surface to prepare the surface even and smooth after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, applying emery paper, sand the surface, clean & wipe off loose dust, applying knifing paste filler by putty knife / muslin pad, air dry for 2-3 hrs. sand with 180 and 320 No., emery paper for the surface preparation including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc., complete for finished item of work .excluding scaffolding charges - For New work.
Painting two coats for new internal walls with Acrylic Emulsion paint interior grade having VOC (Volatile Organic Compound) content less than 50 grams/liter of approved brand and shade over a priming coat with ready mixed cement primer (water thinnable) of interior grade-I ( total three coats ) after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc., complete for finished item of work as per SS 911 for new internal walls.
Painting two coats for new external walls with Acrylic Emulsion paint exterior grade with silicon additives having VOC (Volatile Organic Compound) content less than 50 grams/liter over a priming coat with ready mixed cement primer (water thinnable) of exterior garde- II ( total three coats ) of approved brand and shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc., complete for finished item of work as per SS 911 for New External walls.
Painting two (2) coats for new wood work, with ready mixed synthetic enamel paint in all shades grade-I having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved colour and make, over priming coat with ready mixed wood primer for new wood work (total three (3) coats) including brushes to have an even shade, including cost and conveyance of all materials, as directed during execution, complying with standard specifications etc., complete.
Flooring with Telephone Black Granite 18-20 mm thick upto 2.43 M set over base coat of cement mortar (1:8) 20 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 kgs per sqm & jointed neatly with white cement paste mixed with pigment of matching shade to full depth, including cost & conveyance of all materials, seigniorage charges, labour charges for dressing of tiles etc., complete for finished item of work. (Note: Unless otherwise laying of flooring is finished, no pre-payment shall be made for the slabs against supply)
--do-- in first floor
--do-- in Second floor
--do-- in Third floor
Providing skirting to internal walls/ risers of steps with Cheery Red granite 18-20 mm thick upto 2.43M length equal to flooring stones, set over base coat of CM (1:3) 12 mm thick with cement slurry of honey like consistency spread at the rate of 3.30 Kgs per sqm and jointed with white cement paste mixed with pigment of matching shade to full depth, including cost and conveyance of all materials curing incidental charges etc., complete for finished item of work. (Note: Unless otherwise finishing of sides is completed, no pre-payment shall be made for the slabs against supply)
--do-- in first floor
--do-- in Second floor
--do-- in Third floor
Providing skirting to internal walls/ risers of steps with telephone Black Granite 18-20 mm thick upto 2.43M length equal to flooring stones, set over base coat of CM (1:3) 12 mm thick with cement slurry of honey like consistency spread at the rate of 3.30 Kgs per sqm and jointed with white cement paste mixed with pigment of matching shade to full depth, including cost and conveyance of all materials curing incidental charges etc., complete for finished item of work. (Note: Unless otherwise finishing of sides is completed, no pre-payment shall be made for the slabs against supply)
--do-- in first floor
--do-- in Second floor
--do-- in Third floor
Full Rounding the edges of Marble/ Granite stone slabs of all thicknesses including polishing the same.
Half Rounding the edges of Marble/ Granite stone slabs of all thicknesses including polishing the same.
Flooring with vitrified tiles of 1st quality of following varieties of series and shades set over base coat of cement mortar (1:6) 20 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 kg per sq.m & joints with spacer joints with 3 mm wide jointed neatly with filer material of cement/epoxy grout/white cement paste to full depth mixed with pigment of matching shade as directed during execution, including cost and conveyance of all materials, etc., complete - for finished item of work. (Note: Unless otherwise laying of flooring is finished, no pre-payment shall be made for the tiles against supply) - do- Supply of Double charged (with double layer pigment) / multi charged stain free full body porcelain vitrified tiles of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs
--do-- in Third floor
Providing skirting to internal walls to the following heights / risers of steps with vitrified tiles length equal to flooring stones, set over base coat of CM (1:3) 12mm thick with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sq.m and jointed with white cement paste mixed with pigment of matching shade to full depth, including cost and conveyance of all materials, etc., complete - for finished item of work. - do - Supply of Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs
--do-- in Third floor
Providing skirting to internal walls up to 15 cm height / risers of steps with ceramic tiles length equal to flooring stones, set over base coat of CM (1:3) 12mm thick with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sq.m and jointed with white cement paste mixed with pigment of matching shade to full depth, including cost & conveyance of all materials, etc., complete - for finished item of work. - do - Polished Ceramic tiles 1st quality of size not less than 600x600x8 mm thick of all shades & designs (Group B II of IS 15622 -2006, water absorption should be between 3 to 6%)
--do-- in Third floor
Flooring with Antiskid floor tiles 1st quality of all series & shades (as per manufacture specification), set over base coat of cement mortar (1:6) 20 mm thick over CC bed already laid or RCC roof slab, including white cement slurry of honey like consistency spread @ 3.30 kgs per sq.m. jointed with neat cement to full depth mixed with pigment of matching shade, including cost and conveyance of all materials like flooring slab, cement, sand and water etc., complete, for finished item of work. (Note: Unless otherwise laying of flooring is finished, no pre-payment shall be made for the tiles against supply) -do- Supply of Non-skid red or white full body Ceramic floor tiles of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs
--do-- in Third floor
SPECIALISED FIVE LAYER SYSTEM OF WATERPROOFING TREATMENT TO THE TERRACE WITH THE FOLLOWING SPECIFICATION.
Providing and laying five layer water proofing cu.m heat insulation treatment (MIX GUARD HR5) over existing roof slab, all as directed by Engineer-in-charge and as per the following specification: Arresting roof leakage by providing five layer treatment with MIX GUARD HR5 – five layer system of FAB Chemicals or equivalent elastomeric water proofing and heat reflective coating comprising of the following:
A. Surface preparation – Cleaning the whole area with wire brush. Chipping all loose/dead mortar thoroughly. Cleaning the entire area with high pressure water jetting to remove all loose particles/grease/oil/dust/dirt/curing compound etc. Surface cracks must be filled with Mix Build GP and wide cracks must be cut and repaired with Mix build SR polymer modified repair mortar. B) Application of Mix Guard HR5 – five layer system with brush.
1. First layer – MIX PRIME AC-100 Apply base prime coat using Mix Prime AC100 compound which is produced by mixing Mix Prime AC-100 with water and cement at the ratio 2:1:3 (Mix prime AC 100 : water : cement) by volume with a slow speed drill with paddle. This compound shall be applied with sufficient thickness to cover the holes/pores/cracks @ 1 lit/Sqm area (0.35 Lt of MIX Prime AC100/Sqm)
2. Second Layer – MIX MAT GFM 70/50 Mix mat GFM70/50 Synthetic fibre reinforced mesh shall be spread on the top of the primer/in mix with Mix prime AC100 in the wet condition and allow to dry for a period of 6 to 8 hours. A minimum overlap of 100 mm to be provided at the joints i.e. at 1.10 Sqm/Sqm. The Mix mat GFM Mesh shall confirm to the technical specification as per the manufacturers data sheet(40 Gram / Sqm as a weight)
3. Third Layer – MIX PRIME AC Apply one coat of Mix Prime AC water based acrylic primer (with undiluted material) over the MIX mat GFM mesh @ 0.25 Kg/Sqm as a water tight primer in white colour and allow to dry for a period of 6 hours.
4. Fourth layer – MIX GUARD HR (Base Coat) Apply one coat of Mix Guard HR acrylic based water proof and weather proof coating in white colour (with undiluted material) @ 0.50 kg/Sqm as a membrane on top of Mix prime AC and allow to dry for a period of 6 hours.
5. Fifth Layer – Mix Guard HR Extra (Top Coat) Apply one coat of Mix Guard Hr Extra acrylic based fibre reinforced water proofing and heat reflective membrane in white colour on top of Mix Guard HR base coat (With undiluted material) @ 0.50 kg/sq.m. And allow to dry the system for period of 24 hours to allow foot traffic.
Note: All the materials namely Mix Prime AC100, Mix Mat GFM70/50, Mix Prime AC, Mix Guard HR and Mix Guard HR Extra shall be procured for the entire work order quantity based on the consumption/coverage area as specified in the specification and shall be ensured by Engineer-in-charge. The Mix Guard HR5 layer system shall be carried out as per FAB Specifications.
Tensile strength : 6.00 N/mm2 (ASTM D412 – 87), Adhesion to substance : > 1.5 N/mm2 (ASTM D4541) for MIX PRIME AC100 slurry with HP tiles, cementitious substrate and subsequent layers. Appearance: White/Grey/Terracotta liquid components. Dry film apperance : Joint free membrane Density : 1.3 gm/cc
Tear strength : > 17 N/mm2 (ASTM D1004-76) . Elongation at break : 200% for the system (ASTM D638). DFT of cured membrane : 1500 to 1700 microns Total Solids content: 68% + 2% . Water penetration : No leak at 7 bars +ve side (DIN 1048). Application temperature : 5 deg C to 50 deg C. Touch dry: 2 hrs at 25 deg C. Recoatable : 6-8 hrs at 25 deg C. Full cure: 7 days.
SPECIALISED FIVE LAYER SYSTEM OF WATERPROOFING TREATMENT TO THE TERRACE WITH Roofcare-prc 5 Systems or equivalent ( ROOFCARE PRC 5 (Armstrong) / ZORICOAT PFC 5 (PMCC)/ POWER SAC 5 L (EBT)/ WATERSHIELD 5 LWC.
a). Ist Layer : Black coloured chemcial treatment : Providng and application of one coat of High bonding, flexible bituminous polyurethane blended bituminous coating with – Roofcare prc 5 systems Confirming to ASTM-G 154 -2000 or equivalent Ist Layer diluting with water at 1 : 1 ratio as a primer coat at a consumption of 200 ml per Sqm.
b). IInd Layer : Providing and laying of Fibre Mesh 40 GSM, with 1 Mtr width and 50 mm overlap on the primed surface.
c). IIIrd Layer : Grey coloured coating : Providing and application of one coat of Acrylic rubberized elastomeric flexible waterproof grey coating with – Roofcare prc 5 systems ASTM-C 836 or equivalent or equavalent diluting with 50% of water at a consumption of 400 ml per Sqm.
d). IVth Layer : white colured coating : Providing and application of one coat of High solid, cold applied, Fibre reinforced acrylic elastomeric waterproof membrane off white coating –Roofcare prc 5 systems Confirming to ASTM-G 154 -2000 or equivalent coating (add the water upto 200 ml ) (Consumption of 350 ml per Sqm ).
e). Vth Layer : super white reflective coating : Application of one coat of 100% pure acrylic solar reflective pure white coating with Roofcareprc 5 systems Confirming to ASTM -C 297 or equivalent solar reflective coating diluting with 20% of water (Consumption of 300 ml per Sqm ).
Note : THE ABOVE TREATMENT WILL BE GUARANTEED FOR 5 YEARS
Supply of Rabbit wire mesh (Chicken mesh) of not less than 30 gauge.
Providing weather proof course with Screeding concrete in CC(1:2:4), 25mm average thickness using 6 to 10mm nominal size HBG crushed metal chips, screeding duly embedding 24G chicken mesh with necessary overlap etc.., and finishing the surface neatly and rounding the edges at parapet walls, columns etc., including cost of chicken mesh, including cost of all materials and conveyance of all materials etc., complete as directed during execution.
-do- in Fourth floor
Providing impervious coat to exposed RCC roof slab surface with CM (1:3), 20mm thick with 500 ml of liquid concentrated micronized cement water proof compound/ 100 ml of Integral cement water proofing admixture complies with IS:2645-2003 of approved make per 50 kg bag of cement laid over roof when it is green including cost of all materials, conveyance charges of materials and all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc., complete for finished item.
-do- in Fourth floor
Conveyance of waste materials such as dismantled materials and surplus excavated earth etc., with a lead of 3 km from work site and as directed during execution etc., complete
Providing Unplasticized PVC SWR Rain water downfall pipes for the following dia with ISI:13592 Type -A mark with necessary shoes, bends, collars etc., including making holes in walls, RCC slabs, beams, columns, including fixing with necessary wooden plugs (where it is required pipe clear of wall, wooden blocks of size equal to that of ears of the pipe shall be used), screws, iron clamps of 18 G and making good the same including cost and conveyance of all materials and incidental charges etc., complete as directed during execution.- 110 mm dia PVC pipe with wooden block of size 150mmx50mmx50mm
Labour required for attending various miscellaneous works like hack for the existing flooring, removing the existing pipes, closing of gaps, putty patch works, fixing of SS fly proof mesh for windows and removing existing doors & resize and refixing of door with fittings etc.,
- do - Semi skilled work men (2nd Class) Mason/ Carpenter/ Plumber/ Painter
- do - Supply of Unskilled work men - Man/ Woman Mazdoor/ Watchman
Providing, laying, spreading and compacting graded stone aggregate (IRC size HBG crushed stone aggregate confirming to Table 400-12 & Table 400-13) to Wet mix Macadam specification including premixing the material with water at OMC in Mechanical mixer, carriage of mixed material by Tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with Vibratory roller 8-10 Tonnes weight to achieve desired density including lighting, barricading and maintenance of diversion etc., as per Technical specification vide clause No.406 of MORTH (5th Revision) etc., complete in all respects and as directed by Engineer-in-charge during execution. -do- for thickness of more than 100 mm using vibratory roller .- do - for thickness of more than 100 mm
NOTE: 1. As three wheeled smooth steel rollers are commonly in use, the same has been provided as an alternative which can be used if the thickness of individual layer does not exceed 100 mm. 2. The thickness of single compacted Wet Mix Mecadam layer shall not be less than 75 mm. 3. The thickness of single compacted Wet Mix Mecadam layer shall not be more than 200 mm.
Providing and fixing pre-cast concrete blocks (interlocking pavers) using not lessthan M40 grade paver blocks and thickness not less than 80 mm for medium traffic areas conforming to IS 15658-2006 of all shapes and designs as per the specification, over sand bed of 20 mm to 40 mm (30 mm average) thickness and compacting with vibrating plate compactor having 3 tonne compaction force there by forcing part of sand underneath to come up in between joints. final compaction of paver surface to be done after spreading and brushing the fine sand into joints to its final level. The work includes cost of all materials such as interlocking pavers, sand etc., Labour and equipments such as cutting machine, lift, loading & unloading to work site clearing, bringing required all materials for the successful completion of work as per drawings and Technical Specification Clause 1504 MORD and as directed during execution by the Engineer-in- charge of the work.
Note: i. Thickness of interlocking pavers and underlaying sand bed shall be as per the Table 1 of IRC SP:63-2004 based on the traffic and type of road. The data can be worked out accordingly. i.e. 1.Cycle tracks and pedestrain footpaths, 2. Residential streets, 3. Industrial streets, bus and truck parkings areas and 4. Arterial streets, etc. ii. The base and sub-base over which interlocking pavers are to be laid shall also be as per the Table 1 of IRC SP:63-2004 based on the traffic and type of road/ground surfaces.
Supply of glow sign vinyl stickered name plate / sign (or) instruction boards using 3mm foam white sheet as back ground and glow sign vinyl sticker one layer for letters of different sizes as directed during execution including cost of 3mm foam sheet vinyl sticker and all labour charges for computer design and cutting, pasting and fixing the boards as directed during execution.
Supply of glow sign vinyl stickered name plate / sign (or) instruction boards using 4mm ACP (Aluminum composite panel )sheet as back ground and glow sign vinyl sticker one layer for letters of different sizes as directed during execution including cost of ACP sheet, vinyl sticker and all labour charges for computer design and cutting, pasting and fixing the boards as directed during execution.
SPECIALISED POLYSULPHIDE SEALANT TREATMENT TO THE EXPANSION JOINTS ON TERRACE : (Size : 25mm x 12mm) Application of one coat of-High performance specially designed SBR latex polymer based bonding agent–ROOFBOND SBR (Armstrong) / POWER n BOND SBR (EBT) / NITOBOND SBR (Fosroc)ZORIBOND SBR (PMCC)/ SIKA LATEX (Sika) WATERSHIELD BOND SBRASTM - C 920 -95 /DIN 18549 TT -S-00227E or equivalent mixing with cement as per manufacturers c]. Providing and application of Acrylic Polymer modified reinstatement concrete/mortar admixture with - ROOFCRETE AR (Armstrong ) / ZORIGROUT CMG (PMCC) / POWER n GUARD ARM (EBT) / WATERSHIELD AR / Fosroc to finish the damaged edges of joint and making the groove. d]. Providing and fixing of masking tape on top of the joint both sides. e]. Providing and fixing of Back up support material of Polyethelene foam to leave the depth of 12mm on the joint. f]. Providing and application of one coat of polysulphide primer with –
Polysulphide primer on inner edge on joints. g]. Providing and application of Two part Polysulphide sealant to a width of 25mm and 12mm depth with - ROOFSEAL PS (Armstrong ) / POWER n SEAL PS (EBT) /NITOSEAL PS 200 (Fosroc)/ ZORISEAL PS (PMCC) / SIKA POLYSULPHIDE (Sika) / WATERSHIELD PSComplies with BS 4254 - 83 or equavalent with putty knife and neat finish. h]. Removing of masking tape and providing and application of two coats of Acrylic elastomeric cementitious coating with - ROOFSEAL PS (Armstrong ) / POWER n SEAL PS (EBT) /NITOSEAL PS 200 (Fosroc)/ ZORISEAL PS (PMCC) / SIKA POLYSULPHIDE (Sika) / WATERSHIELD PS FOR ARRESTING WATER FLOW LEAKAGES, LEAKAGES OF CONSTRUCTION JOINTS OF RESERVOIRS / PUMP ROOMS / POWER HOUSE / PENSTOCK / CANAL DUCTS AND OTHER WATER RETAINING STRUCTURES EXECUTION IN THE PRESENCE OF WATER.
Supply of Aluminium sheet 24 Gauge
ELECTRICAL ITEMS
Supply and Fixing of ISI mark 25mm outer dia heavy grade (2.20mm thickness) with IS:9537 part -3 P.V.C. pipe for concealed wiring in new / existing brick building, walls, columns, beams duly cutting them to the required depth wherever necessary and fixing the pipes and specials with nails and plastering neatly with cement mortar and colour washing to match the finished surface and masonry work for light, fan and separate plug point including all labour charges etc., complete. Makes: Sudhakar / Finolex / Polycab / Kumar / AKG / Indian-tubes / GM / Anchor / Nandi / Polyline / Gold Medal
Supply and wiring with 2 run of 14/0.3mm (1.0 sq.mm) PVC insulated FRLS flexible copper cable (ISI MARK) as per IS:694 / 1990 specification in existing PVC pipes / casing & caping with 2 plate Jumbo ceiling rose, 6 Amp 1 Way Module Modular switch to switch control box including all labour charges etc., complete for Light, bell, fan and Exhaust fan points in Non-Residential Buildings. Grade-B : Wire Makes: Atlas / Gold medal / Delton / Standard / GM / RPG / V-Guard / HPL / Anchor / Orbit Grade-B: Modular Switch Makes: Legrand Myrius /Crabtree Thames Platinum / Anchor Roma / Clipsal / Havells Coral or Fabio / Goldmedal (Curve/Air) / Schneider Livia / C&S / L&T / HPL / GM (GNINE) / Kolars / Indo asian
Supply and run of 3 wire of 36/0.3mm (2.5 Sq mm) PVC insulated flexible FRLS copper cable as per IS:694 / 1990 specification in the existing PVC pipe / MS pipe /PVC Trunking for mains including all labour charges etc., complete. Grade-A: Makes: Finolex / RRKabel / Havells / Polycab / L&T / KEI
Supply and run of 3 wire of 56/0.3mm (4.0 Sq mm) PVC insulated flexible FRLS copper cable as per IS:694 / 1990 specification in the existing PVC pipe / MS pipe /PVC Trunking for mains including all labour charges etc., complete. Grade-A: Makes: Finolex / RRKabel / Havells / Polycab / L&T / KEI
Supply and fixing of 6 /10 Amps 1 way 1 module Modular Switch on to the existing metal box (Switch Control Box) cover frame and giving necessary connections including all labour charges etc., complete. Grade-B: Makes: Legrand Myrius / Crabtree Thames Platinum / Anchor Roma / Clipsal / Havells Coral or Fabio / Goldmedal (Curve/Air) / Schneider Livia / C&S / L&T / HPL / Kolors / Indo Asian / GM (GNINE)
Supply and fixing of 6 /10 Amps 3 / 2 pin 2 module Modular Socket with shutter on to the existing metal box (Switch Control Box) cover frame and giving necessary connections including all labour charges etc., complete. Grade-B: Makes: Legrand Myrius / Crabtree Thames Platinum / Anchor Roma / Clipsal / Havells Coral or Fabio / Goldmedal (Curve/Air) / Schneider Livia / C&S / L&T / HPL / Kolors / Indo Asian / GM (GNINE)
Supply and fixing of 16 /20 Amps 1 Way 1 Module Modular Switch on to the existing metal box (Switch Control Box) cover frame and giving necessary connections including all labour charges etc., complete. Grade-B: Makes: Legrand Myrius / Crabtree Thames Platinum / Anchor Roma / Clipsal / Havells Coral or Fabio / Goldmedal (Curve/Air) / Schneider Livia / C&S / L&T / HPL / Kolors / Indo Asian / GM (GNINE)
Supply and fixing of 100 W Fan Step Type Regulator Tiny of Modular on to the existing metal box (Switch Control Box) cover frame and giving necessary connections including all labour charges etc., complete. Grade-B: Makes: Legrand Myrius / Crabtree Thames Platinum / Anchor Roma / Clipsal / Havells Coral or Fabio / Goldmedal (Curve/Air) / Schneider Livia / C&S / L&T / HPL / Kolors / Indo Asian / GM (GNINE)
Supply and fixing of 3 Modular Cover Plate & Frame on to the Existing Metal Box (Switch control Box) including all labour charges etc., complete. Grade-B: Makes: Legrand Myrius / Crabtree Thames Platinum / Anchor Roma / Clipsal / Havells Coral or Fabio / Goldmedal (Curve/Air) / Schneider Livia / C&S / L&T / HPL / Kolors / Indo Asian / GM (GNINE)
Supply and fixing of 12 Modular Vertical Cover Plate & Frame on to the Existing Metal Box (Switch control Box) including all labour charges etc., complete. Grade-B: Makes: Legrand Myrius / Crabtree Thames Platinum / Anchor Roma / Clipsal / Havells Coral or Fabio / Goldmedal (Curve/Air) / Schneider Livia / C&S / L&T / HPL / Kolors / Indo Asian / GM (GNINE)
Fixing of given Tube light luminaire / PL fitting on wall / Ceiling / Trusses / Channels on PVC/ TW round blocks / Epoxy insulator / 3"x2"x1" TW reaper with all accessories, labour charges and giving necessary connections.
Fixing of M.V / S.V / M.H luminaire / Halogen fitting on wall / pole cross arm / channel / stem pipe etc., including all labour charges and giving connections etc., complete.
Supply and fixing of fan hook made out of 3/8" (10mm) M.S.Plain rod and providing to the existing M.S. Rod at the time of concreting the roof slab.
Fixing of Ceiling fan including transportation and giving connections with twin core wire etc., complete.
Supply and Fixing 19/20mm dia MS tubular fan down rod of one meter length with bolts & nuts duly painted with matching colour of fan complete
Supply and fixing of 4 Way TP & N Horizontal type Distribution board as per IS 8623; IS 13032; IEC 61439-3 with IP-43 protection (Metal door) firmly concealed in the wall with neat plastering etc., complete. Grade-B: Make: ABB / Standard / Havells-euro II / C&S / L&T / GM / Gold Medal / Indo Asian
Supply and fixing of 6 to 32 Amps range S.P MCBs 10 KA breaking capacity 'C'/ 'D' Curve ISI Mark as per IS:60898-1:2002 in the existing board and giving necessary connections. Grade-A: Makes: Legrand DX3 / Schneider-Acti9 / Hager - Novello+ / Seimens / Havells STADx / L&T- Newrang / Indoasian (Opti pro).
Supply and fixing of 40 to 63 Amp FP MCBs 10 KA breaking capacity 'C' / 'D' Curve ISI Mark as per IS:60898-1:2002 in the existing board and giving necessary connections. Grade-B: Makes: ABB / Standard / Havells-euro II / C&S / L&T / GM / Goldmedal / Hager / Indoasian.
Fabrication, Transportation and supply of hot-dip galvanized Octogonal Pole with BSEN - 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangement, including the supply of suitable boards with bakelite sheet as per IS specification suitable to withstand the wind speed of 180 KMPH for 7.50 Mtrs height Pole having dimensions Bottom 130 mm,. Top 70mm with 3mm thick, base plate 220 x 220 x 12mm and 4 Nos of M20 x 700 long 'J' bolts along with template. Makes: Bajaj / Valmont / Laasma / Transrail / Utkarsh / Skipper
Fabrication, Transportation and supply of 1.0 Mtr Length Double Arm Bracket made with MS galvanized 40mm / 50mm dia Pipe. Makes: Bajaj / Valmont / Laasma / Transrail / Utkarsh / Skipper
Foundation and erection charges with special T&P, for 7.50 Mtrs long Octagonal /Conical pole duly erecting on base plate duly providing 4 Nos foundation bolts with nuts with providing of 0.45Mtr x 0.45Mtrs x1.20 Mtr size M20 cc work vibrated concreting mixing with necessary steel (10kgs) reinforcement and curing for 7 days as directed by the field engineers during execution including excavation of Earth/BT all labour charges and cost and conveyance of materials etc., complete.
Supply and fixing of suitable out door type feeder piller box made with 14 SWG CRCA sheet after 7 tank process including S & F of Legrand / Schnieder / L&T make 40-63A FP MCB, 9 Nos SP MCB's,din chanel, bus bars, 6 Sqmm 3 core copper cable for internal wiring , contactor, connectors and provision for energy meter etc., complete for finished item of work
Supply and transportation of 16 Sq.mm 4 core LT XLPE insulated, 1100V grade armoured Aluminium UG cable as per specification confirming to IS:7098 (Part-I) / 1554-1. Grade-A: Make: Torent / Universal / Unistar / Havells / KEI / Gloster / Polycab / RR Kabel / Finolex.
Laying of U.G cables upto 50 Sq.mm and back filling of trench including labour charges etc., complete.
Supply of 2.5 Sq.mm x 3 Core Flat Copper cable of ISI for Submersible Motors confirming to IS:694:1990. Makes: Finolex / RR Kabel / Polycab / Havells / KEI / Gloster.
Supply and making end termination with heavy Alluminium lugs (pin / ring type) upto 16 Sq.mm cable as per IS specification duly crimped with crimping tool, PVC tape etc., complete. Make: Dowels / Jainson / Comet.
Supply and fixing of fabricated M.S clamps made out of 25mm x 3mm MS flat with necessary holes on either side with 1 1/2" coach screws and painting 2 coats of enamel black paint over one coat of red oxide suitable for fixing of UG Cables of size 10 Sq.mm to 16 Sq.mm on walls etc. including all labour charges etc., complete.
Supply and fixing of 3 Module Hot Dip Galvanized 20 / 18 SWG Module box with earthing terminal concealed in wall with all required accessories including masonry work and all labour charges etc., complete. Make: Legrand / G.M / L&T / GM Four-Five / Legrand Arteor / Schneider / Anchor / Clipsal / Havells / ABB / Indo Asian / Siemen / Fortune Art.
Supply and fixing of 12 Module Hot Dip Galvanized 20 / 18 SWG Module box with earthing terminal concealed in wall with all required accessories including masonry work and all labour charges etc., complete. Make: Legrand / G.M / L&T / GM Four-Five / Legrand Arteor / Schneider / Anchor / Clipsal / Havells / ABB / Indo Asian / Siemen / Fortune Art.
Providing of Independent Chemical Earthing after excavating an earth pit of size1.5 m X 0.9 m X 2.05 m(Top 1.50 m X 0.90 m X 0.9m & bottom 1.20 m X 0.90 m X 1.15 m) with the following specification: (a) The Earth Electrodes, 40mm dia, wall thickness 3.25 mm, terminal Size 25x8 mm, terminal hole dia 12 mm, 2 meter long, galvanized, including 1 bag (25Kg to a bag) of Earth Life Compound, as per IS 3043, Base Metal: IS marked branded mild steel pipes. Makes: Potential / Shake Hands / Mars / Tirumala / Arshlok earthing. b) The Earth Electrode shall be inserted into the ground for 1.75 Mtrs. Below the inspection chamber bottom 300mm all around this Earth Electrode shall be covered with 25 Kgs. Of Earth Life Compound
Providing of Independent Chemical Earthing after excavating an earth pit of size1.5 m X 0.9 m X 2.05 m(Top 1.50 m X 0.90 m X 0.9m & bottom 1.20 m X 0.90 m X 1.15 m) with the following specification: (a) Supply of Copper Earth Electrode, 38 mm dia wall thickness 1.60 mm, 2 meter long, inner space of pipe filled with high conductive material along with 1 bag (25Kg to a bag) of Earth Life Compound. Makes: Potential / Shake Hands / Mars / Tirumala / Arshlok earthing. b) The Earth Electrode shall be inserted into the ground for 1.75 Mtrs. Below the inspection chamber bottom 300mm all around this Earth Electrode shall be covered with 25 Kgs. Of Earth Life Compound
(c) The excavated gap shall be back filled with excavated earth, and shall be properly consolidated with water. (d) The top 0.25 m of Earth pipe shall be exposed into inspection chamber of Hume pipe . The all around inspection chamber shall be providied with 18" dia hume pipe. Earth connections shall be given to the Earth Elecrods with bolts, nuts & washers. (e) A 65 mm dia PVC conduit is to be embeded through hume pipe at one side, to lay the Earth from the Earth bus to the Electrode through the PVC conduit and after laying the Earth, the pit entry PVC conduit is to be sealed with Bitumen compound. (f) Necessary Meggar testing is to be done in the presence of the concerned Engineers, and the reading should be as per IE standards.
Supply and run of ' 8 ' SWG G.I wire for earth electrode to required places by concealing in walls, flooring by cutting the grooves and replastering neatly and giving necessary connection with 3/8"x2" GI Bolts, Nuts and Washers Wherever joints has to be done. The strip has to be either riveted (or) bolted (or) gas welding neatly and all labour charges etc., complete.
Supply and run of ' 8 ' SWG copper Wire for earth electrode to required places by concealing in walls, flooring by cutting the grooves and replastering neatly and giving necessary connection with 3/8"x2" Brass Bolts, Nuts and Washers wherever joints has to be done. The strip has to be either riveted (or) bolted (or) gas welding neatly and all labour charges etc., complete.
Earth Work excavation for trench for laying of U.G. Cable in ordinary Soils, manual means to the required width and depth and depositing the same on bank as directed during execution etc., complete .
Supply and transportation of 60 W LED Street light Luminaire made of pressure diecast aluminum body with powder coated, having protective toughened glass, supply input voltage 120 - 270V AC, P.F > 0.90, high power LEDs having System Efficacy >=120 lumens/watt and junction temperature < 70°C, with Ingress protection IP66, Luminaire performance complies to IS 10322 (Part 5/Sec-3), driver surge protection 4KV, in-house additional Surge protection 10 KV with optics distribution, THD<10% at 110 Volts AC, driver efficiency >90%, CCT: 3000K - 5700K, minimum CRI>70, etc., complete with earth connection and not less than two years warranty.
a) LUMINAIRE MAKE : Wipro(Skyline) / Philips (Green line) / GE-Venture / Crompton(Neo Series) / Bajaj (Edge) / Halonix(Lumos - Super) / Havells (Endura Series) /Capart(Premium)/Greenlites(Hi-Lux) /Polycab/Keselec/ HPL(City Vision)/ Jaquar(Premium)/Eveready/ Surya (Pollux) / FortuneArrt (Leaf) / Rhino(GPSL04) b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG
Design, Fabrication, Supply, Installation and Commissioning of Outdoor type timer box of size 600mm(W) x 600mm(H) x 300mm(D) and made with 14SWG CRCA sheet steel cleaning with 7 tank process and painting with powder coating. The box shall be made by provide rubber beeding, door knobs etc., and the front door with double leaf arrangement with hinges and locking arrangement. Suitable heat Dissipation / Air / Ventilation ducts with inside wire mesh shall be provide to the panel. The box base shall be mounted on 40x40x6mm MS angle with stand legs at 4 corners at a length of 700mm each of 40x40x6mm MS angle with necessary welding and the angles shall be painted with two coats of enamel black paint over one coat of red-oxide.
The timer box legs should be fixed in ground of size 400mm depth by using 20mm HBG metal in 1:3:6 ratio. A 9 Ply - 18 mm thick plywood sheet of size 0.50 m x 0.50m to fix inside the box and the following shall be supply and fix firmly on the ply wood sheet and giving necessary connections between Isolator - contactor - timer - out going MCBs etc., with suitable size of PVC copper wires /bus links and suitable holes to be made at bottom sheet of the box for incoming / outgoing cables and install the box at site as directed during execution by the site Engineer.
a) Incoming: 100 A FP Isolator - 1 No. b) Out Goings: 63 A 4-pole MCB - 2 Nos. c) LED indicator lamps - 3 Nos. d) ML - 4 3 Pole, 415 V Power Contactor L & T) - 1 No. e) Togele / 6 Amps 2 Way Switch and giving connections.- 1 No. f) Digital Time Switch (L & T) - 1 No. g) An earthing terminal should be provide to the box. h) Danger name plate -1 No. i) The ratings of switches, feeder name, bus bar / cable chamber etc., shall be indicate on panel with stickering letters as directed during execution.
Supply of 28 W, 1200 mm BLDC Ceiling Fan Sweep : 900 mm /1200 mm (36" / 48"), Rated Voltage : 230 V , Frequency : 48 - 52 Hz, Operating Voltage: 140-290v single phase AC. Power Factor : 0.99, Air Delivery : 235 CMM Rated Power : 28 W - 30 W, Motor Speed : 350 RPM with speed control, Bearing : Double Ball Bearing Down Rod Size :- 260 mm, Service Value :- 8.2 CMM/W, Operating temperature within 2 degree of ambient warranty :- 3 years on site, Speed Control : Regulator Compatible Conforming as per IS 374-2019 Latest. Model No : Atomberg - EFFICIO - 1200 mm (48") / Equivalent / TTD approved Brands Colour :- White / Ivory
Dismantling of the existing Ceiling fan / Exhaust fans/ wall mounting fans completely with accessories with out causing any damage to the fixtures etc., (Note: the dismantled above materials are to be returned to concerned section officer by the contractor at his cost)
(Rupees One crore seventy lakh fifty six thousand three hundred and thirty eight and paise sixty three only)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Approved-tender-conditions-NIt41.pdf
TENDER_DOCUMENT • 0.93 MB
Approved-BOQ.pdf
TENDER_DOCUMENT • 0.58 MB
BOQ NIT 63.xlsx
TENDER_DOCUMENT • 0.05 MB
Tender conditions- NIT-No 63.docx
TENDER_DOCUMENT • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .