Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | Qualified Make: EXIDE
Model: EXIDE TUBE MASTER TM500 L+ 12 VOLT 150 AH TUBULAR INVERTER BATTERY LIG 14 KOTRA SULTANABAD NEAR VAISHALI SQUARE TT NAGAR BHOPAL MADHYA PRADESH 462003 | BHOPAL | MADHYA PRADESH | 462003 | Make: EXIDE
Model: EXIDE TUBE MASTER TM500 L+ 12 VOLT 150 AH TUBULAR INVERTER BATTERY | - | Qualified | |
| 2 | L1₹52,800Disqualified Make: LUMINOUS
Model: LUMINOUS SC18054 MB 11A MANSAROVER COMPLEX HOSHANGABAD ROAD BHOPAL MADHYA PRADESH 462003 | BHOPAL | MADHYA PRADESH | 462003 | Make: LUMINOUS
Model: LUMINOUS SC18054 | L1 | Disqualified | |
| 3 | Disqualified Make: Okaya
Model: Okaya 150Ah Tubular Battery MAIN BUS STAND NEAR SYNDICATE BANK DHAULANA GHAZIABAD UTTAR PRADESH 245301 | HAPUR | UTTAR PRADESH | 245301 | Make: Okaya
Model: Okaya 150Ah Tubular Battery | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
14 Jul 2018, 2:00 pmClosed
lead acid battery Lead Acid Battery ( 4 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Stationary cells and Batteries
Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991 Statinary Lead-Acid Batteries (with tubular positive plates) in Monobloc Container conforming to IS:13369 1992
Stationary cells and Batteries
Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991 Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Fibre Reinforced Plastics (FRP) Fibre Reinforced Plastics (FRP) Rated Capacity at C20 discharge (AH) 150 Warranty (Years) 3 Years 1 Year
2 Years
3 Years
4 Years
5 Years Battery Condition Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 10000 - Weight of Dry Battery Yes. - 1/3 (Kg) shall be as per relevant IS: Specn.
corresponding Ah No.of cells per Battery (No.) 6 Cells for 12 Volt battery - CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab KOLKATA WEST BENGAL - Name of the Lab EXIDE INDUSTRIES LIMITED - Test Report No. 2511190 - Test Report Date 23/7/2017 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells
and for Batteries made from them for use in portable applications ISO 14001:2004 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Gautam Kumar Paul 799001
S.I.B.
35 H. G. Basak Road 4 15
318728
GEM/2018/B/45199
lead acid battery
15 days
Tripura; West Tripura
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| lead acid battery Lead Acid Battery ( 4 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Stationary cells and Batteries | - | - | - |
| Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991 Statinary Lead-Acid Batteries (with tubular positive plates) in Monobloc Container conforming to IS:13369 1992 | - | - | - |
| Stationary cells and Batteries | - | - | - |
| Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991 Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Fibre Reinforced Plastics (FRP) Fibre Reinforced Plastics (FRP) Rated Capacity at C20 discharge (AH) 150 Warranty (Years) 3 Years 1 Year | - | - | - |
| 2 Years | - | - | - |
| 3 Years | - | - | - |
| 4 Years | - | - | - |
| 5 Years Battery Condition Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 10000 - Weight of Dry Battery Yes. - 1/3 (Kg) shall be as per relevant IS: Specn. | - | - | - |
| corresponding Ah No.of cells per Battery (No.) 6 Cells for 12 Volt battery - CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab KOLKATA WEST BENGAL - Name of the Lab EXIDE INDUSTRIES LIMITED - Test Report No. 2511190 - Test Report Date 23/7/2017 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells | - | - | - |
| and for Batteries made from them for use in portable applications ISO 14001:2004 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Gautam Kumar Paul 799001 | - | - | - |
| S.I.B. | - | - | - |
| 35 H. G. Basak Road 4 15 | - | - | - |
Exempted
14 Jul 2018
11 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_318728.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .