| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.8 L+₹2.4 L (26.0%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹12.5 L
EMD Value
₹31,300
Closing Date
11 Nov 2019, 5:00 pmClosed
Managing Director
Kerala Medical Services Corporation Limited
SITC OF AIR CONDITIONER UNITS FOR DRUG STORE MODERNIZATION WORKS AT MCH,TRIVANDRUM
2019_KMSCL_314870_5
KMSCL/Projects/ET/2019
Open Tender
Civil Works - Buildings
Item Wise
90 days
MCH Thiruvananthapuram
Please refer tender document
8 documents required · 8 mandatory
₹2,950
Yes
online
₹31,300
Yes
9 Sept 2020
31 Oct 2019
15 Nov 2019
31 Oct 2019
11 Nov 2019
31 Oct 2019
Supply, installation, testing and commissioning (SITC) of 11 TR or higher capacity aircooled ductable split air conditioner with ceiling suspended IDU and all standard fittings, IDU SS drain pan, as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll compressor, electronic microprocessor pendant controller with digital display, first charge refrigerent gas, vibration isolator pads, structural supports for fixing IDU/ ODU as shown in the drawing, safety devices including thermal protector, pressure relief valve, over load relays single phase preventor etc, power wiring(max 3m from isolator) and control cabling(indoor to outdoor),thermostat wiring, high-low pressure cut out, suitable for three phase 440V supply etc complete as required
Supply, installation, testing and commissioning of suitable sized hard drawn copper refrigerant piping(both suction and liquid piping) including 25mm thick closed cell elastomeric insulation as per specification for 8.5 TR machine between indoor & outdoor units asper site conditions all complete.
Supply, installation, testing and commissioning of GSS sheet metal ducting for Air distribution network from indoor unit as per ducting specifications complete with angle flanges ,supports, GI rods , anchor bolts ,GI nuts and bolts, PVC/ rubber gaskets complete with all fittings , bends, transformations , vanes , splitter dampers ,inspection doors , plenums, channels, rods, anchor bolts, etc to roof /truss as per IS 655 . The job includes entire air distribution network and sizing of ducts also. Thickness 22 G
Supply, installation, testing and commissioning of GSS sheet metal ducting for Air distribution network from indoor unit as per ducting specifications complete with angle flanges ,supports, GI rods , anchor bolts ,GI nuts and bolts, PVC/ rubber gaskets complete with all fittings , bends, transformations , vanes , splitter dampers ,inspection doors , plenums, channels, rods, anchor bolts, etc to roof /truss as per IS 655 . The job includes entire air distribution network and sizing of ducts also. Thickness 24 G
Supply, installation, testing and commissioning of volume control duct damper made of extruded aluminium for ducts/collars to be provided with suitable links, lebers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution in the main duct complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications.
Supplying, fixing testing commissioning of Return air diffusers/Grills of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of supply air diffusers/grills extruded of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Providing and fixing of Acoustic Duct lining with 10mm thick nitrile rubber open cell type inside the ducts
Providing and fixing of Thermal insulation lining with 10mm thick fiberglass rigid board with adhesive, on supply duct using 9mm thick nitrile rubber closed cell type.
Supply and Fixing of Canvas connection and ribbed rubber pads as vibration isolators
Supply and Fixing of Heater Package with Humidistat and contactor for humidity control
Motorized volume control damper for individual operation of ductable split air conditioners
Supply, installation, testing and commissioning UPVC drain pipe 6kg/sq.cmof suitable dia connecting the drain pan of the indoor units to nearest drain point, with 12mm thick closed cell elastomeric insulation as per specification
Electrical Cabling between indoor and outdoor units, with required size cables/wires(Havells/RR Kabel/V-guard FRLS wires)
Electrical Cabling for incoming power supply to outdoor unit, with required size cables/wires(Havells/RR Kabel/V-guard FRLS wires)
Outdoor unit stand with ribbed rubber pads
Charges for cutting holes suitable for accommodating the supply ducts including plastering, colour washing etc. as required.
PIONEER COOLTECH
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .