Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTER SARU SECTION ROAD JAMNAGAR 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L1 | Accepted-AOC L1 | |
| 2 | L2₹25.0 L+₹1,726 (0.07%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹26.2 L+₹1.3 L (5.14%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹26.9 L+₹2.0 L (7.90%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance L4 |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
26 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Bhamre Kiran S
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No.1 Jamnagar 361 003
REPAIR / MAINTENANCE OF LT CABLES AND CONNECTED WORKS AT AF STATION JAMNAGAR
2020_MES_382605_2
8757/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No. 1
₹54,000
Yes
12 Jan 2021
12 Nov 2020
27 Nov 2020
12 Nov 2020
26 Nov 2020
12 Nov 2020
60 days
Amount
Taking out LT underground cable from trenches / pole etc, aluminium conductor of size 10 sqmm 2 core complete all as specified and directed by Engg-in-Charge.
Taking out LT underground cable from trenches / pole etc, aluminium conductor of size 16 sqmm 2 core complete all as specified and directed by Engg-in-Charge.
Taking out LT underground cable from trenches / pole etc, aluminium conductor of size 16 sqmm 4 core complete all as specified and directed by Engg-in-Charge.
Taking out LT underground cable from trenches / pole etc, aluminium conductor of size 25 sqmm 4 core complete all as specified and directed by Engg-in-Charge.
Taking out LT underground cable from trenches / pole etc, aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Taking out LT underground cable from trenches / pole etc, aluminium conductor of size 50 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Taking out LT underground cable from trenches / pole etc, aluminium conductor of size 70 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Taking out LT underground cable from trenches / pole etc, aluminium conductor of size 95 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Taking out LT underground cable from trenches / pole etc, aluminium conductor of size 120 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Taking out LT underground cable from trenches / pole etc, aluminium conductor of size 185 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Taking out LT underground cable from trenches / pole etc, aluminium conductor of size 240 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Taking out LT underground cable from trenches / pole etc, aluminium conductor of size 300 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Note : (Item No.1.00 to 12.00) Excavation and earth work and taking out old cable cover will be measured and paid separately.
Laying only old taken down LT underground cable from trenches / pole etc, aluminium conductor of size 10 sqmm 2 core complete all as specified and directed by Engg-in-Charge.
Laying only old taken down LT underground cable from trenches / pole etc, aluminium conductor of size 16 sqmm 2 core complete all as specified and directed by Engg-in-Charge.
Laying only old taken down LT underground cable from trenches / pole etc, aluminium conductor of size 16 sqmm 4 core complete all as specified and directed by Engg-in-Charge.
Laying only old taken down LT underground cable from trenches / pole etc, aluminium conductor of size 25 sqmm 4 core all as specified and directed.
Laying only old taken down LT underground cable from trenches / pole etc, aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Laying only old taken down LT underground cable from trenches / pole etc, aluminium conductor of size 50 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Laying only old taken down LT underground cable from trenches / pole etc, aluminium conductor of size 70 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Laying only old taken down LT underground cable from trenches / pole etc, aluminium conductor of size 95 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Laying only old taken down LT underground cable from trenches / pole etc, aluminium conductor of size 120 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Laying only old taken down LT underground cable from trenches / pole etc, aluminium conductor of size 185 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Laying only old taken down LT underground cable from trenches / pole etc, aluminium conductor of size 240 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Laying only old taken down LT underground cable from trenches / pole etc, aluminium conductor of size 300 sqmm 3.5 core complete all as specified and directed by Engg-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 10 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed by Engg-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 16 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed by Engg-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed by Engg-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed by Engg-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, ISI marked with aluminium multistranded conductor 1100 volt grade of size 35 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed by Engg-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 50 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed by Engg-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 70 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed by Engg-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 95 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed by Engg-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 120 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed by Engg-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 185 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed by Engg-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 240 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed by Engg-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 300 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed by Engg-in-Charge.
Excavation in trenches not exc 1.5 m wide and n.exc 1.5 m in depth for foundation / fixing of pole / laying of cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed by Engg-in-Charge.
Excavation in trenches not exc 1.5 m wide and n.exc 1.5 m in depth for foundation / fixing of pole / laying of cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in Hard/Rock/Rcc/Pcc soil complete all as specified and directed by Engg-in-Charge.
Returning filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick using excavated soil complete all as specified and directed by Engg-in-Charge.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point.
Taking out old PCC cable cover of any type / any size from trenches complete all as specified and directed by Engg-in-Charge.
Laying only PCC cable cover for HT / LT UG cable, of any description retrieved from item No 21, all as specified and directed by Engr-in-Charge.
Supply & lay ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV, flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable complete all as specified and directed by Engg-in-Charge.
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class HV , flat of size 300 mm X 180 mm X 40 mm in trenches as protection to HT UG cable complete all as specified and directed by Engg-in-Charge.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: For measurement purpose any punned thickness of sand will be considered.
Supply and laying GI tubing 40 mm dia bore light grade laid in trenches / floor / fixing on pole / wall for cable protection with necessary fittings etc. & taking down old tubing complete all as specified and directed by Engg-in-Charge.
Supply and laying in repair GI tubing 50 mm dia bore light grade laid in trenches / floor / fixing on pole / wall for cable protection with necessary fittings etc. & taking down old tubing complete all as specified and directed by Engg-in-Charge.
Supply and laying in repair GI tubing 80 mm dia bore light grade laid in trenches / floor / fixing on pole / wall for cable protection with necessary fittings etc. & taking down old tubing complete all as specified and directed by Engg-in-Charge.
Supply, jointing, connecting in repair and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 10 Sqmm suitable for 2 core all as specified and as directed by Engineer-In-Charge.
Supply, jointing, connecting in repair and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 16 Sqmm suitable for 2 / 4 core all as specified and as directed by Engineer-In-Charge.
Supply, jointing, connecting in repair and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 35 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 50 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 95 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 120 Sqmm complete all as specified and directed by Engg-in-Charge.
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 185 Sqmm complete all as specified and directed by Engg-in-Charge.
M&L for Boring under roads / pavement / hard standing without disturbing the top surface by trench less technology using ultra sound technique and necessary machine including supply & inserting HDPE pipe of 90 mm dia suitable for 0.4 mpa working pressure for passing through the cables complete all as specified and directed by Engg-in-Charge. Note : Necessary infrastructure required for boring shall be arranged by the Contractor at his own cost.
Earthing materials and Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanised mild steel strip 32 x 6 mm by means of bolts nuts check nuts and washer of.......
..........galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Note:- Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length
Supply and fix in repair MCCB 100 Amp, Four Pole, breaking capacity 16 KA, 415 V - 50 Hz, fixed thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 125 Amp, Four Pole, breaking capacity 16 KA, 415 V - 50 Hz, fixed thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 160 Amp, Four Pole, breaking capacity 16 KA, 415 V - 50 Hz, fixed thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 200 Amp, Four Pole, breaking capacity 35 KA, 415 V - 50 Hz, fixed thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 250 Amp, Four Pole, breaking capacity 35 KA, 415 V - 50 Hz, fixed thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 400 Amp, Four Pole, breaking capacity 36 KA, 415 V - 50 Hz, adjustable thermal and fixed magnetic setting type , fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repair MCCB 630 Amp, Four Pole, breaking capacity 50 KA, 415 V - 50 Hz, adjustable thermal and fixed magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed for service connections and other works two core cable flat or circular cable 2.5 Sq mm complete all as specified and directed by Engg-in-Charge.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed for service connections and other works two core cable flat or circular cable 4 Sq mm complete all as specified and directed by Engg-in-Charge.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed for service connections and other works two core cable flat or curcular cable 6 Sq mm complete all as specified and directed by Engg-in-Charge.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed for service connections and other works two core cable flat or curcular cable 10 Sq mm complete all as specified and directed by Engg-in-Charge.
M&L for heat shrinkable jointing kit indoor type suitable for 11 KV, along with complette accessories suitabhle for XLPE armoured aluminium cable of 95/120 Sq mm 3 core complete all as specified and directed by Engineer-in-Charge.
M&L for heat shrinkable jointing kit outdoor type suitable for 11 KV, along with complette accessories suitabhle for XLPE armoured aluminium cable of 95/120 Sq mm 3 core complete all as specified and directed by Engineer-in-Charge.
M&L for heat shrinkable jointing kit stright through type suitable for 11 KV, along with complette accessories suitabhle for XLPE armoured aluminium cable of 95/120 Sq mm 3 core complete all as specified and directed by Engineer-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, HT underground cable ISI marked with aluminium multistranded conductor 11000 volt grade of size 95 Sqmm 3 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed by Engg-in-Charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, HT underground cable ISI marked with aluminium multistranded conductor 11000 volt grade of size 120 Sqmm 3 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed by Engg-in-Charge.
Taking out HT underground cable from trenches / pole etc, aluminium conductor of size 95/120 sqmm 3 core complete all as specified and directed by Engg-in-Charge. Note : Excavation and earth work and taking out cable cover will be measured and paid separately.
Deployment of manpower and cable fault locator machine duly mounted on vehiclefor detection of HT UG cable fault of any size & make by pplying upto 15 KV supply to locate the fayult and and any necessary arrangements required contractor should be provided Note: HT cable fault not detected payment not to be paid by contracto.
Note: Item no 1 to 75 If any above HT/LT cables and connected items undergo breakdown, the contractor shall locate the problem/fault at site within 12 hours of intimation by JE/Engineer-In-Charge and ensure that the fault is rectified within 24 to 48 Hours, failing which an amount of Rs 200 /- per hour will be recovered as penal/recovery from many payment due to the contractor after expiry of 48 hours.
SURESH ELECTRICALS
Sukhi Electricals
jagdish machinery stores
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .