| Sl No | Description | Qty | Unit | B5BUILDING SOLUTIONS L1 | VIJAY CONSTRUCTIONS L5 | SHAIJAL T M L4 | Kurian And Varghese L2 | M.J.JOY AND COMPANY L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00Schedule 'A' Part-I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl item No. 1.01) is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Col 6. | ||||||||
| 1.01 | Lumpsum price worked out by the contractor for Construction of block of a (G+1) building for KG section to children school including all fittings and fixtures complete all as specified and as shown on drawings.
Notes: (i) Quoted rate against Sl item No. 1 includes cost of pile cap alongwith PCC below pile cap of pile foundation but does not include cost of pile, earth work excavation and site clearance which will be measured and paid separately under relevant items of Schedule 'A' Part-II.
(ii) Cost of piles will be measured and paid under Sl item No. 53 to 59 of Miscelleneous Schedule i.e., Schedule 'A' Part-XIII.
(iii) Necessary barricading shall be provided to the work site as directed by AGE(I). Quoted rate shall deemed to include the cost of same. | 1 | EACH BLOCK | 3,41,50,000 ₹3.4 Cr | 5,85,00,000 ₹5.8 Cr | 5,57,17,000 ₹5.6 Cr | 4,28,88,000 ₹4.3 Cr | 4,25,00,000 ₹4.3 Cr |
| 2.00 | Lump sum price worked out by the Contractor for “EXCAVATION AND EARTHWORK" as listed in Schedule ‘A’ Part - II representing __________ % __________________ percent Above / Below the lump sum price of `1,13,014.11 inserted by the MES in Schedule ‘A’ Part - II | 1 | LUMPSUM | 1,10,000 ₹1.1 L | 1,24,315 ₹1.2 L | 1,04,076 ₹1.0 L | 1,36,000 ₹1.4 L | 1,37,850 ₹1.4 L |
| 3.00 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - III representing __________ % ____________ percent Above / Below the lump sum price of `13,35,272.00 inserted by the MES in Schedule ‘A’ Part - III | 1 | LUMPSUM | 13,00,000 ₹13 L | 15,35,562 ₹15.4 L | 13,87,950 ₹13.9 L | 15,75,620 ₹15.8 L | 12,01,740 ₹12.0 L |
| 4.00 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of ₹1,24,251.94 inserted by the MES in Schedule ‘A’ Part - IV | 1 | LUMPSUM | 1,25,000 ₹1.3 L | 1,49,101 ₹1.5 L | 1,19,947 ₹1.2 L | 1,61,528 ₹1.6 L | 1,18,400 ₹1.2 L |
| 5.00 | Lump sum price worked out by the Contractor for “PATH / HARDSTANDING” as listed in Schedule ‘A’ Part - V representing ________ % ____________ percent Above / Below the lump sum price of ₹19,49,644.63 inserted by the MES in Schedule ‘A’ Part - V | 1 | LUMPSUM | 18,00,000 ₹18 L | 22,61,587 ₹22.6 L | 18,18,502 ₹18.2 L | 23,98,063 ₹24.0 L | 19,21,000 ₹19.2 L |
| 6.00 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - VI representing __________ % ____________ percent Above / Below the lump sum price of ₹4,65,304.70 inserted by the MES in Schedule ‘A’ Part - VI | 1 | LUMPSUM | 4,70,000 ₹4.7 L | 5,35,099 ₹5.4 L | 4,17,520 ₹4.2 L | 5,58,365 ₹5.6 L | 5,16,500 ₹5.2 L |
| 7.00 | Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part - VII representing _______ % _________________ percent Above / Below the lump sum price of `12,49,251.30 inserted by the MES in Schedule ‘A’ Part - VII | 1 | LUMPSUM | 11,25,000 ₹11.3 L | 14,36,639 ₹14.4 L | 12,32,080 ₹12.3 L | 14,74,118 ₹14.7 L | 12,16,300 ₹12.2 L |
| 8.00 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VIII representing _________ % __________________ percent Above / Below the lump sum price of `1,28,742.35 inserted by the MES in Schedule ‘A’ Part - VIII | 1 | LUMPSUM | 1,35,000 ₹1.4 L | 1,54,490 ₹1.5 L | 1,17,820 ₹1.2 L | 1,54,490 ₹1.5 L | 1,57,000 ₹1.6 L |
| 9.00 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - IX representing __________ % _________________ percent Above / Below the lump sum price of ₹48,858.00 inserted by the MES in Schedule ‘A’ Part - IX | 1 | LUMPSUM | 50,000 ₹50,000 | 53,743 ₹53,743 | 53,682 ₹53,682 | 57,000 ₹57,000 | 48,600 ₹48,600 |
Updated dates
Tender Value
₹6.3 Cr
EMD Value
₹6.4 L
Closing Date
28 Oct 2025, 6:00 pmClosed
CHIEF ENGINEER RND SECUNDERABAD
CHIEF ENGINEER RND SECUNDERABAD PICKET OPP JUBILEE BUS STATION SECUNDERABAD 500003
PROVISION OF BUILDING FOR KG SECTIONS OF CHILDREN SCHOOL AT NPOL, KOCHI
2025_MES_728406_1
86137
Open Tender
Civil Works
450 days
KOCHI
Class A
category a(i)
8 documents required · 8 mandatory
₹3,000
ASST GARRISON ENGINEER I RND KOCHI
₹6.4 L
Yes
24 Dec 2025
29 Aug 2025
31 Oct 2025
29 Aug 2025
28 Oct 2025
1 Oct 2025
Amount
Schedule 'A' Part-I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl item No. 1.01) is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Col 6.
Lump sum price worked out by the Contractor for “EXCAVATION AND EARTHWORK" as listed in Schedule ‘A’ Part - II representing __________ % __________________ percent Above / Below the lump sum price of `1,13,014.11 inserted by the MES in Schedule ‘A’ Part - II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - III representing __________ % ____________ percent Above / Below the lump sum price of `13,35,272.00 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of ₹1,24,251.94 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for “PATH / HARDSTANDING” as listed in Schedule ‘A’ Part - V representing ________ % ____________ percent Above / Below the lump sum price of ₹19,49,644.63 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - VI representing __________ % ____________ percent Above / Below the lump sum price of ₹4,65,304.70 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part - VII representing _______ % _________________ percent Above / Below the lump sum price of `12,49,251.30 inserted by the MES in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VIII representing _________ % __________________ percent Above / Below the lump sum price of `1,28,742.35 inserted by the MES in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - IX representing __________ % _________________ percent Above / Below the lump sum price of ₹48,858.00 inserted by the MES in Schedule ‘A’ Part - IX
Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION” as listed in Schedule ‘A’ Part - X representing __________ % _________________ percent Above / Below the lump sum price of ₹1,78,042.75 inserted by the MES in Schedule ‘A’ Part - X
Lump sum price worked out by the Contractor for “TV / TELEPHONE / LAN” as listed in Schedule ‘A’ Part - XI representing __________ % _________________ percent Above / Below the lump sum price of ₹1,45,024.00 inserted by the MES in Schedule ‘A’ Part - XI
Lump sum price worked out by the Contractor for “FIRE ALARM & DETECTION SYSTEM” as listed in Schedule ‘A’ Part - XII representing _________% ___________________ percent Above / Below the lump sum price of ₹1,46,156.00 inserted by the MES in Schedule ‘A’ Part - XII
Schedule 'A' Part-XIII This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 14.00 to 59.00.
INTERNAL ELECTRIFICATION S&F, LED light fittings 1 x 20 W, 4 ft, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed.
S&F, LED light fittings 1 x 10 W, 2 ft, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed.
S&F, LED building security light fittings 35 Watts, 230 Volts, AC outdoor type high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant including thermal management in multiple optics complete with IP-66 protection and GI pipe 1.5m bend to shape to fix in wall through proper clamps, nuts, bolts with washers connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F, exhaust fan heavy duty steel body 300mm sweep, 230 volts, 50 Hz, 1200 RPM including louvers shutter, copper wire complete all as specified and directed.
S&F, exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230 volts, 50 Hz, 1200 RPM, copper wire and sweep 250mm complete all as specified and directed.
S&F, wall fan 400mm double strings oscilating type 220/240 Volts, 50 Hz, single phase AC 1350 RPM copper motor PF 0.9 (min) not more than 65 Watts air delivery not less than 65 mm as per site requirement as required complete all as specified and directed.
TV / TELEPHONE / LAN S&F, modular type LAN socket RJ 45 CAT 6 connector complete all as specified and directed.
INTERNAL WATER SUPPLY S&F, (SWR) PVC pipes 110mm dia single socketed in any length with rubber ring joints laid under floor or on walls fixed as soil waste / vent pipes complete all as specified and directed.
S&F, (SWR) PVC pipes 75mm dia single socketed in any length with solvent cement joints laid under floor or on walls fixed as soil waste / vent pipes complete all as specified and directed.
S&F, PVC (SWR) bends any radius, 110mm bore with access door complete all as specified and directed.
S&F, 75mm dia outlet cast iron nahani trap with grating complete all as specified and directed.
SEWAGE DISPOSAL Provision of LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below the vent shaft connection for 200 users complete all as specified and directed.
M&L for provision of soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25 / SFRC cover, interconnecting pipes of RCC / DWC complete filled with brick bats of size 3.6m dia x 6.00m effective depth complete all as specified and directed.
Construction of brick masonary valve pit of internal dimension 60 x 60 x 60 cm depth with sub class 'B' bricks in CM 1:4 and 10mm thick plastering in CM 1:4, PCC 1:4:8, type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, PCC 1:4:8, type C1 (using 20mm graded broken stone aggregate) as in bedding and coping MS frame with 40 x 40 x 6mm angle iron and 6mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, two coats of white wash on plastered surface (exposed to view) including necessary excavation in soft / loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as specified and directed.
Cutting of PCC / hard standing / WBM road not exceeding 45cm in width not exceeding 75 cm in depth for passing of LT cable and making good disturbed surface to match with the existing surfaces by using old and new material i.e. bitumen / PCC 1:3:6, type C1 complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply, install, test & commissioning of out door type LT feeder piller box made out of 3.15 mm thick CRCA sheet out door type totally enclosed weather dust and vermin proof as per IS, CPRI approved with front opening suitable locking arrangement having copper bus bar of 225 Amps capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC 1:3:6 in foundation and made out of 50 mm x 50 mm x 6 mm angle iron grouted at ground above 30 cm from ground level comprising of the following complete all as specified and directed by Engineer-in-Charge.
Note: Cost of necessary internal wiring from bus bar to MCCBs / MCBs / enclosure connections etc shall be deemed to be included in the unit rate. Incoming: (a) MCCB 160 A, 4 P, 415 Volt, 36 kA, Ics = 100% of Ics with spreader & rom - 01 No. (b) Indicating Lamp Red / Yellow / Blue - 03 Nos. (c) SP MCB 6 A - 03 Nos. (d) MFM Meter with CT - 01 No. Outgoings (a) 125 A, 4P MCCB, 415 Volt, 36 kA, Ics = 100% of Ics with spreader & rom - 01 No. (b) 63 A, 4P MCCB, 415 Volt, 25 KA, Ics = 100% of Ics with spreader & rom - 01 No. (c) 40 A, 4P MCB 415 Volt, 16 KA, Ics = 100% of Ics with spreader & rom - 01 No. (d) 16 A, 4P, 230 Volt, 10KA MCB - 01 No.
M&L for extending the extisting LT panel board at substation VI with 2 mm thick CRCA sheet factory made indoor type totally enclosed weather dust and vermin proof as per IS, CPRI approved with front and rear opening suitable locking arrangement with necessary copper bus bar of capacity 300 Amps with necessary supporting insulators so as to match with the existing LT panle board / distribution panel by connecting to existing bus bar by using rigid copper bus bar by opening the one side of existing panel / bus bar including necessary supporting frame / channel fix through existing cable trench from ground with comprising of the following: - (a) MCCB 200 Amp, 4 Pole, 36KA, Ics-100% of Icu - 01 No. (b) Provision for outgoing cable of size upto 120 sq mm from the extended portion of LT distribution panel.
Supplying, laying, testing & commissioning of LT XLPE cables, insulated, screened, PVC bedded, galvanized steel stranded armoured, electric power cable (heavy duty) with aluminium conductor, 1100 Volt graded of 120 Sqmm 3.5 core cross sectional area laid in trenches complete all as specified and directed.
Supplying, laying, testing & commissioning of LT XLPE cables, insulated, screened, PVC bedded, galvanized steel stranded armoured, electric power cable (heavy duty) with aluminium conductor, 1100 Volt graded of 35 Sqmm 3.5 core cross sectional area laid in trenches complete all as specified and directed.
Supplying, laying, testing & commissioning of LT XLPE cables, insulated, screened, PVC bedded, galvanized steel stranded armoured, electric power cable (heavy duty) with aluminium conductor, 1100 Volt graded of 16 Sqmm 4 core cross sectional area laid in trenches complete all as specified and directed. Note for Sl item Nos. 34 to 36: (i) Rate include the cost of lug of proper size and cable gland. (ii) Necessary excavation, PCC cover, and sand cushioning shall be measured and paid separately.
S&F, sand for cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable complete all as specified and directed. Note: Punned thickness shall be taken for measurement.
M&L for laying LV unreinforced precast concrete cable cover but type 1, flat size 250mm x 150mm x 40mm ISI marked perpendicular to cable for protection complete all as specified and directed.
Demolition of PCC / hard standing floor inside the substation / E/M installtions / path in any position for laying of cables of any size complete all as specified and directed.
M&L for PCC 1:4:8, type D2 40 mm graded aggregate complete for making good to the excavated portion of road / hard standing at road crossing complete all as specified and directed.
S&F, cable route indicator with 10cm x 10cm x 5mm thick GI plate with insemption HT/LT cable there on, bolted / welded to 35 x 35 x 6mm thick angle iron, 60cm long duly painted with two coats of synthetic enamel paint over a coat of primer and fixing the same in ground in PCC 1:3:6 type C1 block 40 x 40 x 40cm and indicator shall be 20cm above ground level complete all as specified and directed.
S&F, trenches / fixed on wall GI tubing light grade with necessary fittings such as bend, tee, elbow etc., complete for 80mm bore for protection of LT UG cable complete all as specified and directed.
S&F, GI tubing 50mm bore light grade fixed on wall or laid in trenches with necessary fittings such as bend, tee, elbow etc., complete for protection of LT UG cable complete all as specified and directed.
Supply of 200 Watts flood light with die cast aluminum housing, secondary peanut lense with toughened glass diffuser, LED of High power OSRAM / CREE / LUMILED / BRDIGELUX, luminaire efficiency of >110Lm/W; the product should be with IP 66; THD 0.95; CCT of 5700K, internal surge protection 4 KV, driver of BIS potted driver with IS standard, Brand name should be embossed on product for long life identification. The luminaire shall guarantee upto 50,000 burning hours as per L70 & LM80 reports. TDS & LM79 Reports shall be furnished confirming as per Engineer-in-Charge and including light is to be fixed on pole with necessary supporting clamps and nut & bolts etc., complete all as specified and directed.
S&F, steel tubular swaged pole complete with cast iron base plate, final taper plug, bolts & screws as specified type 410 SP-31 type (9.0 Metre long), complete, pole cap, bolts, nuts and washers etc., pole confirming to IS 2713 Part-II, including drilling holes, painting with two coats of bituminous paint both internally and externally in embedded portion of the pole in ground / concrete painting to exposed surface with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F, transparent cover type street light junction box of size 168 mm x 253 mm x 115 mm made of high quality thermoplastic type with hinged and 04 Nos DIN mounted terminal suitable for 10 Sqmm XLPE cable, IP-66 (dust and power jet proof according to IEC 60529), shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated (Class II) made of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper bus bar 25 x 5 mm - 04 strip, 01 No MCB SP 6 Amps with locking arrangement and 02 Nos M-40 size cable gland and one M-32 size gland suitable upto, 10 Sqmm cable etc and fixing to the street light pole with 02 Nos, 25 x 3 mm thick MS clapms, nuts & bolt etc., complete all as specified and directed.
S&F, Bollard luminaire die cast housing and clear acrylic of IP 65 protection Inverted Tripod type, resistance to corrsion of 10 Watt with LED lamp with all fixing arrangements fixed with soft 360 deg light distribution complete all as specified and directed.
LIGHTNING PROTECTION S&F, aluminium strip 20 x 3.15 mm thick on parapet or surface wall complete with saddles and fixing screws for roof / down conductor on porcelain / epoxy spacer insulators complete all as specified and directed.
FIRE ALARM & DETECTION SYSTEM Supply, install, testing & commissioning of Single Loop addressable main fire alarm panel, with 99 detectors and 99 modules and upto 200 detectors and modules per loop. The panel is to be installed in non air-conditioned environment and shall be suitable for the atmosphere with humid condition operate on 230 V AC, 50 Hz and shall provide all necessary power for the control panel. In the event of a mains electrical failure, the fire alarm control panel shall have the capability of being supported in its intended state by standby batteries. The fire alarm control panel shall be fitted with an integral 0.7 Amp battery charger, current limited with DDP for 24 V lead acid batteries. The battery charger must be capable of being up-graded in capacity to facilitate larger system complete all as specified and directed.
S&F, 2 x 1.5 sqmm fire survival armoured cable, 600/1000 V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable ethylene rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required, drawn through 25 mm dia steel conduit complete all as specified and directed.
Supply, install, testing & commissioning of multisensor detectors with smoke and heat combination complying with type certified to EN-45 / UL listed addressable type photoelectric / optical with base with self built intelligence as per IS 11360 complete all as specified and directed.
Supply & installing of wall / ceiling mounted 3 W double sided LED EXIT signage luminaire lit up using regular mains supply and 2 hours backup battery supply complete all as specified and directed.
WATER COOLER AND REFRIGERATION Supply, install, test & commissioning of water cooler fully stainless steel electric driven single phase, 230V, 50Hz having storage capacity of 80 litres and nominal cooling capacity of 40 litres complete all as specified and directed.
Supply & install, voltage stabiliser for automatic operation, single phase, naturally cooled indoor type and designed for input variation between 170 V to 250V with output voltage stabilised at 230 Volt with accuracy of +2.5% and of capacity 1 KVA complete all as specified and directed.
PILE FOUNDATION Boring of cast-in-situ bored pile of 700mm dia to any depth through any type of soil / strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land complete all as specified and directed. Note: The rate shall include mobilisation, erection, dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
M&L for reinforced cement concrete of grade M-30 design mix as per IS-456 using 20mm graded stone aggregate in piles of 700mm dia from cut off level complete all as specified and directed.
M&L for TMT bars in reinforcement 10mm dia and over including cut to length, bend to required shape, cranking / hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position / required shape complete all as specified and directed.
M&L for TMT bars in reinforcement 5mm dia and over upto and including 10mm dia confirming to IS-1786 as in stirrups cut to length, bend to required shape, cranking / hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position / required shape complete all as specified and directed.
Testing of piles (Initial load test) all as per IS-2911 for 700mm dia for DMC piles including removing the testing equipment form the site after testing complete all as specified and directed.
Testing of piles (Routine load test) all as per IS-2911 for 700mm dia for DMC piles including removing the testing equipment form the site after testing complete all as specified and directed.
Conducting standard penetration test all as per IS-2131 at levels and locations for 700mm dia pile complete all as specified and directed.
Kurian And Varghese (BID ID -3445540)
M.J.JOY AND COMPANY (BID ID -3450383)
SHAIJAL T M (BID ID -3445418)
VIJAY CONSTRUCTIONS (BID ID -3444963)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.50 MB
86137Tender.pdf
Tender Documents • 1.72 MB
Drawings1.rar
Additional Documents • 1.88 MB
Drawings3.rar
Additional Documents • 1.03 MB
86137Prepricedschedules.pdf
Additional Documents • 0.31 MB
Drawings.rar
Additional Documents • 0.44 MB
Structural_1.pdf
Additional Documents • 7.00 MB
BOQ_815437.xls
BOQ • 0.64 MB
Download all tender documents and submit your bid