Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹5.9 Cr
EMD Value
₹5.9 L
Closing Date
30 Oct 2026, 11:00 am7d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
NBCC Bhawan
NBCC Bhawan
Construction of Centre of Excellence building including Civil,Electrical , Plumbing and others Internal and External services for ICMAI at Sitapura,Jaipur(Rajasthan)
NBCC/CGM/SBG-GUJ-MP-RAJ/ICMAI/NIT/2026/19~EWb4670f050673e36b362d0219
NBCC/CGM/SBG-GUJ-MP-RAJ/ICMAI/NIT/2026/19
Open Tender-Domestic
Civil Works General
NBCC Bhawan
₹11,800
₹5.9 L
15 Oct 2026
15 Oct 2026
30 Oct 2026
15 Oct 2026
30 Oct 2026
ICMAI BOQ Final
Name of work : Construction of Centre of Excellence building , ICMAI ,Jaipur Rajasthan
S.No Particulars a
1 Earth Work 1,814,611.72
2 Concrete Work 766,225.20
3 Reinforced Cement Concrete 24,329,318.95
4 Masonry Work 3,793,505.90
5 Cladding Work 100,155.61
6 Wood & PVC Work 754,224.98
7 Steel Work 970,957.76
8 Flooring 3,323,218.81
10 Finishing 3,104,881.13
11 Aluminium Work 343,076.00
12 Water Proofing 92,352.00
13 Road Work 365,537.20
14 Miscelinious 3,464,115.69
TOTAL AMOUNT (DSR) 41,093,006
TOTAL AMOUNT (DSR) 41,093,006
TOTAL AMOUNT (NON DSR) 3,464,116
TOTAL AMOUNT (NON DSR) 3,464,116
GRAND TOTAL (CIVIL WORKS) (In Rs) (A) 44,557,121.54
GRAND TOTAL (CIVIL WORKS) (In Rs) (A) 44,557,121.54
PLUMBING & EXTERNAL WORK
15 Sanitary Installations 347,688.05 522,207.81
16 Internal Drainage Installations 894.50 -
17 Water supply Installations 460,541.75 -
18 External Sewage Drainage System 1,363,133.25
19 External Storm Water Drainage System 5,486.49
TOTAL AMOUNT (DSR) 2,766,800.19
TOTAL AMOUNT (DSR) 2,766,800.19
TOTAL AMOUNT (NON DSR) 522,207.81
TOTAL AMOUNT (NON DSR) 522,207.81
Digitally signed by NIRAJ
Name of work : Construction of Centre of Excellence building , ICMAI ,Jaipur Rajasthan
S.No Particulars a
GRAND TOTAL (PLUMBING & EXTERNAL WORK)
GRAND TOTAL (PLUMBING & EXTERNAL WORK)
ELECTRICAL WORKS (Internal)
21 INTERNAL ELECTRICAL 2824640.00 2601322.00
24 Fire Alarm System 757,027.00 49,826.95
TOTAL AMOUNT (DSR) 5,797,033.72
TOTAL AMOUNT (DSR) 5,797,033.72
TOTAL AMOUNT (NON DSR) 2,935,912.55
TOTAL AMOUNT (NON DSR) 2,935,912.55
GRAND TOTAL 8,732,946.27
GRAND TOTAL 8,732,946.27
GRAND TOTAL (ELECTRICAL WORKS INTERNAL)
GRAND TOTAL (ELECTRICAL WORKS INTERNAL)
ELECTRICAL WORKS (External)
25 EXTERNAL FEEDER LINE 60592.00 687832.00
26 EXTERNAL SUB STASTION 647591.00 237130.60
27 EXTERNAL LT DISTRIBUTION LINE 376592.00 364269.60
TOTAL AMOUNT (DSR) 1,099,031.00
TOTAL AMOUNT (DSR) 1,099,031.00
TOTAL AMOUNT (NON DSR) 1,565,346.20
TOTAL AMOUNT (NON DSR) 1,565,346.20
GRAND TOTAL (ELECTRICAL WORKS EXTERNAL)
GRAND TOTAL (ELECTRICAL WORKS EXTERNAL)
TOTAL(A+B+C+D) 59,243,453.01
Digitally signed by NIRAJ
SCHEDULE OF QUANTITIES
Name of work : Construction of Centre of Excellence building , ICMAI ,Jaipur Rajasthan
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over
1 2.6 areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out
and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas
2 2.7 (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and -
disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed by Engineer-in-charge.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in
3 2.25 layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and Cum 1,368.87 196.00 268,298.52
watering, lead up to 50 and for all lift.
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical
transport upto a lead of 5km also including ramming and watering of the earth in layers not
4 2.25 (a) exceeding 20cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. Cum 1,500.00 700.50 1,050,750.00
Supplying and filling in plinth with sand under floors, including watering, ramming,
consolidating and dressing complete.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of
6 2.31 girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a Sqm 3,000.00 17.60 52,800.00
distance of 50m outside the periphery of the area cleared.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL
anti-termite treatment (excluding the cost of chemical emulsion) :
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Treatment of soil under existing floors using chemical
emulsion @ one litre per hole, 300 mm apart including drilling
12 mm diameter holes and plugging with cement mortar 1 :2
(1 cement : 2 Coarse sand) to match the existing floor:
With Chlorpyriphos/Lindane E.C. 20% with 1%
Total of sub-head (1.0) 1,814,611.72
2 Concrete Work -
Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level :
1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources: 10 graded stone
aggregate 40 mm nominal size derived from natural sources)
4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) Cum 70.00 6,812.00 476,840.00
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2
9 4.10 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 12.5mm nominal Sqm 38.00 410.85 15,612.30
size derived from natural sources)
Providing and fixing up to floor five level precast cement concrete string or lacing courses,
10 4.5 copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., -
including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand),
cost of required Centering complete.
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone
aggregate 20 mm nominal size derived from natural sources)
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality
11 4.13 using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and Sqm 38.00 146.15 5,553.70
finally with a piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-
III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from
12 4.17 natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed Sqm 70.00 749.30 52,451.00
and consolidated and grouted with fine sand, including necessary excavation, levelling &
dressing & finishing the top smooth.
Total of sub-head (2.0) 766,225.20
3 Reinforced Cement Concrete -
13 5.9 Centering and shuttering including strutting, propping etc. and removal of form for : -
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
5.9.1 Foundations, footings, bases of columns, etc. for mass concrete Sqm 400.00 392.15 156,860.00
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 Suspended floors, roofs, landings, balconies and access platform Sqm 980.00 927.25 908,705.00
5.9.4 Shelves (Cast in situ) Sqm 30.00 927.25 27,817.50
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers Sqm 950.00 736.40 699,580.00
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 900.00 961.30 865,170.00
5.9.7 Stairs, (excluding landings) except spiral-staircases Sqm 400.00 764.95 305,980.00
Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string
courses, bands, copings, bed plates, anchor blocks and the like
5.9.19 Weather shade, Chajjas, corbels etc., including edges Sqm 100.00 951.10 95,110.00
5.9.16 Edges of slabs and breaks in floors and walls.
5.9.16.1 Under 20 cm wide metre 300 208.55 62565
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position
and binding all complete upto plinth level.
5.22.A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 40,200.00 107.85 4,335,570.00
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position
and binding all complete above plinth level.
5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 60,200.00 107.85 6,492,570.00
15 5.30 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. Metre 300.00 78.40 23,520.00
Add for using extra cement in the items of design mix over and above the specified cement
content therein.
Providing and laying in position ready mixed or site batched design mix cement concrete for
reinforced cement concrete work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve
durability and workability without impairing strength; including pumping of concrete to site of
16 5.33 laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and - -
reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix
shall be payable separately. In case the cement content in design mix is more than 1.10
times of the specified minimum cement content, the contractor shall have discretion to
either re-design the mix or bear the cost of extra cement.
5.33.1 All works upto plinth level - -
5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum Cum 374.41 9,504.75 3,558,673.45
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Concrete of M30 grade with minimum cement
content of 350 kg /cum
5.33.2 All works above plinth level upto floor V level. - -
Concrete of M25 grade with minimum cement
content of 330 kg /cum
Concrete of M30 grade with minimum cement
content of 350 kg /cum
Total of sub-head (3.0) 24,329,318.95
4 Masonry Work -
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in 0
foundation and plinth in:
6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 110 7132.25 784547.5
6.4 Brick work with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in superstructure above plinth level up to floor V level in
all shapes and sizes in:
6.4.2 Cement mortar 1:6 (1 cement: 6 coarse sand) cum 50 9105.95 455297.5
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks
of class designation 7.5 in superstructure above plinth level up to floor
6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand) sqm 65 1150.5 74782.5
6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half sqm 65 104.8 6812
6.44 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non Mtr 207 59.45 12306.15
modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4
6.38 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry cum 135 10195.45 1376385.75
100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650
kg/cum conforming to IS:2185 (Part 3) in super structure above plinth
level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ).
The rate includes providing and placing in position 2 Nos 6 mm dia M.S.
bars at every third course of masonry work.
6.47 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 cum 130 8333.65 1083374.5
mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3)
in super structure above plinth level up to floor V level with RCC band at sill level and lintel level
with approved block laying polymer modified adhesive mortar all complete as per direction of
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Total of sub-head (4.0) 3,793,505.90
5 Cladding Work -
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished,
machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of
18 8.2 required size, approved shade, colour and texture laid over 20 mm thick base cement mortar -
1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment,
epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss
finish etc. complete at all levels.
8.2.2 Granite of any colour and shade -
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and
19 8.4 drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. Metre 5.00 568.55 2,842.75
Mirror polishing on marble work/Granite work/stone work where ever
required to give high gloss finish complete.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm
deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with
21 8.10 chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete - -
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction
of Engineer-in-charge and finished smooth.
8.10.2 Granite Stone of approved shade SQM 4.86 4,051.00 19,687.86
Total of sub-head (5.0) 100,155.61
6 Wood Work & PVC Work -
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-
decorative type, core of block board construction with frame of 1st class hard wood and well
22 9.21 matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on -
both faces of shutters:
9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Sqm 45.00 2,392.65 107,669.25
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold
fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Second class teak wood
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges
of flush door shutters (over all area of door shutter to be measured).
24 9.26 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). Sqm 18.00 106.70 1,920.60
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25 mm with
25 9.46 two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., -
wherever necessary complete :
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats,
square or round bars etc. including priming coat with approved steel primer all complete
9.48.1 Fixed to steel windows by welding kg 264.60 219.10 57,973.86
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass
excluded) (overall area of door shutter to be measured):
9.24.1 Rectangular or square Sqm 1.00 199.15 199.15
Providing and fixing bright finished brass night latch of approved quality including necessary
screws etc. complete.
Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer
particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll),
29 9.129 having one side decorative lamination and other side balancing lamination, including IInd class Sqm 22.68 2,307.35 52,330.70
teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished
stainless steel piano hinges, complete as per direction of the Engineer-in-Charge
Providing and fixing 25 mm thick pre-laminated medium density fibre board exterior grade
(Grade-I) IS:14587:1998 marked with one side decorative and other side balancing lamination
30 9.159 for cupboard shutters edges to be sealed with PVC edge bending tape 2.00 mm thick of Sqm 22.68 2,135.25 48,427.47
approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming
to IS:3818 marked with necessary screw etc all complete.
Providing and fixing special quality bright finished brass cupboard or ward robe locks with four
levers of approved quality including necessary screws etc. complete.
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Providing and fixing 50 mm bright finished brass cup board or wardrobe knob of approved
quality with necessary screws.
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters,
including fixing with necessary screws etc. complete.
9.114.1 Triple strip vertical type Each 120.00 52.50 6,300.00
9.114.2 Double strip (horizontal type) Each 48.00 39.70 1,905.60
Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary
screws etc. complete as per directions of Engineer- in-charge.
Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter with stainless
35 9.116 steel rollers to run inside C or E aluminium channel section (The payment of C or E channel Each 96.00 20.40 1,958.40
shall be made separately)
Providing and fixing in wall lining medium density fibre board IS: 14587:1998 marked, Pre-
36 9.158 laminated one side decorative lamination and other side balancing lamination, with necessary
fixing arrangement and screws etc. complete.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/
37 9.127 suede finish with high density protective surface layer and reverse side of adhesive bonding
quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
Total of sub-head (6.0) 754,224.98
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with
38 10.15 rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and -
grinded finish, with profiles of required size, including fixing of necessary butt hinges and
screws and applying a priming coat of approved steel primer.
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C.
1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates
etc., including welding, grinding, buffing, polishing and making curvature (wherever required)
and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing
39 10.28 with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of kg 700.00 772.40 540,680.00
required size, on the top of the floor or the side of waist slab with suitable arrangement as per
approval of Engineer-incharge, (for payment purpose only weight of stainless steel members
shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Steel work welded in built up sections/ framed work, including cutting,
40 10.25 hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets,
gates and similar works
Total of sub-head (7.0) 970,957.76
Providing and laying full body (Homogeneous) Vitrified floor tiles in different sizes (thickness to
be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:
41 11.41 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 - -
cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the
joints with white cement and matching pigments etc., complete.
11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as
well as curvilinear portions of the building all complete as per the architectural drawings with 18
mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse
sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with
pigment of matching shade including rubbing , curing and polishing etc. all complete as
specified and as directed by the Engineer-in-Charge.
11.56.2 Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red Sqm 200.00 3,071.05 614,210.00
Providing and laying full body (Homogeneous) Vitrified tiles in different sizes (thickness to be
specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S.
42 11.46 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed - -
of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm
including grouting the joint with white cement & matching pigments etc. complete.
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the
manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved
brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1
43 11.41A cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the - -
joints with white cement and matching pigments etc. The tiles must be cut with the zero
chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge,
clips of required thickness, leveling system and rubber mallet for placing the tiles gently and
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size - -
11.4 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300
mm or more (thickness to be specified by the manufacturer), of 1st quality
conforming to IS : 15622, of approved make, in all colours, shades,
except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Sqm 200.00 287,880.00
Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @
3.3 kg/ sqm including pointing the joints with white cement and matching
pigments etc., complete.
8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be
specified by the manufacturer), of approved make, in all colours, shades except burgundy,
bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and Sqm 250.00 316,987.50
dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with
grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of
matching shade complete.
14.88 Providing and laying in situ seven course water proofing treatment with
APP (Atactic Polypropylene) modified Polymeric memberane over roof
consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th
& 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of
blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th
layers of roofing membrane APP modified Polymeric membrane 2.0 mm
thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with Sqm 100.00 85,570.00
centre core as 100 micron HMHDPE film sandwiched on both sides with
polymeric mix and the polymeric mix is protected on both side with 20
micron HMHDPE film. 7th, the top most layer shall be finished with brick
tiles of class designation 10 grouted with cement mortar 1:3 (1 cement : 3
fine sand) mixed with 2% integral water proofing compound by weight of
cement over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand) 855.7
Total of sub-head (8.0) 3,323,218.81
9 Roofing - -
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone
44 12.21 aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine - -
sand) as per standard design :
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m
45 12.22 x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a Each 6.00 298.25 1,789.50
coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water
46 12.41 pipes conforming to IS : 13592 Type A, including jointing with seal ring - -
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)
Single socketed pipes
Providing and fixing on wall face unplasticised - PVC moulded fittings/
47 12.42 accessories for unplasticised Rigid PVC rain water pipes conforming to IS - -
: 13592 Type A, including jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion
12.42.1 Coupler - -
12.42.2 Single pushfit Coupler - -
12.42.4 Single tee without door - -
12.42.6 Shoe (Plain) - -
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC
48 12.43 rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of - -
required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4
coarse sand) and making good the wall etc. complete.
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true
horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (
galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably
spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum)
sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm
thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to
form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm
49 12.52 made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel -
to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of
approved texture in the grid including, required cutting/making, opening for services like
diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended
from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia
and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of
size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width
of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights
as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and
0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides
12.52.2 inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction sqm 600.00 2,068.75 1,241,250.00
Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns
(minimum), including factory painted after bending and perforation and backed with a black
Glass fiber acoustical fleece.
Total of sub-head (9.0) 1,334,940.60
10 Finishing -
50 13.4 12 mm cement plaster of mix -
51 13.5 15 mm cement plaster on rough side of single or half brick wall of mix: - -
52 13.16 6 mm cement plaster of mix - -
53 13.18 Neat cement punning Sqm 52.39 79.95 4,188.58
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Extra for providing and mixing water proofing material in cement plaster work in proportion per bag of
recommended by the manufacturers. 50kg
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to
prepare the surface even and smooth complete.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile
56 13.83 Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, - -
including applying additional coats wherever required to achieve even shade and colour.
13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster
1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement
plaster 1:6 (1 cement : 6 fine sand).
13.47.1 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required sqm 1200 171.1 205320
shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including
priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted)
57 13.48A having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal - -
resistance, dirt resistance exterior paint of required shade with silicon additives.
New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of
13.48A.1 exterior primer applied @ Sqm 911.20 181.25 165,155.00
0.90 litre/10 sqm.
58 13.50 Applying priming coat: - -
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel
galvanised iron/ steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
13.61.1 Two or more coats on new work Sqm 62.51 155.90 9,745.00
Total of sub-head (10.0) 3,104,881.13
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
11 Aluminium Work -
Providing and fixing aluminium work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/ appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia
and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with
required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,
straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium
snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per
architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash
21.1.1 fasteners
For to be paid for separately) :
fixed portion -
21.1.1.2 Powder coated aluminium (minimumthickness of powder coating 50 micron) KG 200.00 530.90 106,180.00
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and
21.1.2 making provision for fixing of fittings wherever required including the cost of EPDM rubber / -
neoprene gasket required (Fittings shall be paid for separately)
21.1.2.2 Powdercoatedaluminium(minimumthickness of powder coating 50 micron) KG 200.00 634.45 126,890.00
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc.
61 21.3 with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the -
directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) Sqm 40.00 1,176.80 47,072.00
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing
62 21.8 weather silicon sealant over backer rod of approved quality as per architectural drawings and -
direction of Engineer-in-charge complete.
21.8.1 Upto 5 mm depth and 5 mm width meter 100.00 96.75 9,675.00
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and
manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor
63 21.18 spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, Sqm 10.00 5,325.90 53,259.00
all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be
paid separately).
Total of sub-head (11.0) 343,076.00
12 Water Proofing -
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed
64 22.3 portions of W.C., kitchen and the like consisting of: -
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound
conforming to IS 2645 in recommended proportions including rounding off junction of vertical -
and horizontal surface.
(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water
proofing compound in recommended proportion including rounding off junction of vertical and -
horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. -
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100
mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Total of sub-head (12.0) 92,352.00
13 Stone Work -
Total of sub-head (13.0) -
Preparation and consolidation of sub-grade with power road roller of 8 to 12 tonne capacity after excavating earth to an
16.1 average of 22.5cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. Sqm 600.00 218.90 131340.00
and re-rolling the sub-grade and disposal of surplus earth lead upto 50 mtr.
Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the
maximum dry density
16.3 Supplying and stacking at site.
16.3.1 90 mm to 45 mm size stone aggregate Cum 40.00 2098.40 83936.00
16.3.3 53 mm to 22.4 mm size stone aggregate Cum 50.00 1842.30 92115.00
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand
16.4 picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying Cum 90.00 1046.95 94225.50
and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and
compacting to the required density .
joints. depth per
16.45 Providing and fixing in position pre-moulded joint filler in expansion per cm joints. 100000.00 5.30 530000.00
Providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic
material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser,
propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material,
16.62 labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as sqm 30.00 747.80 22434.00
per direction of Engineer-in-charge and accordance with applicable
specifications.
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block
making machinewith strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern
over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the
direction of Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the
required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or
without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening
65 16.69 wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured cum 7.00 10117.60 70823.20
for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
16.75 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete
shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming
with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be Cum 30.00 9823.80 294714.00
paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per
design mix is payable/ recoverable
Total of sub-head NON DSR (14.0) 365,537.20
15 NON DSR ITEM
Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc.
Providing and fixing ISI marked stainless steel tower bolt black finish, (Barrel type) with
necessary screws etc. complete :
Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete :
Providing and fixing Stainless steel hanging type floor door stopper with necessary screws,
NSR 4.1 Providing & fixing Chicken wire mesh on joints of RCC & Brick work before plastering complete in the direction of Engineer-in-charge. sqm 250.00 222.00 55,500.00
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer
70 NSR 5 (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door Each 15.00 920.86 13,812.90
width upto 700 mm) with necessary accessories and screws etc. complete.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain
flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension
Grade), calcium carbonate and natural fibers (wood powder/ rice .husk/wheat husk) and non
toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650
kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive
strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of
Class A category with property of being termite/borer proof, water/moisture proof and fire
retardant and fixing with stainless steel butt hinges of required size with necessary full body
threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note:
stainless steel butt hinges and necessaryS.S screws shall be paid separately)
28 mm thick WPC (Wood polymer composite) solid plain flush door shutter
Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid
door/window/ceosetory windows and other frames/chowkhat comprising of virgin polymer of K
value 58-60 (Suspension Grade), calcium carbonate and natural fibers (woodpowder/ rice
.husk/wheat husk) and non toxic additives (maximum toxicity indexof 12 for 100 gms) fabricated
with miter joints after applying PVC solvent cement and screwed with full body threaded star
72 NSR 7 headed S.S. screws having minimum density of 750 kg/m3 and screw withdrawal strength of -
2200 N (Face) & 900 N (Edge), minimum compressive strength 58 N/mm2, modulus of elasticity
900 N/ mm2 and resistance to spread of flame of Class A category with property of being
termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S. hold
fast/lugs/S.S.dash fasteners of required dia and length complete as per direction of Engineer-in-
Charge. (M.S. hold fast/lugs or S.S. dash fasteners shall be paid separately)
(i) Single rebate (100 mm X50 mm) Meter 60.00 745.52 44,731.44
Providing and fixing 50 micron thick reflective one way type heat/light control film to
73 NSR 10 window/door glazing with complete accessories as per direction of Engineer-in- charge of Sqm 5.00 525.07 2,625.35
approved brand and make.
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of
internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked
74 NSR 11 for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of each 45.00 173.96 7,828.00
3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 16mm dia
M.S. bar bent to shape as per standard drawing.
SS Tactile Strip with Stem Each 202.00 200.60 40,521.44
Providing and fixing 12 mm thick toughened glass including all connectors and fixing
76 NSR 14 accessories all complete for partitions, cubicals etc. (excluding frame work) As per direction of Sqm 306.00 3,037.32 929,419.92
Engineer-in-Charge.
77 NSR 15 Cuddpah stone Sqm 2.00 1,511.76 3,023.51
Providing and fixing of roller blinds / vertical blinds of washable fabric duly fixed with powder
78 NSR 16 coated aluminum channel and clamps having nylon rope for manual operation of approved Sqm 306.00 1,311.57 401,340.42
colour and company as per director by Engineer-In-Charge.
Providing and fixing of Wallpaper of approved design, colour, pattern, as per direction of
Engineer-In-Charge including all material, labour, fixing and installation.
A Standard pattern and design wallpaper Sqm 2.00 849.07 1,698.14
B 3D pattern and design wallpaper Sqm 2.00 1,035.45 2,070.90
c Customize design wallpaper Sqm 1.00 1,580.79 1,580.79
80 NSR 18 Providing of Rotomoulded circular planters of different sizes.
A Upper dia 40cm and height 31cm Each 5.00 931.91 4,659.53
B Upper dia 50cm and height 37cm Each 2.00 1,583.55 3,167.10
C Upper dia 60cm and height 47cm Each 2.00 2,298.70 4,597.40
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Providing and fixing false ceiling atall height including providing andfixing of frame work made of
special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120
gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x
1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mmcentre to centre, one flange fixed
tothe ceiling with dash fastener 12.5 mmdia x 50mm long with 6mm dia bolts,other flange of
cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of
required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm
running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5mm thick
bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm
centre to centre, shall be fixed in adirection perpendicular to G.I. intermediate channel with
connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including
fixing perimeter channels
0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling
fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall
screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter
channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing
and finishing to a flush finish of tapered and square edges of the board with recommended
jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto
12.5mm thick moisture resistant gypsum plasterboards Moistbloc as per BS EN 520 confirming
to water absorption class H1 with total water absorption < 5%, Green Pro certified by Sqm 76.00 1,270.15 96,531.55
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing
treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs,
podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc.,
prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for
vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal
surfaces and applying the same from negative (internal) side with the help of synthetic fiber
brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by
reducing permeability of concrete by more than 90% compared with control concrete as
per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry
shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be
carried out all complete as per specification and the direction of the engineer-in-charge. The
product performance shall carry guarantee for 10 years against any leakage.
22.23.2 For horizontal surface one coat @1.10 kg per sqm. sqm 200.00 362.80 72,560.00
22.23.1 For vertical surface two coats @ 0.70 kg per sqm per coat sqm 50.00 472.90 23,645.00
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Providing and laying Granite stone flooring in required design and patterns in linear as well as
curvilinear portions of the building all complete as per the architectural drawings with 18 mm
82 NSR 20 thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse
sand) laid and jointed with cement slurry admixed with pigment of matching shade including
rubbing, curing and polishing and as directed by the
Engineer-in-Charge Granite stone slab Dark Black. Dark Red, White or equivalent,
Leather Finish Granite Sqm 212.25 3,878.11 823,127.87
Supplying & installing waterproofing treatment by using 1.2 mm thick HDPE membrane before
casting of the base RCCslab. The pre-applied membrane gets bonded to the underneath of the
poured concrete used as base slab. The membrane shall consist of a thick HDPE film, a highly
aggressive pressure sensitive adhesive and weather resisting coating which bonds integrally to
poured concrete of base slab. The membrane shall conforms to basement waterproofing
83 NSR 28 protection to grades 2, 3 & 4 as defined in BS 8102:2009. The waterproofing membrane shall 400.00 1,738.18 695,270.16
have following minimum properties:
a)Resist hydrostatic pressure of up to 70 m head of water as per ASTM D5385;
b)Puncture Resistance of 950 N (as per ASTM E154)
c)Elongation of >400 % (as per ASTM D412)
d)Peel Strength of concrete: >1500 N/m (as per ASTM D903)
Providing and applying 2.0 mm thick twin colour flexible PVC waterproofingmembrane.
Flexibility under lowtemperatures as per EN 495-5 should be < - 20degC. On all horizontal
surfaces Geotextile300 Gsm to be laid over PCC, than laying PVC membrane over Geotextile
and to be sealed with hot air welding method at all joints and over PVC membrane provide 300
Gsm Geotextile Then protection screed of suitable thickness. On all vertical surfaces Geotextile
300 Gsm to be laid along with Vertical wall, than laying PVC membrane over Geotextile and to
be sealed with hot air welding method at all joints and over PVC membrane providing protection
layer of Drain Board HDPE Dimple sheet before backfilling of soil.
Total of sub-head NON DSR (15.0) 3,464,115.69
16 Sanitary Installation (As per D.S.R.)
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets
85 17.10 and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting - - -
and making good the walls wherever required.
17.10.1 Kitchen sink with drain board. - - -
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P.
86 17.7 brass waste of standard pattern, including painting of fittings and brackets, cutting and making - -
good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar
Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P.
87 17.3 flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials - -
of standard make and mosquito proof coupling of approved municipal design complete,
including painting of fittings and brackets, cutting and making good the walls and floors
wherever required :
17.3.1 W.C. pan with ISI marked white solid plastic seat and lid Each 2.00 8,006.60 16,013.20
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast
Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with
88 17.1 manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures - -
complete, including cutting and making good the walls and floors wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580x440
mm with integral type foot rests
Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 metre long with S.S.
89 17.16A triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in-charge Each 2.00 349.15 698.30
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with
white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe,
90 17.5 spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap - -
with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting
and making good the walls and floors wherever required :
Single half stall urinal with 5 litre P.V.C. automatic flushing
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum
91 17.72 distance of 37 mm from wall face with concealed fittings arrangement of approved quality and Each 15.00 231.95 3,479.25
colour weighing not less than 88 gms
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP
brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm,
weighing not less than 190 gms.
Providing and fixing C.P. brass bib cock of approved quality conforming
Providing and fixing C.P. brass long nose bib cock of approved quality
conforming to IS standards and weighing not less than 810 gms.
18.50.1 15mm nominal bore Each 5.00 820.70 4,103.50
95 18.54 Providing and fixing PTMT bib cock of approved quality and colour. - - -
18.54.1 15mm nominal bore, 86 mm long, weighing not less than 88 gms Each - 125.60 -
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make
conforming to IS:8931.
97 18.55 Providing and fixing PTMT stop cock of approved quality and colour. - -
18.55.1 15 mm nominal bore, 86 mm long, weighing not less than 88 gms Each - 118.50 -
Providing and fixing C.P. brass angle valve for basin mixer and points of approved quality
conforming to IS:8931
18.53.1 15 mm nominal bore (For Shower) Each 6.00 574.30 3,445.80
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size
99 17.32 with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : - -
17.32.2 Rectangular shape 453x357 mm Each 6.00 1,361.80 8,170.80
17.32.4 Rectangular shape 1500x450 mm Each 4.00 2,093.00 8,372.00
100 17.28 Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete - - -
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
17.28.2 Flexible Pipe - - -
101 17.34 Providing and fixing toilet paper holder : - - -
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron
102 17.37 (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 - -
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of
cutting holes and making good the walls etc. :
103 17.39 Providing and fixing plain bend of required degree. - -
17.39.1.2 Sand cast iron S&S as per IS : 3989 Each 6.00 570.05 3,420.30
17.39.2.1 Sand cast iron S&S as per IS : 3989 Each 4.00 390.50 1,562.00
104 17.40 Providing and fixing heel rest sanitary bend - -
17.40.1.2 Sand cast iron S&S as per IS : 3989 Each 15.00 548.70 8,230.50
17.40.2.2 Sand cast iron S&S as per IS : 3989 Each 5.00 504.30 2,521.50
Providing and fixing single equal plain junction of required degree with access door, insertion
rubber washer 3 mm thick, bolts and nuts complete.
17.43.1.2 Sand cast iron S&S as per IS - 3989 Each 6.00 925.70 5,554.20
17.43.2.2 Sand cast iron S&S as per IS - 3989 Each 4.00 665.05 2,660.20
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
106 17.44 Providing and fixing single equal plain junction of required degree : - -
17.44.1.2 Sand cast iron S&S as per IS - 3989 Each 6.00 811.90 4,871.40
17.44.2.2 Sand cast iron S&S as per IS - 3989 Each 4.00 561.20 2,244.80
Providing and fixing single unequal junction of required degree with access door, insertion
rubber washer 3 mm thick, bolts and nuts complete :
17.47.1.2 Sand cast iron S&S as per IS - 3989 Each 6.00 1,146.20 6,877.20
108 17.56 Providing and fixing terminal guard : - -
17.56.1.2 Sand cast iron S&S as per IS - 3989 Each 6.00 506.00 3,036.00
17.56.2.2 Sand cast iron S&S as per IS - 3989 Each 2.00 404.75 809.50
109 17.57 Providing and fixing collar : - -
17.57.1.2 Sand cast iron S&S as per IS - 3989 Each 6.00 513.15 3,078.90
17.57.2.2 Sand cast iron S&S as per IS - 3989 Each 6.00 362.05 2,172.30
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or
110 17.60 without vent arm complete, including cost of cutting and making good the walls and floors : - -
17.60.1 100 mm inlet and 100 mm outlet - -
17.60.1.1 Sand cast iron S&S as per IS: 3989 Each 10.00 1,996.50 19,965.00
17.60.2 100 mm inlet and 75 mm outlet - -
17.60.2.1 Sand cast iron S&S as per IS : 3989 Each 5.00 1,975.15 9,875.75
111 18.21 Providing and fixing uplasticised PVC connection pipe with brass unions - - -
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints
but excluding the cost of pig lead :
18.28.1 100 mm diameter pipe Each 4.00 496.40 1,985.60
18.28.2 125 mm diameter pipe Each 3.00 737.50 2,212.50
18.28.3 150 mm diameter pipe Each 2.00 744.85 1,489.70
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of
75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm
114 17.71 distance from wall of standard shape with bracket of the same materials with snap fittings of Each 15.00 168.35 2,525.25
approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms
Providing and fixing white vitreous china extended wall mounting water closet of size
116 NSR 21 780x370x690 mm of approved shape including providing and fixing white vitreous china cistern Each 10.00 12,563.46 125,634.60
with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including
seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china type Anti germ Fluoro-Polymer Coated Wash Basin with
C.I. Brackets, 15 mm C. P. wall mounted pressmatic pillar cock auto closing system (decol
technology), 15mm quarter turn angular stop cock,
117 NSR 22 32 mm C.P. brass made waste coupling length 130mm and 32 mm C.P. Brass Made Bottle Trap
size 200x300mm fittings and fixtures complete including Painting of fittings and cutting and
making good the wall and floors wherever
White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595X435X185 mm with
basin mounted pressmatic pillar cock auto closing system (decol technology). (Premium Each - 19,742.58 -
Providing and fixing Flash touch-free infrared hand
118 NSR 23 dryer with 1150W rated power & carbon brush motor Material: 304 Stainless Steel Finish: Each 6.00 13,118.46 78,710.77
Stainless Steel Finish (Premium Range)
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Providing and fixing Automatic Soap Dispensers,
119 NSR 24 Capacity : 0.8L, Material: Aluminium /ABS, Finish Each 15.00 5,429.90 81,448.50
: Chrome/Black (Premium Range)
Providing and fixing chrome plated brass battery based infrared sensor operated pillar cock,
having foam flow technology. 15 mm nominal bore.
KENT Bathroom Water Softener, Product Code-111064, Net Weight-10.50 kg, Net Quantity-1
N,Product Dimensions(mm)-380 (L) X 220 (W) X 890 (H)
Total of sub-head (16.0) 347,688.05
Total of sub-head (16.0) NSR 522,207.81
17 Internal Drainage Installations (As per D.S.R.)
122 18.58 Providing and fixing PTMT grating of approved quality and colour -
18.58.1 Circular type -
18.58.1.2 125 mm nominal dia with 25mm waste hole. Each 10.00 51.85 518.50
Total of sub-head (17.0) 894.50
18 Water Supply Installations (As per D.S.R.) -
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot
and cold water supply including all CPVC plain and brass threaded fittings including fixing the
123 18.7 pipe with clamps at 1.00 m spacing. this includes jointing of pipes and fittings with one step - -
CPVC solvent cement and testing of joints complete as per direction of engineer in charge.
Internal work -Exposed on Wall - -
18.7.2 20 mm nominal dia pipes Metre 255.00 335.00 85,425.00
18.7.3 25 mm nominal dia pipes Metre 85.00 401.55 34,131.75
18.7.4 32 mm nominal dia pipes Metre 5.00 518.75 2,593.75
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having the thermal stability for
hot and cold water supply including all CPVC plain and brass threaded fittings including fixing
124 18.8 the pipe with clamps at 1.00 m spacing. this includes jointing of pipes and fittings with one step - - -
CPVC solvent cement and the cost of cutting chases and making good the wall same including
testing of joints complete as per the direction of engineer incharge
Concealed work including cutting chases and making good the wall etc. - - -
18.8.1 15 mm nominal dia pipes Metre 170.00 497.80 84,626.00
18.8.2 20 mm nominal dia pipes Metre 90.00 537.60 48,384.00
18.8.3 25 mm nominal dia pipes Metre 70.00 627.25 43,907.50
18.8.4 32 mm nominal dia pipes Metre 40.00 739.30 29,572.00
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot
125 18.9 & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of - -
pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints
complete as per direction of Engineer in Charge.
External work - -
18.9.1 15 mm nominal dia pipes Metre 70.00 244.70 17,129.00
18.9.2 20 mm nominal dia pipes Metre 40.00 274.30 10,972.00
18.9.3 25 mm nominal dia pipes Metre 69.00 355.40 24,522.60
18.9.4 32 mm nominal dia pipes Metre 18.00 438.60 7,894.80
Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and
making good the walls etc. (internal work)
Internal work - Exposed on wall - - -
18.10.2 20 mm dia, nominal bore Metre 5.00 437.30 2,186.50
18.10.3 25 mm dia, nominal bore Metre - 551.70 -
18.10.4 32 mm dia, nominal bore Metre - 667.00 -
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, including making good the
127 18.11 walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting - -
chases and making good the wall :
18.11.1 15 mm dia nominal bore Metre 10.00 580.45 5,804.50
18.11.2 20 mm dia nominal bore Metre 20.00 635.20 12,704.00
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
External work - -
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
18.12.1 15 mm dia nominal bore Metre 5.00 322.15 1,610.75
18.12.2 20 mm dia nominal bore Metre 5.00 368.60 1,843.00
18.12.3 25 mm dia nominal bore Metre 2.00 467.75 935.50
18.12.4 32 mm dia nominal bore Metre 2.00 540.30 1,080.60
Painting with synPainting G.I. pipes and fittings with synthetic enamel white paintwith two coats
over a ready mixed priming coat, both of approvedquality for new work
18.38.2 20 mm dia, nominal bore Metre 3.00 23.25 69.75
18.38.3 25 mm dia, nominal bore Metre 1.00 30.25 30.25
18.38.4 32 mm dia, nominal bore Metre 1.00 36.35 36.35
130 18.17 Providing and fixing gun metal gate valve with CI wheel of approved quality (screwed ends) - - -
18.17.1 25mm dia, nominal bore Each 4.00 622.40 2,489.60
18.17.1A 20mm dia, nominal bore Each 4.00 539.95 2,159.80
18.17.2 32 mm dia, nominal bore Each 4.00 689.60 2,758.40
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic
floats complete :
18.18.1 25mm dia, nominal bore Each 5.00 406.85 2,034.25
18.18.2 20mm dia, nominal bore Each 5.00 462.50 2,312.50
18.18.3 32 mm dia, nominal bore Each 5.00 464.05 2,320.25
132 18.19 Providing and fixing gun metal non- return valve of approved quality (screwed end) - - -
Providing and fixing rectangular high density polyethylene water storage loft tank with cover,
133 18.48A conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The Per Lit 2,000.00 11.00 22,000.00
rate includes making necessary holes for inlet, outlet & over flow pipes. The base support
Including fittings & fixtures for tank shall be paid separately.
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing
134 18.77 the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : Each 6.00 452.00 2,712.00
4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it
Total of sub-head (18.0) (DSR) 460,541.75
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
19 EXTERNAL SEWERAGE SYSTEM - -
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement
19.1 mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : -
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone
135.00 19.2 aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard - -
19.2.2 150 mm diameter S.W. pipe metre 100.00 1179.85 117,985.00
19.2.4 250 mm diameter S.W. pipe metre 200.00 1590.55 318,110.00
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick
135.01 19.4 masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight - -
of cover to be not less than
4.50 kg and frame to be not less than 2.70 kg as per standard design:
19.4.1 100x100 mm size P type - -
19.4.1.2 With Sewer bricks conforming to IS : 4885 each 6.00 2685.20 16,111.20
19.4.2 150 x 100 mm size P type. - -
19.4.2.2 With sewer bricks conforming to IS : 4885 each 12.00 2711.70 32,540.40
Providingand laying non-pressureNP2 class(light duty) R.C.C.pipes with collars jointed with
135.02 19.6 stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing - -
of joints etc. complete
Constructingbrick masonry manhole in cement mortar 1:4 ( 1 cement
: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3
graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4
19.7 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm - -
thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat
cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as
per standard design :
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm
19.7.1 internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover - -
23 kg and weight of frame 15 kg) :
19.7.1.2 With Sewer bricks conforming to IS : 4885 each 6.00 12711.80 76,270.80
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm
19.7.2 internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 - -
kg and weight of frame 58 kg) :
19.7.2.2 With Sewer bricks conforming to IS : 4885 each 6.00 26244.70 157,468.20
19.8 Extra for depth for manholes - -
19.8.1.2 With Sewer bricks conforming to IS : 4885 metre 2.00 8654.25 17,308.50
19.8.2.2 With Sewer bricks conforming to IS : 4885 metre 2.00 10381.45 20,762.90
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at
top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with
cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement
19.11 foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal - -
size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all
complete as per standard design :
1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal
diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg.
19.11.1 fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm - -
nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm
thick cement plaster at the external surface shall be paid for separately) :
19.11.1.2 With Sewer bricks conforming IS : 4885 each 2.00 24446.70 48,893.40
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia
at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with
cement mortar 1:3 (1 cement
136.00 19.9 : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 - -
cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary
channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) finished with a floating coat of neat cement, all complete as per standard design
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm
internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than
19.9.1 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 - -
mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12
mm thick cement plaster at the external surface shall be paid for separately) :
19.9.1.2 With Sewer bricks conforming to IS : 4885 each 2.00 12600.40 25,200.80
Extra depth for circular type manhole 0.91m internal dia (at bottom)
beyond 0.91 m to 1.67 m
19.10.2 With Sewer bricks conforming IS : 4885 metre 1.00 7448.45 7,448.45
Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m :
19.12.2 With Sewer bricks conforming IS : 4885 metre 1.00 9674.40 9,674.40
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at
top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with
cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement,
136.03 19.13 foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal - -
size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all
complete as per standard design :
2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal
diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg.
19.13.1 fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm - -
nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm
thick cement plaster at the external surface shall be paid for separately) :
19.13.1.2 With Sewer bricks conforming IS : 4885 each 2.00 52266.80 104,533.60
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m :
19.14.2 With Sewer bricks conforming IS : 4885 metre 1.00 22288.10 22,288.10
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks
136.05 19.15 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard - -
19.15.2 With 20 mm diameter round bar each 6.00 496.50 2,979.00
Making connection of drain or sewer line with existing manhole including breaking into and
making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4
136.06 19.21 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement - -
mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making
necessary channels for the drain etc. complete
19.21.1 For pipes 100 to 250 mm diameter each 4.00 810.45 3,241.80
Raising manhole cover and frame slab to required level including dismantling existing slab and
making good the damage as required (Raising depth of manhole to be paid separately) :
19.26.1 Rectangular manhole 90x80 cm with rectangular cover 600 x 450 mm of grade LD - 2.5 each 4.00 2625.50 10,502.00
19.26.2 Rectangular manhole 120x90 cm with circular cover 500 mm dia of grade MD - 10 each 4.00 4168.05 16,672.20
19.26.4 Circular manhole 140 cm dia with circular cover 600 mm dia of grade EHD - 35 each 2.00 320.15 640.30
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4
136.08 19.27 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame - -
complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar
137.00 19.28 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard - -
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
19.29Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement
137.01 19.29 mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating - -
with frame and vertical grating complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Constructing soak pit 1.20x1.20x1.20 m filled with brick bats including
S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Excavating trenches by mechinical / manual means of required width for pipes, cables, etc
including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth,
138.00 2.10 including getting out the excavated soil, and then returning the soil as required, in layers not - -
exceeding 20 cm in depth, including consolidating each deposited layer by ramming,
watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m
2.10.1 All kinds of soil - -
2.10.1.1 Pipes, cables etc., not exceeding 80 mm dia. metre 50.00 215.60 10,780.00
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. metre 150.00 352.15 52,822.50
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS
: 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23
mmx25 mm and over all minimum length 263 mm and width as 165 mm withminimum 112 mm
space between protruded legs having 2 mm tread on top surface by ribbing or chequering
besides necessary and adequate anchoring projections on tail length on 138 mm as per
standard drawing and suitable to with stand the bend test and chemical resistancetest as per
specifications and having manufacture’s permanent identification mark to be visible even after
138.01 19.16 fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 Each 34.00 553.70 18,825.80
coarse sand : 6 graded stone
aggregate 20 mm nominal size) complete as per design.
Providing and fixing in position pre-cast R.C.C. manhole cover and frame
of required shape and approved quality
Rectangular shape 600x450 mm internal
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick
138.03 19.32 honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 - -
m long complete as per standard design.
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Total of sub-head (19.0) (DSR) 1,363,133.25
20 External Storm Water Drainage System -
Supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge
139.00 23.5 pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in- cum 1.80 1509.80 2,717.64
Supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over
139.01 23.6 the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per cum 0.90 1538.25 1,384.43
direction of Engineer-in-charge.
Supplying, filling, spreading & levelling coarse sand of size range 1.5mm to 2mm, in recharge
139.02 23.7 pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of cum 0.90 1538.25 1,384.43
Engineer-in-charge.
Total of sub-head (20.0) (DSR) 5,486.49
21 Bore Well Installations (As per D.S.R)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed
in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting
140.00 23.1 strata chart/ bore log, including hire & running charges of all equipments, tools, plants &
machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90
metre depth below ground level.
23.1.1 All types of soil
23.1.2 Rocky strata including Boulders
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed
in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting
140.01 23.2 strata chart/ bore log, including hire & running charges of all equipments, tools, plants &
machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90
metre & upto 150 metre depth below ground level.
23.2.1 All types of soil
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
23.2.2 Rocky strata including Boulders -
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC
140.02 23.3 medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire Meter
and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of
Engineer -in-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC
140.03 23.4 medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour
charges, fittings & accessories etc. all complete, for all depths, as per direction of
Engineer-in-charge.
23.4.3 200 mm nominal size dia metre 150.00 1255.7 188,355.00
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel
140.04 23.8 fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per cum - 2024.5 -
direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish
maximum rate of usable water yield without sand content (beyond permissible limit), with
required capacity air compressor, running the compressor for required time till well is fully
140.05 23.12 developed, measuring yield of well by "V" notch method or any other approved method, hour 5.00 1085.05 5,425.25
measuring static level & draw down etc. by step draw down method, collecting water samples &
getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire &
labour charges of air compressor, tools & accessories etc., all as per requirement and direction
of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore
well housing/ casing pipe, removable as per requirement, all complete for borewell of:
23.13.3 200 mm nominal size dia Each 1.00 321.15 321.15
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as
per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of
tubewell as per IS:2800 (part I).
S. No. Unit Quantity Rate (In Rs) Amount (In Rs)
Total of sub-head (21.0) (DSR) 589,056.15
Proposed Construction of Jaipur Centre of Excellence Building , ICMAI ,Jaipur Rajasthan
S.N. DESCRIPITION DSR MPPWD SOR AMOUNT
1 INTERNAL ELECTRICAL 2824640.00 2601322.00 5425962.00
5 EXTERNAL FEEDER LINE 60592.00 687832.00 748424.00
6 EXTERNAL SUB STASTION 647591.00 237130.60 884721.60
7 EXTERNAL LT DISTRIBUTION LINE 376592.00 364269.60 740861.60
Name of Project:- Proposed Construction of Jaipur Centre of Excellence, ICMAI Rajasthan
S.No. of Project Sub Head :- 1
Name of Project Sub Head :- ICMAI BUILDING
S.No. of Component :- D
Name of Component :- INTERNAL ELECTRIFICATION
Abstract Of Cost
S.No. DSR Item DSR sub item Item Name Description of Item Unit Quantity Rate Amount
NO. No, if any
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5
sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in
surface/ recessed medium class PVC conduit, with modular switch,
1 1.10 modular plate, suitable GI box and earthing the point with 1.5 sq.mm
FRLS/HFFR PVC insulated copper conductor single core cable etc. as
2 Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR 21636.00
PVC insulated copper conductor single core cable in surface /
recessed medium class PVC conduit, 2way modular switch, modular
1.11 plate, suitable GI box and earthing the point with 1.5 sq.mm Each 12 1803.00
FRLS/HFFR PVC insulated copper conductor single core cable
Wiring for circuit/ submain wiring along with earth wire with the following 0.00
sizes of FRLS/HFFR PVC insulated copper conductor, single core
3 1.14 cable in surface/ recessed medium class PVC conduit as required.
1.14.8 4 X 4 sq. mm + 2 X 4 sq. mm earth wire Meter 390 587.00 228930.00
4 1.17 Supplying and drawing following sizes of FRLS/HFFR PVC 0.00
insulated copper conductor, single core cable in the existing surface/
recessed steel/ PVC conduit as required.
1.5 sq. mm. wire 0.00
2.5 sq mm wire 0.00
4 sq mm wire 0.00
6.00 sq. mm. wire 0.00
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid 0.00
copper conductor PE insulated, shielded with fine tinned copper braid
5 1.19 and protected with PVC sheath in the existing surface/ recessed mtr 0 54.00
steel/ PVC conduit as
Supplying and fixing of following sizes of medium class PVC 0.00
conduit along with accessories in surface/recessincluding
6 1.21 cutting the wall and making good the same in case of recessed conduit
7 1.25 Supplying and fixing two module stepped type electronic fan regulator on Each 45 402.00 18090.00
the existing modular plate switch box including connections but excluding
modular plate etc. as required.
8 1.27 Supplying and fixing following size/ modules, GI box along with modular 0.00
base & cover plate for modular
switches in recess etc. as required.
Supplying and fixing suitable size GI box with modular plate and 45780.00
cover in front on surface or in recess, including providing and fixing 3 pin
9 1.31 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as Each 84 545.00
10 1.45 Installation, Testing and Commissioning of ceiling fan, Meter 45 332.00 14940.00
including wiring the down rods of standard length
(upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC
insulated, copper conductor, single core cable,
including providing and fixing phenolic laminated
sheet cover on the fan box etc. as required.
11 Wiring for group controlled (looped) light point/fan point/exhaust 0.00
fan point/ call bell point ( without independent switch etc.)
with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor
1.55 single core cable in surface/ recessed PVC conduit, and earthing
the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper
conductor single core cable etc. as required.
2.2 Providing and fixing following rating and breaking capacity and pole MCCB 0.00
with thermomagnetic release and terminal spreaders in existing cubicle
panel board including drilling holes in cubicle panel, making connections,
Ics=100% Icu and Operational Voltage 690V etc. as required.
12 2.3 Supplying and fixing following way, single pole and neutral, 0.00
sheet steel, MCB distribution board, 240 V, onsurface/ recess,
complete with tinned copper bus bar, neutral bus bar, earth bar,
din bar, interconnections, powder painted including earthing etc. as
without MCB/RCCB/Isolator)
2.3.1 6 way , Double door Each 2 2390.00 4780.00
2.3.2 8 way , Double door Each 3 2773.00 8319.00
2.3.3 12 way , Double door Each 7 2871.00 20097.00
13 Supplying and fixing following way, horizontal type three pole and 0.00
neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess,
complete with tinned copper bus bar, neutral bus bar, earth bar, din
2.4 bar,interconnections, powder painted including earthing etc. as
required. (But without MCB/RCCB/Isolator).
14 Supplying and fixing of following ways surface/ recess mounting, 0.00
vertical type, 415 V, TPN MCB distribution board of sheet steel,
dust protected, duly powder painted, inclusive of 200 A tinned copper bus
2.5 bar, common neutral link, earth bar, din bar for mounting MCBs (but
without MCBs and incomer ) as required . (Note : Vertical type MCB
TPDB is normally used where 3 phase outlets are
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, 0.00
miniature circuit breaker suitable for inductive load of following poles
15 2.10 in the existing MCB DB complete with connections, testing and
commissioning etc. as
2.10.5 Triple pole and neutral Each 9 1301.00 11709.00
Supplying and fixing following rating, four pole, (three phase and 0.00
neutral), 415 volts, residual current circuit breaker (RCCB), having a
16 2.15 sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and
commissioning etc. as required.
17 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 32508.00
pole and earth, metal enclosed plug top along with 20 A "C" curve, SP,
MCB, in sheet steel enclosure, on surface or in recess, with chained metal
2.18 cover for the socket out let and complete with connections, testing and Each 18 1806.00
commissioning etc. as
Supplying and fixing Cable End Box (Loose Wire Box) suitable for 0.00
following single pole and neutral, sheet steel, MCB distribution board,
18 2.23 240 Volts, on surface/ recess, complete with testing and commissioning
etc. as required.
2.23.1 For 6 way, Double door SPN MCBDB Each 2 834.00 1668.00
2.23.2 For 8 way, Double door SPN MCBDB Each 3 918.00 2754.00
2.23.3 For 10 way, Double door SPN MCBDB Each 7 895.00 6265.00
19 Supplying and fixing Cable End Box (Loose Wire Box) suitable for 0.00
following triple pole and neutral, sheet steel, MCB distribution board,
2.24 415 Volts, on surface/ recess, complete with testing and commissioning
etc.as required.
2.24.1 For 4 way, Double door TPN MCBDB Each 3 1177.00 3531.00
2.24.2 For 6 way, Double door TPN MCBDB Each 3 1223.00 3669.00
Supplying and fixing Cable End Box (Loose Wire Box) suitable for 3813.00
triple pole and neutral, sheet steel, Vertical MCB distribution board,
20 2.25 415 Volts, on surface/ recess, complete with testing and commissioning Each 3 1271.00
etc. as required.
Hot Dipped Galvanized Iron Cable Tray 0.00
Supplying and installing following size of perforated Hot Dipped
Galvanised Iron cable tray (Galvanisation thickness not less
than 50 microns) with perforation not more than 17.5%, in
21 4.6 convenient sections, joinedwith connectors, suspended from the ceiling
with two numbers GI Suspenders i/c base of suitable size GI angle, GI
bolts & nuts, fastner etc as required.
4.6.1 100 mm width X 50 mm depth X 1.6 mm thickness Meter 10 754.00 7540.00
4.6.2 150 mm width X 50 mm depth X 1.6 mm thickness Meter 10 803.00 8030.00
4.6.4 300 mm width X 50 mm depth X 1.6 mm thickness Meter 5 1062.00 5310.00
4.6.5 375 mm width X 50 mm depth X 2.0 mm thickness Meter 5 1322.00 6610.00
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including 33404.00
accessories, and providing masonry enclosure with cover plate
22 5.4 having locking arrangement and watering pipe of 2.7 Meter long etc. Set 4 8351.00
coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick 60016.00
including accessories, and providing masonry enclosure with cover
23 5.6 plate having locking arrangement and watering pipe of 2.7 Meter long Set 4 15004.00
with charcoal/ coke and salt as required.
24 5.7 Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground Metre 104 62.00 6448.00
level for conductor earth electrode, including connection/ termination with
GI thimble etc. as required.
38 5.10 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe Metre 60 1638.00 98280.00
from earth electrode including connection with brass nut, bolt, spring,
washer excavation and re-
filling etc. as required.
25 5.11 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia Metre 60 755.00 45300.00
G.I. pipe from earth electrode including connection with
G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
LED LIGHTING 0.00
26 LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) 0.00
Supplying, installation, Testing & Commissioning of Panel light 2x2 ft.,
of following body material and construction as per IS : 10322 with
driver as per the requirement with Driver efficiency >85%,
Operatingoltage AC 140-270 Volt, frequency 50/60 hz, Operating
temp range -5 0C to 40 0C, internal surge protection of 2.5 KV
with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI
>80,UGR(Unified Glare Rating) < 19, Flicker free, (flicker should be
below 5 %), life time (LED, Driver &electrical circuitry), of minimum
50000 Burning Hours with, 70% of initial Lumen maintained till life
ends as per LM80 extrapolation IES TM-21-11 report, CCT
ANSIBin), SDCM(Standard Deviation Colour Matching)
8.6 <3, Maximum power consumption should not morethan the specified
rating and Fixture shall be of relevant BIS standard. Manufactures
Word Mark/NameEngraved/ Embossing/ Screen printing on
housing. complete in all respect i/c external connections with
1.5 sq mmFRLS/HFFR, PVC insulated copper conductor single
core cable and earthing etc. as required withMinimum 5 year OEM
warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79
& LM80 Testreport and all testing required for LED fixtures as
per BIS shall be submitted. Shape size and CCTshallbe as
approved by Engineer-in-Charge as per requirement. (Thermal
management: heat sink of aluminium housing such that
Powder Coated CRCA Sheet Body (Thickness > 0.00
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). 0.00
Supplying, Installation, Testing & Commissioning of LED surface mounted
Batten light of following body material and construction as per IS : 10322
with driver (Replaceable) as per the requirement with Driver efficiency
>85%, Operating voltage AC 140
270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C,
internal surge protection of 2.5 KV
with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI
>80, Flicker free, (flicker should be below 5 %), life time (LED, Driver &
electrical circuitry), of minimum 50000 Burning Hours
with 70% of initial Lumen maintained till life ends, CCT 3000°K /
(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3,
27 8.9 Maximum power consumption
should not more than the specified rating and Fixture shall be of relevant
Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing
on housing. complete
in all respect i/c external connections with 1.5 sq mm FRLS/HFFR,
PVC insulated copper conductor single core cable and earthing etc. as
required with Minimum 5 year OEM warranty. System lumen efficacy
≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing
required for LED fixtures as per BIS shall be submitted. Shape size
and CCT shall be as approved by Engineer-in
Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 0.00
Brush Less Direct Current (BLDC) Fan without Remote Supply, 0.00
Installation, Testing and Commissioning of ceiling fan with Brush Less
Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(
Aluminium rise=75 0C (max.), insulation resistance more than 2 mega
ohm, suitable for
28 9.2 230 V, 50 Hz, single phase AC supply,Ceiling Fan compliant to
IS 374:2019 fan i/c external connections with 1.5 sq.mm
FRLS/HFFR, PVCinsulated copper conductor single core cable
and earthing etc. as required.
9.2.3 1200mm, service value ≥ 6.0 CM/Min/Watt, air Each 45 2695.00 121275.00
delivery 210 CM/Min (Minimum)
Laying of one number PVC insulated and PVC sheathed / XLPE power 0.00
cable of 1.1 KV grade of following size direct in ground including
29 10.1 excavation, sand cushioning, protective covering and refilling the
trench etc as required.
10.1.2 Above 35 sq. mm and upto 95 sq. mm Metre 60 475.00 28500.00
10.1.4 Above 185 sq. mm and upto 400 sq. mm Metre 55 564.00 31020.00
30 10.5 Laying of one number PVC insulated and PVC sheathed / XLPE power 0.00
cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL
pipe as required.
10.5.2 Above 35 sq. mm and upto 95 sq. mm Metre 60 72.00 4320.00
10.5.4 Above 185 sq. mm and upto 400 sq. mm Metre 55 170.00 9350.00
Supplying and fixing of following size Wall Mount Rack having Fixed 0.00
Structure with 0.8mm CRCA Sheet, completely knocked-down condition
(CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2
cable entry/exit provision at Top and bottom with rubber protection, Front
5mm Toughened Glass with lock, wall mounting kit, Powder coated Color-
RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power
distribution units, 3 numbers closed cable organizer, Hardware mounting
screws packet of 20 x 1 number, etc. complete as required.
MPPWD SOR 0.00
32 Point wiring Point wiring (excluding metallic switch box & sheet but including 0.00
concealed rigid switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm.
P.V.C. conduit PVC insulated cable FR-LSH with copper multi strand conductor ISI
marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable
1.5sq. mm. PVC insulated FR-LSH copper earth continuity conductor of
green colour inside conduit, screwless connector for joints etc. as
required as per specification
4.1.3 Socket 6A sep. 3 Pin 6 Amp socket outlet on Separate Board 0.00
4.1.3.2 Medium b) Medium point Each 19 1188.00 22572.00
4.1.3.3 Long c) Long point Each 44 1818.00 79992.00
Power point Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 0.00
wiring concealed Amp. socket outlet point with 4sq. mm. PVC insulated cable
rigid FR-LSH with copper multi strand conductor ISI marked in
P.V.C. conduit concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc.
F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and
4sq. mm. PVC insulated FR-LSH copper earth continuity conductor
of green colour inside conduit, screwless connector for joints as per
specification for :-
9.1.1 Power point On separate board 0.00
9.1.1.1 Short Short point Each 2 1182.00 2364.00
9.1.1.3 Long Long point Each 2 3134.40 6269.00
9.1.1.4 Ex. long-I Extra long-I Each 3 4377.60 13133.00
9.1.1.5 Ex. long-II Extra long-II Each 4 5725.20 22901.00
9.1.1.6 Ex. long-III Extra long-III Each 5 7183.20 35916.00
34 9.2 Same board Same board switch & socket 16 Amp./S.S. combined Each 12 524.40 6293.00
Sub mains in Wiring for sub-mains with PVC insulated cable FR-LSH with copper 0.00
recessed/conce multi strand conductor ISI marked in recessed/concealed rigid
aled rigid PVC PVC conduit (HMS) ISI marked of suitable size (conduit included)
35 23.1 conduit (HMS) including 2mm thick accessories, connection etc, as required
as per specification. (Refer General Notes for Classification of
Conduit Wiring Point No.10)
23.1.4 4 Wire 4 WIRE SUB-MAIN 0.00
MCCB 3Ph, 3 Supply of ISI marked and approved make of moulded case circuit 0.00
Pole, 50Hz, breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC
36 27.1 415V supply with respective interrupting capacity (KA) at 415 Volts cited
against their range
standard conforming to IS – 8828
27.1.1 MCCB upto MCCB current rating – upto 63 Amp, 10kA, 3P 415V Each 3 3265.20 9796.00
37 28.4 Fixing of Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as 0.00
MCB/MCCB/Is per accepted practice, including mounting on busbar and cable
olator, (labour connection etc. complete (labour only)
28.4.1 MCB/Isolator MCB / Isolator SP/DP Each 108 26.40 2851.00
MCB /MCCB MCB /MCCB Isolator TP /TPN/FP 706.00
28.4.2 Isolator TP Each 21 33.60
Labour charges Labour charges for fixing sheet steel enclosures, 0.00
MCB/MCCBDB flush mounting type, as per accepted
38 28.8 practice, duly embedded and end plate completely flushed
in wall, cable connection etc. complete :-
For item For item no :- 0.00
39 29.6 Multi core Supply and fixing of multi core round FR-LSH PVC insulated 0.00
flexible cables copper (flexible) conductor & PVC sheathed cables 1100Volts as per
IS:694-1990 of approved make
40 29.6.2 Three core (24/0.2 mm) Three core 0.75 sq.mm. Meter 87 30.00 2610.00
LT panel Supply, fixing, testing & commissioning wall/floor mounted LT panel 64314.00
primer coated with powder coated paint & provided with required
gasket for dust/vermin proof with degree of protection IP42 suitable for
415Volt 3 phase, 50 Hz, 4 wire system fabricated out of CRCA sheet
upto 2 mm thick (1.6 mm for doors) duly compartmentalized for
incomer, bus section, outgoings, cable alleys & CT, PT Ampere
Metre, Volt Metre, selector switches, frequency Metre, phase
indicating lamp, Energy Metre complete including cost of busbar
supports, detachable cable gland plates, 2 earthing terminals, internal
wiring & fixing of separately supplied MCBs, MCCBs, ACB, panel
mounted changeover switch/SFUs, etc. as required but excluding cost
of busbar strips, Ampere Metre, Volt Metre, selector switch as per
approved design & specification
42 29.28 LT panel Supply and fixing of LT panel accessories of approved make in 0.00
accessories existing LT panel including connections etc. as required as per
29.28.1 Digital Ampere Digital Ampere Metre with CTs with selector switch P.SET 1 2550.00 2550.00
29.28.2 Digital Volt Digital Volt Metre with selector switch & HRC fuse P.SET 1 2877.60 2878.00
29.28.3 Frequency Frequency Metre Each 1 1722.00 1722.00
29.28.6 Aluminium bus Aluminium bus bar strips with PVC sleeves Kg. 47.3 340.80 16120.00
29.28.7 LED lamp LED lamp indicator Each 3 306.00 918.00
Deluxe fresh air fan Supplying and fixing of deluxe fresh air fan with louvers (ventilating 0.00
fan) with self-closing louvers of decorative PVC blades mounting
43 30.5 square frame of approved make complete with all necessary material
Exhaust fan Supplying, erecting and testing of approved make exhaust fan heavy 0.00
heavy duty duty with mounting frame, blades AC 230-250 complete connection
44 30.6 and including, frame bolt/anchor hole fasteners etc. complete finished and
Fixing for Providing and fixing circular/hexagonal cast iron or M.S. sheet box Each 4860.00
ceiling fan for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of
clamp 1.5mm thick M.S. sheet with its top surface hacked for proper
bonding, top lid shall be screwed into the cast iron/M.S. sheet box
3.3mm dia. round headed screws, one lock at the corners. Clamp shall be
made of 12mm dia M.S. bar bent to shape as per standard drawing.
46 Elect. Sanitary Supply, Installation, Testing and Commissioning of Electrical 0.00
napkin incinerator Napkin Incinerator Wall mounted factory fabricated with CRCA
sheet steel of 1.2mm thickness duly powder coated suitable for 230V
32.17 50Hz AC Supply with auto cut-off feature having insulation of thermal
ceramic sheet with glass wool of 4-5mm thick with MCB protection &
aprox.2 meter flexible flue gas pipe with clamp.
32.17.2 50 Per Day Sanitary Napkin Incinerator( Capacity 50 per Day) Each 1 46399.20 46399.00
47 37.21 Lightning Lightning conductor 0.00
18mm dia Providing and fixing of lightning conductor finial made of 4736.00
18mm dia 500mm long bright nickel plated copper tube
plated copper tapered having single prong at top with bright nickel plated
37.21.1 tube brass base M10 for connection and intersection of flat Each 1 4736.40
or round conductor including holes, clamp complete as
48 37.25 Cu. tape 20x3 Providing and fixing copper tape 20mm X 3mm thick on parapet and Metre 150 680.40 102060.00
mm (for surface of wall of lightning conductor as required (for horizontal runs)
horizontal runs)
Cu. tape 20x3 Providing and fixing copper tape 20mm X 3mm thick on 42552.00
49 37.26 mm (for vertical parapet and surface of wall of lightning conductor as required (for Metre 60 709.20
runs) vertical runs)
PVC insulated cu. Supply and drawing PVC insulated copper cable (earth continuity 0.00
cable earth conductor) of green colour FR-LSH with copper multi strand conductor
50 37.39 continuity conductor ISI mark in existing conduit along with other wires as required as per
specification :
51 38.9 RJ-45 Supply, installation testing and commissioning RJ - 45 computer jack 0.00
computer jack cat 6 with shutter modular (1Module)
38.9.1 Cat 6 with RJ - 45 computer socket cat 6 with shutter modular (1Module) each 21 345.60 7258.00
shutter modular
RJ-45 Supply, installation testing and commissioning RJ - 45 computer jack 39686.00
52 38.10 computer jack cat 6 with shutter modular (2Module) each 48 826.80
53 4 Pair shielded Supplying and drawing 4 pair shielded twisted pair (STP), 197184.00
twisted pair 0.5 mm PVC insulated copper conductor un-armoured Cat 6 computer
38.12 (STP) cable FR-LSH in existing surface/concealed, steel/PVC. conduit/ casing- Metre 1580 124.80
n-capping as required.
54 38.15 Patch panel, RJ Supply, installation testing and commissioning of 19" modular each 3 14150.40 42451.00
45 patch - 1 U patch panel 24, RJ 45 cat-6 connector
3 Phase deep Supplying &installation of required capacity of three phase, 50 0.00
well submersible Hz,415V, deep well submersible pump steel body, as per
IS of approved make, suitable upto 6 " tube well with
control panel starter suitable for submersible pump with
55 39.2 dry run protection, single phase preventer, connections,
including clamp, bore cap etc. as required as per
specifications but excluding pipe and connection cable.
discharge LPM 60-270
Submersible Supplying and laying of submersible flat cable ISI marked 3 core copper 0.00
56 39.3 flat cable 3 wire of suitable size with proper clamping of
core cu. wire approved make.
39.3.2 4.0 sq.mm 4.0 Sq.mm multi strand Metre 150 246.00 36900.00
HDPE pipe Supplying and laying of approved make HDPE pipe as per IS:4984 and 0.00
IS:14333 with latest amendment for installation of
57 39.4 submersible pump with necessary connection, socket/couplings,
tees, etc. as required (PE-
63 & working pressure 6 kgf/sq cm)
58 39.5 Nylon rope 12 Supplying and laying of approved make nylon rope 12 mm Metre 150 91.20 13680.00
mm thick thick complete with binding for support of pump and motor.
59 39.10 3 Phase open Supplying &installation of approved make required capacity 3 0.00
well submersible phase, 50 Hz, 415V, open well submersible pump, with control panel
pump starter with dry run protection, single phase preventer, connections,
etc. as required as per specifications but excluding pipe and
39.10.2 5.0 HP head 5.0 HP head metre 12-28, discharge LPM 1200- Each 57268.80 57269.00
60 40.1 G.I. floor Supply, installation, testing and commissioning of G.I. floor raceway of 0.00
raceway mention below sizes 1/3 compartments
including all necessary civil works.
61 41.1 XLPE insulated Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 0.00
power cable, al. 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu.
conductor stranded /solid conductor
41.1.8 3½ core 3½ core armoured 0.00
41.1.10 4 core 4 core armoured 0.00
Boom Barrier 0.00
Electromechanical boom barrier with all accessories upto Each 1 120000.00 120000.00
62 6 metre length)
Door Frame metal Detector 0.00
20 zone or above door frame metal detector nominal size 760 mm (W) x Each 1 372000.00 372000.00
2050 mm (H) x 700 mm (D) loaded with
necessary software.
Motorized steel gate upto 6 m width Each 1 500000.40 500000.00
TOTAL DSR 2824640.00
TOTAL NON DSR 2601322.00
TOTAL DSR + NON-DSR 5425962.00
Name of Project:- Proposed Construction of Jaipur Centre of Excellence, ICMAI Rajasthan
S.No. of Project Sub Head :- 1
Name of Project Sub Head :- ICMAI BUILDING
S.No. of Component :- D
Name of Component :- CCTV
Abstract Of Cost
S.No. DSR DSR sub Item Name Description of Item Unit Quantity Rate Amount
Item NO. item No, if any
Supplying, installation, Testing and commissioning of following
capacity 8 port Layer 2 indoor Network Switch having features
and specifications etc. as mentioned here under: Minimum 8 X
RJ-45 Gigabit EthernetPorts and additional 2 X 1G SFP Ports
with non-blocking architecture by having Switching capacity
ofminimum 20Gbps and packet forwarding rate of 14Mpps or higher,
8K MAC table. Internal dual AC Powersupply with
operating temperature of -5 0C to +50 0C. Jumbo frame: 10KB or
higher, IGMPSnooping,IGMP snooping querier and support
forIGMP Snooping Fast Leave, Should create 250
ormoreMLD groups, MLD Snooping, Per VLAN MLDSnooping
C MLD Snooping Fast Leave, STP, RSTP,MSTP,Loopback
detection, Multicast filtering, VLANTagging, ǪOS: 8 Ǫue per
1 39.1 port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route
entries and minimum 50 IPv6 static route entries, 700 Acess
Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP
Spoofing, DHCP Snooping and server screening,
IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X
Authentication (Supports local/RADIUS database,Port-
based Access Control and EAP, OTP, TLS, TTLS, PEAP
Support) Cable Diagnostic feature, LLDP,LLDP-MED, SNTP/NTP,
RMON, SNMP v1,v2c, v3
and SNMP Traps. Certifications: UL, CE, FCC,
RoHS,MTCTE, OEM/Product must be on Trusted Telecom
Portal of Department of Telecommunication, Government of India
etc. complete as required.
8 port PoE Layer 2 Network Switch with PoE Support of 130W or
39.1.1 higher with each copper port supporting Each 2 35091.00 70182.00
Supplying, drawing, Testing and commissioning of Cat6A
UTP 4 pair, 23 AWG solid copper cable in existing conduit/
on surface, U/FTP, LSZH, Non Plenum, Horizontal (solid) Cable
suitable for high speed data networking application supporting
upto 10Gbps over a
100 meter channel. The 4 Unshielded Twisted Pairs (UTP)
cable with color coded insulation for easy indentification
should have FLAME PROPERTIES i.e. Flammability Test - IEC
60332-1, Smoke Density - IEC 61034, LSZH standards
compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an,
RoHS. Delay Skew
should be < 45NS. The outer Cable Diameter should be
7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL
etc. complete as required.
Supplying Installation Testing and Commissioning of 2 MP IP IR
3 40.1 Dome Camera having following
specifications, type of lens and features etc :-
1) Signal System: PAL/NTSC, Signal to Noise Ratio:>50 dB,
Camera should display Camera title, Date &Time in live & recorded
video2)Image Sensor: 1/2.8" or better progressive ScanCMOS
to get color image even at nightcondition(Minimum
Illumination:[email protected],AGC ON, 0 lux with IR or better)
True Day & NightHigh Performance Mechanical IR cut filter with
autoswitch, Integrated IR Source (Auto, Manual)- Inbuilt IRLED's
with effective distance upto 50 meter or betterand 30 meter
for colour viewin night,Imaging:1/3s to1/30000s electronic
shutter support, Auto Gain Control, White Balance- Auto, Back
Light Compensation,Multi zone Privacy Masking, HLC,
DigitalWatermarking.3) Compression (Minimum):-Video:-
H.265 or better,H.264H, H.264, Audio:-
G.711U/A,G.711Mu, G.726,AAC, G.7234) Wide
Dynamic Range:- WDR (120db or more)5) Digital Noise Reduction:-
DNR (3D) On/Off6) Video Streaming & Frame Rates :-
Triple streaming, configurable
×1080)@25/30 720P@25/30 fps).(Main fps,Sub stream:
streams2MP(1920minimum:7) Image Setting: Rotate Mode,
saturation, brightness,contrast, sharpness adjustable through
client softwareor web browser, Edge Analytics: Tripwire,
Intrusion,Motion Detection8)Cyber Security:
bitEncryption,Configurationencryption,trusted execution,
Digest,security logs, account lockout, syslog,
videoencryption, IP/MAC filtering, HTTPS, trusted
upgrade,trusted boot.9) Onboard Storage: Camera
Camera with 2.8/ 3.6mm fixed lens
4 40.2 2 MP IP IR Outdoor Bullet Camera
Supplying Installation Testing and Commissioning of 2MP
Fixed Lens IP IR Outdoor Bullet Camera having following
specifications and features etc :- 1) Signal System:
PAL/NTSC, Signal to Noise Ratio: >50 dB,Camera should
display Camera title, Date &Time inlive&recorded video 2)Image
Sensor: 1/2.8" or better progressive ScanCMOS to get color
image even at nightcondition(Minimum Illumination: 0.006
Lux@ F1.4,AGC ON, 0 lux with IR or better) True Day &
NightHigh Performance Mechanical IR cut
filterwithautoswitch,Integrated IR Source (Auto, Manual)-
InbuiltSmart IR LED's with effective distance upto 50 meteror
better and 30 meter for colour view in night,Imaging: 1/3s
to 1/30000s electronic shutter support,Auto Gain
Control , White Balance-Auto,BackLightCompensation,
Multi zone Privacy Masking, HLC,Digital Watermarking.3)
Compression (Minimum):-Video:- H.265 or better,H.264H,
H.264, Audio:- G.711U/A, G.711Mu, G.726,AAC, G.7234) Wide
Dynamic Range:- WDR (120db or more)5)
DigitalNoiseReduction:-D)On/Off6) Video Streaming & Frame
Rates :- Triple streaming, configurable(Main 1080)@25/30 fps
stream: Sub 2MP (1920 ×streams minimum:720P@25/30
fps).7) Image Setting: Rotate Mode, saturation,
brightness,contrast, sharpnessadjustable through client
softwareor web browser, Edge Analytics: Tripwire,
Intrusion,Motion Detection8)Cyber Security: AES
256-bit Encryption,Configuration encryption, trusted execution,
Camera with 2.8/ 3.6mm fixed lens
Supplying Installation Testing and Commissioning of following
Channel Network Video Recorder (NVR) with camera licenses
to record for all channels having specifications and features
etc as mentioned below : 1) Network Video Recorder
Embedded/ Installed OS (Linux) along with Camera
Licenses for number of channels of NVR to record per NVR and
to provide a live view, storage and simultaneously Multi-channel
playback of all IP, IR camera or more and must be ONVIF
with minimum support of 256Mbps incoming Bandwidth.2) NVR
should support H.265 or better, H.264, MJPEG, MPEG4 support
3) Must support 1 channel Input, 1 channel Output, RCA for
Two-way Talk 4) Intelligent auto power on when power resumes
after power outage.
5 40.10 5) Storage: It should support minimum 2 SATA Slots with 20TB
capacity/ Slot. 6) Connectivity Interface : 1 Nos. x 10/100/1000
Mbps Ethernet Ports, 1x RS485, 1x RS232 7) Backup Interface :
Its should have 2 Nosx USB port (1x USB3.0, 1xUSB2.0) 8) Video
Output Ports: 1x HDMI and 1 VGA 9) Alarm Ports: It should have 4/1
Ch In/ Out ports to connect various type of external sensors
and output devices like hooter/ Siren etc. 10) Email & SMS
Altert options: Option for SMS/ Email Alerts to minimum 5
designated mobile number for power failure, HDD failure,
vandalism, tempring, network disconnection and panic 11) Web &
Mobile Application: Web, Mobile app ( For iPhone, iPad, Android
Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS,
TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP,
19) The OEM must provide its own DDNS server hosted in India,
eliminating the need for a public IP address for remote monitoring
over the Internet. 20) Must support Resolution: 7680x4320
21) Must support
recording resolution upto 32MP 22) Must support
Continuous, Alarm, Motion, Instant, Panic Recording Mode
23) When alarm recording is enabled and an event occurs, you
can click the alarm icon on monitoring page to view the alert
details. The snapshot function is supported on monitoring and
playback page 24) The Network Video Recorder (NVR) shall be
configured to send email whenever a system message is
created or an alarm event occurs. The email server shall be a valid
SMTP server. Each recipient email address shall be configured
to receive any combination of critical, warning, or
informational messages or alarm notifications. When an
alarm occurs, the email message includes the NVR name, time
of alarm and a list of camera that is configured to record upon
alarm 25) It should support Network Support: HTTP, TCP/IP,
SMTP, DHCP, DNS, DDNS, FTP, NTP, UPnP, Multi IP Setting.
Convert multiple recording files to one avi/MP4 file. 26) General
AI Based Search: Search Pictures by channel, time, event type,
target classification (Fall Detection, People Approach Detection,
People No. Exception Detection, People Staying Detection,
Violence Detection.
27) Alarm Notifications based on: Motion detection,
video tampering, video loss, scene changing, PIR alarm,
29) Built-In Artificial Intelligence: NVR should have built-in AI :-- 2
Channel face detection and recognition, - Minimum 4 Channel
perimeter protection, - Minimum 8 Channel Smart Motion
Detection 30) Face Recognition Database Capacity: It should
support total Blacklist and Whitelist capacity of Minimum 20,000
Faces or more with Face Detection speed of 12 face
images/sec. 31) Face & Human Attributes Search: Search
Pictures/ Video by Gender, age group, glasses, expressions, face
mask, beard, Top color, top type, hat, bag, age, gender and
umbrella. 32) ANPR Capability: It should support ANPR Camera
with License plate, plate color, vehicle body, vehicle model,
vehicle logo, calling, seatbelt, vehicle registration location etc
vehicle attributes. 33) Alarm Notifications based on: Motion
detection, video tampering, video loss, scene changing, PIR
alarm, Camera external alarm, Face detection, face
recognition, perimeter protection (intrusion and tripwire), ANPR,
people counting, stereo analysis, crowd distribution, heat
map, Disk Full, Storage Error, IP Conflict and abnormal
behavior of fan, cybersecurity exception 34) Alarm Notification
should be linked with Recording, snapshots, Camera external
alarm output, buzzer, logs, presets and email. 35) General AI
Based Search: Search Pictures by channel, time, event type,
target classification (Fall Detection, People Approach Detection,
People No. Exception Detection, People Staying Detection,
Violence Detection. 36) Smart
playback function: Should support smart search for the
16 Channel Network Video Recorder (NVR) having
40.10.2 display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16 Each 1 12799.00 12799.00
Hard Disk Drive
Supplying, Installation, Testing and Commissioning following
capacity Serveillance grade Hard Disk with upto 256MB/s
6 40.12 Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form
factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC,
KC, Maghreb, RCM,
UKCA, VCCI, CB-Scheme, TUV, UL Certifications.
7 54.31 CCTV colour CCTV colour monitor
32" flat LED Supply, installation, testing and commissioning of 32" flat LED
54.31.1 colour monitors colour monitors. Each 1 57963.60 57963.60
TOTAL DSR 205852.00
TOTAL NON DSR 57963.60
TOTAL DSR + NON-DSR 263815.60
Name of Project:- Proposed Construction of Jaipur Centre of Excellence, ICMAI Rajasthan
S.No. of Project Sub Head :- 1
Name of Project Sub Head :- ICMAI BUILDING
S.No. of Component :- D
Name of Component :- UPS
Abstract Of Cost
DSR Item DSR sub
S.No. NO. item No, Item Name Description of Item Unit Quantity Rate Amount
2 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing Each 2 8351.00 16702.00
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long
etc. with charcoal/ coke and salt as required.
4 Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode,
5.7 including connection/ termination with GI thimble etc. as required. Metre 110 62.00 6820.00
5 5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, Metre 60 160.00 9600.00
including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be
done by overlapping and with 2 sets of G.I. nut bolt &
spring washer spaced at 50mm)
6 5.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for Metre 30 1246.00 37380.00
connections etc. as required.
7 26.1 Online UPS - Input supply: Single Phase, Output
Supply: Single Phase.
Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power
Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single
Phase output AC Supply. The UPS shall include a Rectifier, inverter,battery bank suitable for 30
minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour
backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along
with provision formanual bypass, suitable isolation transformer for additional protection against neutral
faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate
Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (PulseWidth Modulation)
Technology. The quality of design, manufacturing and inspection process should confirm to the
relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall
>95% at 100% non-linear loads.Current total harmonic distortion(ITHD)/ total demand distortion (TDD)
on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS
cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be
unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load
at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC
single phase 160-270V 50 Hz and delivering output AC supplytrue sine wave single phase 220/230/240
Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating
temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1
meter distance, Protectionfor Under voltage, over voltage, abnormal output voltage, battery over
charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for
watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic
compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and
Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should
be with IGBT Based Inverter Technology,
CommunicationRS232/ RS485/ SNMP port open protocol for BMS integration as per
Online UPS- Input supply: Three Phase, Output supply: Three Phase. Supplying, installation,
8 Testing & Commissioning of following capacity at full load (Unity Power Factor) at operating
temperature 0 to 40 0C, Relative humidity 0 to 95%, Online double conversion true sine wave
Uninterrupted hot swapable (allow for the replacement or addition of battery modules without
shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes
total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery
26.2 bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of
UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and
Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional
protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS
systems offered are to be of the latest technology with Digital Control Microprocessor based for
reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3
Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection
process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating
efficiency of the UPS systems shall be
>96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current
total harmonic effect(ITHD) on the input grid shall be < 5% at 50
%load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme
power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be
unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load
at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC : 3Phase
400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of
120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance,
protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over
current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must
comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I
and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. . Communication
RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT
Communication as per approved by Engineering in charge. Required battery racks and
interconnecting copper conductor cables of suitable size and connectors and all required
accessories are inclusive of the cost). This system must provide a means for logging and alarming
of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy
(if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter
distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD
Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED) to display : a)
Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage,
frequency, Current. d) Battery:
Voltage, Capacity. e) Load: KVA, KW, Percentage. f) Temperature: STS, Inverter, PFC. g) Event
Logging & Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like:
Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail /
Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total
Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS
Fault /Battery charging and discharging, overload, battery voltage and battery capacity.
j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under
Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over
Temperature. The UPS should have QR code which should contain drawing, test report OEM manual,
Geo- Tag of manufacturing location etc
24.2.1 10KVA (Each Power module shall be < 10 KVA) Each 1 208893.00 208893.00
24.2.2 20KVA (Each Power module shall be < 10 KVA) Each 0 341772.00
TOTAL DSR 325289.00
TOTAL NON DSR 0.00
TOTAL DSR + NON-DSR 325289.00
Name of Project:- Proposed Construction of Jaipur Centre of Excellence, ICMAI Rajasthan
S.No. of Project Sub Head :- 1
Name of Project Sub Head :- ICMAI BUILDING
S.No. of Component :- D
Name of Component :- LIFT
S.No. DSR Item NO. DSR sub Item Name Description of Item Unit Quantity Rate Amount
item No, if any
Supplying, Installation, Testing & Commissioning of following
capacity passenger Machine room less (MRL) lift with regenerative drive
as per CPWD General Specification for Electrical Works (Part-III Lift &
Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having
provision for barrier free access as per Harmonised Guidelines &
Standards for Universal Accessibility in India - 2021 of MoHUA,
serving different floors in the lift shaft as per detailed specifications
enclosed and as under including all other equipment and accessories
complete as required:- (i) Speed-1 MPS (ii) Floors-5 (G+4) (iii) Travel -
17 Meters (approx.) (iv) Stops & opening- 5 stops and 5 openings (v)
Controller: A.C. variable voltage & variable frequency (vi) Automatic
rescue device (ARD) complete with dry maintenance free
batteries as required. vii) Operation: Microprocessor based single
automatic push button/simplex selective collective/duplex collective
selective with/without attendant (viii) Power-415 Volts+10%, 3 phase,
50 Hz, 4 wires system (ix) Car Enclosure: Stainless steel scratch
proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and
stainless steel decorative ceiling with fans (indirect throw) and LED
fitting. (x) The car flooring should be smooth and antiskid as approved
by engineer-in-charge. (xi) Type of doors (a) Car: Power operated,
centre opening horizontal sliding stainless steel scratch
Rock/Honeycomb/ Hairline Finish). (b) Landing doors: stainless steel
scratch proof .
(xii) A hand rail not less that 600mm long at 900mm above floor level to
be fixed adjacent to control panel in the lift car.
(xiii)Voice announcement system in the car to
announce the position of the elevator in the hoist way as the car passes
or stops at floor served by the elevator.
(xiv)Closed loop Control System, protection against power fluctuation,
self diagnostic control, Landing doors 2 hours Fire rated, Overload
detection and protection, Overspeed Governer, Dot Matrix LED D &
P Indicators In Car & Landings, BMS Compatibility, tamper proof
infrared curtain covering almost the entire height of the lift car door, Alarm
horn, Anti Nuisance Operation, CCTV camera system with
4 MP IP camera, suitable NVR and HDD for 30 days storage
backup , Firemen switch, 2/3 way intercom, Emergency Stop
Switch with battery backup for fan and light fitting for 1 hour, pit ladder.
(xv) The lift doors shall have a vision panel to enable persons with
hearing impairment to signal for help or assistance in the event of an
(xvi)An appropriate technological support be provided (Through
emergency messaging |services or alarms etc.) to respond to the
emergency requirements of person with hearing impairment or
deafness. (xvii) In case of failure of ARD or other electronic devices,
a provision of manual rescue be provided
2 Add extra for machine Add extra to item no. 44.1for machine room less (MRL) lift in place of
44.4 room less (MRL) machine room directly above the hoist way.
44.4.1 4-13 Passenger Extra cost for machine room less (4-13 Passenger) Each 1 162000.00 162000.00
3 44.6 Gong system Add extra to item no. 44.1 for hall lantern and arrival gong
4 44.6.1 Extra cost/floor Extra cost for per floor per lift Each 3 21600.00 64800.00
TOTAL DSR 1684225.72
TOTAL NON DSR 226800.00
TOTAL DSR + NON-DSR 1911025.72
Name of Project:- Proposed Construction of Jaipur Centre of Excellence, ICMAI Rajasthan
S.No. of Project Sub Head :- 1
Name of Project Sub Head :- ICMAI BUILDING
S.No. of Component :- D
Name of Component :- EXTERNAL FEEDER LINE ELECTRIFICATION
Abstract Of Cost
S.No. DSR Item DSR sub item Item Name Description Of Item Unit Quantity Rate Amount
2.22 Providing and fixing H.T. danger notice plate of 250 mm X
200 mm, made of mild steel, at least 2 mm thick, and
1 vitreous enamelled white on both sides, and with inscription each 8 340 2720.00
in single red colour on
front side as required.
Supplying and erection of galvanised stay set for 11 KV
over head lines complete with 19/ 20 mm dia X 1.8 metres
long stay rod, anchor plate of size 45 cm X 45 cm X 7.5
mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600
mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain
insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse
sand : 6 graded stone aggregate 40 mm nominal size )
foundation including excavation and refilling etc. as
3 14.10 Supplying and erection of 11 KV pin insulator complete with 2220.00
large steel head G.I. pin, nuts, Each 6 370
washers etc. as required.
14.11 Supplying and erection of 11 KV disc insulator for 11 KV
over head lines with galvanised insulator fittings, ball and
4 socket type and complete with galvanised strain clamps, each 6 1086 6516.00
bolts, nuts, washers
etc. as required.
5 Painting of Painting of poles
Prima coat with Prima coat over new steel and other metallic surface with Per sq
red oxide zinc red oxide zinc chromide paint complete with supply of meter
chromide material labour etc.including preparation of surface. 99 91.20 9029.00
6 Prima coat with Prima coat with aluminium paint, brushing complete with per sq 99 115.20 11405.00
aluminium material and labour including preparation of surface meter
RS Joist/H- Supply of support for overhead line RS joist of
7 Beam I.S. standard including drilling of required hole etc.
complete as required
H - Beam H - Beam 152x152mm, Std weight 37.1Kg/Mtr meter 110 3411.60 375276.00
AAAC Supplying and drawing all aluminium alloy conductor
conductors (AAAC) of approved make conforming to IS 398-1979 Pt.
IV, including binding at existing insulator, jointing,
jumpering, tearing off, connecting etc. as required including
clearing of obstacles (if any)
Raccoon AAAC 0.075 sq inch (80 sq.mm Al. EQ.)- Km. 1.5 95682.00 143523.00
Guard wire/earth Supplying and drawing guard wire/earth wire/bearer wire
wire/bearer wire 13 sq mm (4mm. dia) G.I. including stringing, binding at
13 sq mm existing insulators or brackets, jointing, jumpering,
connecting & cradle etc. as required and clearing of
Guard wire/earth Supplying and drawing guard wire/earth wire/bearer wire 18.62
wire/bearer wire sq mm (4.87mm. dia/6swg) G.I. including stringing, binding at
10 18.62 sq mm existing insulators or brackets, jointing, jumpering, connecting & km. 1.0 22513.20 22513.00
cradle etc. as required and clearing of obstacles (if any)
Erection of poles, Erection of RS Joist pole/'H' beam/steel tubular/steel rail pole of
length exceeding length exceeding 10 metres but not exceeding 15 metres in
10 metres but not cement concrete M-10 (1 cement:3 core sand: 6 graded stone
exceeding 15 aggregate 40mm nominal size) base, foundation, muffing
metres including excavation and back refilling etc. as required.
Angle/channel/ flat Supply, fabrication and erection of angle/channel/flat iron fitting
iron fitting for for overhead line & sub-station etc such as 'D' bracket, cross
overhead line & arms, top clamp, 'V' cross arms, back/support clamp or other
sub-station etc similar work etc. including nut bolts of required size, making
holes, fabrication, welding, cutting, etc. and painting with one
coat of red oxide paint & two coat required as per
specificationof aluminium paintas
G.I. earth coil of Supply, laying and fixing of G.I. earth coil of 4mm dia G.I.
4mm dia wire having 120 turns of nearly 50mm dia. and 3 mt. long
13 tail inexisting pit duly earthed with pole etc complete as each 8 351.60 2813.00
required as per specification
TOTAL DSR 60592.00
TOTAL NON DSR 687832.00
TOTAL DSR + NON-DSR 748424.00
Sub. Engineer (E/M) Asst. Engineer (E/M)
Name of Project:- Proposed Construction of Jaipur Centre of Excellence, ICMAI Rajasthan
S.No. of Project Sub Head :- 1
Name of Project Sub Head :- ICMAI BUILDING
S.No. of Component :- D
Name of Component :- EXTERNAL SUB STASTION ELECTRIFICATION
Abstract Of Cost
DSR Item DSR sub
S.No. NO. item No, if any Item Name Description Of Item Unit Quantity Rate Amount
1 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick
including accessories, and providing masonry enclosure with cover
5.5 plate having locking arrangement and watering pipe of 2.7 Meter Each 3 13755.00 41265.00
with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below Metre
ground as strip earth electrode, including connection/ terminating
with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall
be done by overlapping and with 2 sets of G.I. nut bolt & spring
washer spaced at 50mm)
5.10 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia Metre 40 1638.00 65520.00
G.I. pipe from earth electrode including connection with brass nut,
bolt, spring, washer
excavation and re-filling etc. as required.
4 11.1 Gland & Lugs
Supplying and making end termination with brass compression
gland and aluminium lugs for following size of PVC insulated and
PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade
5 Supplying and making outdoor end termination with cast resin
compound including aluminium lugs and other jointing materials
11.2 for following size of PVC insulated and PVC sheathed / XLPE
conductor cable of 1.1 KV grade as required.
Supplying and erection of three piece nonlinear resistor type Set 1
lightning arrestor suitable for 3 wire, 11 KV overhead lines with
rated voltage 9 KV (rms) with a nominal discharge current rating of
5 KA and complete with galvanised clamping arrangement, G.I.
washers etc. as required.
7 supplying and making indoor cable end termination with heat
shrinkable jointing kit complete with all accessories including lugs
23.4 suitable for following size of 3 core, XLPE aluminium conductor
grade as required:
Supplying, installation, testing and commissioning of following
capacity (continuous loading) BEE 5 Star rated (Corresponding
Level as per BIS amended upto date of receipt of tender) , 11/0.433
KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, KNAN
[K(K-Class insulating liquid) Natural Air Natural] copper wound
transformer (Electrolytic grade 99.9% pure copper, Core made of
first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH
or better),Dielectric material shall be type -A, suitable for out
door/indoor applications with Offload Tap Changer in range of
+5% to -15% in steps of 2.5%, having cable end boxes on HV side
suitable for 3x300 sqmm XLPE cable of 11 KV grade, including
bus trunking arrangement on LV side including supplying and
laying of copper conductor multicore control cable from
transformer to HT breaker/panel for safety tripping, complete with
all accessories and safety provisions as per relevant IS 1180 (Part-
3) including first filling of filtered dehydrated Synthetic organic
Ester oil, i/c supplying and grouting of suitable M.S. Channel with
all accessories and transformer shall be confirming to
IS : 2026 (Part 1 to Part 5), IS : 1180 (Part-3) and as per CPWD
specifications complete in all respects etc as required at site. The
maximum flux density in any part
of the core and yoke at rated voltage and frequency
Zone as per location of site, d) Altitude as per location/site. Noise
level Shall not exceed limits as per NEMA TR-1 with all
accessories running measured as per IEC 551 / NEMA standard.
The transformer should have QR code which should contain
drawing, test report OEM manual,Geo- Tag of manufacturing
location etc. Marking Each transformer shall be
provided with rating plate made of anodized aluminum/ stainless
steel material securely fixed on the outer body, easily accessible,as
per IS: 1180 Part 3. The entries on the rating plate shall be indelibly
marked. Fitting and Accessories : The following fittings shall be
a) Two earthing terminals with the earthing symbol b) Oil level
gauge indicating oil level at minimum, 30°C and maximum
operating temperature; c) Air release device (for non-sealed type
transformers) d) Rating and terminal marking plates; e) Silica gel
breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS
554) preferably steel with plug for three phase transformers;
g) Thermometer pocket with cap; h) Oil filling holes having (1¼″
nominal size thread) with cover (for sealed type transformers
without conservator); i) Lifting lugs for the complete transformer as
well as for core and winding assembly; –
j) Pressure relief device or explosion vent above 200 kVA; k) One
filter valve on the upper side of the tank (for transformers above
200 kVA); l) Unidirectional flat rollers (for transformers above 200
kVA); m) Inspection hole (for transformers above 200 kVA); n)
HV side neutral grounding strip (where one of the HV bushing
terminal is connected to earth); o) Buchholz relay for transformers
above 800 kVA. p) Arcing horns or suitable rating lightning
arrestors for HT side3 Nos.
q) Bird guard; r) Oil temperature indicator and winding temperature
indicators for transformers above 200 kVA with suitable tripping
mechanism above permissible limit s) Jacking pads (for transformer
above 1 600 kVA); t) Additional Neutral separately brought out on
bushing for earthing. u) Magnetic oil level gauge (for transformer
above 1600 kVA) with low oil level alarm contact; v) Non return
valve (for conducting pressure test); w) Pressure relief device or
explosion vent x). Monogram Plate y) Inspection cover z).
Detachable type radiators with top and bottom shutoff valve. aa)
Oil Conservator with Oil level indicator, minimum levelmarking
and drain plug for all transformers of capacity
50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for
termination on HV/MV etc. for all
Providing, laying, testing & commissioning of 'B' class medium
duty G.I. pipe conforming to IS 1239 including welding, fittings
like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing
9 27.8 the pipe on the wall/ceiling with suitable clamp/support frame and
painting with two or more coats of synthetic enamel
paint of required shade complete as required :
10 Porcelain Supply & fixing of I.S.I.marked Porecelain Rewireable fuse unit of
rewireable fuse approved make or confirming to I.S.S.
11 Earthing Earthing For Domestic Electrical Installation
Earthing 38.1 Providing and fixing earthing arrangement with
mm dia 2.5 metre 38.1mm dia 2.5 metre long galvanized iron pipe electrode
long galvanized including packing of charcoal powder and salt as per
iron pipe electrode
specification watering pipe 19mm dia G.I. connection,
cover plate having locking arrangement on the top etc. Each 3 4404.00 13212.00
complete with refilling the pit as required, including
excavation of earth pit in soil / soft rock
Add extra for using Add extra for using salt and charcoal/coke for G.I. plate or copper Each
salt and charcoal/ plate earth electrode as required including excavation and refilling
12 coke for G.I the pit in all type of soil, murrum 6 1986.00 11916.00
13 Add extra for using Add extra for using salt and charcoal/coke for pipe earth electrode
salt and as required including excavation & refilling
charcoal/coke for
Excavation Excavation by making hole with auger each 6 1946.40 11678.00
14 XLPE Supply of XLPE insulated power cable (conforming IS 7098 Part-
insulated power I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with
cable, al. alu. stranded /solid conductor
Unarmoured1 Unarmoured 1 core
Outdoor H.T., AB Supplying installing, testing & commissioning of outdoor H.T., AB
switch assembly set switch assembly set gang operated with brass contact parts,
including required GI pipe operating rod, handle & locking
arrangement on On-Off position conforming to IS complete with
required material and installing on existing DP structure to
complete the job as required as per specification.(Set of
D.O. fuse Supplying installing, testing & commissioning D.O. fuse assembly
with brass part contact for 33 or 11/0.4 KV DP Structure set of 3
16 Nos. with fuse barrel i/c required fuse element & other materials as
per specification on existing D.P. structure as required.
Fencing of chain Supply & fixing fencing of chain link mesh 100 x 100 mm, 12
link mesh 100x100 SWG GI wire for for D.P. structure electric sub-station switch yard
mm, 12 SWG including single post of angle iron size 50x50x5mm, 2.5 mt long
GI wire should be provided upto 2.00 mt. apart or as required. The panel
frame with required angle iron/ flat iron members/cross members
including mesh welded in frame panel shall be erected between the
posts. The angle iron post shall be erected in cement concrete M-15
17 (1:2:4) (20 mm graded metal) foundation, including excavation of sq.mtr. 48 2185.20 104890.00
pit and refilling the same. The fencing shall be provided with one
entrance gate including locking arrangement as required as per
specification. The height of fencing shall be 2 mt. above ground
level. Fencing shall be painted with required shade.
TOTAL DSR 647591.00
TOTAL NON DSR 237130.60
TOTAL DSR + NON-DSR 884721.60
Name of Project:- Proposed Construction of Jaipur Centre of Excellence, ICMAI Rajasthan
S.No. of Project Sub Head :- 1
Name of Project Sub Head :- ICMAI BUILDING
S.No. of Component :- D
Name of Component :- EXTERNAL LT DISTRIBUTION LINE ELECTRIFICATION
Abstract Of Cost
S.No. DSR Item DSR sub item Item Name Description Of Item Unit Quantity Rate Amount
1 2.2 Providing and fixing following rating and breaking capacity
and pole MCCB with thermomagnetic release and terminal
spreaders in existing cubicle panel board including drilling holes
in cubicle panel, making connections, Ics=100% Icu and
Operational Voltage 690V etc. as required.
2 11.1 Gland & Lugs
11.1 Supplying and making end termination with brass compression
gland and aluminium lugs for following size of PVC insulated
and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
3 11.2 Supplying and making outdoor end termination with cast resin
compound including aluminium lugs and other jointing materials
for following size of PVC insulated and PVC sheathed / XLPE
conductor cable of 1.1 KV grade as required.
4 22 Cable laying Cable laying
22.1 Description Laying of one number PVC insulated and PVC
sheathed / XLPE power cable of 11 KV grade of following size
direct in ground including excavation, sand cushioning,
protective covering and refilling the
trench etc as required.
22.1.2 Above 120 sq. mm and upto 400 sq. mm Metre 40 694.00 27760.00
22.3 Laying of one number PVC insulated and PVC sheathed / XLPE
power cable of 11 KV grade of following size in the existing
RCC/ HUME/ METAL
pipe as required.
22.3.2 Above 120 sq. mm and upto 400 sq. mm Metre 60 170.00 10200.00
Providing, laying, testing & commissioning of 'B' class medium
duty G.I. pipe conforming to IS 1239 including welding, fittings
like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and
6 27.8 fixing the pipe on the wall/ceiling with suitable clamp/support
frame and painting with two or more coats of synthetic enamel
paint of required shade complete as required :
LT panel Supply, fixing, testing & commissioning wall/floor mounted Kg
LT panel primer coated with powder coated paint &
provided with required gasket for dust/vermin proof with
degree of protection IP42 suitable for 415Volt 3 phase, 50
Hz, 4 wire system fabricated out of CRCA sheet upto 2
mm thick (1.6 mm for doors) duly compartmentalized for
incomer, bus section, outgoings, cable alleys & CT, PT
Ampere Metre, Volt Metre, selector switches, frequency
Metre, phase indicating lamp, Energy Metre complete
7 including cost of 110 476.40 52404.00
busbar supports, detachable cable gland plates, 2 earthing
terminals, internal wiring & fixing of separately supplied
MCBs, MCCBs, ACB, panel mounted changeover
switch/SFUs, etc. as required but excluding cost of busbar
strips, Ampere Metre, Volt Metre, selector switch as per
approved design & specification
8 LT panel Supply and fixing of LT panel accessories of approved
accessories make in existing LT panel including connections etc. as
required as per specification.
Copper bus Copper bus bar strips with PVC sleeves Kg 38.5 945.60 36405.60
9 XLPE Supply of XLPE insulated power cable (conforming IS-7098 Part-I)
insulated 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu.
power cable, al. stranded /solid conductor
3½ core 3½ core armoured
High-tension Supply of approved high-tension XLPE cable (conforming
XLPE cable, 3 IS-7098/II/85) as per ISI standard 3 core armoured with alu.
10 core armoured al. solid/stranded conductor ISI marked as required
3 core XLPE 3 core XLPE cable 11 Kv grade
cable 11 Kv grade
Double wall Supplying and installing double wall corrugated pipes (DWC) of
corrugated pipes HDPE (IS 14930 Part II -marked) for cable laid underground
(DWC) of HDPE with necessary material and at required depth upto 90cm. below
road/ground surface, excluding excavation, back filling with
excavated material, ramming and making the surface good.
120.00mm 120.00mm outside dia. Metre 50 334.80 16740.00
TOTAL DSR 376592.00
TOTAL NON DSR 364269.60
TOTAL DSR + NON-DSR 740861.60
Name of Project:- Proposed Construction of Jaipur Centre of Excellence, ICMAI Rajasthan
S.No. of Project Sub Head :- 1
Name of Project Sub Head :- ICMAI BUILDING
S.No. of Component :- D
Name of Component :- STREET LIGHT
Abstract Of Cost
S.No. DSR Item DSR sub Item Name Description of Item Unit Quantity Rate Amount
NO. item No, if
LED Street light fixture, powder coated pressure die cast aluminium
body (System lumen efficacy ≥105 85%, Input voltage: 140-270 Volt
AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal
surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver
66,IK-10, CRI >70, under voltage and over voltage protection,
EMI EMC As per CISPR -15, lenses for beam angle as per IESNA type
I/II/III as per the width of the road and the project requirement., suitable to
fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry)
of minimum 50000 Burning Hours with 70% of initial Lumen
maintained till life ends as per LM80 extrapolation IES TM-21-11 report,
1 8.12 per ANSI Bin),SDCM (Standard Deviation Colour Matching)
<5, Maximum power consumption should not more than the
specified rating and Fixture shall be ofrelevant BIS standard
complete in all respect i/c external connections with 1.5
sq.mm FRLS/HFFR, PVCinsulated copper conductor single core
cable and earthing etc. as required with Minimum 5 year
OEMwarranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 &
LM80 Test report and all testingrequired for LED fixtures as per BIS
shall be submitted. Shape size and CCT shall be as approved
byEngineer-in-Charge as per requirement. (Thermal management: heat
sink of aluminium housing suchthat LED junction temperature shall
not rise above 90°C).
2 Multi core Supply and fixing of multi core round FR-LSH PVC insulated
flexible cables copper (flexible) conductor & PVC sheathed cables 1100Volts as
per IS:694-1990 of approved make
Three core 1.5 (30/0.25 mm) Three core 1.5 sq.mm. Metre 100 60.00 6000.00
Post top lantern LED Supply and fixing integral post top lantern LED fitting comprises of
fitting copper dust finish cast aluminium spigot and spun aluminium canopy
fixed with opal polycarbonate, pipe arrangement for vertical mounting,
open construction driver and accessories are wired upto terminal block.
LED of 1 to 3 Watt each assembled on single MCPCB, having color temp
upto 6500K & having 50000 burning hrs. life with minimum @ L
70, system lumen output should be minimum with
efficacy>100lm/Watt. LED driver PF > 0.95 & surge protection 10KV.
The colour rendering index of LED light should be more than 70.
Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c
wire, testing etc. to complete the job.
25W 25 Watt LED, color temp 3000-6500k as required. Each 2 4927.20 9854.40
4 XLPE insulated Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 0.00
power cable, al. 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu.
conductor stranded /solid conductor
4 core 4 core armoured 0.00
25 sq. mm 25 sq. mm Metre 0 334.80
Double wall Supplying and installing double wall corrugated pipes (DWC) of
corrugated HDPE (IS 14930 Part II -marked) for cable laid underground with
pipes (DWC) of necessary material and at required depth upto 90cm. below
5 HDPE road/ground surface, excluding excavation, back filling with excavated 0.00
material, ramming and making the surface good.
63.00mm 63.00mm outside dia. Metre 150 210.00 31500.00
6 Octagonal poles Providing and erection of hot dipped galvanized octagonal poles in single 0.00
section made from 3mm thick sheet having lockable weather proof flush
door junction box, suitable size & type of foundation bolts 4 nos. 'J' type
(EN8 grade) complete, erected in an approved manner on provided
7 8 meter 8 meter height, 135 X 70mm A/F, 225x225x16mm base plate having Each 8 16098.00 128784.00
weight 70 kg ± 3%, 4 nos. X 20 x 750mm bolt
having weight 8.2 kg ± 3%.
8 Sword canopy type Providing and fixing of sword canopy type single arm GI bracket Each 8 2485.20 19881.60
single arm GI bracket upto 2 meter Long for 90mm A/F top octagonal pole
Bakelite sheet Providing and fixing of bakelite sheet 10mm thick, one MCB 6Amp-
MCBSP & stud type 32Amp SP & 16sq.mm stud type 4 way epoxy connector for decorative
4 way epoxy designer poles /octagonal pole box.
9 connector for Each 5 387.60 1938.00
/octagonal pole
Foundation for Designing and construction of footing foundation for octagonal
octagonal pole pole of desired size including excavation in soil/soft rock, base
concrete M-7.5 (1:4:8), 15mm thick and pedestal of RCC M-20
(1:1.5:3), required tar steel reinforcement for required size from
10 base concrete, shuttering, curing etc. with existing foundation Cu. Mt. 4 8124.00 32496.00
bolts complete as per specifications in an approved manner as per
manufacturer drawing or engineer-in-charge.
TOTAL DSR ITEMS 14256.00
TOTAL NON DSR ITEMS 276114.00
TOTAL DSR + NON DSR ITEMS 290370.00
6A sep. board 6A sep. board 6A sep. board 6A sep. board 6A sep. board 6A 6A 6A sep. board 6A 6A sep. board 6A sep. board 6A sep. board 6A sep. board
Name of Project:- Proposed Construction of Jaipur Centre of Excellence, ICMAI Rajasthan
S.No. of Project Sub Head :- 1
Name of Project Sub Head :- ICMAI BUILDING
S.No. of Component :- D
Name of Component :- ADDRESSABLE FIRE ALARM SYSTEM
S.No. DSR Item NO. DSR sub Item Name Description of Item Unit Quantity Rate Amount
item No, if any
28.5 CABLING & WIRING
Supplying & laying of 2x1.5 sqmm fire survival armoured
cable, 600/1000V rated with annealed copper conductor
1 28.5.1 having glass mica fire barrier tape covered by an Metre 200 386.00 77200.00
28.2 INTELLIGENT FIRE ALARM SYSTEM
Supplying, installation, testing and commissioning of micro processor
based intelligent addressable main fire alarm panel, central
processing unit with the following loop modules and capable of
supporting not less than 240 devices (including detectors) and
minimum 120 detectors per loop and loop length up to 2 km, network
communication card, minimum 320 character graphics/ LCD display
with touch screen or other keypad and minimum 4000 events
history log in the non volatile memory (EPROM), power supply
unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed
maintenance free batteries with automatic charger.The
2 panel shall have facility to connect printer to printout log and
facility to have seamless integration with analog/digital voice
evacuation system (which is part of the schedule of work under
SH: PA System) and shall be complete with all accessories The
panel shall be compatible for IBMS system with open
protocol BACnet/ Modbus over IP complete as per pecifications.
Supplying, installation, testing & commissioning of repeater panel
with 320 character/ Touch screen LCD display with inbuilt
4 28.2.3 reset, acknowledge and silence switches complete as required. Each 3 113734.00 341202.00
5 28.2.5 Supplying, installation, testing & commissioning of response Each 25 306.00
indicator on surface/recessed MS Box having two LED, metallic
cover complete with all connections etc as required.
6 28.2.9 Supplying, installation, testing & commissioning of intelligent Each 20 2866.00
addressable thermal detector with rate of rise cum fixed
temperature thermistor complete with
base as required.
Supplying, installation, testing & commissioning of addressable
7 28.2.14 manual call point complete as required. Each 3 4063.00 12189.00
Supplying, installation, testing & commissioning of addressable
8 28.2.15 horn cum strobe complete as required. Each 3 3682.00 11046.00
MPPWD SOR 0.00
Addressable control Supply, installation, testing and commissioning of addressable
relay module control relay module with inbuilt isolators & with flexible
9 49.16 network structures with a maximum switching current of 1A @ Each 1 21640.88 21640.88
be UL/EN54 certified
Providing and fixing Stored Pressure (ABC Dry
Chemical Powder) type Fire Extinguisher of
Capacity 6 kg Confirms to IS 15683, bearing ISI
marked complete with brass forged squeeze grip
type valve fitted with pressure gauge , pressurize
with dry Nitrogen gas filled, with discharge
nozzle with wall mounting bracket, having fire
rating of 3A & 89B.
'Providing and fixing Stored Pressure Water type
Fire Extinguisher of Capacity 9 Ltr Confirms to
IS 15683, bearing ISI marked complete with
brass forged squeeze grip type valve fitted with
pressure gauge , pressurize with dry Nitrogen gas
filled, with discharge nozzle with wall mounting
bracket, having fire rating of 3A.
TOTAL DSR 757027.00
TOTAL NON DSR 49826.95
6A sep. board 6A sep. board 6A sep. board 6A sep. board 6A sep. board 6A 6A 6A sep. board 6A 6A sep. board 6A sep. board 6A sep. board 6A sep. board
TOTAL DSR + NON-DSR 806853.95
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.06 MB
NIT.pdf
Tender Document
All Tech Audit Circulars.pdf
Tender Document
GCC 2026 WITH UPTO 4TH AMENDMENT.pdf
Tender Document
drawing.pdf
Tender Document
INTEGRITY PACT.pdf
Tender Document
MAKE list.pdf
Tender Document
SCC NEW.pdf
Tender Document
Soil test report.pdf
Tender Document
ICMAI BOQ Final.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .