GM-(CIVIL)
Main Administrative Building Sector-6 Noida
M/o STP (Existing STP based on SBR Technology core Parts (Decanter core part, diffuser, PLC SCADA and Related work) (Renovation and Strengthening work of the existing 50 MLD STP Core Parts with MPS at Sector-168) Noida (PART-A)
2026_NOIDA_1156673_1
09/SM(JAL-OA)/26-27
Open Tender
Civil Works - Others
365 days
NOIDA
Please refer Tender documents.
3 documents required · 3 mandatory
₹8,260
Yes
NOIDA
₹49.3 L
3 Jun 2026
3 Jun 2026
17 Jun 2026
3 Jun 2026
16 Jun 2026
3 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | PUMP HOUSE:
a) Replacement of Coarse Screens 2 Nos
Screen Chamber : 3 Nos.
FB Avg. Flow to Each Screen-25.0 MLD
Peak Flow to Each Screen-56.25 MLD
Type Inclined Multi Rake Bar Screen
Angle of Inclination - 75 deg.
Clear Opening -20mm
Flat Size 20x 10mm
Bar Profile Rectangular
Operating Height/Chanel Depth - 5 m. & all complete work as above items. direction by Engineer-in-charge
b) Cleaning & Desilting of Sump well size- 125.0 m Dia. x 2.50 m SWD & all complete work as above items. direction by Engineer-in-charge
c) Replacement/Repairing of Electrical Control Panel along with Cabel & Cabel Trays & all complete work as above items. direction by Engineer-in-charge
d) Repair Work of inlet, outlet & Bypass gate Valves, Belt Conveyars & EOT Crane & all complete work as above items. direction by Engineer-in-charge | 1 | Job | 2,41,29,600 | ₹2,41,29,600 |
| 2PRIMARY UNIT a) Replacement of Existing Flow Meter & all complete work as above items. direction by Engineer-in-charge b) Replacement of Fine Bar Screens 2 Nos with hydraulic power pack system Screen Chamber : FB Avg. Flow to Each Screen-25.0 MLD Peak Flow to Each Screen-56.25 MLD Type - Step Angle of Inclination - 45 deg. Clear Opening -6mm Flat Size- 2mm Bar Profile: Rectangular Operation: Automatic & all complete work as above items. direction by Engineer-in-charge c) Cleaning & Desilting of Grit Chamber size 7.1 m x 7.1 m x 0.9 m SWD & all complete work as above items. direction by Engineer-in-charge | |||||
| 2.01 | d)Replacement of Grit Scrapping Mechanism, Screw Conveyor,Organic return pump & Gear Box of Grit mechanism unit –2 Nos
Grit Chamber cap :
Avg. Flow -25.0 MLD
Peak Flow -56.25 MLD.
Type of mechanism - Mechanical Scraper & Screw Classifier & all complete work as above items. direction by Engineer-in-charge
e) Repair work Gate Valves, Cleaning of Grit Chamber & other miscellaneous works etc & all complete work as above items. direction by Engineer-in-charge | 1 | Job | 1,80,56,775 | ₹1,80,56,775 |
| 3SBR UNIT a) Replacement of Decanter Screw Jack + Core parts+ Diffuser membranes & SS Clamps+PLC/SCADA System (non-redundant) & all complete work as above items. direction by Engineer-in-charge b)Cleaning of SBR Basin & Selector Zones 4 nos.Size of 38.80m (L) x 38.80m (W) x 5m (SWD) & all complete work as above items. direction by Engineer-in-charge c) Provision of DO Analyzer’s at each basin Diaphragm covered, amperometric, potentiostatic operating 3 electrode system or Photometric sensor also acceptable. • Fast calibration • Automatic diaphragm break alarm • No zero point adjustment necessary • Minimum measuring range 0.01 mg 02/1 • Diaphragm easy to replace • Electrolyte reservoir for 1.5 year of operation • Integrated Temperature sensor Reaction time: 30 sec. (for 90% of total value) Temperature 100 sec. (for 99% of total value) 5- 35 deg C Protection class: IP 68 • Measuring range : 0-10 mg 02/1 • Resolution of data: </ = 0.5% of total value & all complete work as above items. direction by Engineer-in-charge . | |||||
| 3.01 | d) Replacement/Repairing of air line from blower discharge to SBR Unit & all complete work as above items. direction by Engineer-in-charge
e) Replacement of RAS/SAS Pumps unit –8 Nos
RAS Pump Capacity - 365 m3/hr @0.60 Kg/cm2, @ 10m head
SAS Pump Capacity - 75 m3/hr @ 10m head
Type-Submersible Non Clog
Speed-Less than 1000 RPM
Handle Solid Size 100mm
Specific Gravity - 1.05
Operation start and stop automatically based on the level in the wet well (VFD Suitable), Motor Cooling System - Cooling Jacket
Accessories Lifting Chain Bow Shackle at every Im -10m
Length each Pump
Guide Pipe with square Guide rail bar 10m Length each Pump
Cable Length - Min. 20m
All required Pump Protection Water Leakage Detector, Bearing Temperature Detector, Thermal Overload Protection, Seal Detector etc & all complete work as above items. direction by Engineer-in-charge
f) Replacement/Repairing of corroded cable & cable trays & all complete work as above items. direction by Engineer-in-charge
g) Repair work of Actuators, Provision of pump lifting arrangement & other miscellaneous works & all complete work as above items. direction by Engineer-in-charge . | 1 | Job | 7,44,90,034.52 | ₹7,44,90,034.52 |
| 4 | BLOWER HOUSE
a) Replacement of 2 Nos of Turbo Blowers as a stand by arrangement Capacity - 4900 Nm3/h @0.60 Kg/cm2 & all complete work as above items. direction by Engineer-in-charge
b) Replacement of Twin Lobe Blower with Motors Unit – 4 Nos
Air mixing rate - 1.2 m3 / hr /m3 of liquid volume
Min. Blower Capacity - 4900Nm3 / hr
Head - 0.6 Kg/cm2 & all complete work as above items. direction by Engineer-in-charge
c) Modification of air transfer pipeline & all complete work as above items. direction by Engineer-in-charge
d) Retrofitting/Replacement of Electrical control panel with cable & cable trays & all complete work as above items. direction by Engineer-in-charge
e) Retrofitting/Replacement of Electrical control panel with cable & cable trays & all complete work as above items. direction by Engineer-in-charge
f) Repair work of Blower Discharge valves, repair of EOT crane & other miscellaneous works & all complete work as above items. direction by Engineer-in-charge | 1 | Job | 4,42,82,700 | ₹4,42,82,700 |
| 5 | CENTRIFUGE WORKS
a) Replacement of existing centrifuge with the supply of screw press unit – 2 Nos
Sludge Volume - 670.31 m3/day
Capacity - 14m3/hr.
Sludge flow rate - 41.89 m3/hr
Sludge Consistency - 0.80%
Sludge loading rate - 335.16 Kg/hr & all complete work as above items. direction by Engineer-in-charge
b) Replacement of Sludge Feed pumps unit –6 Nos Capacity - 20 m3/hr. @ 15m & all complete work as above items. direction by Engineer-in-charge
c) Replacement of Polyelectrolyte dosing pumps unit –6 Nos Centrifuge/ Dewatering Unit No of units : 4 Nos ( 3w + 1s)
Type: Solid bowl centrifuge
Capacity of each unit: 20 m3 / hr
Operating hrs: 16 hrs (Maximum)
Mixing of polyelectrolyte: on line
PE Dosing System
Dosing tank No of units: 2 No
Dosage of PE: 1.2-1.5 kg/ ton of dry solid
Solution strength: 0.1 %
Capacity: 8 hrs storage requirement
Mixer speed: 100 RPM,Dosing Pump No of units: 4 Nos (3w + 1s)
Type: Positive displacement, Capacity: Maximum hourly requirement & all complete work as above items. direction by Engineer-in-charge
d) Retrofitting/Replacement of Electrical control panel with cable & cable trays & all complete work as above items. direction by Engineer-in-charge
e) Repair work sludge transfer pumps, poly dosing pumps, repair of EOT crane & cleaning of sludge settling tank etc & all complete work as above items. direction by Engineer-in-charge | 1 | Job | 1,79,14,694.6 | ₹1,79,14,694.6 |
| 6 | CHLORINATION ZONE, DG SET & LABORATORY
a) Replacement of Laboratory Equipment’s,Chemicals & Glassware’s etc.Entire set as per standard & all complete work as above items. direction by Engineer-in-charge
b) Replacement of Chlorination System with the supply of Chlorinators, Leak Detection System, Neutralization unit etc
CCT Tank size - 18m x 11m x 3.5 SWD+0.5 FB
Chlorine dose - 3.5 ppm
Chlorine dosage rate - 4.82 kg/hr.
Chlorinator capacity - 7 kg/hr.& all complete work as above items. direction by Engineer-in-charge
c) Retrofitting/Replacement of Electrical control panel with cable & cable trays & all complete work as above items. direction by Engineer-in-charge
d) Repair work of chlorine booster pumps, EOT crane, major overhauling of DG set etc & all complete work as above items. direction by Engineer-in-charge | 1 | Job | 1,90,46,596.64 | ₹1,90,46,596.64 |
| 7 | MISCELLANEOUS WORKS
a) Replacement of AC units 4 nos. of 2 Ton capacity each & all complete work as above items. direction by Engineer-in-charge
b) Road repair & painting of all existing campus boundary wall & gate/grill , leakproof plaster works & All Structure like as Pump House, Primary Unit, SBR Unit, Blower House Unit, Centrifuge Unit, DG Set Unit, Laboratory, Meeting hall, Administrative Block Unit, Chlorination Unit & all boundary wall of entrie campus as direction by Engineer-in-charge. | 1 | Job | 1,09,45,000 | ₹1,09,45,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
C.xls
Additional Documents • 0.06 MB
TD.pdf
Tender Documents • 4.39 MB
BOQ_2167377.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid