Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹9.9 L+₹57,660.76 (6.15%)Rejected-Finance | L2 | Rejected-Finance ii lowest bidder | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
29 Mar 2023, 1:00 pmClosed
SE Civil OanM
Vidyut Bhawan, Near ISBT Crossing,Saharanpur Road, DEHRADUN
Annual MandR works of Residential and Non-Residential Building at 132 Kv substaion Manglour Haridwar
2023_PTCU8_56289_1
29_SEC_OandM_22-23
Open Tender
Civil Works
Item Rate
365 days
Manglour
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
EE Civil OanM PTCUL
₹29,000
5 Sept 2023
15 Mar 2023
29 Mar 2023
15 Mar 2023
29 Mar 2023
15 Mar 2023
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge.: All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Surface dressing of the ground including removing vegetation and in?equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along the external wall below concrete or masonry apron us ing chemical emulsion @ 2.25 litres per linear metre includ ing drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ)
Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls Under 20 cm wide
Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.Mild steel and Medium Tensile steel bars
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia& Paisalength ( hold fast lugs or dash fastener shall be paid for separately).: (Sal wood)
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glasspanes, including ISI marked M.S.pressed butt hinges bright finished of required size with necessary screws. Second class teak wood 35 mm thick
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (30 mm thick including ISI marked Stainles steel butt hinges with necessary screws.)
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood 50x12 mm
Providing and fixing fly proof galvanised M.S. wire gauge to windows and clerestory windows using galvanized M.S. wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm all complete With .DSR 2nd class teak wood beading 62X19 mm.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete: (100x58x1.90mm)
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete. (250x10mm).
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete. (150x10mm).
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm.
Strutural steel work riveted bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick.
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes. 110 mm diameter.
12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
Lettering with black Japan paint of approved brand and manufacture
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
White washing with lime to give an even shade : Old work (two or more coats)
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work.
Painting with acid proof paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
Providing and fixing C.P. brass chain and rubber plug complete for sink or wash basin: 40 mm dia.
Distempering with 1st quality acrylic washable distemper (ready made)of approved manufacturer and of required shade and colour complete.as per manufacturer's specification.One or more coats on old work.
Finishing walls with water profing cement paint of required shade: Old work (one or more coats aplied @ 2.20kg/10sqm).
Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement : 4 fine sand).
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.Door chowkhats.
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.Window chowkhat.
Fixing chowkhat in existing opening in brick/ RCC wall with dash fasteners/ Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener.
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
Supplying and fixing new wooden fillets wherever necessary: 2nd class teak wood fillets.
Renewal of old putty of glass panes (length
Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete
Providing and fixing bright finished brass helical door spring (superior quality).
Providing & fixing White vitreous china water closet squatting pan (Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.Orissa pattern W.C Pan of size 580x440 mm.
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge.
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer?in-Charge. (a) Internal Work- Exposed on wall
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
Demolishing cement concrete manually/by machanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer?in-charge.
Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar.
Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured) From brick work in cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below.
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :Of area 3 sq. metres and below.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid.
Providing and fixing wash basin with C.I. brackets 15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets cutting and making good the walls wherever require: White Vitreous china Flat back wash basin size 550x400mm with Single 15mm C.P. brass pillar tap.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls , wherever required : Kitchen sink without drain board 610 x 550mm bowl depth 200 mm..
Providing and fixing white vitreous china water closet squatting pan (Indian type ) Orissa pattern W.C. pan of size 580x440mm
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever ) conforming to IS: 7231, with all fittings and fixtures complete. 10 litre capacity-White.
Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings:Flat back wash basin of size550x400 mm
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fitttings complete. Flexible pipe 32mm.dia.
Providing and fixing 600x450mm beveled edge mirror of superior glass (of approved quality ) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing soil, waste and vent pipes 100 mm dia Sand cast iron S&S pipe as per IS: 1729
Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc.15 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc.20mm dia nominal bore
Providing and fixing brass bib cock of approved quality: 15mm nominal bore.
Providing and fixing brass stop cock of approved quality: 15mm nominal bore.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :18.18.1 15 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS IS.49.1.15mm nominal bore.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore.
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade AC 15)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors,windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade AC 15)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .(Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4 mm thickness (weight not less than 10 kg/ sqm)
Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work .With 15 mm thick tegular edged light weight calcium silicate false ceiling tiles. shall be carried out as per specifications, drawing and as per directions of Engineer-in-Charge
Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer's specification as per direction of Engineer-in-Charge all completeWith 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B.
Power plug wiring in PVC conduit (2x4 sq.mm.) ,wiring for light/power plug with 2x4 sqmm.FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, alongwith 1no.4 sqmm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Wring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group B.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 4 sq. mm
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 15/16 amps switch.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 amp socket outlet .
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 amp socket outlet .
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required. 63A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.63 A
Providing Carpenter Service for 8 hours service in a day or part as per requirement by experienced Carpenter with necessary T& PaisaP for attending minor type of repairing work as directed by the Engineer-In-Charge
Providing Wireman service for 8 hour’s service in a day or part as per requirement by experienced electrician with necessary Kit (holding license and T& PaisaP) for attending all type of electrical defects as directed by the Engineer-in-Charge.
Providing beldar service for 8 hours service in a day or part as per requirement to carry out the works as directed by the Engineer-In-Charge.
Providing fitter for Plumber service for 8 hours service in a day or part as per requirement by experienced Plumber with necessary Kit for attending minor type of all water supply defects as directed by the Engineer-in-Charge.
Supply, installation, testing & commissioning of celling fan Havell's make ES-50 5 Star rating model fan sweep 1200mm, including wiring the down rods of standard length (up to 30 cm with 1.5 sqmm FR PVC insulated copper conductor, single core cable, including providing & fixing phenolic laminated sheet cover on the fan box etc. as required. ( Based on market rate + DSR 2014 - 1.45).
Providing water proofing treatment on roof and wall by Dr. Fixit Pidicrete URP compound of pidilite make cleaning of surface with wire brush. Mixing of pidicrete URP compound (1 part of compound, 1.50 part of cement as permanufacture instruction) and apply its two coats on leaky surface @ average 0.50 kg/sqm for two coats by skilled labour as per instruction of manufacturer and applying top coat of 12 mm cement plaster 1:4 cement and coarse sand mortar including cost of all material labour T&P etc required proper completion of the work.
Rewinding of burnt ceiling fan with approved copper wire including cost of all material, labour,T&P and labour etc. complete (Burnt wire shall not be taken back)
Supply and replacing of Damage bearing of ceiling fan. Including cost all T&P and labour etc. for completion etc.
Taking off the defective ceiling fan from position and rechanging after receiving the repaired fan and proper connection etc.
Supply and replacing of wooden board 8"x10" approved quality including all material, labour, T&P & Polishingetc. Required for proper completion of work.
Supply and replacing of wooden board 4"x7" approved quality including all material, labour, T&P & Polishingetc. Required for proper completion of work.
Supply and replacing of 15 mm dia tee/socket/ elbow/ bend /nipple etc for repair of pipeline complete. including supply of all material, labour and T& P etc. required for proper completion of the work.
Easing door and Windows including supply of all labour T& P etc. required for proper completion of the work.
Supply an laying chicken mesh of 20 mm hexagonal heavy quality over roofs of joints as per direction of E/I including supply of all labour,T&P & Polishing etc. required for proper completion of work.
Cleaning of septic tank by removal of sludge through sludge pump attached with tractor/Manually including disposal of waste outside the corporation area as per direction of engineer-in-charge including cartage, labour and T&P (for a septic tank of 5 cum)
Hiring charges of welding machine for 8 hours. Per day. With all labour, T&P and including welded rod as required for proper completion of work
Supplying of Drinking water (5000 liter water tanker) at substation from source of municipal water Supply including all T&P, labour as required for proper completion of work.
Providing & Fixing C.P Brass Pillar Cock of approved quality 15 mm nominal bore (weight not less then 400 grms).
Cleaning of inspaction chamber including disposal of waste outside the corporate area as per direction of E/I including cartage, labour and T&P (chamber below 1.00 cum)
Operation of tubwell daily by a suitable experienced operator continuously or in different intervals as per programme fixed by the E/I including opening & closing of valve, changing of fuse wire etc. AS required for proper copmletion of work.
Sweeping of colony roads and srrounding area of residences and disposal of debris/garbage up to the nearest dustbin as per time schedule approved by E/I including cost of all labour and T&P etc. required for proper completion of work (approximate sweeping)
Cleaning of drains upto 0.3m wide and disposal of debris/ garbage up to nearest dustbin including sprinkling of lime powder near drains as per schedule approved by E/I including all labour, material and T&P etc. required for proper completion of work.
Cleaning of Nala more than 0.30 in wide and disposal of debris/garbege up to nearest dustbin including sprinkling of lime powder near nala as per schedule approved by E/I including all labour, material T&P etc. Required for proper completion of work.
Cleaning of Over Head tank capacity up to 1000 Ltrs. With brush, scraping of wall and bottom & disposal of rubbish outside the tank including all labour & T&P etc. Required for proper completion of the work.
Cleaning of Over Head tank capacity from 1001 to 30000 Ltrs. With brush, scraping of wall and bottom & disposal of rubbish outside the tank including all labour & T&P etc. Required for proper completion of the work.
Disposal of garbage/ debris from dustbin of places as directed b E/I outside the substation area including sprinkling of white lime powder in dustbins and surrounding area including cartage, labour, material and T&P etc. required for proper completion of work.
Manual Chlorination of water by adding bleaching power as per direction by Engineer in charge including all labour T&P etc. required of proper completion work.
Supply and Fixing of Wall Swing Fan 300 mm dia Havells make speed 1360RPM, Pull cord control for speed of oscilliation On Off including supply of all material labour T&P etc. required proper completion of work.
Supply and laying of welded mesh (75mmx75mm) of 10 guage wire over roof of joints as per direction of E/I including supply of all, labour T&P etc. required for proper completion of work.
Extraction of defective submersible pump and motor upto 5HP with 32mm PVC/ GI pipe and then lowering of the repaired pump and motor with pipe and testing the same , including checking mains cut outs fuses and operation of tubewell for 24 hrs for its smooth working with all cost of materials, labour T&P etc. required for the proper completion of the work.
Winding of submersible pump of motor upto 5HP vertical type or horizontaal type, including cleaning , oiling greasing drying etc with cost of all material, labour , T&P etc. complete burnt copper wire shall not be taken back from the contractor , approved make copper wire shall be used
Disassembling of up to 5 HP submersible pump Replacing of damaged bush impeller nut &bolts turning of shaft including complete overhauling oiling and greasing the pump as required testing and reassembling the same including cost of all materials labour T&P etc required for proper competion of work.
Supply and fixing star-delta starter with single phase preventer suitable for 10 HP submersible motor – pump of SIEMENS make model no.-3TE0290-OA.7A Ranging from 12.5-20.00 Amp including all labour material cartage etc. required for proper completion of the work
Supplying & Fixing flat submersible cable of superior quality as directed by engineer-in-charge. (3x4.0) sq.mm approved make including all material and T&P etc. Complete.
M/s VEERPAL SINGH CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .