| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.5 LAccepted-AOC | 1 | Accepted-AOC first | |
| 2 | 2₹14.9 L+₹33,108.30 (2.28%)Rejected-AOC | 2 | Rejected-AOC second | |
| 3 | 3₹15.2 L+₹67,356.97 (4.63%)Rejected-AOC KERALA KL | 3 | Rejected-AOC third | |
| 4 | Rejected-Technical VALIYAPEEDIKAKKAL HOUSE MARUTHA POST VAZHIKKADAVU VAZHIKKADAVU 673633 | VAZHIKKADAVU | KOZHIKODE | KERALA | 673633 | - | Rejected-Technical fourth |
Tender Value
₹17.9 L
EMD Value
₹44,630
Closing Date
17 Sept 2020, 1:00 pmClosed
Assistant Engineer LSGD section Vazhikkadavu GP
Office of the Assistant Engineer LSGD section Vazhikkadavu
Annual plan 2020-21,Vazhikkadavu GP,Pro.no.209/20-21.Building Construction for GLPS Vendekumpotty
2020_LSGD_383344_1
E5(1)/AE/2020-21/LSGD/VKD
Open Tender
Civil Works - Buildings
Item Rate
210 days
vazhikkadavu GP
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,500
online
₹44,630
9 Nov 2020
8 Sept 2020
18 Sept 2020
8 Sept 2020
17 Sept 2020
8 Sept 2020
Amount
Building Construction
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.8 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete
od773752/2020_2021 : Providing and fixing in position factory made precast RCC M-25 doors and windows frames having excellent smooth finish with reinforcement of 3 Nos, 6 mm dia main bars tied with 3 mm M.S stirrups placed @ 200 mm C/C etc all complete, as per the direction of Engineer in charge. The frame shall be measured in running meter correct to two places of decimal. Door frame 100 mm x 60 mm
14.29 : Providing and fixing M.S. round or squre bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows.
50.10.2 : Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od774010/2020_2021 : Roofing with G.I. hard colour powder coated trafford sheets .35mm thick or nearest available thickness with overlaps of 150mm at ends and G.I. hook or crank.i. bolts and nuts including plain washers and bitumen washers etc complete.
SHAMSUDHEEN C
SHINE V L
Suneer VP
Bidder Name
SHAMSUDHEEN C
VASU KV
Suneer VP
SHINE V L
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_544141.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .