Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.6 LAccepted-AOC CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | ₹65.6 L Quoted ₹66.7 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹70.4 LRejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | ₹70.4 L | L2 | Rejected-Finance Unsuccessful bidder |
| 3 | L3₹73.0 LRejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | ₹73.0 L | L3 | Rejected-Finance Unsuccessful bidder |
| 4 | L4₹75.7 LRejected-Finance | ₹75.7 L | L4 | Rejected-Finance Unsuccessful bidder |
| 5 | L5₹77.2 LRejected-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | ₹77.2 L | L5 | Rejected-Finance Unsuccessful bidder |
| Sl No | Description | Qty | Unit | M/s.Sai Agency L5 | M/S MECHANICAL ENGINEERING and ELECTRICAL CONTRACTORS L4 | PURBANCHAL BUILDERS L2 | Flint India L3 | D G Corporation L6 | Chinmay Traders L9 | M/S N S CONSTRUCTION L8 | MAHANTA ENTERPRISES L1 | AVASANA SOLUTIONS PRIVATE LIMITED L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fixing in replacement of Indoor/Outdoor LT cable end termination jointing kit ,1100 volt grade (earthed) 3.5/4 core 400 sqmm aluminium conductor XLPE insulated armoured heavy duty cable heat shinkable suitable in/ out door type to be fix on incoming /outgoing connection of LT panel with gland etc at various location for following size :-. | 14 | Each | 5,000 ₹70,000 | 4,808.94 ₹67,325.16 | 1,899 ₹26,586 | 3,500 ₹49,000 | 6,000 ₹84,000 | 5,000 ₹70,000 | 4,936 ₹69,104 | 5,032 ₹70,448 | 5,000 ₹70,000 |
| 2.00 | All as in Item No - 01, but for 3.5 core 240 to 300 Sqmm | 16 | Each | 4,500 ₹72,000 | 3,656.91 ₹58,510.56 | 1,799 ₹28,784 | 3,300 ₹52,800 | 4,500 ₹72,000 | 4,000 ₹64,000 | 3,671 ₹58,736 | 3,789 ₹60,624 | 4,500 ₹72,000 |
| 3.00 | All as in Item No - 01, but for 3.5/4 core 150 to 185 Sqmm | 10 | Each | 4,000 ₹40,000 | 3,399.17 ₹33,991.70 | 1,599 ₹15,990 | 2,400 ₹24,000 | 3,000 ₹30,000 | 3,500 ₹35,000 | 3,671 ₹36,710 | 3,789 ₹37,890 | 3,500 ₹35,000 |
| 4.00 | All as in Item No - 01, but for 3.5/4 core 70 to 120 Sqmm | 25 | Each | 3,800 ₹95,000 | 2,503.81 ₹62,595.25 | 1,399 ₹34,975 | 2,400 ₹60,000 | 2,700 ₹67,500 | 3,000 ₹75,000 | 2,669 ₹66,725 | 2,926 ₹73,150 | 3,500 ₹87,500 |
| 5.00 | All as in Item No - 01, but for 3.5/4 core 25 to 50 Sqmm | 17 | Each | 3,500 ₹59,500 | 2,025.45 ₹34,432.65 | 1,299 ₹22,083 | 2,400 ₹40,800 | 1,500 ₹25,500 | 2,500 ₹42,500 | 2,086 ₹35,462 | 2,173 ₹36,941 | 3,000 ₹51,000 |
| 6.00 | All as in Item No - 01, but for 3.5/4 core 6 to 16 sqmm | 6 | Each | 3,000 ₹18,000 | 1,672.27 ₹10,033.62 | 1,199 ₹7,194 | 1,550 ₹9,300 | 1,200 ₹7,200 | 2,000 ₹12,000 | 1,725 ₹10,350 | 1,862 ₹11,172 | 3,000 ₹18,000 |
| 7.00 | Supply and fixing in replacement of LT cable Straight through jointing kit ,1100 volt grade (earthed) 3.5/4 core 400 sqmm aluminium conductor XLPE insulated armoured heavy duty cable heat shinkable suitable in/ out door type to be fix on incoming /outgoing connection of LT panel with gland etc at various location for following size :-. | 3 | Each | 9,500 ₹28,500 | 4,166.27 ₹12,498.81 | 2,699 ₹8,097 | 3,550 ₹10,650 | 6,000 ₹18,000 | 12,000 ₹36,000 | 4,123 ₹12,369 | 4,662 ₹13,986 | 12,000 ₹36,000 |
| 8.00 | All as in Item No - 07, but for 3.5 core 240 to 300 Sqmm | 3 | Each | 9,000 ₹27,000 | 4,092.63 ₹12,277.89 | 2,599 ₹7,797 | 2,900 ₹8,700 | 4,500 ₹13,500 | 10,000 ₹30,000 | 4,000 ₹12,000 | 4,662 ₹13,986 | 10,000 ₹30,000 |
| 9.00 | All as in Item No - 07, but for 3.5/4 core 150 to 185 Sqmm | 2 | Each | 8,500 ₹17,000 | 3,355 ₹6,710 | 2,399 ₹4,798 | 1,750 ₹3,500 | 3,000 ₹6,000 | 7,000 ₹14,000 | 3,345 ₹6,690 | 4,018 ₹8,036 | 7,000 ₹14,000 |
| 10.00 | All as in Item No - 07, but for 3.5/4 core 70 to 120 Sqmm | 3 | Each | 8,000 ₹24,000 | 2,276.13 ₹6,828.39 | 2,199 ₹6,597 | 1,750 ₹5,250 | 1,850 ₹5,550 | 5,000 ₹15,000 | 2,028 ₹6,084 | 2,678 ₹8,034 | 5,000 ₹15,000 |
Updated dates
Tender Value
₹85 L
EMD Value
₹1.5 L
Closing Date
22 Dec 2025, 6:00 pmClosed
CWE Tezpur
HQ CWE TEZPUR PO DEKARGAON DIST SONITPUR PIN 784501 (ASSAM)
REPAIR/MAINTENANCE OF LT PANEL/FEEDER PANELS, GODOs, MCCBs, STABLIZER WITH CONNECTED WORKS AT SAA UNDER GE(S) TEZPUR
2025_MES_740241_1
8236/TEZ(S)/E8
Open Tender
Electrical and Maintenance Works
180 days
Tezpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (S) Tezpur
₹1.5 L
Yes
29 Jan 2026
17 Nov 2025
27 Dec 2025
17 Nov 2025
22 Dec 2025
8 Dec 2025
Amount
Supply and fixing in replacement of Indoor/Outdoor LT cable end termination jointing kit ,1100 volt grade (earthed) 3.5/4 core 400 sqmm aluminium conductor XLPE insulated armoured heavy duty cable heat shinkable suitable in/ out door type to be fix on incoming /outgoing connection of LT panel with gland etc at various location for following size :-.
All as in Item No - 01, but for 3.5 core 240 to 300 Sqmm
All as in Item No - 01, but for 3.5/4 core 150 to 185 Sqmm
All as in Item No - 01, but for 3.5/4 core 70 to 120 Sqmm
All as in Item No - 01, but for 3.5/4 core 25 to 50 Sqmm
All as in Item No - 01, but for 3.5/4 core 6 to 16 sqmm
Supply and fixing in replacement of LT cable Straight through jointing kit ,1100 volt grade (earthed) 3.5/4 core 400 sqmm aluminium conductor XLPE insulated armoured heavy duty cable heat shinkable suitable in/ out door type to be fix on incoming /outgoing connection of LT panel with gland etc at various location for following size :-.
All as in Item No - 07, but for 3.5 core 240 to 300 Sqmm
All as in Item No - 07, but for 3.5/4 core 150 to 185 Sqmm
All as in Item No - 07, but for 3.5/4 core 70 to 120 Sqmm
All as in Item No - 07, but for 3.5/4 core 25 to 50 Sqmm
All as in Item No - 07, but for 3.5/4 core 6 to 16 sqmm
Supply and fixing of MCCB 400 amps, 4 pole,415 Volt microprocessor based type with breaking capacity 36 KA, and 100 % Icu including spreader terminals and Suitable for Isolation Adjustable Over Load setting ,Adjustable Short Circuit setting, ,Wide Range of snap fit Internal and External Accessories including Taking down MCCB all as specified and directed by Engineer-in-charge.
All as in Item No-13, But for 250 Amps.
All as in Item No-13, But for 200 Amps.
All as in Item No-13, But for 160 Amps.
Supply and fixing of MCCB 100 amps, 4 pole,415 Volt Adjustable type with breaking capacity 16 KA, and 100 % Icu including spreader terminals and connected acessories complete as specified and directed.
All as in Item No-17, But for 63 Amps.
Supply, fixing and connecting in replacement of Manual On Load change over switch with sheet steel enclosure rating 63 Amps 4 pole, 440 volts grade in sheet metal enclouser fixing in surface of wall on wooden board with making all coonection, gland etc all as site and directed.
All as in Item No- 19, But for 100 Amps.
All as in Item No- 19, But for 200 Amps.
All as in Item No- 19, But for 400 Amps.
Supply, fixing and connecting in replacement of Manual On Load change over switch with open Execution rating 100 Amps 4 pole, 440 volts grade fixing in panel with making all coonection, gland etc all as site and directed.
All as in Item No- 23, But for 200 Amps.
All as in Item No- 23, But for 400 Amps.
Supply /laid/ fixing/ connecting and testing in replacement of the following LT under ground XLPE insulated ,armoured heavy duty electric power cable with aluminium conductor , 1100 volts grade (earthed) cross section area 300 Sqmm x 3.5 core.
All as in Item No-27 but for 240 Sqmm x 3.5 core
All as in Item No-27 but for 185 Sqmm x 3.5 core
All as in Item No-27 but for 120 Sqmm x 3.5 core
All as in Item No-27 but for 95 Sqmm x 3.5 core
All as in Item No-27 but for 50 Sqmm x 3.5 core
All as in Item No-27 but for 25 Sqmm x 4 core
Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose for laying cables, etc. complete all as specified and as directed.
Returning, filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and as directed.
Removing surplus excavated soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed..
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230 mm spreding thickness and consolidated ( punned) upto 180mm thickness, complete all as specified and as directed. Note : punned thickness will only be measured for payment purpose.
M&L for sub class 'B' brick for protection of UG cable in tranches of old size brick all as specified and directed by Engineer-in-charge.
Labour for horizontal boring of Road/path for cable passing through complete all as specified
Supply/ laid/ fixing in replacement of galvanised steel water tube, light grade bore of dia 80 mm with all fittings all as site and directed.
Supply/ laid/ fixing in replacement of galvanised steel water tube, light grade bore of dia 50 mm with all fittings all as site and directed.
M&L for jointing/ cutting/ welding/ replacing hinges etc all as site required to LT panel made out MS sheet and angle for making smoth opening and closing complete with re-painting as same macthing with exsiting surrface all as directed.
Decarbonising/ cleaning of Existing LT panel cubical type of various size consists of bus bar and circuit chamber, metering chambers CTs and relays chambers, checking the bus bar joints, bus bar and circuit spouts, cleaning and applying Busbar Insulation Tape to the bus bars , checking the current transformer, applying Monoplast compound at the bus bar joints after tightening of joints ,replaced new suiable size of lugs /suitable copper control cable and reassembling , if any rusted sheet replaced with new sheet as per existing size complete all as directed by Engineer-in-Charge. Note:- Cost of lubricant/ cleaning agents (CRC & rust remover) / hardware like springs/ bolts/ nuts/ washers,lugs/ suitable copper cables cost of labour, T&P required for replacement shall be etc. shall be deemed to be included in the rate quoted.
Material and labour for painting to LT panel of any size by scrapping and removing oil paint and applying 01 coats of synthetic enamel paint of approved colour by taking due complete all as specified and directed by Engineer-in-charge .
S & F LED indicating Lamps for R, Y, B phases complete including taking down ols U/S lamps all as specified and directed.
Supply and lying in repair of Chequred Electrical rubber mat of size 1m x 2m , 6 mm thick complete all as specified and directed by Engr-in-charge
Supply & Fix in repair capacitor gas filled heavy duty cylindrical of 1- 4 KVAR, 440V complete all as specified and directed.
All as in Item No- 51 above but for capacity 5-15 KVAR.
All as in Item No- 51 above but for capacity 20-30 KVAR.
All as in Item No- 54 above but for 12 steps.
Dismantling and opening voltage stabiliser 25 KVA to 100 KVA capacity three phase, 415 volts and replacement of old unserviceable worn out/defective parts and reassembling the same after necessary repair, cleaning servicing and testing on completion for its satisfactory performance all as specified and directed by Engineer-in-Charge. (spares required will be measured and paid separately).
Dismantling and opening voltage stabiliser 125 KVA to 250 KVA capacity three phase, 415 volts and replacement of old unserviceable worn out/defective parts and reassembling the same after necessary repair, cleaning servicing and testing on completion for its satisfactory performance all as specified and directed by Engineer-in-Charge. (spares required will be measured and paid separately).
Supply only variable/auto transformer suitable for line voltage corrector 25 KVA to 100 KVA, 415 volts, 50 Hz complete all as specified and directed.
Supply only variable/auto transformer suitable for line voltage corrector 125 KVA to 250 KVA, 415 volts, 50 Hz complete all as specified and directed.
Supply only relay suitable for line voltage corrector 25 KVA to 100 KVA, 415 volts, 50 Hz as specified and directed.
Supply only relay suitable for line voltage corrector 125 KVA to 250 KVA, 415 volts, 50 Hz as specified and directed.
Supply only Sevo Motor suitable for automatic line voltage corrector of capacity 25 KVA to 100 KVA all as specified and directed.
Supply only Sevo Motor suitable for automatic line voltage corrector of capacity 125 KVA to 250 KVA all as specified and directed.
Supply only Carbon Bush suitable for automatic line voltage corrector of capacity 25 KVA to 100 KVA all as specified and directed.
Supply only Carbon Bush suitable for automatic line voltage corrector of capacity 125 KVA to 250 KVA all as specified and directed.
Supply only servo voltage stabilizer oil complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of Test point terminal block made of gun metal or phosphorus bronze in size 75x75x25 mm drilled and screwed including 03 nos ,8 mm dai 25 mm long hex head screw complete all as specified and directed.
NOTES: 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule "A" notes for details.
PURBANCHAL BUILDERS (BID ID -3498514)
Flint India (BID ID -3505094)
M/S MECHANICAL ENGINEERING and ELECTRICAL CONTRACTORS (BID ID -3498285)
M/s.Sai Agency (BID ID -3493226)
D G Corporation (BID ID -3502572)
AVASANA SOLUTIONS PRIVATE LIMITED (BID ID -3498166)
M/S N S CONSTRUCTION (BID ID -3496271)
Chinmay Traders (BID ID -3505107)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
91tenderdocus.pdf
Tender Documents • 1.42 MB
Makes.rar
Additional Documents • 0.04 MB
BOQ_828874.xls
BOQ • 1.17 MB
Download all tender documents and submit your bid