Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 2ND FLOOR COMMERCE CENTRE KULUR KAVOOR ROAD KULUR MANGALORE D K 575 013 | DAKSHINA KANNADA | KARNATAKA | 575013 | Admitted-Finance |
| 4 | Admitted-Finance 3 23 24 1 ORCHID LAYOUT ABHEESHTA MALEMAR ROAD ASHOKNAGAR KOTTARA CHWOKI MANGALORE DAKSHINA KANNADA KARNATAKA 575006 | DAKSHINA KANNADA | KARNATAKA | 575006 | Admitted-Finance |
| 5 | Admitted-Finance SHED NO 11 DSIIDC COMPLEX WAZIRPUR INDUSTRIAL AREA DELHI NEW DELHI PIN 110052 | NEW DELHI | NEW DELHI | DELHI | 110052 | Admitted-Finance |
Tender Value
₹31.2 L
EMD Value
₹73,700
Closing Date
14 Mar 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer(E)II
Electrical division, Admin Building 2nd floor, NMPA, Panambur, Mangaluru
Providing electrification to KK Gate at Wharf
2024_NMPT_796875_1
13/KK Gate/EE(E)II/2024 dtd.22.02.2024
Open Tender
Electrical Works
Works
90 days
NMPA Panambur, Mangaluru
Please refer Tender documents.
2 documents required · 2 mandatory
₹560
Yes
FA and CAO NMPA
₹73,700
Yes
24 May 2024
22 Feb 2024
15 Mar 2024
22 Feb 2024
14 Mar 2024
23 Feb 2024
Supply, installation, testing and commissioning of Outdoor type metering panel, including supply and accommodating CT operated TOD meter and 100A FP,25kA MCCB with earth fault release in separate chamber, Inter connections etc. as required and necessary supports to be fabricated out of 14 SWG CRCA sheet with lockable door with scaling facility having glass window for energy meter top canopy weather proof enclosure(IP-54) and necessary overhang, undergone seven tank process powder coated finish and all mounting accessories as required the panel shall be with all accessories as per drawing & specification
Supply, Installation, Testing and Commissioning of 5 KVA, single phase input, single phase output, true on-line UPS system with 30 minutes back up, output isolation transformer including all accessories .SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc. as require complete having following specification. The Ups system consist of one number of UPS unit and one set of battery bank fully digital controlled based on DSP power factor from end 0.9. Pure sine wave output voltage & frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display static bypass switch/ manual by pass switch Auto temperature compensation
Supply, Installation, Testing and Commissioning of 3 KVA, single phase input single phase output, true on-line UPS system with 30 minutes back up, output isolation transformer including all accessories. SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc. as require complete having following specification. The Ups system consist of one number of UPS unit and one set of battery bank fully digital controlled based on DSP power factor from end 0.9. Pure sine wave output voltage & frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display static bypass switch/ manual by pass switch Auto temperature compensation
Supply of 3.5C x 185 Sq.mm size1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date
Supply of 3.5C x 70 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended up to date.
Supply of 4C x 16 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supply of 4C x 4 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming 186to IS 7098 (Part 1) amended upto date.
Supply of 2C x 4 sqmm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5C x 185 Sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
Supplying and making end termination with brass compression gland and aluminium lugs for following 3.5C x 70 Sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following 4C x 16 Sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
Supplying and making end termination with brass compression gland and copper lugs for following 4C x 4 Sq.mm size of PVC insulated and PVC sheathed/ XLPE copper conductor cable of 1.1 KV grade as required.
Supplying and making end termination with brass compression gland and copper lugs for following 2C x 4 sq.mm size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following upto 35 sq. mm (clamped with 1mm thick saddle) size on wall or surface as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following Above 35 sq. mm and upto 95 sq. mm (clamped with 1mm thick saddle) size on wall or surface as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following Above 95 sq. mm and upto 185 sq. mm (clamped with 1mm thick saddle) size on wall or surface as required.
Laying of one number PVC insulated and PVC sheathed armoured power cable of 1.1KV grade for the following upto 35sq mm size in ground including excavation, sand cushioning providing protective covering and refilling the trench etc. As required
Laying of one number PVC insulated and PVC sheathed armoured power cable of 1.1KV grade for the following Above 35 sq mm and upto 95mm size in ground including excavation, sand cushioning providing protective covering and refilling the trench etc., as required
Laying of one number PVC insulated and PVC sheathed armoured power cable of 1.1KV grade for the following Above 95sq mm and upto 185sq mm sizes in ground including excavation, sand cushioning providing protective covering and refilling the trench etc., as required
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following 35sq mm size direct in ground in the same trench in tier horizontal formation including excavation, sand cushioning providing protective covering and refilling the trench etc., as required
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following upto 35 sq. mm size in the existing RCC/ HUME/ METAL pipe as required
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following above 35 sq. mm and up to 95 sq. mm size in the existing RCC/ HUME/ METAL pipe as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following above 95 sq mm size and up to 185 sq mm size in the existing RCC/ HUME/ METAL pipe as required.
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following Up to 35sq.mm (clamped with 1mm thick saddle) size on cable tray as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following above 35 sq. mm and upto 95 sq. mm (clamped with 1mm thick saddle) size on cable tray as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following above 95 sq. mm and up to 185 sq. mm (clamped with 1mm thick saddle) size on cable tray as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following Above 35 sq. mm size in the existing masonry open duct as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following Above 35 sq. mm and up to 95 sq. mm size in the existing masonry open duct as required
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following above 95 sq. mm and up to 185 sq. mm size in the existing masonry open duct as required.
Providing, laying and fixing following 50 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required
Providing, laying and fixing following 100 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required
Fabrication, supply and installation of following 150 MM WIDTH X 50 MM DEPTH X 2MM THICK size of perforated G I cable tray including horizontal and vertical reducer’s tees, cross members and other accessories as required and duly suspended from ceiling with MS suspenders and painting etc. required.
Providing, laying and fixing following 100 mm dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 Cement : 2 fine Sand) including trenching (75 cm deep) and refilling etc., as required
Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required
Supply of ISI marked HDPE pipes with following 110 mm dia (OD) size of 10 kg/cm2 conforming to as per IS4984,1985 PE-100 including all fittings and specials such as tees, elbows, bends reducers, end caps complete so as to withstand the internal design pressure of 10kg/cm2 as directed by engineer – in-charge
Providing and laying 450 mm dia RCC pipe Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/s pigot jointed with stiff mixture of cement mortar in the proportion of 1:2 including testing of joint of joints etc. complete
Supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick G.I. plate with inscription there on, bolted/welded to 35mm x 35mm x 6mm angle iron, 60 cm long and fixing the same in ground as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch modular plate suitable GI box and earthing the point with 1.5sq mm FRLSPVC insulated copper conductor single core cable etc., as required (NOTE: the total distance from the switch box to the point will not exceed 5mtr, incase if length increase above 5 meters the wiring shall be measured under items 41)
Group controlled light point with 1.5 sq. mm wire - Wiring for Group controlled light point (from one point to another point) with 3x1.5 sq mm PVC insulated (FRLS) copper conductors cable in surface / recessed mounted rigid medium class 20mm PVC conduit with all accessories as required (NOTE: this item does not include the cost of MCB or 16Amp/6Amps one way switches the total distance from one point to another point will not exceed 5 meters. Incase if the total length increase, the additional length shall be measured under items 41 the distance from DB to 1st point will be measured under point circuit wiring.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, 2way modular switch modular plate suitable GI BOX AND EARTHING THE POINT WITH 1.5 SQ MM FRLS PVC insulated copper conductors single core cable etc. as required (NOTE: the total distance from switch box to the point will not exceed 5 mtrs incase if length increases above 5 meters, the wiring shall be measured under items 41
Circuit wiring - Wiring for circuit/ submain wiring along with earth wire with the following 2 x 1.5 sq. mm + 1 x 1.5 sq.mm earth wire sizes of FRLS PVC insulated copper conductors single core cable in surface/ recessed medium class PVC conduit as required
Circuit wiring - Wiring for circuit/ sub main wiring along with earth wire with the following 2 x 2.5 sq. mm + 1 x 2.5 sq.mm earth wire sizes of FRLS PVC insulated copper conductors single core cable in surface / recessed medium class PVC conduit as required
Circuit wiring - Wiring for circuit/sub main wiring along with earth wire with the following 2 x 4 sq. mm + 1 x 4 sq.mm earth wire sizes of FRLS PVC insulated copper conductors single core cable in surface / recessed medium class PVC conduit as required
Circuit wiring - Wiring for circuit / sub main wiring along with earth wire with the following 2 x 1.5 sq. mm + 1 x 1.5 sq.mm
Circuit wiring -Wiring for circuit / sub main wiring along with earth wire with the following 2 x 2.5 sq. mm + 1 x 2.5 sq.mm earth wire sizes of FRLS PVC insulated copper conductors single core cable in surface / recessed medium class PVC conduit as required
Supplying and fixing following 6 pin 15/16 amp socket outlet with modular plate & cover on surface or in recess, including providing and fixing suitable size GI box, inter connection etc. as required complete.
Supplying and fixing following 15/16 amp switch with modular plate & cover on surface or in recess, including providing and fixing suitable size GI box, inter connection etc. as required complete.
Supplying and fixing following Telephone socket outlet with modular plate & cover on surface or in recess, including providing and fixing suitable size GI box, inter connection etc. as required complete.
Supplying and fixing following Bell push with modular plate & cover on surface or in recess, including providing and fixing suitable size GI box, inter connection etc. as required complete.
Supplying and fixing call bell / buzzer suitable for single phase, 230 volts, complete as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6pin 5/6 & 15/16 amps modular switch connection etc. as required
Supply & fixing Computer points with 3 Nos 3 pin 5/6A socket with 2No. 5/6A switch with modular front plate and cover surface/recess including providing and fixing suitable size GI boxes, its interconnections etc. as required complete. (NOTE: 2 Nos 5/6A sockets fixed at 60cm above with 1 No 5/6 A sockets at 1m above FFL)
Supply, fixing of Network point, UTP RJ45, CAT 6 modular type socket with modular plate & cover on surface or in recess, including proving and fixing suitable size GI box, inter connection etc. as required complete.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing of following 20 mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following 25mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following 32 mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps “C” curve SP. MCB, in sheet steel enclosure on surface or in recess with chained metal cover for socket out let and complete with connection testing and commissioning etc. as required
Supplying and fixing of following 20 mm sizes of medium class PVC conduit along with accessories in surface/recess making chases in wall including making good by applying Renderoc S2 as per manufacturers specification and finishing with putty, 1 coat primer and 2 coats acrylic emulsion paint to match the surface
Supplying and fixing of following 25 mm sizes of medium class PVC conduit along with accessories in surface / recess making chases in wall including making good by applying Renderoc S2 as per manufacturers specification and finishing with putty, 1 coat primer and 2 coats acrylic emulsion paint to match the surface
Dismantling of following medium class PVC conduit along with wiring accessories in surface making good by applying Renderoc S2 as per manufacturers specification and finishing with putty, 1 coat primer and 2 coats acrylic emulsion paint to match the surface
Supplying and fixing following 6 way (4+18), Double door surface / recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel dust protected, duly powder painted inclusive of 200 amps tinned copper bus bar, common neutral link earth bar din bar for mounting MCBs with provision of 100/125Amps FP 16 KA MCCB as incomer interconnection between incomer MCCB and bus bars (but without MCB’s/ MCCB) as required. (NOTE: vertical type MCB TPDB is normally used where 3 phase outlets are required)
Supplying and fixing following 8 way (8+18), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volt, on surface/ recess, complete with tinned copper bus bar, common neutral link earth bar din bar powder painted including earthing etc. as required (but without MCB/ RCCB/isolator)
Supplying and fixing following 16way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volt, on surface/recess, complete with tinned copper bus bar, common neutral link earth bar din bar powder painted including earthing etc. as required (but without MCB/RCCB/isolator)
Supply and fixing of following 2 pole 25 amps. (415 Volts), 30mA sensitivity. Rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required
Supply and fixing of following 4 pole 40 amps, (415 Volts), 30mA sensitivity rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required
Supply and fixing of 6A to 32A, SP, B/C- CURVE following rating, 10 KA, Miniature Circuit Breakers as required.
Supply and fixing of 6A to 32A, TP, B/C- CURVE following rating, 10 KA, Miniature Circuit Breakers as required.
Supply and fixing of 6A to 32A, SP, D - CURVE following rating, 10 KA, Miniature Circuit Breakers as required.
Supply and fixing of 40A to 63A, TP, B/C- CURVE following rating, 10 KA, Miniature Circuit Breakers as required.
Supply, Installation, Testing & Commissioning of 25A DP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc. as required complete.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Providing and fixing following 100 Amp, MCCB rating and 25 kA breaking capacity and FP pole MCCB in existing distribution board, making connections, etc. as required
Supply, installation, testing and commissioning of DOL starter upto 3HP, 1p motors including axillary contactors, push buttons and all necessary accessories as required complete. The starter enclose shall be made of powder coated 1.6mm CRCA sheet
Supply of indoor decorative surface mounted LED Batten with Polycarbonate diffuser along with driver, system wattage of maximum 20 watts lumens output of luminaire greater than 2000, power factor > 0.9, rated life of L70 @ 25000 hours, system efficacy > 100 lumens/watt and including all the necessary accessories as required complete
Supply of LED recess mounted down light made of die cast aluminium, along with driver, system maximum wattage of maximum 12 watts with lumens output of luminaire greater than 1200, power factor > 0.95, THD<10%, rated life of L70 @ 50000 hours, system efficacy > 100 lumens/watt and including all the necessary accessories as required complete
Supply of LED surface mounted down light made of die cast aluminium, along with driver, system maximum wattage of 12 Watts with lumen output of luminaire greater than or equal to 1200 lumens, power factor > 0.95, THD<10%, rated life of L70 @ 50000 hours, system efficacy > 100 lumens per watt and including all the necessary accessories as required complete
Supply of LED recess mounted down light made of die cast aluminium, along with driver, system maximum wattage of 15Watts with lumen output of luminaire greater than or equal to 1500 lumens, power factor > 0.95, THD<10%, rated life of L70 @ 50000 hours, system efficacy > 90 lumens per watt and including all the necessary accessories as required complete
Supply of LED surface mounted down light made of die cast aluminium, along with driver, system maximum wattage of 15Watts with lumen output of luminaire greater than or equal to 1500 lumens, power factor > 0.95, THD < 10%, rated life of L70 @ 50000 hours, system efficacy > 90 lumens per watt and including all the necessary accessories as required complete
Supply of recess mounted LED panel light fixture light made of die cast aluminium with corrosion resistance powder coating and with proper diffusers along with driver, system wattage of 36 watts with lumen output of fixture > or = to 3600 lumens, power factor > 0.95, THD<10%, rated life of L70 @50000 hours, system efficacy > 100 lumens per watt and including all the necessary accessories as required complete
Supply of surface mounted LED panel light fixture light made of die cast aluminium with corrosion resistance powder coating and with proper diffusers along with driver, system wattage of 36 watts with lumen output of fixture > or = to 3600 lumens, power factor > 0.95, THD < 10%, rated life of L70 @ 50000 hours, system efficacy > 100 lumens/watt and including all the necessary accessories as required complete
Supply of LED high bay Lighting luminaire of, pressure die cast aluminium housing body with optimal heat sink, with system wattage of maximum 80 W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens greater than 8800 and system efficacy > or = 95%
Supply of LED high bay Lighting luminaire of, pressure die cast aluminium housing body with optimal heat sink, with system wattage of maximum 200 W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens greater than 22000 and system efficacy > or = 95%
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less direct current (BLDC) motor, class of insulation: B, 3 Nos blades 30cm long down rod 2nos canopies, shackle kit safety rope, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 6.85, air delivery minimum 215 CMM 350 RPM (tolerance as per IS : 374-2019), THD < 10% remote or electronic regulator unit for speed controller and all remaining accessories including safety pin, nut bolts washers temperature rise = 75 degree C (max) insulation resistance more than 2 M ohm suitable for 230 volt 50 hz single phase AC supply, earthing etc. complete as required
Supply of 250 mm sweep, 900 rpm light duty exhaust fan in plastic body with self-opening louvers working on 230 V AC supply complete with all accessories as required
Supply of 10W LED Bulkhead fitting with die cast aluminium housing, PC diffuser and IP66 Protection suitable for operation on 230 Volt 50 Hz AC WALL / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire and making good the surface as required
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/LED Fitting of all types, complete with all accessories and tube etc., directly on ceiling /wall including connections with 1.5 sq mm FRLS PVC insulated copper conductor single core cable and earthing etc., as required
Installation, testing and commissioning of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing & commissioning etc. as required
Installation, testing and commissioning of High bay/Mid bay/LED/ FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps / nuts bolts/20mm heavy duty GI chain/pipe (upto 50cm) etc., including connection with 3C x 2.5 sq mm pvc insulated flexible copper conductors as required
Installation, testing and commissioning of LED down lighter fittings on false ceiling with all mounting accessories as required complete including interconnections using 3 core 1.5sqmm FRLS PVC insulated flexible copper conductor as required.
Installation, testing and commissioning of LED PANEL type fittings with GI chain and 2x2 adapter - with all accessories etc., on false ceiling including supplying and fixing of GI chain and 2x2 adaptor hook arrangement, up to 60cm length, wiring 3 runs of 1.5sq mm FRLS PVC insulated stranded copper conductor cable as required.
Supply, installation and testing of IP65 LED UP DOWN luminaire made with die cast aluminium body with mounting bracket, the item includes LED module along with driver of approved make each with maximum system wattage of 6+/-2 watt system efficacy shall be greater than 90 Lm/W, power factor > 0.9 of L70 @ 50000 hours, CCT 3000 K, with CRI >= 80, beam angle 45 +/ -2 degree pre wired with all the necessary accessories and interconnection as required.
Numbering of ceiling fan / exhaust fan/ fluorescent fitting as required.
Earthing with G.I. earth pipe 3 meter long, 100 mm dia including accessories, and providing masonry enclosure with heavy duty GI cover plate of 300x300 mm having locking arrangement and watering pipe etc. with 64kg charcoal /coke and 5kg salt as required. (As per IS : 3043 amended up to date)
Providing and fixing 25mm x 6mm GI strip on surface or in recess for connections etc., as required.
Providing and fixing 3.15mm Cu (10 SWG) wire on surface or in recess for connections etc., as required.
Supplying and laying 25mm x 6mm GI strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I nut bolt, spring washer etc. as required. Jointing shall be done by over lapping 2 sets of G.I nut bolt spring washer spaced at 50mm)
Supplying and laying 3.15mm Cu (10 SWG) wire at 0.50 meter below ground as strip earth electrode, including connection / terminating with G.I nut bolt, spring washer etc. as required. Jointing shall be done by overlapping 2 sets of G.I nut bolt spring washer spaced at 50mm)
Supply and fixing of 8mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace with the required mounting clamps, cross connectors, expansion piece and other accessories required as per IEC 62305-3
Supply and fixing of 8mm Aluminum Round Conductor as down conductor with the required mounting clamps, cross connectors, expansion piece and other accessories required as per IEC 62305-3
Providing and Fixing of Test Joint, suitable to fix 8mm Aluminium conductor to 32 x 6 GI strip
Providing and laying GI tape 32mm x 6mm thick from earth electrode directly in ground as required
Supply, Fixing, Testing and commissioning of following 25 mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Providing, laying and fixing following 50 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75cm deep) and re-filling etc., as required
Supply, Fixing, Testing and commissioning of following 25 mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Providing, laying and fixing following 50 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75cm deep) and re-filling etc., as required
GK Electricals
M/s Anugraha power services
M/s. Precision Electrical Works
SRS ELECTRICALS
OLIVE EXPORTS PVT.LTD.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .