Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC | L1 | Accepted-AOC Accepted - Being L1 bid | |
| 2 | L2₹21.6 L+₹2,486 (0.12%)Rejected-AOC | L2 | Rejected-AOC Rejected - Being higher than L1 bid | |
| 3 | L3₹21.6 L+₹8,423 (0.39%)Rejected-AOC | L3 | Rejected-AOC Rejected - Being higher than L1 bid | |
| 4 | L4₹21.9 L+₹34,924 (1.62%)Rejected-AOC | L4 | Rejected-AOC Rejected - Being higher than L1 bid | |
| 5 | L5₹22.0 L+₹43,461 (2.02%)Rejected-AOC | L5 | Rejected-AOC Rejected - Being higher than L1 bid |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
21 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SILCHAR
GE SILCHAR, MASIMPUR, ASSAM 788025
REPAIRS/MAINTENANCE OF LT DISTRIBUTION SYSTEM AT MASIMPUR MILITARY STATION UNDER GE SILCHARCONTENTS
2021_MES_447223_1
8627/E8
Open Tender
Civil Works
Item Rate
180 days
MASIMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹40,000
Yes
3 Jul 2021
31 May 2021
22 Jun 2021
31 May 2021
21 Jun 2021
17 Jun 2021
60 days
Amount
Dismantling of old unserviceable/damaged ACSR or AAC conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material sepereately complete all as specified and directed.
Dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of PCC and removing unserviceable meterials from site of work complete all as specified and directed.
Dismantling old unservicable RCC/steel poles/struts of any size including breaking up PCC foundation complete all as specified and directed.
Dismantling of corroded/rusted/defective cross-arms of MS channel or angle of any sections complete all as specified and directed.
Dismantling of unserviceable insulators of any size/type complete all as specified and directed.
Dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5 mtr and not exceeding 3 mtr in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed.
Supply and spread sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. Note : Thickness of sand cushion after punning down will be measured and paid.
Material and labour for laying of bricks locally available sub-class 'B' brick (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the directon of cable complete all as specified and directed.
Material and labour for steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP- 31 (9m long)confirming to IS-2713 (Part I & II) incl painting of pole with two coats of aluminium paint over a coat of red oxide zink chrome primer from top of the pole to 1.5m above the bottom of the pole and painting with two coats of black bituminous paint over a coat of red oxide zink chrome primer upto 1.5m from bottom of the pole incl. PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate incl numbering of poles as directed complete all as specified and directed. Note : Excavation and earth work and PCC shall be measured and paid separately under respective items.
Material and labour for providing plain cement concrete 1:3:6 type C1 using 20 mm graded crushed stone aggregates as in coping including all necessary form work complete all as specified.
Material and labour for loop type insulator, vitreous porcelain, white, brown or green, small size with overall dimension 90 x 140mm clearance of hole 25.5mmcomplete all as specified and directed.
Material and labour for stay assembly complted with all accessories as shown in electrical plate No 1 of SSR 2009 Part I (Loop type insulator, stay clamps, stay strand, excavation and conerete shall be measured separately) using 16 mm dia stay rod incl PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate complete all as specified and directed.
Material and labour for cross arm bracings,supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primercomplete all as specified and directed.
Refixing only for cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including new nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and directed. Note : Old servicable material reteieved from siteshall be reused under this item.
Supply and fix pin type insulator porcelain vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 100 mm height, 65 mm dia for 1100 volts grade complete complete all as specified and directed.
Supply and fix shackle type porcelain vitreous white, brown or green insulator of size 75 mm height 90 mm dia including MS strips 31x3 mm washers, insulator bolts 12 mm dia & nuts suitable for working pressure 1100 volts grade complete all as specified and directed.
Fixing only insulator any type and any shape (except disc type insulator)complete all as specified and directed. Note: Old servicable material obtained from Serial Item No 4 shall be reused under this item.
Material and labour for cradle guard, hexagonal/rectangular or as per existng shape fabricated with galvanised steel wire 4 mm dia including binding the guards with cradle supporting GI wire and setting asidecomplete all as specified and directed.
Material and labour for galvanised stay strand of size 7/4mm including securing with LT pole clamp and stay clampcomplete all as specified and directed.
Taking out existing old damaged / unserviceable LT UG cable, PVC/XLPE insulated, steel strip /wire armoured multistranded aluminium conductor cable from trench /duct /pipe. etc of any sizes complete all as specified.
Supply, laying connecting testing only XLPE/PVC sheathed, armoured LT electric power UG Cable (Heavy duty) with stranded aluminium conductor of size 240 Sqmm, 3.5 core 1100 volts grade, laid through duct/pipe/in trench etc. incl cable gland and lugs complete all as specified and directed.
Supply, laying connecting testing only XLPE/PVC sheathed, armoured LT electric power UG Cable (Heavy duty) with stranded aluminium conductor of size 185 Sqmm, 3.5 core 1100 volts grade, laid through duct/pipe/in trench etc. incl cable gland and lugs complete all as specified and directed.
Supply, laying connecting testing only XLPE/PVC sheathed, armoured LT electric power UG Cable (Heavy duty) with stranded aluminium conductor of size 95 Sqmm, 3.5 core 1100 volts grade, laid through duct/pipe/in trench etc. incl cable gland and lugs complete all as specified and directed.
Supply, laying connecting testing only XLPE/PVC sheathed, armoured LT electric power UG Cable (Heavy duty) with stranded aluminium conductor of size 70 Sqmm, 3.5 core 1100 volts grade, laid through duct/pipe/in trench etc. incl cable gland and lugs complete all as specified and directed.
Supply, laying connecting testing only XLPE/PVC sheathed, armoured LT electric power UG Cable (Heavy duty) with stranded aluminium conductor of size 16 Sqmm, 4ore 1100 volts grade, laid through duct/pipe/in trench etc. incl cable gland and lugs complete all as specified and directed.
Supply, laying connecting testing only XLPE/PVC sheathed, armoured LT electric power UG Cable (Heavy duty) with stranded aluminium conductor of size 16 Sqmm, 2 core 1100 volts grade, laid through duct/pipe/in trench etc. incl cable gland and lugs complete all as specified and directed.
Supply and laying 80 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under road, on wall or on pole with and including clamps, nuts, bolts etc including taking down old unserviceable GI tubing of any size including cutting, chases to wall/floor & making good complete all as specified and directed.
Supply and laying 50 mm bore galvanised iron tubing, light grade with all fittings for passing of cables under road, on wall or on pole with and including clamps, nuts, bolts etc including taking down old unserviceable GI tubing of any size including cutting, chases to wall/floor & making good complete all as specified and directed.
M&L for aluminum conductor steel reinforced (ACSR) conductor, as in overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia complete all as specificed and directed.
Labour only for restringing, tightening of loose/broken ACSR conductor of any size and type for 3 phase 4 wire system, maintaining standard sag including biding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia on LT over head lines complete all as specified and directed. Note :- (a) T&P required shall be arranged by the contractor. (b) Each conductor shall be measured separately.
Material and labour for straight through joints (epoxy) including joint kits and labour complete for making joints suitable for UG cables of the size 70 sqmm 3.5 core complete all as specified and directed.
Material and labour for straight through joints (epoxy) including joint kits and labour complete for making joints suitable for UG cables of the size 16 sqmm 4 core complete all as specified and directed.
Material and labour for outdoor cable end joint any type suitable for UG cable upto 240 sqmm 3.5 core and complete all as specified and directed.
Supply and fix MCCB 4 Pole, 415V, adjustable type,Ics=100% Icu (d-sine) 630 Amps with breaking capacity 50KA, thermal release range 200-250 amp conforming to IS/IEC 60947-2 & IEC 60947-2 including taking down of existing one of any description complete all as specified and directed. Make: Cat Part No.CM94106OOT10G of L&T or equivalent make of Legrand/Siemens/ABB.
Supply and fix MCCB 4 Pole, 415V, adjustable type,Ics=100% Icu (d-sine) 400 Amps with breaking capacity 36KA, thermal release range 200-250 amp conforming to IS/IEC 60947-2 & IEC 60947-2 including taking down of existing one of any description complete all as specified and directed. Make: Cat Part No.CM98403OOR00G of L&T or equivalent make of Legrand/Siemens/ABB.
Supply and fix MCCB 4 Pole, 415V, adjustable type,Ics=100% Icu (d-sine) 250 Amps with breaking capacity 36KA, thermal release range 200-250 amp conforming to IS/IEC 60947-2 & IEC 60947-2 including taking down of existing one of any description complete all as specified and directed.Make: Cat Part No.CM92109OOP10G of L&T or equivalent make of Legrand/Siemens/ABB.
Supply and fix MCCB 3 Pole, 415V, adjustable type,Ics=100% Icu (d-sine) 200 Amps with breaking capacity 36KA, thermal release range 200-250 amp conforming to IS/IEC 60947-2 & IEC 60947-2 including taking down of existing one of any description complete all as specified and directed. Make: Cat Part No.CM92009OON10G of L&T or equivalent make of Legrand/Siemens/ABB.
Supply and fix MCCB 3 Pole, 415V, adjustable type,Ics=100% Icu (d-sine) 160 Amps with breaking capacity 36KA, thermal release range 200-250 amp conforming to IS/IEC 60947-2 & IEC 60947-2 including taking down of existing one of any description complete all as specified and directed. Make: Cat Part No.CM92008OOM10G of L&T or equivalent make of Legrand/Siemens/ABB.
Relaying of existing LT cable in trenches all as specified and directed including cable lugs, cable glands etc complete all as specified and directed. Note:- Earth work, bricks, sand filling etc shall be measured and paid separately.
M&L for Boring hole under-neath road/hardstanding/pavement with trenchless technology using mechanical drilling/horizontal boring machine for crossing of cable without cutting the surface and providing 80mm bore HDPE pipe suitable for 0.4mpa working pressure and making good the disturbed area etc complete all as specified and directed. Note : 80mm bore HDPE pipe is deemed included in unit rate quoted by the contactor.
Material and labour PCC 1:2:4 type B2 using 40mm graded crushed stone aggregrate with 100mm thick for flooring finished even & smooth complete all as specified and directed.
APFC panel throughly checked for proper functioning of all accessories bulit in and unserviceable spare/accessories to be replaced and making serviceable of APFC panel up to desired level all as specified. The following unserviceable spare are to be replaced :-
Supply and fix including taking out unserviceable MCCB rotary handle for 100 Amp MCCB.
Supply and fix including taking out unserviceable relay of APFC panel relay 3-CT sensing, 8 stage. Make: Cat Part No.CS910500000 of L&T or equivalent make of Legrand/Siemens/ABB.
Supply and fix including taking out of CT coil 10 VA, Class - 400/5A.
Supply and fix including taking out of toggle switch for individual auto/manual, 6 Amps.
Supply and fix including taking out of capacitor duty contactor for 16 KVAR.
Supply and fix including taking out of capacitor duty contactor for 6 KVAR.
Supply and fix including taking out of copper wire flexible single core, 6sqmm.
Supply and fix including taking out of copper ring terminals, 1.5 sqmm.
Supply and fix including taking out of copper wire flexible single core, 1.5 sqmm.
Labour charges for repairing of complete panel disconnection old unserviceable spare, fixing new spare, cable connection etc including complete testing
Material and labour for Phase separator for OH LT line 4 wire system complete all as specified and directed.
Material and labour for Phase separator for OH LT line 3 wire system complete all as specified and directed.
Material and labour for Phase separator for OH LT line 2 wire system complete all as specified and directed.
Supply only of 40 mm to 80 mm graded crushed stone aggreagates complete all as specified and directed.
Material and labour for trimming, cutting of various sizes of tree branches which are touching to LT over head line at various places and clear the LT over head line upto 3 mtr from conductor to tree along pole to pole all as specified and directed. Note :- (a) All the safety equipments, cutting materials, ladder etc required for the above job shall be arrange by the contractor. (b) RM is measured as effected RM of over head line. (c) The cutting shall be done two times during the contact period & length in RM as one time shall be measured & paid for .
Material and labour for cable route indicator , made out of 900 x 300 x 100 mm block in PCC 1:2:4 type B-2 duly rendering with 15 mm thick in CM 1:4 finished even & smooth duly showing size of cable complete all as specified and directed.
P K ELECTRICAL
M/S TAPAN KUMAR RAY
SAYED ALI AND SONS
SURANA CORPORATION
M/S BIJOYA LAXMI ENTERPRISE
APPLE CONSTRUCTION
M/S P K ROY AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .