| 1 | L1₹28.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder. | |
| 2 | L2₹35.9 L+₹6.7 L (23.1%)Rejected-AOC VILL BHAJNAI POST RAJPUR KALA TEHSIL ANOLA DISTT BAREILLY UP 243302 | BAREILLY | BAREILLY | UTTAR PRADESH | 243302 | L2 | Rejected-AOC Being other than lowest bidder. | |
| 3 | L3₹44.8 L+₹15.7 L (53.8%)Rejected-AOC C 247 1 RAJINDRA NAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L3 | Rejected-AOC Being other than lowest bidder. |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Mar 2025, 6:00 pmClosed
GE EAST BAREILLY
GARRISSION ENGINEER EAST, SHAHJAHANPUR ROAD BAREILLY
COMPREHENSIVE REPAIR AND MAINT TO SANITARY FITTING, PLUMBING WORKS, ROOF/SUNKEN TREATMENT, PCC FLOORING, BRICK WORK, PLASTERING WORK, JOINERY AND TILLING OF OFFRS JCOS AND OR MD ACCN AT BAREILLY STATION UNDER GE EAST BAREILLY
2025_MES_695585_1
8390/E8
Open Tender
Civil Works
Item Rate
245 days
GE EAST BAREILLY
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE EAST BAREILLY
₹90,000
Yes
24 Mar 2025
30 Jan 2025
6 Mar 2025
30 Jan 2025
4 Mar 2025
13 Feb 2025
Amount
Taking up or down GI tubing and connections of 15mm bore including cleaning for refixing Complete all as specified and directed by Engineer-in-charge.
All as per item No.2 above but 20 mm bore.
S& F in repair for 20 mm dia CPVC pipe as on wall , floor , ceiling , concealed etc complete and as directed by Engr in charge with all fittings and fixtured , jonting solution of ISI mark including making grove in wall/ceiling and finished with cement mortor 1:4 with plumbing nails for securing pipes etc directed.
S& F in repair for 25 mm dia CPVC pipe as on wall , floor , ceiling , concealed etc complete and as directed by Engr in charge with all fittings and fixtured , jonting solution of ISI mark including making grove in wall/ceiling and finished with cement mortor 1:4 with plumbing nails for securing pipes etc directed
Supply and fixing in repairs 15 mm bore float valve of high pressure PTMT with epoxy coated aluminuim rod and high density plastic ball screwed for iron pipe and fixed in tank which situated up to 16m height buildingincluding necessary ladder for climbing and including replacement of GI Nipples and other fittings if required .complete all as specified and as directed by Engineer-in-Charge.
All as per item No.05 above but 20 mm bore complete all as specified.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing the rubbish. Complete all as specified and as directed by Engineer-In-Charge
M & L for 75mm thick Cement Concrete type D2 (1:4:8) using 40 mm graded stone aggregate as in sub base of floor as directed by Engineer-In-Charge
M & L for 25 mm thick Cement Concrete type B 1 (1:2:4) using 20 mm graded stone aggregate as in sub bases, sub floors . Complete all as specified and as directed by Engineer-In-Charge
M&L for repairs to sunken floor slab with the following specifications:- (a) Demolition of PCC and taking out old brick bat fillihng and roughening surfaces of old concrete floor and wall by picking, sweeping clean and washing down with water to remove dust etc. (b) PCC 1:2:4,type B-0, using 12.5mm graded stone aggregate averaging 50mm thick as in sunken floor,with proper slope towards GI spout. The dia of GI Spuot pipe shall be 50mm Medium grade. The minimum length of Spout shall be 500mm and if any spout comes above chajja than the length of the spout shall be more than Chajja projection. Ends of Spout shall be tippered and any cutting through brick/ RCC structure shall be done by the Contractor rates are deemed to be included of this aspects. (c) providing 15mm thick cement plaster in cement mortar 1:3 mixed with water proofing compound @ 3% by weight of cement over bottom and vertical surfaces finishing the surface even and smooth with using extra cement. (d) Damp proof course on horizontal / Vertical surfaces with preparation & applying one coat of primer (33% dilution) and two coats of undiluted material @ 10.67 lts per 10 sqm of Make : smart care Damp proof of M/s asian paint or equivelent for water proofing compound. (e) Graded Brick bats filling under sunken floor of required thickness as per site. (f) PCC 1:3:6,type C-1,using 20mm graded stone aggregate 75mm thick, over brick bats filling as in subbase. Note:- (i) For payment purpose only plan floor area shall be measured. (ii) After Coating of Water proofing compound ponding test shall be carried out by filling the sunken surface with water for 72 Hrs and get approved by Engr-in-Charge if any leakage/ seepage noticed the Contractor will re do the whole process without any extra payment.
M & L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tileexceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. laid over 15 mm thick screed bed of cement mortar 1;6 set and jointed in neat cement slurry and pointed in white or coloured cement to match.Complete all as specified and as directed by Engineer-In-Charge..
M & L for coloured glazed ceramic tiles (300 mm x450 mm/300mmx600mm) & 7 mm thick on vertical surfaces such as skirting, dados etc, set and jointed in neat cement slurry over and including 10 mm thick bedding layer/ backing coat in CM 1:4 complete and pointed in white or coloured cement to match complete all as specified and as directed by Engineer-In-Charge.
S&F in repairs 10 litres capacity PVC Valveless symphonic action type flushing cistern high / low level white complete with inlet , ball valve float and handle including brackets and telescopic down pipes and jointing with WC complete complete all as specified and as directed by Engineer-In-Charge
S & F in Repair Pillar taps , cast copper alloy , with capstan heads, chromium plated, screwed down high pressure fancy type of 15 mm bore size with or without lettered Hot or Cold with long screwed shanks and flynuts , screwed for iron pipe and fixed Complete all as specified and as directed by Engineer-In-Charge.
S&F in Repair Cast copper alloy CP angle valve type stop cock suitable for 15mm bore pipe screwed at both ends or high pressure with Capstan head . Including dismanteling and making good the tiles if required of make Prayag/Marc/Seiko,Complete all as specified and as directed by Engineer-In-Charge.
S&F in Repair bib taps of bore size 15mm, cast copper alloy, , chromium plated, fancy type, with crutch or butter fly handle screwed down , screwed for iron pipe or for brass ferrule Including dismanteling and making good the tiles if requiredComplete all as specified and as directed by Engineer-In-Charge.
S & F in Repair brass cromium plated conceled stop cock of bore size 15 mm, in position conceled in walls/ceilings or floors complete duly making grooves filled with cement mortar in 1:4 finished to match with adjacent surfaces Including dismanteling and making good the tiles if requiredcomplete all as specified and as directed by Engineer-In-Charge
Supply and fixing in repairs 100 mm dia CP brass shower rose swivel type with extension CP rod 15mm dia and 300mm long with connecting rod suitable for 15mm bore pipe .Complete all as specified and directed by Engineer-in-charge.
S&F in Repair PVC connection 15mm size with PTMT nuts, of length 600mm Complete all as specified and as directed by Engineer-In-Charge.
S & F in Repair viterous china wash hand basin of size 550 x 400 mm, white colour flat back excluding taps, chain and plug and porcelean stopper but including brackets and CP waste fitting . complete all as specified and as directed by Engineer-In-Charge
S & F in repairs vitreous china wash down water closet pedestal pattern (EWC) white excluding flushing cistern & Incl white seat cover closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and flush pipe.Complete all as specified and directed by Engineer-in-charge.
S&F in repairs vitreous china squatting pan Orissa pattern size 580x440mm white with P or S trap front or back inlet and integral foot rests including connection to trap to flush pipe etc complete including for making good to floor etc Complete all as specified and as directed by Engineer-In-Charge.
S & F in repairs CP health faucet special (1.5 mtr tube) with hook for EWC complete all as specified and directed by Engineer in charge
S&F in Repair Brass chromium plated tubular towel rail 20mm dia 60cm long with and including flanges complete all as specified and as directed by Engineer-In-Charge
S & F in repairs soap dish stainless steel as approved by GE complete all as specified and as directed by Engineer-In-Charge.
S & F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long. Complete all as specified and as directed by Engineer-In-Charge..
S & F in repairs Grating of 125 mm dia of stainless steel with or without waste hole Complete all as specified and as directed by Engineer-In-Charge.
Dismantling of PVC Pipes of any dia
S & F for PVC (SWR) pipes, bore of pipe in 110mm, single socketed, in any length, with rubber ring joints, laid in floors or fixed to walls Complete all as specified and as directed by Engineer-In-Charge.
S&F PVC (SWR)pipe single socketed in any length with rubber ring joints,laid in floors 75mm dia Complete all as specified and as directed by Engineer-In-Charge.
Supply and fixing in repairs Low density polyethylene pipes (LDPE) of pressure rating 6 kg/ cm2 of 40 mm dia bore for wash hand basin Complete all as specified and directed by Engineer-in-charge.
S&F in repairs PVC(SWR) branch pieces, single (Single Y) equal or unequal or with parallel branches 75mm dia Complete all as specified and as directed by Engineer-In-Charge.
S & F in Repair for PVC (SWR) bends, any radius, bore of pipe in 75mm with cement solvent in position .Complete all as specified and as directed by Engineer-In-Charge.
S & F in Repair for PVC (SWR) bends, any radius, bore of pipe in 110mm with cement solvent in position Complete all as specified and as directed by Engineer-In-Charge.
Supply and fixing PVC Cover lid for PVC water storage tank of capacity upto 2000 litres including PVC hinges and PVC .Complete all as specified and directed by Engineer-in-charge.
Dismantling water tanks of exc250 ltr but n exc 500 ltr. of any description from roof slab of building up to four storey and removing to store.complete all as specified and as directed by Engineer-In-Charge
Dismantling water tanks of exc 500 ltr but n exc 1000 ltr. of any description from roof slab of building up to four story and removing to store. complete all as specified and as directed by Engineer-In-Charge
Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) three layers hoisted and fixed in position complete and all as specified and as directed by Engineer-in-Charge
Supply and fixing 1000 Litre capacity Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) three layers hoisted and fixed in position complete and all as specified and as directed by Engineer-in-Charge.
S&F in Repair Stainless Steel Plate Rack of size 31'' x 30'' x 10'' with using stainless steel sheet of 0.63mm thickness Fixed with Rawl plug and screw. complete all as specified and as directed by Engineer-In-Charge.
S&F in repair Stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm complete.
S & F in repair Cast iron floor trap with CP grating weight of grating not less than 35 grams joints to waste pipe in run lead joint dia of outlet 75 mm of floor, trap with deep water seal and of heavy weight coated with tar/black bitumen paint including making good with existing surface by provision of tiles and refilling of the dismantel mnaterials complete all as specified and directed by Engineer-in-charge.
M/L for easing of door shutters for easy closing /opening tightning of hinges or changing the position of hinges adjustment of tower bolts , sliding door bolts with new screw etc complete all as specified and directed by Engr In charge (rate includes replacement of hinges if required)
M/L for easing of window shutters of any type , kitchen cupboards shutters , show case shutter , drawers including fixing of screws for easy closing /opening tightning of piano hinges or changing the position of hinges adjustment of adjusting of handles, knobs with new screw etc including other small adjustments including repair/ replacement of CP/MS powder coated sliding channels of standrad section by complete all as specified and directed by Engr In charge
S & F in repairs 300 mm long and 12 mm dia CP MS door bolt with hasp and staple (Bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminimum alloy.compete all as specified as directed by Engineer -in -charge
Supply and fixing in repairs helical door spring 250mm size with roller and roller plates of mild steel incl welding to angle iron plate or fixing with wooden/steel chowkhats as required and as specified including necessary welding where ever required. Make: Heera, Universal.Complete all as specified and directed by Engineer-in-charge.
Labour only for repairing of steel window /ventilator , making good to jamb/corroded portions and hinges , oiling to hinges / replacement of broken friction hinges by box type hinges including all welding , any fabricator work , bending etc and make functionable including any small fittings required etc upto 3 story bldg of MD accn scafolding arrenged by contractor and follow all safty rule folloew by Contractor complete all as specified.complete all as specified and as directed by Engineer-In-Charge Naote : Rates are deemed in quoted items above, Nothing shall be paid extra on this account.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads
S&F of loosed window glasses with oil putty complete with making good complete, window not exceeding 1.50 Sqm pto 3 story bldg of MD accn scafolding arrenged by contractor and follow all safty rule folloew by Contractor complete all as specified.complete all as specified and as directed by Engineer-In-Charge Naote : Rates are deemed in quoted items above, Nothing shall be paid extra on this account.
Supply and fixing 3 mm thick figured glass ordinary quality and size in any type of frames and glazing with oil putt (or beading) in square exc. 0.5 Sqm each incl hacking out old broken glass from wooden/steel frames .pto 3 story bldg of MD accn scafolding arrenged by contractor and follow all safty rule folloew by Contractor complete all as specified.complete all as specified and as directed by Engineer-In-Charge Naote : Rates are deemed in quoted items above, Nothing shall be paid extra on this account.
Supply and fixing in repairs GI wire cloth power woven 0.56 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanized wire staples for steel window and ventilator including providing MS beads and SS screws pto 3 story bldg of MD accn scafolding arrenged by contractor and follow all safty rule folloew by Contractor complete all as specified.complete all as specified and as directed by Engineer-In-Charge Naote : Rates are deemed in quoted items above, Nothing shall be paid extra on this account.
S & F in repairs GI wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tracks or wooden beeding patti.to gauge door shutters and wooden windows compete all as specified as directed by Engineer -in -charge
M&L for welding in repairs exc. 2.5cm but n exc. 5cm in length, thickness of metal to welded exc 6mm but n exc 9mm for steel windows , ventilators door frames , door hinges , door springs etc compete all as specified as directed by Engineer -in -charge
S&F Rubber based door bottom strip with aluminium angle not less than 25x25mm including fixing arrangement with screws properly & all as per manufacturers instruction complete all as specified and directed.
Taking down cement plaster of any thickness, raking out joints, hacking for key scrubbing down with water including terrazzo dado or wall finish such as tiles of any description and of any thickness, including for all necessary lowing etc, removal of rubbish of the premises; removal and depositing serviceable materials where directed and leaving the work clear for any type of plastering;Complete all as specified and directed by Engineer-in-charge..
M&L for 15 mm thick cement plaster in CM 1:6 on brick surface finished even and smooth without using extra cement in patches Complete all as specified and directed by Engineer-in-charge.
ditto Item No 57 but 5 mm thick rendering in cement plaster 1:4 on ceiling in patches
M & L for preparing plastered surfaces of walls and applying three coats of white wash compete all as specified as directed by Engineer -in -charge
M&L preparation of new plastered surface and applying 3 coats of white wash on ceiling complete.
M/L for filling floor /glazed tile joint with white cement tile grout with pigments matching with tiles including cleaning the tile surface properly.
M&L for 2 mm thick fibre glass reinforced plain translucent sheeting with fixing coach screw and washer on wall and roof complete.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
S&F steel work in rolled section design as approved, purlins, rafter, posts, gusset plates cleats, wind ties etc including special shape washers etc complete using ERW or induction butt welded tubes confirming to IS 116-1979 grade (medium grade) including one coat of red oxide primer and two coat of synthetic enamel paint complete.
M & L for preparation of old plastered surfaces of walls including rubbing down and stopping of distemper and painted surfaces and treating oil and greasing spots and applying Two coat of oil bound distemper over a coat of putty complete all as specified and directed
M & L for preparation of old plastered surfaces of walls including rubbing down and stopping of distemper and painted surfaces and treating oil and greasing spots and applying one coat of oil bound distemper complete all as specified and directed
M & L for preparation of old plastered surfaces of ceiling including rubbing down and stopping of distemper and painted surfaces and treating oil and greasing spots and applying one coat of oil bound distemper over a coat of putty complete all as specified and directed
M & L for preparation of old plastered surfaces of ceiling including rubbing down and stopping of distemper and painted surfaces and treating oil and greasing spots and applying two coat of oil bound distemper complete all as specified and directed
M&L for complete removal of existing treatment on ceiling, etc including cleaning of any mortar drops, fungus efflorescent salts etc and preparation of old plastered surfaces and applying two coats of white wash complete all as specified and directed.
M & L for preparing old plastered surfaces of wall incl removal of existing treatment and applying Two coat of white wash complete at any place /height such as room /stair case /common area etc all as specified and as directed
M & L for preparation of old painted wood or wood based surface of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
M & L for preparation of old painted steel and iron surfaces of any description, not other wise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Taking down carefully existing bitumen tarfelt including plastering upto 15mm thick cleaning the surface and make free of dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated and removing all foreign materials / Bitumenous primer completely , cleaning and washing the existing surface of roof/slab, terraces including flashings and junctions of parapets/Curb walls etc and as directed by Engineer-in-charge.
M&L for rendering 10 mm thick in CM 1:3 on concrete surfaces mixed including water proofing compound @ 0.12 ltr per bag of cement or as per manufacturer instruction and finishing the surfaces even and smooth without using extra cement Complete all as specified and directed by Engineer-in-charge.
M&L for cleaning the newly plastered surfaces throughly with wire brushes and providing water proofing treatment all as given here in after (a) Bituminous primer @ 0.3lit per Sqm conforming to IS-3384-1986 (b) 3 mm thick APP polymer modified moply FP with minimum wt 3.0 Kg per square metre membrane (one layer) laid by torch application method. (c ) Applying two coat of bituminous based aluminium paint @ 0.20 Kg in two coats (total in two coats) per square metre over membrane. Complete all as specified and directed by Engineer-in-charge. (d) The overlaps of APP shall be SSR part 1 and APP shall be laid by expert/ skilled workers only, bitumen based aluminious paint applied by brushes only. Note: (i) The contractor shall deploy skilled tradesman i.e. 01x carpenter, 01 x plumber with his helper and mason/welder (as required basis) and required T&P. The complaints slips daily in the morning collected by Contractor/superviser from AGE B/R office and same shall be resubmitted at evening with completion of alloted job duly signed by user . The complaint book shall be made by the Contractor as sample given by Deptt. No extra shall be paid on this account & rates are deemed to be included. (ii) The Contractor shall deploy 01x Computer Operator for monitaring day to day complaints received through ARMAAN APP/ daily complaint register to notedown complaints received telephonically and maintained complaints register and prepare complaint dockets for the execution of complaints for daily at 0830 hrs to 1800 hrs. At evening collecting the various complaint related output data and updated the ARMAAN APP/ daily complaint register on daily basis and submit the report to Engr-in-Charge. No extra shall be paid on this account & rates are deemed to be included. (iii) In case of failure to attend the complaint within 48 hrs. The penalty Rs 150/- for each complaint recovered from contractor. (iv) Due to petty rapair work, The work shall be executed in various bldgs with in AOR of AGE B/R-III under GE(E) Bareilly with small patch work/Small number complaints upto completion of Contract. This is applied for all items mentioned above. No extra shall be paid on this account & rates are deemed to be included .
NETRAPAL SINGH (BID ID -3244583)
M/S Gupta Builders (BID ID -3254788)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .