Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
11 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682001
REPAIR/MAINT OF COOLING APPLIANCES LIKE SPLIT ACs, WATER COOLERS, DEEP FREEZERS ETC AT INS DRONACHARYA UNDER GE FORT KOCHI
2026_MES_799692_1
8441/E8_GE_FORT_KOCHI
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
FORT KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE FORT KOCHI
₹28,000
Yes
20 Nov 2026
20 Nov 2026
18 Dec 2026
20 Nov 2026
11 Dec 2026
4 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for attending day to day complaints pertains to various capacity of cooling appliances, equipments as and when site requirement and complaints arises. Arrange Highly skilled Mechanic -01No with helper -01No to repair all type of cooling appliances, equipments like all type of ACs, all type of Refrigerators, Deep freezers, Water coolers etc.. It includes repairs, maintenance, timely replacement of spare parts, testing, smooth functioning of equipments. Also provide helper and necessary tools and plants for checking the equipments at existing location, find out the faults of equipments, rectification of minor problems, electric loose connections, compressor control panel resetting with electrical components like replacement of lugs/pin, MCB resetting, electrical wiring connections gas top up (gas shall be measured and paid separately under relevant item), to make the Cooling Appliances, equipments functional complete in all respect all as specified and as directed by the Engineer -In Charge.
Notes:
1. Complaints/service schedule list shall be collected from concerned JE/Engineer-In Charge and report back on daily basis.
2. The Serial item Nos of BOQ 02 to 18 of BOQ are outside the scope of this item.
3. A penalty of Rs. 500/- per day will be levied in case breakdown of equipment more than 3 working hours from the time of complaint registration due to non-attending.
4.The Item shall be measured and paid only for detecting the faults and for rectifications works. If any spare replacement needed in the work, the same shall be measured and paid under relevant item. | 100 | Each Job | - | - |
| 2 | Supply and fix factory built hermetically sealed compressor unit suitable for 1.5 Ton, single phase,230 V,50Hz capacity split / window type AC, testing the leak of compressor by charging Dry Nitrogen gas, evacuating the system and charging R-22/ 304a / 407a / 134 Refrigerant gas including taking out old unserviceable compressor with connected old material from the split type ACs / window ACs complete all as specified and as directed | 10 | Each Job | - | - |
| 3 | `-Ditto- all as per item No- 02 here in above but 2.0 TR | 3 | Each Job | - | - |
| 4 | `-Ditto- all as per item No- 02 here in above 2.5 TR up to 3.0 TR | 1 | Each Job | - | - |
| 5 | Material and labour for Leak testing of Window / Split type ACs, Water cooler, Refrigerator, Deep freezer etc. including filling of nitrogen gas for pressure testing, finding leaks, Vacuuming the system, necessary brazing work, charging with refrigerant gas (R-22 / R 304 a /R 407a /R 134) of required quantity, testing for proper functioning complete all as specified as directed | 40 | Each Job | - | - |
| 6 | Material and labour for onsite servicing 1.5 / 2.0 / 2.5/ 3.0 Ton capacity split / window type AC of any description by cleaning air filter, cooling coil / condenser coil and outer cabinet with pressurised water and detergent solution, applying new insulation to turn/damaged insulation complete all as specified and as directed. | 50 | Each Job | - | - |
| 7 | Supply and fixing in repairs of condenser fan motor with capacitor and mounting materials, single phase, 230 Volts, 50 Hz suitable for 1.0/1.5/2.5 /3.0 Ton capacity split type AC including taking out old unserviceable blower motor complete all as specified and as directed. | 15 | Each | - | - |
| 8 | Supply and fixing in repairs of thermostat cut off switch suitable for 1.5 / 2.0 / 2.5/3.0 Ton capacity split / window type AC complete all as specified and as directed. | 30 | Each | - | - |
| 9 | Supply and fixing in repairs of overload protective relay suitable for 1.5/2.0/2.5/3.0 Ton capacity window type AC complete all as specified and as directed. | 30 | Each | - | - |
| 10 | Supply and fixing in repairs of starting relay suitable for 1.5 /2.0/2.5/3.0 Ton capacity window type AC complete all as specified and as directed. | 20 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
8441Tenderdocuments.pdf
Tender Documents • 0.73 MB
BOQ_897242.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .