Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC VILL PO PIRUMADARA TEH RAMNAGAR DISTT NAINITAL UK | RAMNAGAR | NAINITAL | UTTARAKHAND | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹18.3 L+₹34,760.40 (1.93%)Rejected-Finance HOUSE NO 04 NEW SARASWATI VIHAR NEAR PAWAN VIHAR PHASE 6 OVER HEAD TANK BAREILLY 243006 UP | BAREILLY | BAREILLY | UP | 243006 | L2 | Rejected-Finance Being 2nd lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
29 Oct 2021, 6:00 pmClosed
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
REPAIR TO FENCING DRAINS CLEANING OF SEWAGE LINE MANHOLESSEPTIC TANKS SOAKAGE WELLS WATER TANK DRAIN PIPES REPAIR TO PATH AND CERTAIN MISC BR WORKS AT RTS AND DEPOT HEMPUR UNDER GE EAST BAREILLY
2021_MES_478481_1
C/8952/E8
Open Tender
Civil Works
Item Rate
300 days
HEMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE EAST BAREILLY
₹60,000
Yes
1 Mar 2022
30 Sept 2021
1 Nov 2021
30 Sept 2021
29 Oct 2021
13 Oct 2021
30 Sept 2021 - 7 Oct 2021
Amount
Demolition and breaking up of drain pipe any dia (salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed.
Excavating in trenches, n exc 1.5m wide and n exc 1.5 m depth; for foundation, etc. or for shafts, wells, cesspits, manholes,pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in Soft /Loose soil complete all as specified and directed.
M&L Plan cement concrete 1:4:8 type D2 using 40mm graded crushed stone aggregate in foundation filling as mass concrete complete all as specified and and as directed
Returning filling in, Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick, complete all as specified and directed.
M & L for removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate) concrete bed to drain pipe 100mm bore including packing under and haunching against the sides of pipes after laid and tested complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate) concrete bed to drain pipe 150 mm bore including packing under and haunching against the sides of pipes after laid and tested complete all as specified and directed.
M & L 100 mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars laid in trenches and jointes as specfified
M & L 150 mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars laid in trenches and jointes as specfified
Demolition of reinforced cement concrete (reinforced cut as required to facilitate to demolition) of any sescription and in any portion not otherwise specified complete all as specified and directed.
M&L cutting into existing manhole for connection of new drain pipe & removing existing drain pipe and cutting out branch channels and making good with packed spun yarn and cement mortar (1:1) and 150 mm bore pipe all as specified and as directed.
M&L for RCC (Nominal Mix) 1:2:4 Type B-1 (using 20mm graded crushed stone aggregate) for slab supported on walls, beams and column in floors, roofs, landings, balconies, canopies, deck slab, manhole cover and in shelves and the like Including all necessary form work complete all as specified and directed.
M & L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F in repairs vitreous china water closet pan (Pedestal pattern), white with and including plastic water closet seat, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flush pipe, anti syphonage pipe, etc. complete all as specified & directed. Make : Parryware Model C0252 or equivalent
S&F in repair vitreous China squatting pan 'Orissa pattern', size 580 x 440 mm white, with integral foot rests and cast iron 'P' or 'S' trap 100mm dia, front or back inlet including connections to flush pipe including making good to floor with existing finish complete all as specified and directed.
Demolition of brickwork built in cement mortar including all quoins, arches, pillars, etc,and rubbish off the premisses complete all as specified and directed.
M&L for brick work with fly ash bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as specified as directed
Taking down cement plaster of any description on brick walls including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 , including finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for cleaning /function of existing sewage system consisting of SGSW pipes, RCC hume pipes , CI pipes and PVC pipes of any dia at any depth, manholes of different sizes and depth of different size and capacity, waste and vent pipes fixed on walls, nahani/floor trap inside the bldgs,and gully trap outsides the bldgs etc incl removal of all blockage in the system, dewatering and desludging manholes by using honey sucking machine/ mechanical sewage suction pump and removal of sludge in covered vehicles outside the MD land all as specified and directed by Engr-in-charge. The unit rate quoted shall deemed to inclusive of the followings (i) Contractor has to engage three safaiwala and one supervisor for Each job ie per day of contract period. The team must be reported in the complaint cell/ sub div and with all necessary T&P such as green female bamboo strips, iron rods, sewage rodding machine, buckets, rope, ladder, safety mask, etc for execution of the item. The quoted rate shall also be included the cost of conveyance of workers, supervisors, materials and T&P for perday. (ii) Team of workers with T&P shall be attanded the complaints of the entire area as directed by Engr-in-charge and the completion of work shall be reported by 05:00 PM of every working day(iii) Contractor or his representative shall report daily at 09:00 AM in the office of Engr-in-charge/ complaint cell to receive complaint slip and necessary directions. Complaints received from JE/Engr-in-charge through telephone message also shall be attended on the same day.
(iv) Attendance register shall be maintained by Engr-in-charge at sub divn/ complaint cell. In case of absence of workers a penal recovery of Rs 500 per day per worker shall be imposed on contractor.(v) A complaint register shall be maintained by JE and proper record of compliants received and attended with date and time shall be recorded and shall be signed daily by both the parties. Complaint register shall be kept on record of Engr-in-Charge after completion of work.(vi) Complaints of blockage of sewage line/ manhole/ nahani trap if an attended within 24 hours after issuance of compliant slips or telephonic directional a penalty of Rs 200/- per each complaint shall be imposed on contractor.(vii) GE/Engr-in-charge will have no liability to give permanency of the employment of workers. A certificate in this regard will be rendered by contractor prior to the commencement of the work. (viii) Payment to the workers shall be properly receipted. A certificate shall be produced by the contractor that the every employee engaged by him have been paid their wage in full (ix) Contractor will not permitted to engage child labour in the work. (x) Contractor shall provide uniform with name plate as approved by Engr-in-charge to the workers. (xi) Supervison shall be obtained necessary directions from JE/Engr-in-charge and supervise the workers. (xii) Each worker shall be submitted affidavit in stamp paper duly notary that he will not claim employment from department. (xiii) Contractor shall submit accident /risk insurance policy of each worker engaged in cleaning sewage system.
M&L for cleaning of RCC or PVC water tank at any height (on accessible / inaccessible of roofs) by removing all scale, dirt, mud etc. from tanks capacity exc 500 ltrs but not exc 1000 ltrs unpluging flushing out and cleaning proporly internally and externally with detergent powder complete, and again cleaning with fresh water including plugging back from mouths of circulating pipes & change if nipple, union etc. complete all as specified and directed
Dismantling water storage tank exceeding 250 litre and not exceeding 500 litre capacity and removing from site and Incl S&F rotational moulded polythene water tank of 500 Ltrs capacity (cylindrical, vertical with close top) hoisted and fixed in position complete all as specified and directed.
Dismantling water storage tank exceeding 500 litre and not exceeding 1000 litre capacity and removing from site and including S&F 1000 litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) triple layer ISI marked hoisted and fixed in position including 20 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 2 1 0 gms ) complete all as specified and directed.
Pumping out of liquid sludge etc, from septic tank/soak well/ manhole complete all as specified and directed.Note- The unit rate quoted under this item shall deemed to include the arrangements of Sewage pump and delevery pipe minimum 60 mtr length and all necessary T&P with man and material and safety equipment etc .
De watering of well up to 12 Mtr deep and up to 8 mtr dia by portable pumping set and taking out manually waste material like sludge , mud ,soil , sanitory a material and other dirts etc from inner sump and outer housing sump by using labour/ equipment and depositing the same waste material at low lying area by digging pits all as , cleaning and washing the surface area of sump well with wire brush and removing the algae growth including removal of grass/tree roots including one coat brush of bleaching powder at wall of sump etc all as spedified and directed .
Taking down eaves gutters and rain water pipes(any size or pattern or dia) including all fittings heads shoes, bends necks, etc including removal from site (measured overall fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F in repair PVC (SWR) pipe 110mm bore single socketed with rubber ring joint fixed to walls including mild steel Stack clamps made out of 50mmx 5mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof surface complete all as specified and directed.
S&F in repair PVC (SWR) pipe 75mm bore single socketed with rubber ring joint fixed to walls including mild steel stack clamps made out of 50mmx 5mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof surface complete all as specified and directed.
S&F in repair bend PVC (SWR) with oval excess door 110mm bore complete all as specified and directed.
S&F in repair bend PVC (SWR) with excess door 75mm bore complete all as specified and directed.
S&F PVC (SWR) 75 mm bore junction single (Single 'T') equal or unequal with access door complete all as specified and directed.
S&F PVC (SWR) 110 mm bore junction single (Single 'T') equal or unequal with access door complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge
M & L for Non-Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 complete all as specified and directed.
M&L for gazed ceramic coloured tiles of size 300x200x7mm thick on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed with white or coloured cement and pigment to match the shade of tile over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
Taking up or down15 mm bore steel tubing and connections including cleaning for refixing or removal complete all as specified and directed by Engr-in-Charge
Taking up or down20 mm bore steel tubing and connections including cleaning for refixing or removal complete all as specified and directed by Engr-in-Charge
S&F 15 mm bore steel water tubing galvanized medium grade concealed in all type wall with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed b
S&F 20 mm bore steel water tubing, galvanized, medium gradeconcealed in all type wall with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed
S & F in repair for ISI marked Ball valves high pressure of PTMT 15mm bore with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed, (Minimum weight 210gms) complete all as specified and directed
S&F in repair service tank lid / cover of size 0.45 m dia and 0.20 m height made with 0.9mm thick GI sheet shaped into hollow semi sphere fixed to over head PVC service tank of 250 ltrs to 1000 ltrs capacity incl necessary nut, bolts washers and locking arrangement complete all as specified and directed.
S & F PVC in repair 110/75 mm dia PVC (SWR) vent cowl of any radius all as directed and specified.
S & F in repair 75mm bore size PVC(SWR) floor trap, Plain with grating including jointing with solvent cement complete all specified and directed.
Demolition of cement concrete (un reinforced) in ground floor & paving not exceeding 15 cm thick below or above ground level complete all specified and directed.
M&L for PCC (1:3:6) Type C2 using 20mm graded stone agg as in surface channel & drain incl form work.complete all specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth of cement concrete using extra cement including forms moulds, mitred/ stopped ends etc complete all specified and directed. .
M&L rendering 10 mm thick on fare faces of concrete surfaces in cm 1:4 is to be finished even and fair complete all specified and directed.
M&L for 50 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection/path laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges complete all as specified and directed.
M & L for chequered cement tiles 30 CM X 30CM X 25 MM thick or more, set, jointed & pointed in neat cement slurry in floor with grey cement mixed with colour pigments including packing to the edges with cement concrete 1:2:4 to required gradient complete all as specified. & directed.
M & L for 20 mm thick scred bed or bedding layer of mortar in 1:6 for laying of flooring complete all as specified and directed.
M&L for PCC 1:3:6, type C-2 using 40mm greaded stone aggregates as in sub base flooring 100 mm thick for receiving of floor finishes etc all as directed and specified.
M & L machine pressed precast concrete cloloured Interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade with including sand cussing and pointed with grey/coloured cement including packing to the edges with cement concrete 1:2:4 to required gradient complete all as specified.
M & L machine pressed precast concrete cloloured Interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 grade with sand including cussing and pointed with grey/coloured cement including packing to the edges with cement concrete 1:2:4 to required gradient complete all as specified.
Excavation in post holes (or similar holes) each n' exc 0.5 Cum getting out returing, filling in and ramming earth or brocken rubble mixed with earth around in layers not exceeding 25 CM complete all as specified and directed.
M & L for PCC (1:4:8) type D-2 (40 mm grade aggregate) as in foundation, filling and mass concrete complete all specified and directed.
M & L for providing RCC type B-1 1:2:4 (20mm graded aggr.)in precast post fencing post straining or terminal post strut etc. for fencing average sectional area exc.100sqcm but n'exc 250sqcm with or without chemfered angles and flat splayed rounded or meterd tops complete all specified and directed.
M&L for dismantling fencing wiremesh, any type Complete all as specified and directed by Engr-in-charge.
M&L for dismantling posts or struts (wood, steel or RCC) any section including taking out embeded portion and making good disturbed ground complete all as specified and directed by Engr-in-charge.
S&F for framed brackets of angles or tee with web and flanges cut to shape ,drilled counter sunk for screw incl bending and welding angles gusset plates etc FE-290(Gde -E- 165) complete all as specified and directed.
Supply only Chain Link MS galvanised fencing any size or type.complete all specified and directed.
Fixing GI chain link fencing of plain GI steel wire of dia 4mm and mesh size 100mmx100mm and tying to any type of standard rails, straining with required bolts etc. including provision of binding wire complete all as specified and as directed by Engr-in-charge.
M&L for mild steel deformed or twisted bars 10mm dia for stiffening of the fencing complete all as specified and directed
M&L of two coat of synthetic enamel paint over one coat of red oxide on new steel surfaces of any description over 10cm in width or girth incl preparation of surfaces.complete all specified and directed.
M&L for Mild steel in flat, round or square bars, in available length , conforming to Fe-410-W(Gde E-250) of quality-B complete all specified and directed.
S&F for mild steel bolts,purpose made with hexagonal or square head each screwed end to be fitted with washers and one hexagonal or square nut dia n.exc 12mm.complete all specified and directed.
M&L for PCC 1:3:6 Type C-2 (40mm graded aggregate) in foundation filling and mass concrete. Complete all as specified and directed.
S&F Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc as directed (Each line wire to be measured) complete as specified and as directed.
Removal of vegitation growth trees (any dia) complete with complete roots including application anti grroth chemical from RCC roof slab rain/ sewage water pipe complete including of brick / concrete masonry if required , scaffolding at any height and making good with and including materials as demolished , including matching with existing surface and removal from site complete all as specified and directed. ( NOTE:- Tenderers may note that amount of credit will be deducted from the total amount arrived at the time of Acceptance of contract.)
S S CONSTRUCTION CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .