Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC | L1 | Accepted-AOC BEING THE LOWEST BIDDER | |
| 2 | L2₹25.8 L+₹86,455 (3.47%)Rejected-Finance NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹28.6 L+₹3.7 L (14.8%)Rejected-Finance 00 KAMALWAGANJA ROAD NEAR HANUMAN MANDIR HARINAGAR SHIV PURAM PHASE 1 HALDWANI NAINITAL UTTARAKHAND 263139 | NAINITAL | UTTARAKHAND | 263139 | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
1 Oct 2024, 6:00 pmClosed
GE (AF) BARODA
GE (AF) BARODA ,DARJIPURA, GUJARAT-390022
REPAIRS / REPLACEMENT AND DAY TO DAY MAINTENANCE OF WATER SUPPLY DISTRIBUTION LINES / DI / GI / PPR / HDPE AT MAKARPURA AT AFS BARODA
2024_MES_671050_1
8900/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE (AF) BARODA
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
Yes
GE (AF) BARODA
₹48,000
Yes
14 Nov 2024
3 Sept 2024
3 Oct 2024
3 Sept 2024
1 Oct 2024
17 Sept 2024
3 Sept 2024 - 17 Sept 2024
Amount
Attending complaint /Repair/rectification of leakages to under ground water supply distribution lines 40mm to 50 mm dia HDPE/PVC/PPR/ GI tubing with provision of necessary excavation, returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of HDPE/PVC/PPR/GI unions/sockets/nipples as required at site complete all as specified and directed. Note :Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
All same as per item No 1.00 above but for GI tubing 80 mm dia
Attending routine complaints of over ground /on wall/on roof external water supply line including rectification of minor defects by taking down of existing HDPE/PVC/GI tubing up to 20mm/25 mm dia, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of gate valve/float valve packing sheet of gate valve and including replacement of HDPE/PVC/ GI nions/sockets/nipples etc as required at site complete all as specified and directed. Note :Spares HDPE/PVC/GI fittings required to be replaced and shall be measured and paid separately under respective items.
M & L for Detection of leakage in main water line and attending break down of water supply pipe line and repair to CI /DI/HDPE water mains of size 80 mm to 100 mm dia at a given notice including necessary excavation in mud, in any type of soil by manual or using special T &P such as JCB etc. De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/DI/HDPE specials such as collars bends/tail pieces etc and making joints complete all as specified and as directed. Note:-(i) Repair rectified by caulking of CI pipe are deeemed to be incuded with unit rate of job. (ii) CI specials, lead Joints, D-Joints, Clamp joints, mechanical joint etc shall be measured and paid under respective items of sch 'A'. (iii) Hiring charges of JCB up to 4 hours if required is deemed to be included of unit rate of each job beyond 4 hours shall be measured and paid separately
All as per item No 4 above but for CI/DI water mains of size150 mm bore.
All as per item No 4 above but for CI water mains of size 200 mm bore. Notes for Sl item No 1 to 6:- (a) The contractor will be alloted complaints at MES complaint cell on daily basis on all working days and sufficient tradesman / resources will be deployed by him/her for completion of day to day comaplaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consultation with JE E&M/Engr-in-Charge. (c) The contractor will make suitable arrangment for emergency complaints and will notify authorised representive/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard.
(d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rates shall deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Airforce station at Makarpura. (f) The contractor will maintain location wise record of each spare/fittings utilized as per inventry format given by AGE E/M and the same shall be submitted to E/M store yard on daily basis. (g) The stationery required for the job work such as complaints registers, job card and T&P shall be arranged and maintained by the contractor. (h) The cost of excavation / earth work and repairs to damaged roads, LT UG/HT cables, existing structure etc shall deemed to be included in the quoted unit rate and no extra payment shall be allowed on this account. (j) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items.
Hiring of JCB beyond 4 hours for rectification of leakage required against item Nos 4 to 6 of BOQ. Note:- Quoated rates deemed to be included provision of oprataor of JCB and fuel required.
Supply only GI Fittings 20 mm bore, medium grade , ISI marked , smooth finished and make embosed on fittings complete all as specified and directed for the following :-
Union
All equal Tee
Socket
X-Nipple
Nipple 75 mm Long
Nipple 100 mmLong
Nipple 150 mm long
Nipple 200 mm long
Nipple 300 mm Long
ElBow
Reducer 20 mm x 15 mm
Supply only GI Fittings 25 mm bore m medium grade , ISI marked , smooth finished and make embosed on fittings complete all as specified and directed for the following :-
Union
All equal Tee
Socket
X-Nipple
Nipple 75 mm Long
Nipple 100 mmLong
Nipple 150 mm long
Nipple 200 mm long
Nipple 300 mm Long
ElBow
Reducer 20 mm x 15 mm
Supply only GI Fittings 32 mm bore m medium grade , ISI marked , smooth finished and make embosed on fittings complete all as specified and directed for the following :-
Union
All equal Tee
Socket
X-Nipple
Nipple 75 mm Long
Nipple 100 mmLong
Reducer 32 mm x 25 mm
Reducer 32 mm x 20 mm
Reducer 32 mm x 15 mm
ElBow
Supply only GI Fittings 40 mm bore m medium grade , ISI marked , smooth finished and make embosed on fittings complete all as specified and directed for the following :-
Union
All equal Tee
Socket
X-Nipple
Nipple 75 mm Long
Nipple 100 mmLong
Reducer 40 mm x 25 mm
Reducer 40 mm x 20 mm
ElBow
Supply only GI Fittings 50 mm bore m medium grade , ISI marked , smooth finished and make embosed on fittings complete all as specified and directed for the following :-
Union
All equal Tee
Socket
X-Nipple
Reducer 50 mm x 40 mm
Reducer 50 mm x 32 mm
ElBow
Supply only HDPE Fittings 50 mm bore m medium grade , ISI marked , smooth finished and make embosed on fittings complete all as specified and directed for the following :-
Coupler
All equal Tee
Elbow
Reducer 50 mm x 20 mm
Supply only HDPE compressor Fittings 80 mm bore m medium grade , ISI marked , smooth finished and make embosed on fittings complete all as specified and directed for the following :-
Coupler
All equal Tee
Elbow
Reducer 80 mm x 50 mm
Supply and fixing of 20 mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
Supply and fixing of 25 mm ball brass valves, high pressure, with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying/taking out of cables,CI/GI pipe lines and getting out in sooft/loose soil all as specified and directed.
Returning, filling in trenches including spreading, levelling watering and well ramming in layers not exceeding 25 cms in soil complete all as specified and directed.
Removal of excavated material not exceeding 50Mtr and deposited where directed at a level not exe. 1.5M above the starting point complete all as specified and directed.
Taking out unserviceable CI/GI/DI water main from trenches including fittings / fixtures like bend, Tee, Union, Elbow etc with flanged ends all as specified and directed. Note: Excavation and earthwork will be measured and paid separately under appropriate items.
200 mm bore CI pipe
150 mm bore CI pipe
100 mm bore CI pipe
80mm bore DI pipe
80mm bore GI pipe
50mm bore GI
40 mm bore GI pipe
25 mm bore GI pipe
20 mm bore GI pipe
Relaying of old serviceable CI/GI/DI tubing obtained from Srl item No. 20 here-in-before above after cleaning the pipes internally and externally with all fittings laid in trenches, floor, under road wall ceiling, floors etc for following sizes :-
150 mm bore
100 mm bore
80 mm bore
80 mm bore
50 mm bore
40 mm bore
25 mm bore
20mm bore GI pipe
Supply & laying in trenches/ Walls 15mm GI tube medium grade, ISI marked with GI fitting such as tees,bend,elbows connecting to existing water main complete all as specified and directed
All as per item No 22 but 20mm bore GI tubing complete all as specified and directed .
All as per item No 22 but 25mm bore GI tubing complete all as specified and directed.
All as per item No 22 but 40mm bore GI tubing complete all as specified and directed.
All as per item No 22 but 50mm bore GI tubing complete all as specified and directed.
Supply & laying in trenches/ Walls/floor High density polyethylene pipes (HDPE) of 50 mm bore of pressure rating 6 kgf/cm2 laid in trenches, ISI marked with fitting such as tees,bend,elbows connecting to existing water main including taking down of existing pipe complete all as specified and directed.
All as per item No 23 here in before but 80mm bore HDPE pipes complete all as specified and directed
Supply, laying, and fixing of Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-7" of size 100 mm with Socket and Spigot ends conforming to IS - 8329 in standard lengths suitable for Push-On Rubber Gasket Jointing with inside Cement Mortar Lining and Black Bitumen external coating complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post all as specified.
All as per item No 23.00 here-in-before but of size 150 mm bore complete all as specified and directed.
Supply and fixing of Ductile Iron pipe bends (any type, radius and angle) tapers any type (Straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch "Y" junction, double branch, cross (socket and spigot type) for dia of pipe 80/100/150 mm bore complete all as specified and directed.
Demolition of concrete in ground floor and paving n.exc 15 cm thickness (Below or above ground level) complete all as specified and directed
M&L for PCC (1:2:4) type B1 using 20 mm graded aggregate in floors/pavings etc complete all as specified.
Dismantling / Taking down unserviceable Gun metal globe/gate valve and supply and fix new Gun metal globe / gate valve, screwed down high pressure with iron wheel head, screwed both ends for GI/PPR pipe including all fittings / fixtures like nipple, union etc complete for following sizes all as specified and directed.
50 mm bore size
40 mm bore size
25 mm bore size
Supply & fix SS Spindle CI sluice valve PN 1.6, long body, confirming to IS- 14846 : 2000. Complete and testing all as specified and as directed including dismantling of sluice valve of following sizes:-
150 mm bore sluice valve
100 mm bore sluice valve
80 mm bore sluice valve
Construction of brick masonry valve pit chamber of inner dimension 1200x1200x1050mm suitable for valves up to 200 mm size, with PCC 1:4:8 type D-2 for foundation, brick work in CM 1:6, rendering in CM 1:4, 15 mm thick mixed with water proofing compound, coping in PCC 1:2:4 type B-1, including necessary earth work, form work and provision of MS sheet cover of thickness not less than 2.80 mm on 50 x 50 x 6.0 mm Angle iron frame with locking arrangement, including painting over MS surfaces with two coats of synthetic enamel paint over one coat of red oxide primer etc.,complete all as specified and directed.
All as per item No 30 but valve pit chamber of inner dimension 950mmx950mmx950mm.
All as per item No 30 but valve pit chamber of inner dimension 750mmx750mmx1050mm.
M&L for painting the surface of each Pump- Motor set of any capacity with sluice valve completed with one coats of synthetic enamel paint complete all as specified and directed.
M&L for painting of CI/GI pipes at pump houses such as suction and delivery main with two coats of synthetic enamel paint as per MES colour code including preparation of surfaces by scrubbing down old existing paint complete all as specified and directed.
M &L for Cleaning and de-silting of RCC under ground sump with Chemical such as bleaching powder of following capacity after de-watering and cleaning scrapping with steel brushes/hessian cloths of the sump walls from inside and including floor of the sump complete and repair to vent pipes including providing wire mesh and clamps complete, providing two coat of white wash internally and writing Cleaning date and next due date with black enamel paint on white background complete all as specified and directed Note: If work is not done upto satisfaction level of concerned JE/AGE (E/M) , the work will be redone upto the required level without any extra cost. Necessary tools and safety measures to be arranged by contractor.
M & L for cleaning de-silting of Overhead tank of following capacity by scratching and cleaning inside walls,pillars and floors with bleaching powder and cleaning with water including taking out dirt, mud from storage tank including stag at site and removal from out side MD land and repair to vent pipes including providing wire mesh to cover all air gap holes and clamps complete providing two coat of white wash internally,and writing Cleaning date and next due date with black enamel paint on white background complete all as specified and directed . Note: If work is not done upto satisfaction level of concerned JE/AGE (E/M) , the work will be redone upto the mark without any extra cost. Necessary tools and safety measures to be arranged by contractor.
M & L for cleaning of static water tank(SWT) with all T&P and man power requered to pump out the existing water and removing the sludge and greet from 6f ft deep water collector and throwing it out side 50Mtr away from site complete all as specified and directed.
Supply and fix Gland packing for sluice valve and pumps of size 6mm thick complete all as specified and directed.
M & L for dismantling of defective sluice valve for repairs such as repacking stuffing box of sluice valve spindle, refacing, grinding, stuffing and threading of spindle, replacement of worn out check nut, repairs to gate assembly replacement of jointing materials such as rubber sheets, nuts, bolts & washers, gland rope and refixing in its original position, testing on completion etc complete all as specified and directed of following sizes:-
80 mm bore.
100 mm bore.
150mm bore.
200mm bore.
M & L for Framed work as in doors or gates of angle (40X40X5)or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete complete with locking arrangement all as directed.(Under ground Sump)
M & L for Mild steel, plain, black sheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up and welding handle for lifting, mitred angles, etc. as required for size 2.0mm complete all as specified and directed.
M & L for Drilling and tapping GI water mains (in position) for branch connections of the internal dia including ferrule of following sizes complete all as specified and directed.
20/25 mm bore size
50/80 mm bore size
Labour only for Disconnecting the existing non functional submersible pump set from electric supply from panel, dismantling existing CI bend from non return valve, removing and lifting out submersible pump set of any description and capacity & in any position, along with existing column pipe 100mm dia and existing submersible cable of any size from the bore well (approximately 450 feet depth of pump set from GL) and staking the pump and column pipes near by the bore well for inspection complete all as specified and directed. NOTE: - ( i ). Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc. shall be arranged by the contractor at his own cost.
(ii). Number of column pipe may vary from 30 to 50, The existing pipes & flanged joints shall be checked for its serviceability & unserviceable joints along with flanges shall be removed from the column pipe by cutting the pipes & making new thread in pipes for fixing of new flange joint, the cost of same shall deemed to be included in the quoted rate for above item. However cleaning of pipes if any required shall be measured & paid separately.
Labour only for Lowering down of the submersible pump set of any description and any capacity & in any position, in bore well along with column pipe 100 mm dia and submersible cable of any size (approximately 450 feet depth of pump set from GL) including necessary repair of pump to make it functional to the entire satisfaction Engr-In-Charge after opening and replacing worn out parts complete all as specified and directed including making necessary electric connections & testing the pump set after lowering. Note:- Fixing of replaced serviceable parts deemed to be included in above quoted rates. However, required spare parts shall be measured and paid separately supply only under rspective item of BOQ.
Supply only the following items/ spare parts suitable for AC submersible pump set of 15 HP capacity Complete all as specified and directed.
Cast iron stage bowl
Gun metal neck ring make NITCO’ or equivalent
Anti magnetic stainless steel pump shaft with key made : DD/’KSB or equivalent
Impeller gunmetal make: NITCO/ KSB or equivalent
Stainless steel sleeve( inlet) make : DD/KSB or equivalent
Stainless steel sleeve( outlet) make : DD or equivalent
Running bush outlet of gun metal
Stage bowl cover
Bolt stud with nut and washers
Running bush inlet of gun metal
Strainer stainless steel
Shaft nut with washer
Supply only the following items/ spare parts suitable for submersible motor of 15 HP capacity complete all as specified and directed.
Connector for motor
Steel bolt set
Key for thrust plate
Thrust bearing[set of 02]
Cable pressure washer
Thrust plate
Rewinding the submersible motor 15 HP of any make with PVC insulated super enameled heavy duty copper winding wire of same gauge and number of turns by using minilex fiber insulating sheet and sleeves etc complete all as specified and directed.
M&L for fabrication of motor pump base and suppporting leg of various pipes etc using MS flat 25x5mm iron strip/channel/angle Iron including necessary cutting , welding, bending etc complete all as specified and directed.
Disconnecting and taking out defective indicator lamps of any size & capacity after disconnecting all the electrical connections and supplying, fixing and testing Indicator lamps neon type suitable for 220 volts 50 Hz, AC supply including wiring with 1.5 Sqmm PVC insulated stranded copper conductor cable all as specified and directed .(Make : L&T/ BCH/Rishab).
Disconnecting and taking out defective Amp meter of any description along with CT’s and supply, fixing, connecting and testing Digital type of size 96mm×96mm, AC Amp meter 200 Amps with 3 nos C.T of Ratio 200/5 of class-1.0 including wiring with 1.5 Sqmm PVC insulated stranded copper conductor cable complete all as specified an directed. Make: DENKO/ ESCORP/AE.
Disconnecting and taking out defective MCCB after disconnecting all electrical connection and supplying, fixing, and testing MCCB, 4 pole, 415 Volt AC supply, 63 Amps having breaking capacity Icu = 25 KA with fixed thermal & magnetic setting complete all as specified and directed. Make : Havells/C & S Electric/ HPL / Standard.
Disconnecting and taking out defective MCCB after disconnecting all electrical connection and supplying, fixing, and testing MCCB, 4 pole, 415 Volt AC supply, 100 Amps having breaking capacity Icu = 35/36 KA with fixed thermal & magnetic setting complete all as specified and directed Make : Havells/C & S Electric/ HPL / Standard.
Disconnecting and taking out defective MCCB after disconnecting all electrical connection and supplying, fixing, and testing MCCB, 4 pole, 415 Volt AC supply, 200 Amps having breaking capacity Icu = 35/36 KA with fixed thermal & magnetic setting complete all as specified and directed Make : Havells/C & S Electric/ HPL / Standard.
Disconnecting and taking out defective MCCB after disconnecting all electrical connection and supplying, fixing, and testing MCCB, 4 pole, 415 Volt AC supply, 250 Amps having breaking capacity Icu = 35/36 KA with fixed thermal & magnetic setting complete all as specified and directedof Make : Havells/C & S Electric/ HPL / Standard.
Disconnecting and taking out defective MCCB after disconnecting all electrical connection and supplying, fixing, and testing MCCB, 3 pole, 415 Volt AC supply, 250 Amps having breaking capacity Icu = 35/36 KA with fixed thermal & magnetic setting complete all as specified and directed Make : Havells/C & S Electric/ HPL / Standard.
S&F in repair of contactor 4 pole with AC coil 415 volt 50 Hz, 25 Amp for motor starter complete all as specified and directed.
Material & labour for boring of holes under road for insertion of pipe of up to 200 mm bore, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including complete all as specified and as directed.
Collection of water samples from pump house makarpura and submitting in Chief Water Analyst's Laboratory, Department of Public Health and Preventive Medicine or any other goverment authorised organization and to analysis of the following properities (i) Physical examination (ii) Chemical examination (iii)Bacteriological examination (iv) Qualitative tests and collection of the reports from respective Deptt and submit the same to AGE E/M complete all as specified and directed Note : The rate is inclusive of testing charges of Deptt and sample collection plastic water cans complete
Supply and fix in repair of UPVC flange of 80 mm dia size complete all as specified and directed (Make : Aster or equivalent as approved) :-
M&L for repairing and servicing of leakages at flanges at various joints such as near pressure guage, motor, pipes and at various location inside Pump House premises by means of opening from joint and replacing flanges and PVC pipes of required size and length complete with teflon tape, gasket and other accessories complete clearing of leakage all as specified and directed .(Note: Complete clearing of leakage at various locations of Pump House will be considered under one job)Note: Any spares other then flanges or teflon tape/ packings/gaskets etc will be measured and paid under respective item.
S&F chemical feed dozer motor operated suitable for mixing hypochloride of capacity 100 ltr tank with stroke adjustment of 0 to 6 LPH complete with fittings and piping all as specified and directed.
Laour only for dismantling/taking down of complete summersible pump assembly after disconnecting existing water supply pipe line and electric connection from 30 HP motor complete all as specified and directed.
Rewinding the Summersible pump motor 30 HP of any make with PVC insulated super enameled heavy duty copper winding wire of same gauge and number of turns by using minilex fiber insulating sheet and sleeves etc complete all as specified and directed.
Supply & fix LED flood light 200 watt Amaze is LED floodlight luminaire with ultra sleek, light weight and with secondary optics, made of pressure die-cast housings with IP66 ingress protection and impact resistance of IK07. 4kV inbuilt and 10kV*external surge protection fixed on pole with fixing arrangement(angle iron, clamp, nut bolt and copper conductor 1.5 sqmm 3 core up to 12 mtr) complete all as specified and directed. Make : Bajaj/BJFL 200 W or equivalent of Philips/Wipro
S&F PVC insulated, PVC sheathed, submersible flat cable ISI marked with multi stranded copper conductor 1100 volt grade of size 6 Sqmm 3 core with PVC conduit of size 25mm dia as per site requirement for connecting pump from panel including heavy duty PVC conduit as per ground requirement complete including taking out of existing cable complete all as specified and directed.
M & L for water installation board as per direction by Engr-in-charge including light connection and fixing arrangement complete all as specified and directed.
M&L for Mechenical joint for under mentioned pipe all as specified and directed. Note: Excavation, returining filling & removal wk paid seperately.
S&F fully automatic star delta starter for 30 HP centrifugal Motor pump, relay range 40 to 50 Amp including taking down of existing old burnt startor complete all as specified and directed.
S&F fully automatic star delta starter for 15 HP Submersible pump, over load relay range 28 to 40 Amp including taking down of existing old burnt startor complete all as specified and directed.
Supply and fixing in repairs Single Phase Preventer for motor protection Circuit Breaker 10/15 HP Motor including taking down existing complete all as specified and directed.
Supply and fixing foot valve made of brass, suitable for 80 mm dia pipe including dismantling and taking out unserviceable foot valve complete all as specified and directed.
Supply & provide Aquafit (Calcium hypo chlorite) 65% - 70% chlorine content (Calcium based granular desinfectant for water treatment plants much more stable than chlorine gas & stronger than bleaching powder and sodium hypo chlorite packed in 45 Kg drum complete all as specified and directed. Make : Auafit & Equivalent.
S&F in repair of aviation obstruction light suitable for OH tank up to 50 mtr Height ,red colour,IP 67,with junction box ,aluminium LM6 casting ,heat resistant ,power 75VA borosillicate glasses and alternate circuite technology LED light fitting suitable for over head tank with and including 1.5 sqmm 2 core cable 20 meter for connetion and nuts, bolts, clamps complete all as specified and directed
Repiring of digital meter for main water supply replacing of screen with suitable size of wire complete all as specified and directed.
Cleaning and dressing surface of Surrounding area near about 900 sqm of Pump House, borewell of makarpura and malhar camp and cutting and removing of jungles, vegitation of creepers, small growth trees, trimming of small tree branches around/inside of arear with help of suiable cutting tools complete all as specified and directed.
BK CONSTRUCTION (BID ID -3105244)
M/S K K ENTERPRISES (BID ID -3111507)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .