Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹23.2 L+₹70,595 (3.13%)Rejected-Finance 5021 1 CAT III MODERN HOUSING COMPLEX MANIMAJRA CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹24.5 L+₹2.0 L (8.80%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹25.5 L+₹3.0 L (13.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹26.3 L+₹3.8 L (16.9%)Rejected-Finance 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | R N Enterprises L3 | R D Bansal L1 | HARISH SALES CORPORATION L5 | R S Enterprises L6 | M/s badrinath Traders L8 | LA ENTERPRISES L7 | PAUL REFRIGERATION L4 | M/s APEX ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down the existing unserviceable main Junction Box (One incoming and four outgoing) any type with MCBs any type including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of Apex paint with matching existing surface), complete all as specified and directed. | 45 | Each | 40 ₹1,800 | 100 ₹4,500 | 10 ₹450 | 5 ₹225 Lowest | 100 ₹4,500 | 120 ₹5,400 | 37 ₹1,665 | 11 ₹495 |
| 2.00 | Taking down the existing unserviceable DB's any type with MCBs any type including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of Apex paint to match with existing surface), complete all as specified and directed. | 180 | Each | 38 ₹6,840 | 25 ₹4,500 | 10 ₹1,800 Lowest | 15 ₹2,700 | 50 ₹9,000 | 120 ₹21,600 | 10 ₹1,800 Lowest | 31 ₹5,580 |
| 3.00 | Taking down carefully by sub main wiring/service connection of any type complete all as specifed & as directed. | 3,330 | Running Metre | 8 ₹26,640 | 1 ₹3,330 Lowest | 10 ₹33,300 | 5 ₹16,650 | 1 ₹3,330 Lowest | 2 ₹6,660 | 1 ₹3,330 Lowest | 20 ₹66,600 |
| 4.00 | Supply and fixing concealed double door sheet metal enclosure DB's for mounting MCB of 240 volt, 4 way SPN, white in colour with 100A rated busbar IP 43 rated, single pole and neutral and fixing in position including copper lugs for cable connection and concealed in wall including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of Apex paint to match with existing surface), complete all as specified and directed .Make : Legrand/Schneider/Havells Note- All termination in MCB DB by copper Lugs only. | 180 | Each | 650 ₹1,17,000 Lowest | 940 ₹1,69,200 | 900 ₹1,62,000 | 950 ₹1,71,000 | 700 ₹1,26,000 | 860 ₹1,54,800 | 1,450 ₹2,61,000 | 1,200 ₹2,16,000 |
| 5.00 | Supply & Fixing SPN MCB 240 volt 40 Amps, C curve with suitable size lug thimbles integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, with efficient air chanells etc complete all as specified.Make : Legrand/Schneider/Havells | 180 | Each | 505 ₹90,900 Lowest | 580 ₹1,04,400 | 900 ₹1,62,000 | 650 ₹1,17,000 | 600 ₹1,08,000 | 740 ₹1,33,200 | 675 ₹1,21,500 | 800 ₹1,44,000 |
| 6.00 | Supply & Fixing SP MCB 240 volt 5 to 32 Amps, C curve, with suitable size lug thimbles integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, with efficient air chanels etc complete all as specified.Make : Legrand/Schneider/Havells | 1,080 | Each | 110 ₹1,18,800 Lowest | 135 ₹1,45,800 | 190 ₹2,05,200 | 150 ₹1,62,000 | 150 ₹1,62,000 | 160 ₹1,72,800 | 165 ₹1,78,200 | 150 ₹1,62,000 |
| 7.00 | M&L for Concealed sub main wiring with two single core 6 sqmm (Nominal area) PVC Insulated and unsheated cable with strainded copper FRLS conductor in & including medium grade UPVC conduit (25mm) concealed in wall including one run of continuous PVC insulated FRLS copper Stranded cable of wiring size 6 Sqmm for earth continuity including connecting and making good disturbed surface (i.e plastering in cement mortar 1:6, one coat of putti and two coats of Apex paint to match with existing surface), complete all as specified.
Note:- Two run of 6 Sqmm (phase+ Neutral) + One run of 6 Sqmm for earth wire + One run of UPVC conduit shall be measured as one RM. | 2,160 | Running Metre | 289 ₹6,24,240 | 229 ₹4,94,640 | 250 ₹5,40,000 | 280 ₹6,04,800 | 180 ₹3,88,800 | 320 ₹6,91,200 | 260 ₹5,61,600 | 111 ₹2,39,760 Lowest |
| 8.00 | M&L for Concealed sub main wiring with two single core 6 sqmm (Nominal area) PVC Insulated and unsheated cable with strainded copper FRLS conductor in & including steel conduit ERW conduit (25mm) concealed in hard standing including one run of continuous PVC insulated FRLS copper Stranded cable of wiring size 6 Sqmm for earth continuity including Excavation of 25 cm width and 25 cm depth in any type of soil, returning filling and removing connecting/ cutting hard standing including making good disturbed surface to match with existing specifications), complete all as specified.
Note:- Two run of 6 Sqmm (phase+ Neutral) + One run of 6 Sqmm for earth wire + One run of steel conduit ERW conduit shall be measured as one RM. | 900 | Running Metre | 108 ₹97,200 Lowest | 292 ₹2,62,800 | 300 ₹2,70,000 | 410 ₹3,69,000 | 250 ₹2,25,000 | 400 ₹3,60,000 | 300 ₹2,70,000 | 295 ₹2,65,500 |
| 9.00 | Supply and laying 16 Sqmm twin core weather proof aluminium conductor cable Concealed in wall by using UPVC Conduit 32 mm dia, including connecting including making good disturbed surface (i.e plastering in cement mortar 1:6, one coat of putti and two coats of Apex paint to match with existing surface) complete all as specified.
Note:- One run of 16 Sqmm twin core weather proof aluminium conductor cable + One run of UPVC conduit shall be measured as one RM. | 270 | Running Metre | 250 ₹67,500 | 100 ₹27,000 | 200 ₹54,000 | 45 ₹12,150 Lowest | 50 ₹13,500 | 200 ₹54,000 | 100 ₹27,000 | 45 ₹12,150 Lowest |
| 10.00 | Supply and fixing concealed double door sheet metal enclosure DB's for mounting MCB of 240 volt, 8 way SPN, white in colour with 100A rated busbar IP 43 rated single pole and neutral and fixing in position including copper lugs for cable connection including making good disturbed surface (i.e plastering in cement mortar 1:6, one coat of putti and two coats of Apex paint to match with existing surface), complete all as specified and directed. Make : Legrand/ Schneider/ Havells.
Note - All termination in MCB DB by copper Lugs only. | 180 | Each | 1,250 ₹2,25,000 | 1,345 ₹2,42,100 | 1,300 ₹2,34,000 | 1,230 ₹2,21,400 | 1,000 ₹1,80,000 Lowest | 1,150 ₹2,07,000 | 1,900 ₹3,42,000 | 1,500 ₹2,70,000 |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
29 Jul 2025, 6:00 pmClosed
GE (AF) MC CHANDIGARH
GE (AF) MC CHANDIGARH
SPECIAL REPAIR/REPLACEMENT TO TPNs AND DBs AT CERTAIN SMQs AT 3BRD AF CHANDIGARH UNDER GE (AF) MC CHANDIGARH
2025_MES_719415_1
GE (AF) MC/CHD/T-19/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CHANDIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) MC CHANDIGARH
₹68,000
Yes
22 Sept 2025
9 Jul 2025
31 Jul 2025
9 Jul 2025
29 Jul 2025
22 Jul 2025
Amount
Taking down the existing unserviceable main Junction Box (One incoming and four outgoing) any type with MCBs any type including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of Apex paint with matching existing surface), complete all as specified and directed.
Taking down the existing unserviceable DB's any type with MCBs any type including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of Apex paint to match with existing surface), complete all as specified and directed.
Taking down carefully by sub main wiring/service connection of any type complete all as specifed & as directed.
Supply and fixing concealed double door sheet metal enclosure DB's for mounting MCB of 240 volt, 4 way SPN, white in colour with 100A rated busbar IP 43 rated, single pole and neutral and fixing in position including copper lugs for cable connection and concealed in wall including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of Apex paint to match with existing surface), complete all as specified and directed .Make : Legrand/Schneider/Havells Note- All termination in MCB DB by copper Lugs only.
Supply & Fixing SPN MCB 240 volt 40 Amps, C curve with suitable size lug thimbles integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, with efficient air chanells etc complete all as specified.Make : Legrand/Schneider/Havells
Supply & Fixing SP MCB 240 volt 5 to 32 Amps, C curve, with suitable size lug thimbles integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, with efficient air chanels etc complete all as specified.Make : Legrand/Schneider/Havells
M&L for Concealed sub main wiring with two single core 6 sqmm (Nominal area) PVC Insulated and unsheated cable with strainded copper FRLS conductor in & including medium grade UPVC conduit (25mm) concealed in wall including one run of continuous PVC insulated FRLS copper Stranded cable of wiring size 6 Sqmm for earth continuity including connecting and making good disturbed surface (i.e plastering in cement mortar 1:6, one coat of putti and two coats of Apex paint to match with existing surface), complete all as specified. Note:- Two run of 6 Sqmm (phase+ Neutral) + One run of 6 Sqmm for earth wire + One run of UPVC conduit shall be measured as one RM.
M&L for Concealed sub main wiring with two single core 6 sqmm (Nominal area) PVC Insulated and unsheated cable with strainded copper FRLS conductor in & including steel conduit ERW conduit (25mm) concealed in hard standing including one run of continuous PVC insulated FRLS copper Stranded cable of wiring size 6 Sqmm for earth continuity including Excavation of 25 cm width and 25 cm depth in any type of soil, returning filling and removing connecting/ cutting hard standing including making good disturbed surface to match with existing specifications), complete all as specified. Note:- Two run of 6 Sqmm (phase+ Neutral) + One run of 6 Sqmm for earth wire + One run of steel conduit ERW conduit shall be measured as one RM.
Supply and laying 16 Sqmm twin core weather proof aluminium conductor cable Concealed in wall by using UPVC Conduit 32 mm dia, including connecting including making good disturbed surface (i.e plastering in cement mortar 1:6, one coat of putti and two coats of Apex paint to match with existing surface) complete all as specified. Note:- One run of 16 Sqmm twin core weather proof aluminium conductor cable + One run of UPVC conduit shall be measured as one RM.
Supply and fixing concealed double door sheet metal enclosure DB's for mounting MCB of 240 volt, 8 way SPN, white in colour with 100A rated busbar IP 43 rated single pole and neutral and fixing in position including copper lugs for cable connection including making good disturbed surface (i.e plastering in cement mortar 1:6, one coat of putti and two coats of Apex paint to match with existing surface), complete all as specified and directed. Make : Legrand/ Schneider/ Havells. Note - All termination in MCB DB by copper Lugs only.
Supply & Fixing RCBO DP 30mA, 32 Amps, C curve with suitable size lug thimbles, integrated label holder, sliding bottom clamp, colour coded On/Off indication on dolly, with efficient air chanells etc complete all as specified. Make : Legrand/ Schneider/ Havells.
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal dust (100 kg) and common salt (300 kg), vegetable soil (300 kg), including GI wire 4 mm dia as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 15 mm dia light grade GI protection pipe upto 7.5 metre and watering pipe 20 mm dia light grade with funnel and wire mess including necessary earth work in any type of soil i.e Excavation, RFR and removing upto 500 mtr distance, Precast (Factory Manufactured) Earthing pit cover 450 mm x 450 mm x 450 mm having wall thickness 50 mm with Mortar design precast RCC Pit cover etc including Mild steel Earth marker with earthing result, date all as per Page No. 3 of SSR 2009, Page No 497 and AIR HQ Policy No Air HQ/37529/9/1/ERA/W(P&C) dated 21 Nov 2016 with dismantling old earthing, complete all as directed and specified. Note : The earth value/ result must be less than 5 ohms. RCC Earth pit cover Makes - OM Precast/ Dagar Tiles/ AC Construction/ Venus/Any other Precast RCC manufacturer.
S&F in replacement 15 mm dia bore G. I. LIGHT grade pipe for protection of earth GI wire complete all as specified and directed.
M&L in replacement 4 mm dia galvanized wire all as specified and directed.
S&F in replacement Galvanized steel flexible conduit with PVC Coating 32 mm dia nominal size all as specified and directed. Make - Precision/ Astral/ Polycab.
S&F in replacement Steel wire reinforced flexible UPVC Conduit Gland 40 mm dia outside diameter all as specified and directed. Make - Precision/ Astral/ Polycab.
M&L for rendering 10 mm thick in Cement Mortar 1:4 on brick work / concrete surface, finished fair and even complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of acrylic emulsion exterior grade (100%) over a coat of primer complete all as specified and directed.
Note :- Amount of credit of Rs. 44800.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
M/s APEX ENTERPRISES (BID ID -3375577)
R N Enterprises (BID ID -3372297)
PAUL REFRIGERATION (BID ID -3376221)
HARISH SALES CORPORATION (BID ID -3375388)
R S Enterprises (BID ID -3375661)
LA ENTERPRISES (BID ID -3374413)
M/s badrinath Traders (BID ID -3375662)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .