Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-AOC | L1 | Accepted-AOC SO issued | |
| 2 | L1₹23.6 LAccepted-AOC | L1 | Accepted-AOC SO issued |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
6 Jan 2020, 12:00 pmClosed
COMMANDING OFFICER, 60 ENGINEER REGIMENT
60 ENGINEER REGIMENT, PIN 914 060, C/O 99 APO
SUPPLY OF PUMP SET FOR WATER SUPPLY SCHEME
2019_ARMY_309294_1
6905/CQ/2019-20/52/OPW
Limited
Miscellaneous Goods
Supply
30 days
ENGINEER STORE DET, SEVOKE ROAD, SILIGURI
CLASS D, CATEGORY V
3 documents required · 3 mandatory
₹0
₹1.2 L
Yes
13 Jan 2020
25 Dec 2019
6 Jan 2020
25 Dec 2019
6 Jan 2020
31 Dec 2019
25 Dec 2019 - 31 Dec 2019
Pump Set model No WH1540 of 1800 LPF capacity with the minimum head of 300 mtr conforming to IS-7347. Ceramic piston, Aluminum zinc alloy crankcase, forged brass manifold. Durable packing design high-pressure pump. This professional grade tri-plunger pump comes standard with a brass manifold and ceramic piston sleeves to ensure long life and consistent pressure. Pressure 1500 psi, with water output of 40 Ltrs/Min (Max) as per site location. A three cylinder TP pump with pistons, capable of working at (-)15 degree centigrade. The pump is fitted with base plate, the pump shall have drain system to drain the water. The pump shall be coupled to a suitable engine of following specifications :- Engine Make Honda Air cooled totally enclosed four stroke Engine 11.70 HP (Max) 3600 RPM with self start. Fly wheel magnato air cleaner oil bath type, 389 CC type side valve four stoke air cooled horizaontal shaft single cylinder. The engine shall be capable of performing at altitude of 5500 mtr above MSL (Engine oil capacity 1.1 Ltr) Engine oil grade servo 20W-40. The Pump shall be supplied with foot valve & suction pipe and all accessories Make : Kirloskar/C&G/Honda. Note :- 1. Sample of Pump Set to be produced to Technical Evaluation Committee at the time of opening of technical bids on date of tender opening to check and confirm with correct technical specifications. If vendor fails to produce the sample at the time of opening of tender, the technical bids in respect of the vendor will be rejected during technical evaluation. 2. Please note that production of sample on the date of opening of tender does not warrant the acceptance of technical bids. The bids will only be accepted in case of the sample fulfills the correct technical specifications.
Pump Set model No WS20X power 2 HP capacity of fuel tank 1.5 Ltrs type of fuel petrol engine pump (Max) 3600 RPM speed rated power 1.5W. Aluminum zinc alloy crankcas. The pump is fitted with base plate. The pump shall be coupled to a suitable engine of following specifications :- Engine Make Honda Engine 2 HP (Max) 3600 RPM with self start. The Pump shall be supplied with foot valve and suction pipe and all accessories, Make : Kirloskar/C&G/Honda Note :- 1. Sample of Pump Set to be produced to Technical Evaluation Committee at the time of opening of technical bids on date of tender opening to check and confirm with correct technical specifications. If vendor fails to produce the sample at the time of opening of tender, the technical bids in respect of the vendor will be rejected during technical evaluation. 2. Please note that production of sample on the date of opening of tender does not warrant the acceptance of technical bids. The bids will only be accepted in case of the sample fulfills the correct technical specifications.
Y.R.International
Y.R.International
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .