Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹74.0 L
EMD Value
₹74,100
Closing Date
11 Dec 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
The Chief Engineer, TTD, Tirupati
Room No.132, Ground Floor, TTD Admn. Bldg., KT Road, Tirupati
Annual Maintenance contract of UPS, AMF, APFC Panels & VCB 11 KV panels available in AE-I & AE-II Sections of ESD -III, Tirupati for the period of Three (03) years 2026-27 to 2028-29.
1010830
71/SE(Elec)/TTD/TPT/2026-27
OPEN - NCB
Electrical Works
TIRUPATHI
11 documents required · 11 mandatory
₹2,622
₹74,100
26 Nov 2026
26 Nov 2026
26 Nov 2026
90 days
Annual Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of AMF Panels (Application to DG Set 100KVA to 750KVA) and inclusive of all Spares Cost for Replacement of During AMC Period, Such as timers, Contactors, fuses, indicators, MCBs, etc, complete (Except AMF Relay, 100A and above main incomer contactors / MCCB / ACB switch etc.) 4 Nos. x 3 years = 12 Nos.
Annual Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of APFC Capacitor Panel (Capacitor Duty Contactor type) 100 to 200 KVAR and Inclusive of all Spares Cost for Replacement of During AMC Period, Such as timers contactors, fuses, indicators, MCBs, Capacitor Duty contactors etc., complete. (Except APFC relay, Capacitors, 100A and above main incomer MCCB / SFDU switch etc.) 6 Nos. x 3 years = 18 Nos.
Annual Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of APFC Capacitor Panel (Capacitor Duty Contactors type) 20 to 50 KVAR and inclusive of all Spares Cost for Replacement of during AMC Period, Such as timers, contactors, fuses, indicators, MCBs, Capacitor Duty contactors etc., complete (Except APFC relay, Capacitors, 63A and above main Incomer MCCB / SFDU switch etc.) 5 Nos. x 3 years = 15 Nos.
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 2 KVA to 3 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). 3 Nos. x 3 years = 9 Nos.
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 4 KVA to 6 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). 10 Nos. x 3 years = 30 Nos.
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 7.5 KVA to 10 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). 10 Nos. x 3 years = 30 Nos.
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 25 KVA to 30 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc). 1 No. x 3 years = 3 Nos.
Only Labour / Engineering Supervision Service Charges for dismantling, shifting one place to another place in same city and Re- installation work UPS Systems with battery Bank
Supply & Fixing of 3 pole MCCB 120 Amps 25KA suitable for APFCC panel.
Supply & Fixing of 3 pole MCCB 250 Amps 35KA suitable for APFCC panel.
Supply & Fixing of AMF Relay Suitable for AMF Panel of 100 to 750 KVA DG Set
Supply 12 Stage APFC Relay for APFC Panels, Visa, Baulk or Reputed make.
Supply & Fixing of U/V Coil (or) Shunt Trip Coil (or) Holding Coil Suitable for ACBs 600 to 2000 Amps
Supply of 24V 20 Amps Battery Charger Working Voltage 230V AC with battery Reverse & Over load / Short circuit protection without Volt / Ammeter.
Supply & Testing of AVR suitable for 100-500 KVA DG Set Alternator
Supply of 3 Pole 110 Amps Power Contactor
Supply of 3 Pole 250 Amps Power Contactor
Supply and Fixing of DC Filter Capacitors 2.5Kmfd to 10kMfd / 100 to 250VDC 1Set (3Nos) 72V to 192VDC operating System 3 to 10 KVA ON-LINE UPS System
Supply and fixing of DC filter capacitors 2.5Kmfd to 10Kmfd 1 set (3Nos) 120V to 400V DC operating system 10 to 30KVA On-Line UPS system.
Supply installation Testing and commissioning of .......... KVA on line UPS system confirms to IS 16242(Part-I):2014 and IEC 60240-1 : 2008 with IGBT technology pure sine wave out put, double conversion with auto and manual static by pass switch single phase input / Single phase output. Makes: Numeric/APC/Fuji Electric/ Sakshham /Emerson
3.0 KVA , 72/96 VDC with Isolation Transformer
6.0 KVA , 192/240 VDC with Isolation Transformer
10.0 KVA , 192/240 VDC with Isolation Transformer
Supply and fixing of 12V 26 AH SMF battery with 3 years Warrentyincluding wire leads, connections etc complete. Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 42 AH SMF battery with 3 years Warrentyincluding wire leads, connections etc complete. Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 65 AH SMF battery with 3 years warrenty including wire leads ,connections etc complete. Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 100 AH SMF battery with 3 years warrenty including wire leads, connections etc complete. Makes: Quanta / Racket / Exide.
Supply of 12 V 180 AH Lead Acid Exide Battery XP-1800/equivalent for DG Set
Supply of 50 Sqmm copper flexible multi stand single core cable 2 Mtrs with suitable +/- terminals (4 Nos.) & copper lugs (2 Nos.) etc., for DG Set start motor to battery.
Supply Installation Testing and commissioning of self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR. including making connections with suitable capacity conductors/cables testing as required. Makes: L&T/Seimens/Epcos/Schneider/Havells/Legrand.
Heavy duty Three phase 440 V , 50 Hz capacitor (Bank)
Supply of 40-63A TP MCB 10KA C/D Curve ISI Mark. Makes: Legrand-DX3 / Schneider-A9/ Hager-h3/ Siemens 5SX4/ Havells STADx / Lauritz Knudsen (Formerly L&T)-AU/Indo Asian-Opti pro/ HPL (Techno)/Anchor (Uno Plus)
Supply of DP/TP/FP 1-way Sheet Steel enclosure with IP 20 Protection etc., complete as per IS 8623; IS 13032; IEC 61439-3. Makes: Legrand(Ekinox 3) / Schneider-A9/Hager -Novello+/ Seimens/Havells STADx/ Lauritz Knudsen (Formerly L&T)-Newrange/Indo Asian-Opti Pro/ HPL (Techno)/ Anchor (Uno Plus)
Carryout routine maintenance, servicing and testing of 630A to 1000A L.T.ACB by cleaning fixed contacts, moving contacts and arcchutes including servicing and putting the ACB in perfect working condition after detting all relay and ON, OFF mechanism etc done with only manufacturing companies / Dealers.
Supply of 3 core 2.5 Sqmm PVC insulated and sheathed FRLS/FRLS-H round copper cable for voltage up to 1100V as per IS 694/1990. Makes: Finolex / RR kabel / Havells /Finecab/KEI/ Polycab/ Gloster/ Goldmedal/GM/ Fortune Arrt /Anchor /Million
Supply of 3 core 4.0 Sqmm PVC insulated and sheathed FRLS/FRLS-H round copper cable for voltage up to 1100V as per IS 694/1990. Makes: Finolex / RR kabel / Havells /Finecab/KEI/ Polycab/ Gloster/ Goldmedal/GM/ Fortune Arrt /Anchor /Million
Supply of ………... Voltage Surge Protector, confirms to IEC/EN 61643-11.
2 Pole 2 Module 40 KA, 1.4 KV Makes: Legrand / Siemens /GE /Lauritz Knudsen (Formerly L&T)/ Hager/Havells
4 Pole 4 Module 40 KA, 1.4 KV Makes: Legrand / Siemens /GE /Lauritz Knudsen (Formerly L&T)/ Hager/Havells
Supply of ………... Off load Changeover Switch in sheet steel enclosure as per IS:13947
32A 240V DP Makes:HPL/Havells/Standard/IndoAsian/C&S
100A 415V FP Makes:HPL/Havells/Standard/IndoAsian/C&S
Supply of …… auto transfer switch for instantaneous switching between sources as per IEC 60947-6-1, Closed transition, (bare unit- without enclosure) with voltage surge suppressor, communication interface etc., complete.
125A, 415VAC, FP Makes: Socomec / Hager / ABB/ HPL/ Lauritz Knudsen (Formerly (L&T) / Havells
200A 415VACFP Makes: Socomec / Hager / ABB/ HPL/ Lauritz Knudsen (Formerly (L&T) / Havells
Annual comprehensive maintenance service contract for 11KV VCB's/RMU panel and load break switches which is inclusive of preventive maintenance / repairs cum service charges and exclusive of all psares cost Timers, contractors, fuses of VCB and LBS, indicators, Relays, Meter, PT & CTs, mechanism spares etc. complete for one year contract. 5 Nos. x 2 years = 10 Nos.
Purchase cost for old life over (failure) existing batteries any make any model under buyback offer.
Note:- The service reports must be sent to O/o.Divisional Engineer(Elec.)-II and concerned Dy. Exe.Engineer(Elec.)-III & AE TTD soon after each service.
Note: (1) The above rates are basic prices excluding GST and applicable GST will be reimbursed / paid as per actuals on production of proof. (2) The bidders are requested to quote the Tender percentage excluding GST. (3) Statutory deductions will be made as per norms, if applicable. Any modalities imposed on GST by the Government from time to time, the same will be implemented
(Rupees Seventy four Lakhs four thousand six hundred fifty one and Paise seventy seven only)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
NIT 71 BOQ.xlsx
TENDER_DOCUMENT • 0.02 MB
NIT 71 Conditions.doc
TENDER_DOCUMENT • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .