Loading…
Loading…
Tender Value
₹68.9 L
EMD Value
₹1.4 L
Closing Date
3 Feb 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
W5
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where: V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case the balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of Part I of GCC, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following c ategories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited:(i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or(ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or(iii) One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Definition of Similar work means :-" Any Signaling work involving Outdoor work and addition and/or alteration in existing Indoor signaling system. OR Any CLS or RI or EI or TPWS or IBS or ABS or BPAC work involving and Outdoor. Similar work to include Indoor if the tendered work involves addition and/or alteration in existing Indoor signaling system and Outdoor if the tendered work involves Outdoor work OR Any such work involving activities as given in the name of the tendered work."
After issue of LOA and before signing of Contract Agreement, successful bidder shall submit an undertaking/MoU from RDSO approved EI OEM to confirm compliance with extant RDSO guidelines and to meet contract specific requirements.
15 conditions · 4 needing a document upload
As per "CHECK LIST" document attached.
Following documents dully filled & signed to be uploaded. Standard formats are provided in (Annexure provided with tender document. Tenders are required for furnish details in thhese format).
"Tender Form" As per 'TENDER FORM" (Ref Standard format provided in Annexures).
Deviation Statement:- The tender shall submit a statement indicating any deviations against any clause of this tender including all the technical specication concerned to this work, duly signed and stamped on each page. If there are no deviation whatsoever, a Nil deviation statement should be submitted. (Ref Standard format provided in Annexures) In case firm has not submitted deviation or blank deviation statement it will be treated as NIL deviation.
List of works completed: list of works completed in the last seven financial years giving description of work, organization for whom executed, approximate value of contract at the time of award, date of award and date of schedule completion of work. Date of actual start, actual completion and final value of contract should also be given. (Ref Standard format provided in Annexures).
List of works on hand:- List of works on hand indicating description of work, contract value, and approximate value of balance, work yet to be done and date of award (Ref Standard format provided in Annexures).
Details of payment through NEFT/RTGS. (Ref Standard format provided in Annexures).
List of Personnel, organization:- List of Personnel, organization/technical staff available on hand and proposed to be engaged for the subject work, with their designation and experience.
Document for technical skill:- Documentary evidence necessary to establish that they possess the requisite skill, technical expertise, technical and skilled manpower and necessary equipment's to execute complete work covered in the schedule with stipulated specification/details.
Special instruction regarding payment of Bid Security: Excerpt of GCC April -2022 read as (i)Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' shall be exempted from payment of Bid Security. (ii)Labour Cooperative Societies shall deposit only 50% of above Bid Security. (Refer para 7.0 of CHAPTER-II {INSTRUCTIONS TO TENDERERS} of Tender document) for clarification see GCC April-2022. Mandatory submission of relvent document if applicable.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Alteration/Modification in existing Electronic Interlocking and part supply of signaling material, installation, testing & commissioning in connection with Ahmedabad-Palanpur section - Elimination of LC by providing road under bridge with cover approaches. (04Nos.) of Ahmedabad Division.
DRM-SnT-ADI-Sig22of25-26~WR
DRM-SnT-ADI-Sig22of25-26
Open
Works - General
12 Months
Ahmadabad, Gujarat
₹0
₹1.4 L
3 Feb 2026
5 Jan 2026
20 Jan 2026
86 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 45,61,901.65 | ||
| — | 1.00 | — | — | ||
| Modification/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines/TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU(Video Display Unit)/ LCP(Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards / relays / wiring material / connectors / fuses / communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/ LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTO CAD, soft copy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied. LC 239 at Khodiyar. | — | — | — | 36,50,493.18 | |
| — | 1.00 | — | — | ||
| Installation, testing and commissioning of electrically operated lifting barrier, complete with Casting of cement concrete foundation for pedestal and boom rest post, cabling, power supply connection & wiring with complete outdoor work as per approved drawing, wiring etc. | — | — | — | 52,293.57 | |
| — | 1.00 | — | — | ||
| Complete Indoor wiring testing &commissioning of station / LC Gate. This includes: (i) Prewiring& fixing of all base plates as per approved wiring diagram. (Supply of relay base covered in schedule 'A'. Excess quantity of base plate, if required will be supplied by Railways, prewiring of which will be done by the contactor.) (ii) Fixing of Relay groups on relay racks. (iii)Soldering of tag block terminals, dressing of wires as preapproved rack arrangements/Circuit diagrams. iv) Wiring on bus bar, fuse base condenser, resistance etc. as per wiring diagram (v) Wiring on Relay rack to relay rack via IDF, IDF to CT rack in relay room. vi) Wiring on panel tag block shall be repeated on tag blocks located on IDF & CT rack in relay room. vii) Wiring between control panel room &relay room. (viii) Supply of simulation panel, which shall be separate for each station and shall be left after commissioning. (ix) Provision 200 way tag blocks for data logger and providing jumpers between voltage free terminals on relay racks and data loggers, tag block with 0.6sq mm cable. (x) Wiring between Integrated power supply and data logger tag block with one square mm /0.6 sq. mm cable as per instruction of Engineer in- charge. (xi) Wiring of key lock arrangement at SM's office/ site& Earth leakage detectors. (xii)Wiring of block instruments from CT rack to block instrument terminals and includes supply &laying of indoor cables for this purpose as per standard arrangements xiii) All wiring &wiring materials necessary to complete Station/ LC gate (Within station limit) Installation but not cover in the schedule anywhere (xiv) Writing of description on all relays & other indoor equipments Note: All wiring shall be done as per std. practice of Railways with neat dressing & threading. All wiring will be done as per standard practice of Railways with neat dressing & threading. Detailed testing will include functional testing, selection table, and locking table and cross sheet testing with the help of operating panel and simulation panel in the presence of railway officials to their satisfaction. A copy tested selection table, locking table and cross sheet duly signed by contactor to be submitted to field office for record. This included supply of lamps for simulation panel for testing Note: Contactor will Put sufficient Staff to carry out the testing round the clock, if desired by Railway Engineer and will ensure that any alteration which become necessary during testing are carried out & testing is repeated wherever required. | — | — | — | 20,562.56 | |
| — | 1.00 | — | — | ||
| Dismantling/Releasing of the existing Mechanical/Electrical gate with barrier complete and transportation to nearest station/ depot of consignee or any other place as per railway requirement. This work to be done by contactors with his own vehicle and labour. | — | — | — | 5,324.24 | |
| — | 3.00 | — | — | ||
| Fabrication and fixing of Signal Number Plate( CSTE Drg No CSTE/6186) , 'A' Marker (Drg No. CSTE/6180), 'AG' Marker (Drg No. CSTE/6181), 'P' Marker (Drg No. CSTE/6182), Arrow Marker (Drg No. CSTE/6183), 'G' Marker (Drg No. CSTE/6184), 'C' Marker (Drg No. CSTE/6185). marker disk on signals as per standard practice All material required for this work shall be supplied by Contractor. | — | — | — | 4,083.27 | |
| — | 3.00 | — | — | ||
| Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by Railways.NOTE:- The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974). Main Signal Post with Signal Units, Surface base and complete fittings as per Western Railways standard practice. | — | — | — | 1,096.86 | |
| — | 4.00 | — | — | ||
| Installation of NE type Full apparatus case and casting of CC foundation in the ratio of 1:3:6 for NE type apparatus case as per drg. No.CSTE/5074 using std. size holding down bolts. Item include excavation, ramming, curing and plastering with 1:4 cement and sand mixtures. This includes filling up of hollow space in the foundation both sand and top surface, plastering. (Aggregate not exceeding 3.8 cm) Plastering should be done to level the surface on all sides upto 75 mm below the ground level after the cable is taken inside the apparatus case. Aggregate, sand, holding down bolts and cement to be supplied by the contractors. (NOTE: Due to local conditions in very special circumstances if the size of the above items required to be increased/decreased, the extra payment/deduction for variation of the CC work shall be calculated and paid on volumetric basis as per rate below.) This includes supply and fixing of telephone sockets, location lamp holder and making arrangement for pad locking of location boxes. | — | — | — | 35,244.72 | |
| — | 4.00 | — | — | ||
| Installation of NE type Half apparatus case and casting of CC foundation in the ratio of 1:3:6 for NE type apparatus case as per drg. No.CSTE/5074 using std. size holding down bolts. Item include excavation, ramming, curing and plastering with 1:4 cement and sand mixtures. This includes filling up of hollow space in the foundation both sand and top surface, plastering. (Aggregate not exceeding 3.8 cm) Plastering should be done to level the surface on all sides upto 75 mm below the ground level after the cable is taken inside the apparatus case. Aggregate, sand, holding down bolts and cement to be supplied by the contractors. (NOTE: Due to local conditions in very special circumstances if the size of the above items required to be increased/decreased, the extra payment/deduction for variation of the CC work shall be calculated and paid on volumetric basis as per rate below.) This includes supply and fixing of telephone sockets, location lamp holder and making arrangement for pad locking of location boxes. | — | — | — | 26,228.88 | |
| — | 4.00 | — | — | ||
| Fabrication and fixing of phenolic laminated sheet P3 Grade in full apparatus case NE type of size 10/12mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. | — | — | — | 10,255.8 | |
| — | 4.00 | — | — | ||
| Fabrication and fixing of phenolic laminated sheet P3 Grade in half apparatus case NE type of size 10/12mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. | — | — | — | 3,808.68 | |
| — | 1000.00 | — | — | ||
| Fixing of ARA Terminals /Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. | — | — | — | 13,190 | |
| — | 600.00 | — | — | ||
| Digging of 1.0 M deep and 0.3 M wide trenches in all type of soils including soft rock as per cable route plan, back filling after laying of cables. This includes clearing of roots of trees, bushes and temporary obstruction. Ramming of soils and planting of cables markers at every 30 to 50mtrs as well as where direction of trench changes. Where Digging of 1.0M depth is not possible or the same is reduced and accepted by engg. incharge of the work, payment shall be decreased proportionate to the depth excavated compared to 1.0M. Any dry stone pitching disturbed during the work shall be restored back to the original conditions by the contractor with own materials and labour. | — | — | — | 1,82,736 | |
| — | 100.00 | — | — | ||
| Manual Horizontal Auger boring for crossing of Road/track at depth of 1.0m from ground level/ bottom of rail flange including insertion of 100mm dia (with thickness 3.65mmm) DWC pipes/coupling etc all complete as per direction of engineer incharge. | — | — | — | 1,27,831 | |
| — | — | — | 1,36,500 | ||
| of S&T etc. This also of labels of give the from the divisional means. railway includes the | Laying provision to same his own of cable | Cables of includes laying colored plastic cable number. stores/consignee (Cables will be representative and length of the | types/pairs/quads and road cable or railways. site shall laying by report purposes. | ||
| — | 3.00 | — | — | ||
| Erection of CLS Post with base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any... The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. It also includes supply of padlock for signal units and cable termination box. X' arms to be provided by the contractor till the signals are introduced. The Item includes cutting of Signal post if required by Site In charge. 2/3/4 aspect signal unit mounted directly on signal post. | — | — | — | 7,469.94 | |
| — | 3.00 | — | — | ||
| Excavation & Casting of CC foundation in the ratio of 1:3:6 for Main signal post as per drg. no. CSTE/3122 using std. size holding down bolts nuts for erection of colour light signal post. Items include excavation, ramming, curing and plastering with 1:4 cement and sand mixtures. (Aggregate not exceeding 3.8 cm). Aggregate cement, sand and holding down blots, nuts to be supplied by the Contractor. | — | — | — | 24,993.9 | |
| — | 3.00 | — | — | ||
| Supply, fabrication & fixing of signal number plates as per site incharge. | — | — | — | 1,117.29 | |
| — | 2.00 | — | — | ||
| Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor). | — | — | — | 8,121.36 | |
| — | 1.00 | — | — | ||
| Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor. | — | — | — | 2,224.35 | |
| — | 100.00 | — | — | ||
| — | 10.00 | — | — | ||
| — | 1000.00 | — | — | ||
| — | 25.00 | — | — | ||
| — | 40.00 | — | — | ||
| — | 1.00 | — | — | ||
| Man-Days | 200.00 | — | — | ||
| — | 15.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .