Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹37.8 L+₹2.8 L (7.94%)Rejected-AOC SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L2 | Rejected-AOC Accepted | |
| 3 | L3₹39.7 L+₹4.6 L (13.2%)Rejected-AOC RH NO 06 KARMA KSHETRA HOUSING SOCIETY SECTOR 29 PRADHIKARAN RAVET POST DEHU ROAD 412 101 | NA | NA | 412101 | L3 | Rejected-AOC Accepted |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
6 Jan 2024, 6:00 pmClosed
GE dehu road
GE dehu road
SPECIAL REPAIR (MO) TO EXTERNAL ELECTRIC SUPPLY OF DEMPSY ROAD AND COD ROAD,SPECIAL REPAIR (MO) TO VOLTAGE STABILISERS OF PERIMETER LINE AT 29 FAD II III AREA,PROVISION OF EXHAUST FAN ALONG WITH CONNECTED ACCESSORIES AT MARRIED ACCOMDATION OF ALKAPU
2023_MES_630331_1
8825
Open Tender
Civil Works
Item Rate
270 days
GE dehu road
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE dehu road
₹83,000
Yes
22 May 2024
29 Nov 2023
8 Jan 2024
29 Nov 2023
6 Jan 2024
13 Dec 2023
Amount
Dismentling and taking down old unserviceable aluminium conductor steel rainforced from LT pole of any type and size all as directed.
Dismentling and taking down old unserviceable insulator of any type and size for 1100 volts grade from LT pole all as directed.
Dismentling and taking down old unserviceable Cross arms of MS channels or angle of any section including nuts and bolt complete all as directed.
Dismentling and taking down old unserviceable LT under ground cable of any size from ground,floor all as directed.
Supply,laying,jointing , testing and commisioning XLPE insulated armoured heavy duty electric cable with aluminium conductor,1100 volts grade, cross section area 185 sqmm X 3.5 core all as directeed. Make -Polycab
All as item no-5 here in before but size of cable 120 sqmm X 3.5 core.
All as item no-5 here in before but size of cable 95 sqmm X 3.5 core.
All as item no-5 here in before but size of cable 70 sqmm X 3.5 core.
All as item no-5 here in before but size of cable 50 Sq mm x 3.5 core.
All as item no-5 here in before but size of cable 35 Sq mm x 3.5 core.
All as item no-5 here in before but size of cable 16 Sqmm x 2 Core.
Supply, laying HDPE DWC flexible type of size 40 mm dia for protection of LT cable laid in trenches including insertion of the cable complete all as specified and directed. Make Infra/Supreme/Prince
Supply, laying HDPE DWC flexible type of size 50 mm dia for protection of LT cable laid in trenches including insertion of the cable complete all as specified and directed. Make Infra/Supreme/Prince
M&L in repairs for earthing with galvanised steel earth plate electrode 60cmx60cmx6.3mm burried directly in ground earth pit not less than 2.25 m deep below normal ground level with top edge of the plate vertically to depth of not less than 1.2m below ground level connected to and including GI strip of size 25 x 4 mm as earthing lead welded with earth electrode (excluding GI protection pipe) and connecting to equipments by means of earthing lead connecting to equipments by means of GI bolts & nuts etc. with provision of char-coal and salt etc. all as per electrical plate No. 3 of SSR Part I, 2009 including RCC cover and MS angle iron frame watering arrangement with GI pipe 20mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork and testing on completion etc complete all as specified and directed . Note: Rate quoted deemed to be including excavation by compressor M/C for Soft disintegrated rock to required depth.
Supply , installation, testing and commissioning of LT out door type feeder pillar box cubicle canoppy type made out of 3.00 mm thick CRCA sheet with IP-55 tested, welded frame construction with CRCA frame section. The feeder pillar box should be painted with powder coated paint . The feeder pillar box should be provided with gabble roof and should be with suitable size of angle iron leg for grouting. Panel shall have opening arrangement from in front and back side mounted on hinges. The aluminium bus bar of 400 Amps rating shall be sleeved with heat shrinkable PVC sleeved of different colour code for RYB and neutral The cable entry shall be from bottom of the box and should be provided with suitable dia gland plate for cables. The cable entry should be from bottom of the box & suitable dia gland should be provided for cables (i,e, for incoming and out goings). The panel shall be comprised and equipped with following switch gears and components :- Incomming (i) MCCB 200 Amp 4 pole breaking capacity 25 KA thermal & magnetic release -01 each.Make- L&T/ Legrand/Havells Outgoning (ii) MCCB 200 Amp 4 pole breaking capacity 25 KA thermal & magnetic release -01 each .Make- L&T/ Legrand (iii) MCCB 100 Amp 4 pole breaking capacity 16 KA thermal & magnetic release -01 each.Make- L&T/ Legrand/Havells. (iv) The pannel installed on PCC foundation all as specified and directed.
Supply installation testing and commissioning of CPRI approved factory make LT panel board outdoor type pedelstal mounted dust proof, weather proof, vermin proof front side double door hinge type with locking arrangement rear side single door hinge type with locking arangement, sheet steel cubical type with slanting roof made out of 3.15 mm thick CRCA sheet with powder coated finished suitable length and size. High conductivity 3 phase and neutral aluminium bus bar of 400 Amps capacity duly mounted on pre cast insulators including earth work excavation, PCC foundation necessary coping work, nuts and bolts and connecting electrically with suitable copper cable lug, cable glands etc complete all as specified and directed to accomodate the following items Incoming:- (i) MCCB 200 amps 4 pole 25 KA thermal & magnetic release - 1 Nos.(Incomming).Make- L&T/ Legrand/Havells (ii) LED type indication lamp for RYB. Outgoing: (iii) MCCB 63 amps 4 pole 16 KA thermal & magnetic release - 01 Nos. Make- L&T/ Legrand/Havells (iv) MCCB 100 amps 4 pole 16 KA thermal & magnetic release - 01 Nos Make- L&T/ Legrand/Havells . (v) MCCB 160 amps 4 pole 16 KA thermal & magnetic release - 02 NosMake- L&T/ Legrand/Havells . (vi) one blank space for MCCB (vii) The pannel installed on PCC foundation all as specified and directed
Supply, installation, testing and commissioning of CPRI approved factory make LT panel board outdoor type pedelstal mounted dust proof, weather proof, vermin proof front side double door hinge type with locking arrangement rear side single door hinge type with locking arangement, sheet steel cubical type with slanting roof made out of 3.15mm thick CRCA sheet with powder coated finished suitable length and size. High conductivity 3 phase and neutral aluminium bus bar of 150 Amps capacity duly mounted on pre cast insulators including earth work excavation, PCC foundation necessary coping work, nuts and bolts and connecting electrically with suitable copper cable lug, cable glands etc complete all as specified and directed to accomodate the following items Incoming:- (i) On load change over switch 415V of capacity 200 amps. -01. Make- L&T/ Legrand/Havells (ii) MCCB 200 amps 4 pole 25 KA thermal & magnetic release - 1 Nos. Make- L&T/ Legrand/Havells (ii) Digital Volt meter-01 no. (iv) Digital Amps meter- 01 Nos (v) LED type indication lamp for RYB.- 01 Set Outgoing: (vi) MCCB 63 amps 4 pole 16 KA thermal & magnetic release - 02 Nos. Make- L&T/ Legrand/Havells (vii) MCCB 100 amps 4 pole 16 KA thermal & magnetic release- 02 Nos. Make- L&T/ Legrand/Havells (viii) MCCB 40 amps 4 pole 16 KA thermal & magnetic release - 01 Nos. Make- L&T/ Legrand/Havells (ix) one blank space for MCCB (x) The pannel installed on PCC foundation all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure
Taking down voltage stablizer of any capacity with complete accessorie and deposited to MES store yard
Supply, install, testing and commissioning of Servo controlled voltage stabilizer ( Confirming to BIS 9815:Part1 :1994) Three phase,50 Hz, Naturally Oil cooled , with outdoor canopy headed IP 55 protection class (( CPRI approved) unbalanced type, copper wound, metallic body duly powder coated with lifting Hooks two nos , digital display type,relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification:- (a)Input voltage 340V-480V, (b)Output voltage stabilized at any deigned/desired voltage 415V +- 1% (c) Rated frequency 50 Hz (d) No distortion in wave form (e)Response time not to exceed 20 mille seconds (f) Sensitivity (+/-)1% (g) Rate of correction 8 Volt/second for single phase and 13 V/seconds for phase to phase (h) Efficiency more than 95% (i)Type of load : three phase , unbalanced type (j) Digital display Voltmeter/Ammeter Protections:- 1 Over load/Short Circuit protections 2 High/Low voltage cut off 3 By pass arrangement in case of emergency 4 Single phase sequence change protection Capacity:- 25 KVA.MAKE:Vintek Eleronics (Volina) ,Automatic Electric Note :- Approval from CPRI for Canopy headed IP 55 protection of any size to be submitted to Eng -in-charge before approval
Supply, install, testing and commissioning of Servo controlled voltage stabilizer ( Confirming to BIS 9815:Part1 :1994) Three phase,50 Hz, Naturally Oil cooled , with outdoor canopy headed IP 55 protection class (( CPRI approved) unbalanced type, copper wound, metallic body duly powder coated with lifting Hooks two nos , digital display type,relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification:- (a)Input voltage 340V-480V, (b)Output voltage stabilized at any deigned/desired voltage 415V +- 1% (c) Rated frequency 50 Hz (d) No distortion in wave form (e)Response time not to exceed 20 mille seconds (f) Sensitivity (+/-)1% (g) Rate of correction 8 Volt/second for single phase and 13 V/seconds for phase to phase (h) Efficiency more than 95% (i)Type of load : three phase , unbalanced type (j) Digital display Voltmeter/Ammeter Protections:- 1 Over load/Short Circuit protections 2 High/Low voltage cut off 3 By pass arrangement in case of emergency 4 Single phase sequence change protection Capacity:- 50 KVA.Vintek Eleronics (Volina) ,Automatic Electric Note :- Approval from CPRI for Canopy headed IP 55 protection of any size to be submitted to Eng -in-charge before approval
Excavation in trenches Soft / loose soil not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all as specified and directed.
Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft/loose soil
M&L for hard core of gauge n.exc 63mm thick of broken boulder spread levelling,watering, ramming to true surface complet all as directed.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as directed.
M&L rendering 10mm thick on fair faces of brick work or concrete surfaces inished even and smooth in cement mortar 1:6 complete alas directed.
M&L Rolled sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters ,post etc to Fe-410 gde E-250 quality-A complete all as directe.
M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet /vally gatter complete 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as directe.
M&L for painting with two coat of synthatic enamel paint over a coat of reoxide in ant steel surface complete all as directed.
M&L for cement concrete 1: 4:8 type D-2 using 40 mm graded aggregate as in foundation for pole including necessary form work all as specified and directed
M&L for cement concrete 1 : 2 : 4 type B-1 using 20 mm graded aggregate as coaping , filling and mass concrete necessary form work all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) complete all as directed .
M&L for point wiring one fan point controlled by one switch with 1.5 sqmm multistranded copper conductor cable of PVC insulated and unsheahed type alongwith 1.5sqmm PVC insulated unsheathed single stranded copper conductor cable for continous earthing in & incl casing / caping accessories having ISI marked surface type to be fixed with proper screws including hard PVC boards of suitable sizes & making arrangement for fixing switches, sockets, switch socket combination, fan, regulator etc all as directed.
S&F switch piano flush type single pole one way 5 Amps 220 volt 50 Hz.
S&F switch socket combination 2 in 1, 15 Amps flush type 220 volt 50 Hz.
S&F ceiling rose surface type 65 X 50mm, isolated body with 3 terminals to be fixed on PVC block all as directed.
Supply and fixing 450W,mini Dimmer 240V~ 50Hz,Dimmer and controller for ceilling fan 240 volt,50 Hz 6 step.Make: Anchor,Havells,HPL
Supply and fixing exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers and necessary fittings for fixing on wall or for fixing on window all as specified and directed.Make: Havells,Crompton,Bajaj
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 230mm sweep with, blades, and frame and louvers and necessary fittings for fixing on wall or for fixing on window all as specified and directed.Make: Havells,Crompton,Bajaj
Material and Labour for cutting the wall/window for installation exhust fan and make good the damage wall with existing surface to match the existing colour complete all as directed.
M & L submain wiring with two single core through PVC insulated unsheathed stranded copper conductor 4.0 sqmm (nominal area) drawing through PVC capping casing and 4.0 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly(Note : Cutting chases for counduit and sinking"s for boxes and makeing good to walls ,floors etc for sub main wiring will be measured & paid separately in respective items).
Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five starrated with brushless direct current motor (BLDC) all as specified and directed. Make :- Havells/Usha/Crompton.
Material and labour for fixing of fan hook including necessary fasnut bolts clamp etc as per site requirement all as spcified and directed.
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Starrated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc all as per directed. Make:Recold/ Havells.
Supply and laying GI pipe medium Grade including fittings, 20 mm dia.including cutting hole on wall and makegood the damage area all as directed.
Supply and lay pipe galvanized, “medium class”, including fittings, 40 mm dia including cutting hole on wall and makegood the damage area all as directed.
Supply and lay pipe galvanized, “medium class”, including fittings, 100 mm dia including cutting hole on wall and makegood the damage for protection cable all as directed.
Supply and fixing bip taps,cast copper alloy with crutch or butterfly hsndle,screwed for brass ferrule and fixed of size 20mm dia fancy type all as directed.
Supply and fixing stope valve,cast copper alloy ,screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions fancy type chromium plated 20mm dia all as directed.
Supply and fixing Braided Stainless Steel Connection Pipe suitable for geyser inlet and outlet connection with 15 mm bress nut of size 24 Inch complet all as directed.
Supply and fixing MCB DB two pole single door suitable for fixing MCB all as directed.
supply and fixing MCB SPN 20 Amps 220 Volt 10 KA as per Havells part no-DHMGCSNF006-032 all as directed.Make: Anchor,Havells,HPL
M/S kirpan Enterprises
Shri Sai Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .