Supplying, Fabrication and fixing of openable type closure for cut out at terrace level of Additional office building and creating storage facility at extended part of Lithium ceramic Laboratory at IPR Campus, BHAT, Gandhinagar - 382428
2023_IPR_761051_1
IPR/TN/CIVIL/05/2023
Limited
Civil Works - Buildings
Item Rate
60 days
IPR Campus, Bhat, Gandhinagar
As per Tender Documents
7 documents required · 7 mandatory
₹0
₹9,775
25 Sept 2023
11 Jul 2023
3 Aug 2023
11 Jul 2023
2 Aug 2023
26 Jul 2023
11 Jul 2023 - 18 Jul 2023
Amount
Supplying, Fabrication and fixing of openable type closure for cut out at terrace level of Addional office building at IPR Campus
Providing, fabricating, assembling, hosting / erecting and fixing in position at all heights / all levels / all floors / all shapes and sizes with all leads and lifts structural steel works made from tubular sections as per IS 1161(round hollow sections) or box sections (square, rectangular hollow sections as per IS 4923), plates as per detailed drawing and design including cutting, wastage, welding, bending (shop at site), hoisting, drilling, fixing in position, bolting wherever necessary, in position welding of required lengths, griding, finishing edges, filling the welded spots with paint, grouting in the RCC members including priming all the sections with one coat of zinc based yellow primer including preparing the surface, Scaffolding, Required size of anchor etc., complete at any heights/levels all as per instructions, specifications and as directed by Engineer – in – Charge (only standard measurements will be paid) Note: The fabrication work shall be confirm IS standard The quoted rates should be inclusive of the all materials, labours, one coat of primer, welding rods for all structural sections, bolts, washers, Scaffolding (Wherever necessary) as per suit and site conditions with taken care of safety measures, Payment shall be made only for actual material fixed at site as per standard measurement (weights) only. Rolling margin and wastage shall not be paid.
Providing and fixing of full threaded Anchor fastner rod- M10 x 115 (Material-Carbon steel of grade C 4.8 or above and Zinc plated ) with Epoxy resin anchor grout chemical (for RCC-High loading capacity, Non corrosive for rebar element, , Approved by European technical assessment, Fire resistance) and for Brick Masonary- (Fire resistance and high corrosion resistance) including drilling in R.C.C. etc., for all height and levels etc., The installation and the setting instructions of anchor fastner and chemica should be strictly followed as per the manufacturer’s recommendations. Complete all as instructed and directed by Engineer-in-charge. The Payment shall be made on the actual quantity of bolts fixed at the site.
Providing and Applying two coats of Synthetic enamel paint on MS member using 1st quality paint from approved manufacturer of approved colour and shade to give an even shade including scaffolding, removing of rust, cleaning the surface, preparing the surface to receive paint including filling cracks and creaves with Putty or other approved filler materials, applying two coats of paint to steel work. cost also includes thinner, filler, putty and other materials, necessary labours etc. complete as directed by Engineer in charge at all heights, in all floors. Painting on false ceiling includes taking down the material, surface preparation, Primer, paint and fixing the material back after painting. Note:- Actual painted area will be measured and paid. (1) Synthitic enamel Paint of approved brand (2) Putty suitable to Mild steel members of approved brand
Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS with 2mm thick flat
Civil work for creating storage facilty at Extended part of Lithium ceramic Laboratory at IPR Campus
Providing, fabricating, assembling, hosting / erecting and fixing in position at all heights / all levels / all floors / all shapes and sizes with all leads and lifts structural steel works made from tubular sections as per IS 1161(round hollow sections) or box sections (square, rectangular hollow sections as per IS 4923), plates as per detailed drawing and design including cutting, wastage, welding, bending (shop at site), hoisting, drilling, fixing in position, bolting wherever necessary, in position welding of required lengths, griding, finishing edges, filling the welded spots with paint, grouting in the RCC members including priming all the sections with one coat of zinc based yellow primer including preparing the surface, Scaffolding, Required size of anchor etc., complete at any heights/levels all as per instructions, specifications and as directed by Engineer – in – Charge (only standard measurements will be paid) Note: The fabrication work shall be confirm IS standard The quoted rates should be inclusive of the all materials, labours, one coat of primer, welding rods for all structural sections, bolts, washers, Scaffolding (Wherever necessary) as per suit and site conditions with taken care of safety measures, Payment shall be made only for actual material fixed at site as per standard measurement (weights) only. Rolling margin and wastage shall not be paid.
Providing and fixing of full threaded Anchor fastner rod- M10 x 115 (Material-Carbon steel of grade C 4.8 or above and Zinc plated ) with Epoxy resin anchor grout chemical (for RCC-High loading capacity, Non corrosive for rebar element, ,Approved by European technical assessment, Fire resistance) and for Brick Masonary- (Fire resistance and high corrosion resistance) including drilling in R.C.C. etc., for all height and levels etc., The installation and the setting instructions of anchor fastner and chemica should be strictly followed as per the manufacturer’s recommendations. Complete all as instructed and directed by Engineer-in-charge. The Payment shall be made on the actual quantity of bolts fixed at the site.
Providing and Applying two coats of Synthetic enamel paint on MS member using 1st quality paint from approved manufacturer of approved colour and shade to give an even shade including scaffolding, removing of rust, cleaning the surface, preparing the surface to receive paint including filling cracks and creaves with Putty or other approved filler materials, applying two coats of paint to steel work. cost also includes thinner, filler, putty and other materials, necessary labours etc. complete as directed by Engineer in charge at all heights, in all floors. Note:- Actual painted area will be measured and paid. (1) Synthitic enamel Paint of approved brand (2) Putty suitable to Mild steel members of approved brand
P/F 50 MM PUF insulated Panel with flat Ribbed sheet at top and bottom side 0.45 mm TCT color Coated GI Sheet with PUF as Insulation Sandwich Panel in between including closing of all the ends of PUF using appropriate End cap and GI sheet of required size and shape, the panel should be manufactured by pressure injection of CFC free Polyurethane foam at 38 + 2 Kg/m3 density, in between the outer and inner steel sheet surfaces and should be supplied in single length up to 6.00 meter or as desired by Engineer in charge. The sheet shall be fixed using self-drilling/self-tapping screws of size (5.5 x required length) with EPDM seal, silicon sealant at joints complete up to any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins, rafters and trussed and including cutting to size and shape wherever required including all materials labour, scaffolding, wastage, tools, tackles, equipment, transportation all complete as directed by engineer-in-charge. All overlaps shall be sealed with silicon sealants. Roof should be water tight. The PPGI Sheets shall be of minimum 240 MPA Steel grade & shall have a Zinc Coating of minimum 120 GSM as per IS 277/1992, 5-7 Microns of epoxy primer on both sides of the Sheet & Polyester top Coat of 18-20 microns on one side/outer side. The PPGI Sheets/PUF Panels shall have a protective guard film of minimum 20-25 microns to avoid scratches to finished panel during transportation.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :NOTE: All fitting works shall be carried out as per I.S specifications including necessary rivets, screws, lugs, scaffolding, etc., complete all generally as per drawings. The sizes of the components should confirm as per details in drawings. The cost also included for sliding arrrangements including locking arrangements of sliding window For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing of frame work (Styles and rails) for Doors shuters / window shutters with required sections including providing all items and hinged / pivoted arrangements for operation of shutters and cost for fixing of sliding arrangements etc., complete. (Aluminium beadings and glazing clips measured under this item only). For the detail specification, Consider Item no-2.05
Providing and fixing silicon sealant at the joint of aluminum and plaster of size 5 mm x 5 mm in triangle shape to make the surface water leakage proof at periphery of window from inside and outside both etc., as directed by EIC.
Supplying and fixing heavy quality fixtures and fittings for doors, windows, ventilators with necessary ss screws, nails, machine pins etc. at all floor levels complete, as directed and approved by Engineer-in-charge. The fixture & fastenings shall be provided as under : Providing and fixing hinges of Stainless steel of size 100mm*58mm*1.9mm including bolt, SS screw and other necessary connections and as directed by EIC.
Supplying and fixing heavy quality fixtures and fittings for doors, windows, ventilators with necessary ss screws, nails, machine pins etc. at all floor levels complete, as directed and approved by Engineer-in-charge. The fixture & fastenings shall be provided as under : Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm
Supplying and fixing heavy quality fixtures and fittings for doors, windows, ventilators with necessary ss screws, nails, machine pins etc. at all floor levels complete, as directed and approved by Engineer-in-charge. The fixture & fastenings shall be provided as under : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm
Supplying and fixing heavy quality fixtures and fittings for doors, windows, ventilators with necessary ss screws, nails, machine pins etc. at all floor levels complete, as directed and approved by Engineer-in-charge. The fixture & fastenings shall be provided as under : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Supplying and fixing heavy quality fixtures and fittings for doors, windows, ventilators with necessary ss screws, nails, machine pins etc. at all floor levels complete, as directed and approved by Engineer-in-charge. The fixture & fastenings shall be provided as under : Supplying and fixing Chromium plated Brass lock 4 levers 100mm of approved quality aluminum door lock with two keys, suitable either to single or double leaf shutters including making necessary recess in aluminum frame and fixing the lock with CP. Brass steel screws, etc.; complete as directed by Engineer-in-charge.
Providing and fixing compact sheet of 5 mm thickness and approved shade of approved Make inside wooden/Aluminimum partition / door etc; complete all as per approved drawing, colour, design & direction by Engineer-in-charge. The finished size of the panel shall be measured and paid. The cut edges of the compact sheet shall be provided with masking tape. Rate also includes for providing hole compact sheet of required size and at required spacing.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_800099.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .