Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹42.3 LAccepted-AOC 00 DEHAR VPO DEHAR SUNDER NAGAR MANDI HIMACHAL PRADESH 175030 | MANDI | HIMACHAL PRADESH | 175030 | L-1 | Accepted-AOC As per TEC Report. | |
| 2 | L-2₹44.4 L+₹2.1 L (5.01%)Rejected-Finance | L-2 | Rejected-Finance As per TEC Report. | |
| 3 | Rejected-Technical ETAH ROAD VIKAS NAGAR GANJDUNDWARA GANJDUNDWARA ETAH UTTAR PRADESH 207242 | KASGANJ | UTTAR PRADESH | 207242 | - | Rejected-Technical As per approval of competent authority |
Tender Value
₹39.8 L
EMD Value
₹80,000
Closing Date
15 Sept 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Dy. General Manager
PnC division, Parbati-II HEP,Nagwain,Distt-Mandi, H.P-175121
Construction of 11KV overhead line for Manihar site of Parbati-H.E. Project, Stage-II(Package No. C-671)
2022_NHPC_700705_1
NH/PP-II/PnC/Pkg.No.C-671/2022
Open Tender
Civil Works
Works
120 days
Manihar site, PHEP-II, Sainj(H.P)
Refer tender document
6 documents required · 6 mandatory
₹590
NHPC Ltd.
₹80,000
Yes
17 Dec 2022
14 Jul 2022
21 Sept 2022
14 Jul 2022
15 Sept 2022
14 Jul 2022
Amount
Supply of Steel tubular Pole 09 Mtr Long, approx. weight 154Kg, working load> 200Kgf/m2 as per IS: 2713 Part-II-1980 .
Supply of RCC Muff 2000mm for poles with cement concrete 1:3:6 (1 cement:3 course sand:6 graded stone aggregate 40mm. nominal size) .
Erection of Steel tubular pole single Pole (SP) structure including Digging Of Pit, Filling Of Pit + Ramming, Drilling Of Holes In Poles & X-Arm, Fixing Of Insulator, X-Arm, Fixing Of Barbed Wire, Danger Plate Knee Bracing Set, Top Clamp , Painting Of Pole etc.
Erection of Steel Tubular Pole Double Pole (DP) Structure including Digging Of Pit, Drilling Of Holes In X-Bracing Set, X-Arm, Erection Of Pole , Fixing Of Insulator X-Arm, X- Bracing Set, Fixing Of Barbed Wire Danger Plate, Filling Of Pit+ Ramming, Painting Of Pole etc.
Erection of Steel Tubular Pole Triple Pole (TP) Structure including Digging Of Pit, Drilling Of Holes In X-Bracing Set, X-Arm, Erection Of Pole , Fixing Of Insulater X-Arm, X- Bracing Set, Fixing Of Barbed Wire Danger Plate, Filling Of Pit+ Ramming, Paniting Of Pole etc.
Erection of Steel Tubular Pole Four Pole(FP) Structure including Digging Of Pit, Drilling Of Holes In X-Bracing Set, X-Arm, Erection Of Pole , Fixing Of Insulator X-Arm, X- Bracing Set, Fixing Of Barbed Wire Danger Plate, Filling Of Pit+ Ramming, Paniting Of Pole etc.
Supply and erection of of ACSR (Dog) Conductor of size 6/1/4.72mm diameter and including laying of conductor including stringing & sagging and binding with insulator etc. as required.
Fixing of jumpers
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20mm X 60 cm ), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc.
Supply of 11KV Disc insulator (Porcelene/Polymeric) 12KV,90KN for 11KV overhead lines with galvenised insulator fitting ball and socket type and complete with galvanised strain clamp, GI Bolts, nuts washers etc as required.
Supply of 11KV Pin insulator for 11KV overhead lines with large steel head GI Pin ,nuts washers etc (Porcelain 12KV, 10KN) as required.
Supply of Channel Iron X Arms(2340x100x50x6)mm as required.
Supply of Channel Iron X Arms (1270x100x50x6) mm complete as required.
Supply of CI X Arms(100x50x6)mm complete : length 2800 mm with fixing bolt nuts and washers including drilling holes and painting with primer as required.
Supply of C I X Arms(75x40x6)mm complete : length 2800 mm including drilling holes and painting with primer as required.
Supply of AI X Arms(2800x50x50x6)mm including drilling holes and painting with primer as required.
Supply of AI X Arms(1500x50x50x6)mm complete with fixing bolt nuts and washers, drilling holes painting with primer as required.
Supply of a set of cross bracing frame work for 11 kV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 5 mm angle iron to form a rectangle using 1800 mm horizontal X 2125mm diagonal member, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes, bolts and nuts etc. and painting with primer and finish paint as required.
Supply of AI X Arms2x(750x50x50) mm complete with fixing bolt nuts and washers including drilling holes and painting with primer as required.
Supplying of MS CI 100x50x6mm-100 mm flat iron pole top bracket for single 11 kV over head line conductor complete with fixing clamps, bolts, nuts and washers drilling holes for insulator pins, bolts and nuts etc. and painting with primer and finish paint as required.
Supplying of Danger plate (250x200x1.6mm).
Supply of barbed wire for anti climbing device.
Supply of Half Clamp( MS Flat 50x6mm) in 11KV overhead line.
Supply of Full Clamp( MS Flat 50x6mm) in 11KV overhead line.
Supply of Nuts, Bolts of different sizes (Galvanized/coated).
Supply of GI Wire of size 8 SWG for continuous earthing/guarding including binding etc. as required.
Erection/Sagging of GI Wire of size 8 SWG including Sagging, stringing and binding with insulator.
Erection of cradle guard as required.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as required.
Supply and erection of Gang Operated Air Break Switch unit 11KV, 400Amp.
Supply and erection of Drop out fuse unit 11KV, 400Amp.
Supply and erection of non-linear resistor type lightning arrester (Porcelain type) suitable for three wire 11KV overhead lines with rated voltage of 9 KVrms with a nominal discharge current rating of 5 KA and complete with galvenised clamping arrangement.
Supply of aluminium paint.
Supply , installation and commissioning of 11KV/0.415KV, 3 Phase, 100 KVA Delta/Star distribution transformer.
LT Panel Distribution Box with MCCB (160A,40KA,4P 01No) & SFU (32A, rewirable 04Nos).
Supply and erection of X Arm C.I. (100X50X6 mm), length 460mm for supporting main channel of Transformer complete with fixing bolt nuts and washers, drilling holes, painting with primer as required.
Supply and erection of MS A.I. (50x50x6mm), length 450 mm for Transformer belting/LT panel support, complete with fixing bolt nuts and washers, drilling holes, painting with primer as required.
Supply and erection of MS A.I. (50x50x6mm), length 950 mm for bed knee bracing of Transformer complete with fixing bolt nuts and washers, drilling holes, painting with primer as required.
Manual Carriage of material for 01 KM HT line material considering average distance from road to site work 1KM, including steel poles, cross arm, bracing, insulators, conductor, cables, stay etc.
Manual carriage of distribution substation (Transformer 100 KVA) average distance 1Km
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level with cement concrete 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size).
Ashoka Electronic & Electrical Industries
stage.html
html • 0.05 MB
technical_737395.pdf
PDF • 0.67 MB
techsummary_737395.pdf
PDF • 0.91 MB
finance_737395.pdf
PDF • 0.34 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_737395.pdf
PDF • 1.02 MB
LOAC671Bidder.pdf
PDF • 8.33 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .