Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 LAccepted-AOC 6 4 70 ADARSH NAGAR SAI BABA NAGAR ARAMGHAR RAJENDRANAGAR RANGA REDDY TELENGANA PIN 500052 | RANGA REDDY | TELANGANA | 500052 | ₹21.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹22.6 L+₹1.4 L (6.41%)Rejected-Finance 6 4 70 ADARSHNAGAR NEAR SHIVARAMPALLY RAILWAY STATION RAJENDRANAGAR RANGAREDDY 500077 | RANGA REDDY | TELANGANA | 500077 | ₹22.6 L+₹1.4 L (6.41%) | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical The firm has not submitted all required documents as per NIT |
| 4 | Rejected-Technical | - | - | Rejected-Technical The firm has not submitted all required documents as per NIT |
| Sl No | Description | Qty | Unit | Komere Manoj Kumar L2 | K arjun kumar L1 |
|---|---|---|---|---|---|
| 1.00 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch inproper shape, raking out joints and preparing a nd plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) | 79.87 | Sqm | 500 ₹39,935 | 450 ₹35,941.5 Lowest |
| 2.00 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. | 155.36 | Sqm | 600 ₹93,216 | 585 ₹90,885.6 Lowest |
| 3.00 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick | 2,123.64 | Sqm | 850 ₹18,05,094 | 799 ₹16,96,788.36 Lowest |
| 4.00 | Painting with aluminium paint of approved brand and manufacture to give an even shade . Two or more coats on new work | 2,123.64 | Sqm | 150 ₹3,18,546 | 140 ₹2,97,309.6 Lowest |
Tender Value
₹21.5 L
EMD Value
₹43,100
Closing Date
21 Oct 2025, 10:00 amClosed
COMMANDANT ENGINEER CONTRACT CELL SZ HQR
CONTRACT CELL SOUTH ZONE HQR CRPF HYDERABAD TELANGANA PIN 500005
Water proofing of rooftop of 3 Nos Blocks of Type III Block No A64 family quarters at Sector A and Water proofing of entire rooftop of 7 Blocks 40A 41A 42A 43A 44A 45A 46A of Type II at RAF Sector
2025_CRPF_881328_1
B.V-4/2024-25-SZ-Works (GC PPM) Major Work T/085
Open Tender
Civil Works
Item Rate
90 days
GC CRPF Pallipuram Kerala 695316
As per NIT
3 documents required · 3 mandatory
₹0
₹43,100
11 Nov 2025
14 Oct 2025
22 Oct 2025
14 Oct 2025
21 Oct 2025
14 Oct 2025
Amount
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch inproper shape, raking out joints and preparing a nd plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand)
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick
Painting with aluminium paint of approved brand and manufacture to give an even shade . Two or more coats on new work
Komere Manoj Kumar (BID ID -3301908)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.69 MB
BOQ_926340.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .