| 4 | Rejected-Technical | Rejected-Technical Technically not qualified as per bid |
| 5 | Rejected-Technical SHOPPING COMPLEX CHANDIPUR 756025 BALASORE ODISHA | BALESHWAR | ODISHA | 756025 | Rejected-Technical Technically not qualified as per bid |
Tender Value
Refer Docs
EMD Value
₹9,200
Closing Date
15 Oct 2020, 3:00 pmClosed
Director
Directorate of Lighthouses and Lightships Deep Bhvan Taratala Road Kolkata
Electrical wiring including procurement of electrical fittings and labour charges for new double storied inspection quarter at Puri lighthouse, Odisha.
2020_DGLL_587310_1
MS/KOL-07001/1/2019 (Puri)
Open Tender
Electrical Works
Works
90 days
Puri Lighthouse
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
Director of Lighthouses and Lightships, Kolkata
₹9,200
Yes
Deep Bhavan Kolkata-88
29 Oct 2020
29 Sept 2020
16 Oct 2020
29 Sept 2020
15 Oct 2020
29 Sept 2020
29 Sept 2020 - 5 Oct 2020
5 Oct 2020
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
2 Module (75mm * 75mm)
3 Module (100mm * 75mm)
4 Module (125mm * 75mm)
6 Module (200mm * 75mm)
8 Module (200mm * 75mm)
12 Module (200mm * 150mm)
Wiring for twin control light point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class pvc conduit with 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc as required.
Supplying and fixing of metal box of following sizes(normal sizes) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
100mmX100mmX60mm deep
200mmX150mmX60mm deep
200mmX250mmX60mm deep
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
6/10 Amp switch, 1-moduler, white
2-way 10 Amp switch, 1-moduler, white
16/20 Amp switch, 1-moduler, white
3 pin 6/10 Amp socket outlet, 2-moduler, white
6 pin 16/20 Amp socket outlet, 2-moduler, white
Telephone socket outlet, 1-moduler, white
TV antenna socket outlet, 1-moduler, white
Bell push, white (2-Modular)
Supply and fixing call bell/ door bell suitable for single phase, 230V complete as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ hylam sheet including connections etc. as required.
Installation , testing, commissioning of wall bracket/ ceiling fittings of all sizes and shapes containing up to two GLS/CFL/LED lamps per fitting, complete with all accessories including connection etc as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of length (up to 30 cm to 90 cm as required) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.( Up to 300 mm Sweep)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB C curve including connection, painting etc as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
2 x 1.5 sq. mm
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
3 x 6 sq. mm
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. (1-Pair)
Supply and drawing co-axial RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with sheath in the existing surface/recessed steel/ PVC conduit as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted\ including earthing etc. as required. (But without MCB/RCCB /Isolator)
12 way, Double door
Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note- vertical type MCB TPDB is normally used where 3-phase outlets are required)
4 way (4 + 12), Double door.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole 6A-4nos,/10A-4nos/16A-6nos
Double pole 32A
Earthing with G.I earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. Pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Labour charges for laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (up to 35 sq mm.), cutting the footpath and covering with complete electrical 3-phase connection at both the end ie power house side and IQ side.
Indicator 1-Modular, white. Make- Reputed
Exhaust Fan,200mm ,ventilating air brisk fan. Make-Reputed
Wall mounting revolving fan. 1600 mm sweep. Make- Reputed .
Led Mirror Light, 9 Watt, 1-feet. Make- Reputed
Led Foot Light, 4-Modular. Make- Reputed
DC multi tone Door bell. Make- Reputed
Chain LED light, blue colour, 5mtr length with driver. Make- Reputed
LED single bracket light with decorative glass. Make- Reputed
Ceiling Fan, Electro-phonetic lacquered/Electroplated surface for anti-rusting, High speed fan with wider tip blade for effective air circulation with Sweep 1200mm and High performance even at low voltage, Make- Reputed
16 Amp, 3-pin top. Make- Reputed
5 inch round hylam sheet of 4mm thick.
CI round Junction box, 1'' and 3/4'', 2mm thick (1 to 4 way). 1-way-40nos, 2-way-30 nos, 3-way-30nos, 4-way-20nos. (1”-60nos & ¾”-60nos). (3 inch dia round)
Installation charges of electric Geyser with 1-set of hot and cold pipe.
Installation charges of split Air Conditioner units.
Supply of Fan Rod of length- 2feet/2.5feet/3 feet.
Labour charges for laying of 1” PVC pipes at the time of slab casting with provision of GI ceiling fan hook box and GI junction box. (Ground and 1st floor roof approx. 250 sq mtr area) including materials like 1” PVC pipes & fan box .
Ground floor slab Approx 120 sq mtr.
1st Floor slab Approx 130 sq mtr.
HANNAN SK
MEPF INFRA
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .