Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC PM 3 6 TEGHORIA MONDAL PARA 3RD LANE KOLKATA 700059 | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.8 L+₹71,126.40 (10.0%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹8.0 L+₹86,806 (12.2%)Rejected-Finance 197 4 KANTADANGA ROAD FINGAPARA N24PGS PIN 743129 | FINGAPARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L3 | Rejected-Finance L3 | |
| 4 | L4₹8.0 L+₹88,243 (12.4%)Rejected-Finance DL 221 3 SALT LAKE SECTOR II KOLKATA 700091 WEST BENGAL | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L4 | Rejected-Finance L4 | |
| 5 | L5₹9.4 L+₹2.3 L (32.0%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹19,948
Closing Date
28 Feb 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
Annual Maintenance Estimate of the Electrical Installation of Vivekananda Yuba Bharati Krirangan Salt Lake Kolkata 106 Rectification of the damaged cable at practice ground - 1
2025_WBPWD_812787_1
WBPWD/EE/BED/e-NIQ-92/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Vivekananda Yuba Bharati Krirangan
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,948
10 Mar 2025
12 Feb 2025
3 Mar 2025
21 Feb 2025
28 Feb 2025
21 Feb 2025
Amount
Digging out the following PVC/A cable from under ground trench (1400mm depth) from existing damaged pillar box and relaying the same after cutting of damaged portion up to newly installed pillar box as per direction of EIC. 3.5 core 300 sqmm PVC armoured cable.
3.5 core 185 sqmm PVC armoured cable.
3.5 core 95 sqmm PVC armoured cable.
3.5 core 70 sqmm PVC armoured cable.
Laying only in under ground trench with brick protection as to GS for the following PVC/A Al. Cable. 3.5 core 300 sqmm PVC armoured cable.
3.5 core 70 sqmm PVC armoured cable.
S & F compression type gland complete with brass gland, brass ring, & rubber ring for dust & moisture-proof entry of XLPE/PVC cables as below. 3.5 core X 300 Sq.mm.
3.5 core X 70 Sq.mm.
3.5 core 95 sqmm PVC armoured cable.
Finishing the ends of following PVC/XLPE cables by crimping method incl. S&F solderless socket, tapes, anticorrosive paste & jointing materials. 3.5 core X 300 Sq.mm.
3.5 core X 70 Sq.mm.
3.5 core 95 sqmm PVC armoured cable.
Charges for megger testing of existing faulty 3.5 core 240/70/95 sq. mm cable after open the both end carefully by highly skilled technician.
Supply & Laying of 1.1 KV grade XLPE insulated. PVC sheathed, steel Armoured Al. conductor Cable of the following size, through underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed as per GS. as per direction of EIC) (Make - Gloster/ Polycab/ Havells/ KEI/ Polycab) 4 core X 300 Sq.mm.
4 core X 70 Sq.mm.
4 core 95 sqmm PVC armoured cable.
Supply & Fixing of 2000 Watt Metal Halide Ballast (Make: Philips/ Equivalent) as per direction of EIC.
Supply and fixing of 2000 Watt arena vision lamp holder base as per direction of EIC.
Supply & Fixing of 2000 Watt Ignitor (Make: Philips/ Equivalent) for as per direction of EIC
Making straight through joint (heat shrinking) of 1.1KV Grade 4 core 300 sqmm XLPE Al. Cable including supply of Heat shrinkable Jointing Kit. (Make-Raychem, Model-RLVJ) including necessary scaffolding arrangement from ground floor to the top of the cable tray as per direction of EIC.
Making straight through joint (heat shrinking) of 1.1KV Grade 4 core 70 sqmm XLPE Al. Cable including supply of Heat shrinkable Jointing Kit. (Make-Raychem, Model-RLVJ) including necessary scaffolding arrangement from ground floor to the top of the cable tray as per direction of EIC.
Making straight through joint (heat shrinking) of 1.1KV Grade 4 core 185 sqmm XLPE Al. Cable including supply of Heat shrinkable Jointing Kit. (Make-Raychem, Model-RLVJ) including necessary scaffolding arrangement from ground floor to the top of the cable tray as per direction of EIC.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: (a) By TATA-Medium GI pipe
Excavation of soil for installation of Earth Electrode and filling & ramming. (a) For Soft Soil
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Painting of iron surface with no. of coats of paints as given below with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint (i) One coat of red lead/Zinc chromate priming per feeder piller (ii) 1st coat of synthetic enamel paint over the primer per feeder piller (iii) 2nd coat of synthetic enamel paint over the 1st coat and also numbering the all feeder piller and sub-panels as per direction of EIC.
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – S & F of 415 V, 160 A, 4 bar Cu bar in existing feeder piller and reconnection the existing cables.
Supply & Fixing of 15 cm x 10 cm (6"x4") EI danger board on existing feeder piller
Interconnection wiring between busbar and SFU by 16 sqmm PVC insulated stranded FR copper wire with proper socketing as per direction of EIC.
Supplying and fixing 415 V 4 pole 63 Amps MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make - Legrand/L&T/ABB)
Supply and fixing of 415 V Four Pole 250 Amp MCCB of Breaking capacity 50kA with fixed thermal and fixed magnetic setting including release.(Make - Siemens, , cat no - 3VT2/Legrand/Schneider/L&T)
Supply and fixing of 415 V Four Pole 125 Amp MCCB of Breaking capacity 50kA with fixed thermal and fixed magnetic setting including release.(Make - Siemens,/Legrand/Schneider/L&T)
Dismantling of the existing Feeder Pillar box infront of Practice Ground-1, Lifiting & shifting to another places by hydra machine with 12 nos skilled labour with necessary tools & tackless as per direction of EIC.
Making a suitable size CC (4:2:1) foundtation for feeder pillar box in 3 Part having size of 1st Part 1200mm X 1200mm X 300mm, size of 2nd Part 1200mm X 800m X 200mm & size of 3rd Part 900mm X 600 X 150mm comp;lete with neat cemented finished plaster as per direction of Engineer-in-charge.
Cutting of extremly hard Cement Concrete having diamention 600mm X 300mm 3 layer hard concrete road incl hiring charges of vibrator machine and complete with clearence of rubish materilas for laying of 2 Nos 4 core 300 mm XLPE armoured cable as per direction of EIC.
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
M/S MANAB ENTERPRISE (BID ID -6173014)
M/S R. K. ENTERPRISE (BID ID -6159030)
SILICON SOFTWARE (BID ID -6171323)
M/s. Kar Electric Works (BID ID -6173040)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .