Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 CrAccepted-AOC H M APARTMENT 4C S J ROAD ATHGAON GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | ₹4.2 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹4.3 Cr+₹10.4 L (2.45%)Rejected-Finance | ₹4.3 Cr+₹10.4 L (2.45%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹4.5 Cr+₹31.2 L (7.38%)Rejected-Finance PO KETEKIBARI DISTT SONITPUR TEZPUR ASSAM 784001 | SONITPUR | ASSAM | 784001 | ₹4.5 Cr+₹31.2 L (7.38%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | Rejected-Technical | - | - | Rejected-Technical BEING ADEQUATELY LOADED |
Tender Value
₹4.7 Cr
EMD Value
₹5.5 L
Closing Date
26 Jun 2023, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
ADDN/ALTN TO CERTAIN SMQs AT AF STN TEZPUR (PHASE-V)
2023_MES_595289_1
88652/TEZ/E8
Open Tender
Civil Works
Item Rate
545 days
TEZPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
GE (AF) TEZPUR
₹5.5 L
Yes
21 Jul 2023
13 May 2023
28 Jun 2023
13 May 2023
26 Jun 2023
12 Jun 2023
Amount
B/R PORTION
Taking down chowkhats or frames exc 1.5 sqm but not exc 4 sqm each with shutters (without taking off shutters from the frames complete all as specified and as directed.
Taking down chowkhats or frames n.exc 1.5 sqm each with shutters (without taking off shutters from the frame complete all as specified and as directed.
Taking down shutter of any description exc 1 sqm and not exc 2 sqm each complete all as specified and as directed.
S&F factory made pressed steel door frame1.25mm thick (125x60mm wide ) for doors with one or more rebat including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and as directed.
S&F factory made pressed steel door frame1.25mm thick (105x60mm wide ) for doors with one or more rebat including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and as directed.
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed.
S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening,complete all as specified and as directed.
Material and Labour for 4.80 mm thick sheet glass, ordinary quality and glazing in square n exc 0.5 sq. m in each pane in Aluminium window shutters, complete all as specified and as directed.
Material and Labour for 4.80 mm thick sheet glass, ordinary quality and glazing in square exc 0.5 sq. m in each pane in Aluminium window shutters, complete all as specified and as directed.
Material and Labour for 5.0 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane in each pane in Aluminium window shutters, complete all as specified and as directed.
S&F 35mm thick 2nd class hard wood factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and as directed.
S&F 35mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F 100mm long Mild steel Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and as directed.
S&F 150mm long aluminium handles, cast type, anodised complete all as specified and as directed.
S&F 300mm long Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type and fixing clips of sheet, cast or extruded sections and fixing balts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S&F 200 mm long Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F mild steel helical door spring 300mm long, ordinary rat tail rod pattern springs including roller and roller plate to be fixed to MS chowkhat with necessary welding work complete all as specified and directed.
Material and labour for PCC(1:3:6) type C1 (using 20mm graded stone aggregate) for fixing hold fast/in MS chowkhat complete all as specified and as directed.
Materialas and labour for 50 mm thick plain cement concrete (1:3:6) type C1 using 20 mm graded stone aggregates as in floor/plinth protection including finishing surface even and smooth without using extra cement including roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.,and including brushing neat cement slurry with 3.0 kg of cement per sq. metre,complete all as specified and directed.
M&L for bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 10 mm wide and 50mm depth as in joint filling in plinth protection complete all as specified and directed.
M& L for water proofing treatment with APP based polymeric membrane 3 mm thick (minimum) weighing 4.0 kg per sqm reinforced with polyster non woven fabric shall be applied over and including one coat of water based bituminous emulsion primer on newly plastered surface @ 0.40 Kg / Sqm duly thermo fused by flame torch all as specified in method of application manual of the manufacturer complete all as specified and as directed.
Demoliton of PCC/Tiles of any description and in any position like roof slab/chajja, cleaning by picking, sweeping and washing down with water to remove dust, Brushing neat cement slurry with 3.0kg of cement per Sqm and provision of 10mm thick renderng in CM (1:3) finished even and smooth without using extra cement with water proofing compound @ 3% by weight of cement complete all as specified and as directed. Note : water proofing compound shall be measured and paid separately.
Disconnecting existing water storage tanks 500 ltrs to 1000 ltrs capacity, setting aside (for lowering if required) for repair, cleaning etc. and hosting if required reconnecting and refixing in position including cleaning, removing all scale dirt etc. form tanks and from mouths of circulating pipe, repalcement old tank nipple, unions, stop cock, tank cover etc. complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick or concrete surface finished even and fair complete all as specified and directed.
M&L for preparation of new surfaces wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified and directed.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed.
Resecuring or easing and adjusting without taking down the shutter of size exc.1 Sqm and not exc.2 Sqm complete all as specified and directed.
S&F in repair 20 mm dia anodised aluminium alloy tubular curtain rod with and including fixing brackets two nos door/window, stops, rollers etc. complete all as specified and as directed.
S&F in repair 2nd class hard wood timber in fillets, square, rectangular or triangular in section, clean sawn, fixed with nails, sectional area exc 13 Sqcm but not exc 25 Sqcm complete all as specified and as directed.
S&F 18/19 mm thick Veneered particle board, interior grade, solid core, with decorative veneers on both faces fix with screw to timber frame work as in shutter, shelves of cupboard including suitable beading to cover the exposed edges including taking down old boarding of any description and in any position complete all as specified and as directed.
S&F aluminium anodised hasp & staple 75mm long with hinge pin, including bolt to hinge plate and fixed with screws complete all as specified and as directed.
M & L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
M & L Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and directed.
S&F 100mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and as directed.
S&F 100x75 mm long PTMT/ PVC butt hinges medium weight complete all as specified and as directed.
S&F 100mm long aluminium anodised handles, cast type, anodised complete all as specified and as directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm as in doors, windows and Ventilators with & incuding necessary nails, wooden beadings n. exc 6 Sqcm in cross sectional area, screw bolts and nut bolts for complete all as specified and as directed.
S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm as in doors windows and Ventilators with & incuding necessary nails, wooden beadings n. exc 6 Sqcm in cross sectional area, screw bolts and nut bolts for MS window etc. complete all as specified and as directed.
M&L Cement concrete in sunken portion filling in mass concrete Type E2 1:5:10 (using 40mm graded aggregate) complete including demolition of PCC & tiles in sunken portion (unreinforced) of any description and in any position complete all as specified and as directed.
M&L for rendering 10mm thick in CM 1:3 using water proofing compound @ 3% by weight of cement finished even and smooth without using extra cement and curved adequtely both on floor and walls of sunken poriton and tested complete all as specified and as directed.
"Supply only" integral WPC complete all as specified and directed.
S&F in repair vitreous china squatting pan, ‘Orissa’ pattern’ size 580x440mm white, with integral foot rests(excluding flushing cistern) inciuding provision of PCC or lime concrete bedding, Vitreous china "P" trap and removal of debries complete all as specified and as directed.
S&F in repair PVC valveless syphonic action type Flushing cistern, 10 ltrs capacity with & including PVC Connection 15x450mm long, Flush pipe long/short & fixing brackets on walls etc complete all as specified and directed.
S&F Vitreous China Wash Hand Basin, white, flat back, size 550x400mm with & including brackets, cutting for and pinning in ends of brackets or eracting stand & PVC waste pipe 800mm long with CP coupling, CP Pillar Tap 15mm fancy type, PVC connection 15mmx450mm long etc. complete all as specified and directed.
S&F kitchen sink with drainage board made of stainless steel 1mm thick or lavortary with plug, washers PVC Waste pipe 800mm long and waste coupling including bedding in cement mortar to wall including fixing cantilevers backets and connecting union to pipe overall size 915mm X 460 mm bowl size 410mm x330mm x 160 mm complete all as specified.
S&F stainless steel kitchen plate rack of size ( 31"x24"x10" ) or ( 775 x 600 x250 mm) in size including all accessories required to fix in wall etc. complete all as specified and directed.
S&F 15mm bore bib tap fancy type with flange chromium plated alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F 15mm bore stop valve/angle cock with flange fancy type chromium plated alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes or union complete all as specified and as directed.
S&F in repair 15mm bore stop valve/angle cock with flange fancy type chromium plated alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes or union complete all as specified and as directed.
S&F galvanized steel tubing, medium grade, 15mm bore with all fittings and fixed to wall and ceiling or laid in floor at any height first/second/third floor complete all as specified and as directed.
S&F galvanized steel tubing, medium grade, 15mm bore with all fittings and fixed to wall and ceiling or laid in floor including taking down old one at any height first/second/third floor complete all as specified and as directed.
S&F galvanized steel tubing, medium grade, 20mm bore with all fittings fixed to wall and ceiling or laid in floor at any height first/second/third floor complete all as specified and as directed.
S&F 50mm bore high density poly ethylene pipes (HDPE) of pressure rating 6 Kg/Sqcm as In waste pipe for WHB/Sink including all connecting fittings like elbow complete all as specified and as directed.
S&F in repair 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed in wall or trenches complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S&F 75mm bore PVC (SWR) junction single (Single ‘T") equal or unequal with access door complete all as specified and as directed.
S&F 110mm bore PVC (SWR) junction single (Single ‘T") equal or unequal with access door complete all as specified and as directed.
S&F 75mm bore PVC (SWR) reducers (110x75mm) complete all as specified and as directed.
Matenal and labour for coloured glazed ceramic tiles 350x250x7/450x350x7/450x300 x7mm thick as in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in CM (1:4) for fixing wall tiles after dismantling of old floor,hearth or wall tiles including cement mortar bedding and rubbish off the premises complete all as specified and as directed.
Material and labour for Non skid coloured ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:6) for laying floor finishes after dismantling of old floor,hearth or wall tiles including cement mortar bedding and rubbish off the premises complete all as specified and as directed.
Material and labour for Non skid coloured ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm conforming to 1S 15622, economy class, Grade B lll, on vertical surface of wall such as dados, skirting etc., in floors etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in CM (1:4) for fixing wall tiles after dismantling of old floor,hearth or wall tiles including cement mortar bedding and rubbish off the premises complete all as specified and as directed.
Material and labour for Non skid coloured ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm conforming to 1S 15622, economy class, Grade B lll in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:6) for laying floor finishes after dismantling of old floor,hearth or wall tiles including cement mortar bedding and rubbish off the premises complete all as specified and as directed.
Material and labour preparation of old decorated plastered surfaces of wall and applying one coat of white wash on wall complete all as specified and as directed.
Material and labour preparation of old decorated plastered surfaces of ceiling and applying one coat of white wash on ceiling complete all as specified and as directed.
Material and labour washing, rubbing down and stepping and prepare old decorated wall surfaces and applying one coat of oil bound distemper complete all as specified and as directed.
Taking down carefully the existing unserviceable energy meter enclosure of any size and making good the disturbed surfaces of walls, Supply and fixing energy meter enclosure of size 1.5m x 1.0 m x0. 30 m fabricated out of 2mm thick MS sheet front openable with lock and key arrangement including weather, dust and vermin proof suitable for fixing single phase electric energy meter-06 Nos and fixed over the wall with necessary grouting arrangement including one coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F sheet metal enclosures MCCB DB 4 way VTPN, double door, vertical type, with 200 Amp rated bus bar including earth & neutral link, IP 54 protection, complete fixing accessories and taking out existing unserviceable MCB DB TPN etc any number of ways including MCB etc and making good disturbed surfaces of floors/walls/ceiling etc. complete all as specified and directed.
S&F sheet metal enclosures MCB DB 12 way SPN, double door, with 200 Amp rated bus bar including earth & neutral link, complete fixing accessories and taking out existing unserviceable MCB DB SPN etc. any number of ways including MCB etc. removing materials from site and making good disturbed surfaces of floors/walls/ceiling etc. complete all as specified and directed.
S&F Moulded case circuit breaker (MCCB) 800A, 4 Pole with microprocessor release, breaking capacity 50 KA for Automatic power factor correction panel complete all as specified and directed.
S&F Moulded case circuit breaker (MCCBs) Triple pole and Nuetral, 415 Volts, adjustable type 125 Amps, 25KA with current carrying capacity in the DB complete all as specified and directed.
S&F Miniature circuit breaker (MCBs) single pole and nuetral, 240 Volts, 10KA, 63 Amps, 'C' cure complete all as specified and directed.
Taking down old unserviceable Miniature circuit breaker (MCBs) single pole 5 to 32 Amps complete all as specified and directed.
S&F Miniature circuit breaker (MCBs) single pole, 240 Volts, 10KA, 5 to 32 Amps, 'C' curve complete all as specified and directed.
S&F Miniature circuit breaker (MCBs) single pole, 240 Volts, 40-63Amps, with 10 KA, 'C' curve complete all as specified and directed.
S&F of sheet metal enclosure SPN with two pin earth plug and socket complete with one SPN MCB 20 Amps,10KA, 240 Volts complete all as specified and directed.
S&F MCB protected socket 25A of dia 415mm x 375mm x 225mm , 4 module PVC plastic colour white box, 220V, 50Hz complete all as specified and directed.
M&L Point wiring complete with 1100 volt grade PVC insulated unsheathed multistranded 4.0 sqmm copper conductor cable confirming to IS 694 FRLSH drawn through and including rigid PVC casing and capping medium grade of size 25, etc fixed on wall/ceiling including provision of 4.0 sqmm PVC unsheathed copper conductor as earth conductor and connected to earth dolly for One 3 pin socket outlet, 15 Amps for geyser and making good disturbed surfaces complete all as specified and directed.
M&L for sub main wiring with two single core PVC insulated unsheathed cable 6.00 Sqmm (Nominal area) with multistranded FRLSH copper conductor cable, 1100 volts grade drawn through and including PVC casing & caping of size not less than 25mm dia with fixing accessories and earth continuity conductor of single core pvc insulated, unsheathed cable 6.0 Sqmm (Nominal area) with multistranded copper conductor, 1100 volts grade and making good disturbed surfaces complete all as specified and directed. Note - (i) Two runs of wiring cable, one run of earth wire and one run of PVC casing & caping shall be measured as one unit.
M&L for sub main wiring with two single core PVC insulated unsheathed cable 10.00 Sqmm (Nominal area) with multistranded FRLSH copper conductor cable, 1100 volts grade drawn through and including PVC casing & caping of size not less than 25mm dia with fixing accessories and earth continuity conductor of single core pvc insulated, unsheathed cable 10.0 Sqmm (Nominal area) with multistranded copper conductor, 1100 volts grade and making good disturbed surfaces complete all as specified and directed. Note - (i) Two runs of wiring cable, one run of earth wire and one run of PVC casing & caping shall be measured as one unit.
Removing of old unserviceable earthing set any type complete with taking out all accessories and unserviceable materials complete all as specified and directed. Note:- Cost of excavation, earthwork, removing and return filling etc. shall be deemed to be included in the quoted rates for the new earthing to be provided at BOQ Srl Item No. 86.00 and 132.00.
M&L Earthing complete with galvanized steel earth plate electrode 600mm x600mm x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected with galvanized 4 mm dia earth wire as earthing lead upto 7.5 mtrs from testing point fixed by means of steel bolts, nuts, check nuts and washer, of galvanized earth wire protected by 25mm bore medium grade galvanised iron pipe and other end connected to earthing test point including funnel with watering pipe of 20mm bore light grade galvanised iron wire mesh charcoal or cock end common salt in alternate layer of 15cm (compacted thickness) all around earth electrode with concrete earth pit in PCC (1:3:6) type C-1 50mm thick precast RCC M-20 nominal mix cover slab of size 450mmx450mm reinforced with 8mm dia TMT bar 10cm C/C and suitable handle of 10mm dia round bar including necessary execavation, earth work in soft / loose soil and deposited soil to a distance n.exc 50 M and necessary testing complete all as shown in electrical plate No 3 of MES Shedule Part -l complete all as specified and directed.
S&F smart single phase four wire energy meter BIS 16444 2015 (reaffirmed 2020) marked in exsisting meter board/floor panels having current range 10-60 Amp, 240 Volts, accuracy class1.0 complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece (Hot & Cold water connection pipe 1/8" long chromium plated with both end 1/2" brass fly nuts with washers and one 15mm short piece nipple etc. complete all as specified and directed.
M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
M & L for Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness complete all as specified and as directed.
Materal and labour for cable protection with subclass 'B' bricks old size, laid dry, flat over cable perpendicular across the cable in trenches complete all as specified and as directed.
Material and labour for reinforced precast concrete cable cover, class HV type 1 flat size 300mm x 180mm x 40mm complete all as specified and as directed.
Supply, installation, testing and commissioning of step down transformer outdoor type plinth mounted, HT 11 KV, 3 Phase 433 Volts, 4 wire 50 Hz delta star connected, vector group DYN-II double copper wound ONAM manual type on load tap changing facility on HT side to vary secondary voltage of +7.5% in steps of 2.5% continuos rating of capacity 630 KVA including bushing on HT and cable end box on LT side. the transformer shall conforming to IS-1180 part 1:2014 Level-2 and BEE certified complete with all standard fittings and accessories gauges, first filling of transformer oil etc. complete including suitable plateform with PCC/brick work and finished with CM 1:4 as per manufacturer recommended length, width and height shall be 300mm x 1750(foundation depth should be 750mm from ground level) 125mm thick RCC slab (1:2:4) all as specified and as desire type B-1 (Nominal mix) using 20mm graded stone aggregate on top of the plateform reinforcement should be 10mm dia. @150mm c/c both way 02 Nos ISMB 150. (a) Oil conservator with filling hole and cap drain valve and oil gauge. (b) Silica gel breather with connecting pipe, first fill of dehydrating agent. (c) Explosion relief mounted on tank with double diaphagram and equalizer pipe connected to conservator air spoon (Pressure release valve) (d) Air release plug. (e) Oil temperature indicator (gauge) having range 0 degree celcius to 200 degree celcius. (f) Thermometer pocket with themometer dial size 100mm dia. (g) Drain valve with threaded adapter. (h) Sampling valve (j) Cover lifting eyes. (k) Jaking pads, handing and lifting eyes. (l) Roller type four No. wheel
Item No. 95.00 Contd.... (m) Rating plate and terminal marking plate cable end box on LT side. Also extra bushing for neutral outside the LV side hand hole of sufficient size to assess the inferior of the tank. (n) HT bushing on 11KV. (o) First filling of transformer oil. (p) Buchholz relay with tripping system/mechanism. (q) Digital thermometer with thermometer pocket. Note:- 1. The transformer shall be tested as, routine test, as per IS 2026:1977 2. The contractor/manufacturer shall furnish original MILL certificate (paid voucher and test certificate) of the CRGO manufacturer. 3. The manufacturer / contractor shall furnish the diameter of LV and HV copper winding and its total resistance. The stray losses shall be specified in percentage terms. The percentage of No load and full load losses shall be as per IS 1180 of 2014 Part 1 (energy efficiency level 2). 4. The contractor shall get the approval of GE for the make of the transformer they plan to procdure.
Item No. 95.00 Contd.... 5. Prior to manufacturing the general arrangement drawing design detail of the transformer shall be got approved from GE. 6. Separate neutral bushing shall be brought out for earthing. . 7. Necessary foundation/PCC platform and 1.50 meter height channel fencing shall be provided as per manufacturer's recommendation and quoted rate for the transformer shall be deemed to be inclusive of the cost for the same. 8. Necessary chain link fencing with iron posts with clear min.1050 mtr space from the foundation should be provided for a height 2.00 mtr with a suitable gate and applying two coats of zink oxide primer. 9. Precommissioning test by EI/SEI will be carried out and record maintained. The contractor will be responsible for the assignment of testing and all the equipment testing material will be arranged by the contractor at no extra cost.
Supply and erecting steel tubular swaged poles complete with cast iron base plate final taper plug, bolts, nuts and screws, type 410 SP-55 (11.0 mtr long) including painting with two coats of black bituminous paint externally (upto planting depth) and two coats of aluminium paint over a coat of Red oxide primer (externally from top of coping) complete all as specified and as directed. Note- Earthwork & PCC shall be measured and paid seperatly)
Supply and fixing HT 11 KV outdoor type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 12 insulators of rating upto 200 Amps including DO fuse set complete all as specified and as directed.
Supply and fixing disc insulator, porcelain, vitreous, 145 mm high and 225 mm dia ball and socket type white, brown or green insulator two-in-series assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified.
Supply and fixing lightening arrestors expulsion type complete with all fittings, transmission class, discharge capacity of 65 KA for HT 11 KV, station class complete all as specified.
M&L for drawing aluminium conductor (Weasel type), steel reinforced of any size conductor including fixing by binding wire and provision of jumpers etc. complete all as specified.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 Sqmm complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.5 core 400 Sqmm complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.5 core 150 Sqmm including taking out old cable of size 150 Sqmm any core complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.5 core 120 Sqmm including taking out old cable of size 120 Sqmm any core complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.5 core 95 Sqmm including taking out old cable of size 95 Sqmm any core complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.5 core 35 Sqmm including taking out old cable of size 35 Sqmm any core complete all as specified and directed.
Supply and fix cable jointing Kit for 11 KV earthed grade cable for outdoor termination heat shrinkable joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Supply and fixing galvanised stay wire of stranded 7/1.6 mm for HT pole complete all as specified and directed.
Supply and fixing stay assembly, complete with accessories as shwon in electrical plate No 1 of SSR having stay rod of diameter 20mm complete with accessories as shown in electrical plate No 1 complete all as specified and directed. (Note - Loop insulator, stay clamps, stay wire, excavation & concrete shall be measured seperately under respective items)
S&F anti-climbing device, spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
Supply and fixing loop type insulator, vitreous porcelain, white, brown or green with overall dimensions 65 x 65 x 90 mm, having 16 mm clearance of hole completre all as specified and directed.
Supply and fixing pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified.
Supply and fixing danger notice plate of 1.60mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in single red colour and fixed with M.S clamps, bolts and nuts of approved size for HT 25x20 cm size complete all as specified and directed.
Supply and fixing double compression copper stainless steel gland for fixing armoured cable in panel of size 400 sqmm all complete as specified and directed.
Supply and fixing double compression copper stainless steel gland for fixing armoured cable in panel of size 150 sqmm all complete as specified and directed.
Supply and fixing double compression copper stainless steel gland for fixing armoured cable in panel of size 120 sqmm all complete as specified and directed.
Supply and fixing double compression copper stainless steel gland for fixing armoured cable in panel of size 95 sqmm all complete as specified and directed.
Supply and fixing double compression copper stainless steel gland for fixing armoured cable in panel of size 35 sqmm all complete as specified and directed.
M&L cement concrete for PCC type C-2 (1:2:4) 12.5 mm graded stone aggregate for copping of pole including necessary form work and forming neat finish surface complete all as specified and directed.
M&L for plain cement concrete (1:4:8) type D2 (using 40 mm graded aggregate) as in foundation filing and mass concrete complete all as specified and directed.
M&L for plain cement concrete (1:3:6) type C2 (using 40 mm graded aggregate) as in foundation filing and mass concrete complete all as specified and directed.
M&L for Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 300 KVAR with suitable rating incoming MCCB with 8 steps (1x75+3x50+2x25+1X15+1X10) complete all as specified and directed.
Supply installation, commissioning and testing including providing all necessary electrical connection, LT feeder panel board (CPRI Approved), outdoor type, double door, compartmentlaised type, factory made out of 3.15 mm thick MS sheet of size 1.8m (height) x 1.5 m (width) x 0.6 m (depth) having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 nos legs 0.5 meter length with cable entry and exit circular hole with cable gland & gasket at bottom complete including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitereous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc complete and comprising of the following accessories including necessary excavation work for taking out cable loop and refilling the trenches all as directed. BUS BAR CHAMBER (a) Bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid anodized copper bus bars, rated 1500 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - SET OF 4, 1 No.
Item No. 127.00 Contd.... INCOMER (a) LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with air circuit breaker, overload protection, no-volt release with necessary CTs, meter and cable boxes of rating upfo 1000 Amps - 01 NO OUTGOING FEEDERS (a) MCCB 200A Fixed type, 415 Volts 3 pole, 36 KA - 03 No (b) MCCB 250 A Fixed type, 415 Volts 3 pole, 36 KA - 02 No (1 No Out going & 1 No Spare) INDICATING DEVICES (a) LED Indicating lamps for Main Supply indicating 'R', 'Y', 'B' - Set of 3 (Qty - 05) (b) Digital multifunction meter with accuracy 1.0, suitable to measure V,I,P,KWH, ,PF,KVAH, KVAR etc - 05 Nos.
Supply installation, commissioning and testing in replacement including providing all necessary electrical connection, LT feeder panel board (CPRI Approved), outdoor type, double door, compartmentlaised type, factory made out of 3.15 mm thick MS sheet of size 1.5m (height) x 1.5m (width) x 0.5m (depth) having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 nos legs 0.5 meter length with cable entry and exit circular hole with cable gland & gasket at bottom complete including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitereous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc complete and comprising of the following accessories including necessary excavation work for taking out cable loop and refilling the trenches all as directed. BUS BAR CHAMBER (a) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid anodized copper bus bars, rated 500amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - SET OF 4, 1 No.
Item No. 129.00 Contd.... INCOMER (a) MCCB 250A Fixed type, 415 Volts 4 pale, 36 KA - 01 No (In coming) OUTGOING FEEDERS (a) MCCB 100A Fixed type, 415 Volts 4 pole, 25 KA - 05 No(4 No Out going & 1 No Spare) (b) MCCB 63 A Fixed type, 415 Volts 4 pole, 25 KA - 01 No Out going INDICATING DEVICES (a) LED Indicating lamps for Main Supply indicating 'R', 'Y', 'B' - Set of 3 (Qty - 05). (b) Digital multifunction meter with accuracy 1.0, suitable to measure V,I,P,KWH, ,PF,KVAH, KVAR etc - 06 Nos.
Supply installation, commissioning and testing in replacement including providing all necessary electrical connection, LT feeder panel board (CPRI Approved), outdoor type, double door, compartmentlaised type, factory made out of 3.15 mm thick MS sheet of size 1.2m (height) x 1.5m (width) x 0.6m (depth) having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 nos legs 0.5 meter length with cable entry and exit circular hole with cable gland & gasket at bottom complete including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitereous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc complete and comprising of the following accessories including necessary excavation work for taking out cable loop and refilling the trenches all as directed. BUS BAR CHAMBER (a) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid anodized copper bus bars, rated 400amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - SET OF 4, 1 No.
Item No. 131.00 Contd..... INCOMER (a) MCCB 200A Fixed type, 415 Volts 4 pale, 36 KA - 01 No (In coming) OUTGOING FEEDERS (a) MCCB 100A Fixed type, 415 Volts 3 pole, 25 KA - 05 No(4 No Out going & 1 No Spare) INDICATING DEVICES (a) LED Indicating lamps for Main Supply indicating 'R', 'Y', 'B' - Set of 3 (Qty - 05) (b) Digital multifunction meter with accuracy 1.0, suitable to measure V,I,P,KWH, ,PF,KVAH, KVAR etc - 05 Nos.
M&L Earthing complete with galvanized steel earth plate electrode 600mm x600mm x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected with galvanized strip of size 32x6mm by means of steel bolts, nuts, check nuts and washer, of galvanized earth wire protected by 40mm bore medium grade galvanised iron pipe and other end onnected io earthing test point including funnel with watering pipe of 20mm bore light grade galvanised iron wire mesh charcoal or cock end common salt in alternate layer of 15cm (compacted thickness) all around earth electrode with concrete earth pit in PCC (1:3:6) type C-1, 50mm thick precast RCC 1:2:4 nominal mix cover slab of size 450mmx450mm reinforced with 8mm dia TMT bar 10cm C/C and suitable handle of 10mm dia round bar including necessary execavation, earth work in soft / loose soil and deposited soil to a distance n.exc 50 M and necessary testing complete all as shown in electrical plate No 3 of MES Shedule Part -l complete all as specified and directed.
S&F galvanised iron strip 32 x 6mm buried in ground with saddles and fixing scréws etc for roof conductors and down conductors above ground, complete all as specified and as directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and as directed.
M&L for boring of holes carefully under road / pavement / hard standing by trenches using ultra sound technique and necessary machine without damaging the existing road and getting out in any type of soil and disposal of soil to a distance not exceeding 50 m from the site of work complete all as specified and as directed.
S&F Galvanised Iron pipe 80mm bore (dia) ‘Light Grade" for protection of UG cable, laid in floors/ Road crossing, fixing to pole with mild steel clamps, nuts, Bolts etc complete all as specified.
M&L ready made cable route indicator (ISI marked) made out of cast iron rod & plate suitable for LT under ground cable embeded in ground enroute of cable duty engraved with cable type including necessary excavation and earthwork & PCC complete all as specified and directed.
M&L ready made cable route indicator (ISI marked) made out of cast iron rod & plate suitable for HT under ground cable embeded in ground enroute of cable duty engraved with cable type including necessary excavation and earthwork & PCC complete all as specified and directed.
M&L for laying of stone aggregate of grading 20-40mm size in the substation complete all as specified.
Note:- Schedule of cedit (Sch 'A' Part- II) amount of Rs 1,74,307.00 shall be deducted from the total quoted amount of BOQ.
M/s Dhruv Enterprises
VARNI BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .