Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53,689Accepted-AOC 676301 | MALAPPURAM | KERALA | 676301 | L1 | Accepted-AOC l1 accepted | |
| 2 | Rejected-Technical KADAVATH PUVANITHI VEEDU B P ANGADI TIRUR 676102 | TIRUR | MALAPPURAM | KERALA | 676102 | - | Rejected-Technical L1 ACCEPTED | |
| 3 | Rejected-Technical | - | Rejected-Technical L1 ACCEPTED | |
| 4 | Rejected-Technical | - | Rejected-Technical L1 ACCEPTED |
| Sl No | Description | Qty | Unit | SUJEESH K L3 | KP ABDUL RASHEED L2 | MUNEER M L4 | AK ELECTRICALS L1 |
|---|---|---|---|---|---|---|---|
| 1.00Electrical | |||||||
| 1.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 4 | point | 1,500 ₹6,000 | 1,392.85 ₹5,571.4 | 1,472 ₹5,888 | 1,220 ₹4,880 Lowest |
| 1.00 | 1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | 1 | point | 1,600 ₹1,600 | 1,483.41 ₹1,483.41 | 1,568 ₹1,568 | 1,329 ₹1,329 Lowest |
| 1.00 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire | 55 | metre | 200 ₹11,000 Lowest | 221.3 ₹12,171.5 | 233 ₹12,815 | 236 ₹12,980 |
| 1.00 | 1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 12 | metre | 290 ₹3,480 | 261.31 ₹3,135.72 Lowest | 276 ₹3,312 | 279 ₹3,348 |
| 1.00 | 1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 20 | metre | 350 ₹7,000 | 317.34 ₹6,346.8 Lowest | 336 ₹6,720 | 333 ₹6,660 |
| 1.01 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 15 | metre | 100.6 ₹1,509 | 90.32 ₹1,354.8 Lowest | 96 ₹1,440 | 95 ₹1,425 |
| 1.01 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | 6 | metre | 140 ₹840 | 130.33 ₹781.98 Lowest | 138 ₹828 | 135 ₹810 |
| 1.01 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | 3 | each | 500 ₹1,500 | 452.93 ₹1,358.79 Lowest | 479 ₹1,437 | 475 ₹1,425 |
| 1.01 | 1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). | 1 | each | 700 ₹700 | 645.37 ₹645.37 | 683 ₹683 | 600 ₹600 Lowest |
Tender Value
₹59,845
EMD Value
₹1,496
Closing Date
7 Oct 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer
The Assistant Engineer, LID and EW LSGD, Tirur Municipality
Annual Plan-Electrification of Anganvady hall wiring in ward 6 at Thirur Muncipality-Proj No-S0136/27-General Electrical Work
2026_LSGD_872757_11
02/Etender/2026-27/item rate
Open Tender
Electrical Works
Item Rate
150 days
Tirur municipality
Please refer Tender documents.
10 documents required · 10 mandatory
₹555
Yes
₹1,496
Yes
24 Nov 2026
26 Sept 2026
9 Oct 2026
26 Sept 2026
7 Oct 2026
26 Sept 2026
30 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrical | |||||
| 1.001 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 4 | point | - | - |
| 1.002 | 1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | 1 | point | - | - |
| 1.003 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire | 55 | metre | - | - |
| 1.004 | 1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 12 | metre | - | - |
| 1.005 | 1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 20 | metre | - | - |
| 1.006 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 15 | metre | - | - |
| 1.007 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | 6 | metre | - | - |
| 1.008 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | 3 | each | - | - |
| 1.009 | 1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). | 1 | each | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1480990.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.30 MB
estimate.pdf
Other Document • 0.06 MB
ipact.pdf
Other Document • 0.17 MB
viewsbd.pdf
Other Document • 1.63 MB
viewnit.pdf
Other Document • 0.02 MB
fot.pdf
Tender Documents • 0.20 MB
BOQ_1480990.xls
BOQ • 0.31 MB
affd.pdf
Other Document • 0.26 MB
prelim.pdf
Additional Documents • 0.28 MB
epay.pdf
Other Document • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .