Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC CHARUVILA PUTHEN VEEDU KOTTUKAL NELLIMOODU P O TRIVANDRUM 695524 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695524 | L1 | Accepted-AOC Agreement executed by SURESH T on 26.03.2022 | |
| 2 | L2₹3.7 L+₹44,405 (13.5%)Rejected-AOC RAGHAVA VILASAM KANNANKODE AYIRAKUZHY MANCODE KOLLAM 691559 | AYIRAKUZHY | KOLLAM | KERALA | 691559 | L2 | Rejected-AOC Agreement executed by SURESH T on 26.03.2022, hence 2nd lowest EMD may be released | |
| 3 | Rejected-Technical | - | Rejected-Technical L3 |
Tender Value
₹3.9 L
EMD Value
₹9,700
Closing Date
28 Feb 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Thiruvananthapuram Corporation 695033
1742/22 (15) Providing re-electrification in the Ponnara UPS in Muttathara Ward in under City Corporation Thiruvananthapuram.
2022_LSGD_476780_9
EE(C)/TENDER/2021-22 (24)
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
Thiruvananthapuram Corporation
Please refer Tender documents.
7 documents required · 7 mandatory
₹800
Yes
₹9,700
Yes
12 Apr 2022
22 Feb 2022
2 Mar 2022
22 Feb 2022
28 Feb 2022
22 Feb 2022
60 days
Amount
90.2.1.1 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade, and continous earthing with 14 SWG copper earth, required quantity of copper earth socket, brass bolt and nuts crimping/soldering etc complete with suitable size metal switch boxes modular type metal switch boxes modular type frond plate (white ) etc.upto and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switches and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.(Group B) modular accessories
Single control light point with 6A, 3 plate ceiling rose
90.2.1.2 Twin control light point with 3plate ceiling rose
90.2.1.3 Single control light point with out ceiling rose
90.2.1.4 Single controll ceiling fan point with 6A.3 plate ceiling rose and with socket typepped electronic regulator
90.2.1.5 Call bell point with piano type 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end
90.2.1.6 Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
90.2.1.8 Independent plug
1,56 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing two numbers 3 pin 5/6 A modular socket outlets and 2 nos 5/6 A modular switches connections etc. as required.
Dismantling of ceiling fan and painting the same with one or more coats of spray painting with synthetic enamal paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required.
9.3.20.3 Supply & installation of light fittings on TW round block supply conveyence installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamp etc, directly on wall or ceiling with PVC round block neatly painted to suit the fittings and giving connection with required length of 16/0.20mm 3 core coper conductor flex wire conforming to relevant ISS and giving connections as required. 1200mm 1x20W LED lamp with box type fixture
90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slabas per IS 732 as required.
Supply and fixing the following types of superior quality 250V AC call bell on existing MS box and giving connections with required length of 3 core 16/0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire coforming to relevent ISS or with the etended orginal wiring earthing the MS box and making good the surface as required Musical bell with bird sound
90.4.5.2 Supply conveyance, installation, testing and commissioning of ceiling fan of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mmPVC insulated and PVC sheathed 650/1100 V grade 3 core round copper conductor flex wire or with extended orginal wiring etc.as required
1200mm sweep (category B) 5 star rated
MR 1193 400 mm sweep wall mounting fan
Supply and drawing 650/1100V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part 1 1990 in the existing surface/recess conduit as required including giving necessary connections of the following sizes
90.6. 4. 12 1.50 sq mm 2 run
90.6. 4. 13 1.50 sq mm 3 run
90.6. 4. 14 1.50 sq mm 4 run
90.6. 4. 16 1.50 sq mm 6 run
90.6. 4. 22 2.50 sq mm 2 run
90.6. 4. 34 4.00 sq mm 4 run
1.21.1 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed coduit . as required.20 sq mm
1.21.2 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed coduit . as required.25 sq mm
1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface/ recess including providing and fixing 6 pin 5/6 and 15/16 amps modular socket outlet and 15/16 amps modular switch connection etc. as required.
2.8.6 Supplying and fixing following pre wired TP&N MCB distribution board of steel sheet for 415 Volts on surface/ recess complete with loose wire box, terminal connecters for all incoming and outgoing circuits duly pre wired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar neutral link earth bar detachable gland plates interconnections powder painted including earthing etc.as required (but without MCBI/RCCB/Isolator) 6 Way(4+18) Double door
Supply and fixing following way horizontal type 3 pole and neutral sheet steel MCB ditribution board 415 V on surfce / recess complete with tinned copper bus bar, neutral bus bar, earth bar, DIN bar, interconnections, powder painted including earthing etc. as required. (But with out MCB/ RCCB/ Isolator. 4 way(4+18 ) double door
2.13 2 Supplying and fixing following rating 4 pole 415V isolator in the existing MCB DB complete with connections testing and commissioning etc. as required.63 A
Supply and fixing following ratings 4 pole (three phase and neutral) 415V residual current circuit breaker (RCCB) having a sensityvity current up to 300mA in the existing MCB DB complete with connections testing and commissioning etc.as required 63A
2.10.2 Supplying and fixing 5A to32A rating 240/415V "C" curve MCB for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required single pole
mr 1183 36/40W,4000 lumen LED IP66 street light fitting with aluminium housing stove enameled CRCA sheet steel reflector cover acrylic cover complete with THD<10% PF >0.98 RoHS compliant duly wired up for use on 230V AC supply.
Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9 W CFL to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required.
1.36 Supply and fixing brass batten / angle holder including connection with 10W LED bulb as required.
5.4 Earthing with GI earth plate 600x600x6mm thick including accssories and providing masonry enclosure with cover platehaving locking arragement and watering pipe of 2.7m long etc. with charcoal/ coke and salt as required.
Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required
300 x 300 x 6 mm cast iron gully trap with covering
Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required.
2 x 25 x 3 mm GI strip
Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.
25 x 3 mm GI strip
Supply and drawing bare copper conductors of the following sizes along with wiring cables and giving connections etc as required
2.00 mm copper conductor (6 SWG)
3.15.00 mm copper conductor (14SWG)
Supply and laying bare earthing conductors of the following sizes laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil).
3.15.00 mm copper conductor (14SWG)
Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of folowing size suitable for fixing KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.
S & F switch disconnector fuse unit complete with handle assembly, door inter lock and padlocking arrangement of the following ratings. 63A
or Supply and fixing the following accessories in the existing meter board and giving connections etc.63A 415V DIN type fuse base
63A 415V Backelite fuse fittings
63A 415V 2 way neutral link mounted on DMC/SMC base
Amount remitted to KSEB for regulerizing the additional load (actual amount will be reimpersed on production of original receipts)
SHINU P S
R.Mohanan
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_684329.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .