Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹84.7 LAccepted-AOC | L-1 | Accepted-AOC LOWEST | |
| 2 | L-2₹1.0 Cr+₹18.9 L (22.4%)Rejected-Finance KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L-2 | Rejected-Finance HIGHEST |
Tender Value
₹65.2 L
EMD Value
₹1.3 L
Closing Date
18 Sept 2019, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Division PWD B and R Br., Ambala Cantt
Up-gradation of Civil Hospital at Ambala Cantt. from 100 Bedded to 200 bedded in Ambala Distt (Pdg. Internal EI only).
2019_HRY_102749_1
PWD/Elect-KNL/Elect-AMB/16442
Open Tender
Construction Works
Works
180 days
Ambala
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
Executive Engineer, Elect. Division PWD B and R Br
₹1.3 L
28 Jul 2021
9 Sept 2019
20 Sept 2019
9 Sept 2019
18 Sept 2019
9 Sept 2019
Amount
( a )Main Switches Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections. Triple pole switch with neutral link 32 amp. 415 Volts. HSR No.31.12(a) (xiv) Cat-B
Triple pole switch with neutral link 63 amp. 415 Volts. HSR No.31.12 (a) (xv) Cat-B
( c )Moulded case Circuit breakers. Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. 15 amp.to 60 amp. 415 V ,10 KA 3-phase. HSR No.31.12 c (i)
100 amp.to 220 amp.415 V,10 KA 3-phase. HSR No.31.12 c (ii)
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. Size 40 mm x 40 mm x 6 mm. HSR No.31.13(ii)
M.S.Sheet . Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide. HSR No.31.14 (i)
(L)Miniature Circuit Breaker and Isolator. Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. Miniature circuit breakers of 9 KA breaking capacity. SP MCB of 9 KA breaking capacity 6 amp. to 32 amp. HSR No.31.17a) (ii)
TP MCB of 9 KA breaking capacity 40 amp. to 63 amp. HSR No.31.17(a) (iii)
TPN MCB of 9 KA breaking capacity 40 amp. to 63 amp. HSR No.31.17(a) (iii)
(M)Supply and erection of Fittings and Accessories. Bakelite angle / straight button holder large size. HSR No.31.18 (xi)
Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point. HSR No.31.18 (xxiv)
Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job. . HSR No.31.18 (xxvi)
(O)Erection and carriage of fans.. Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work. HSR No.31.20 (i)
Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to he site of work. HSR No.31.20 (iii)
Making suitable hole in the wall upto 450 mm sweep exhaust fan including finishing the same and fixing of wire mesh duly fixed with Deodar wood frame of section 40 mm x 25 mm thick. HSR No.31.20 (v)
Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required:- Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness on surface. HSR No.31.21 (xv)
Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness on surface. HSR No.31.21 (xvi)
Heavy guage welded conduit pipe 32 mm dia 1.60 mm thickness on surface. HSR No.31.21 (xvii)
Supply and erection of PVC pipe of 6 kg. pressure laid 1 metre below ground level complete including digging refilling of the trench with jointing etc. PVC pipe 120 mm dia. HSR No.31.21(xxx) (a)
PVC pipe 80 mm dia. HSR No.31.21(xxx) (b)
(Q) Earthing Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required . HSR No.31.22(i)
Extra for using salt and charcoal / coke for pipe earth electrode as required. HSR No.31.22(ii)
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as equired. HSR No.31.22(iii)
Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) comlete as equired. HSR No.31.22(iv)
Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode. HSR No.31.22(v)
Pdg. and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required . HSR No.31.22(x)
Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required . HSR No.31.22(xi)
Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required . HSR No.31.22(xii)
Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material. HSR No.31.22(xiv)
Pdg. and fixing 25 mm x 5 mm GI strip on surface or in recess for connections etc. as required with all labour and material. HSR No.31.22(xv)
Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required . HSR No.31.22(xvi)
(b) Lightning conductor Galvanised iron. Excavation of earth pit 180 cm. round at top and 90 cm. at bottom 4.5 metres deep and refilling the same in plains including supply of necessary charcoal / coke and salt mixture. HSR No.31.24 (ii)
Supply and erection of 60 cm. X 60 cm. X 6 mm thick galvanised Iron plate including nacessary bolts and nuts to G.I. tape . HSR No.31.24 (iv)
Pdg. Standard watering tank including down pipe and C.I. cover with locking arrangement etc. HSR No.31.24 (v)
Supply and erection of 20 mm x 3 mm thick lightning conductor G.I. tape fixed with suitable G.I. stapples of same size. HSR No.31.24 (vi)
Supply and erection of G.I. tape 32 mm x 6 mm thick from earth electrode directly in ground and surface , fixed with G.I. stapples of same size. HSR No.31.24 (vii)
Supply and erection of 25 mm dia meter 1.5 metre long lightning G.I. tube rod tapered in to a point at the top with 16 cm. X 16 cm x 3 mm thick G.I. base plate and necessary nuts and bolts with washer. HSR No.31.24 (viii)
Supply and erection of underground cable, loose in existing pipe or trenches complete with necessary connections . 50 Sq. mm 3.5 Core Cable . HSR No.31.26 (xxvii)Ard.
150 Sq. mm 3.5 Core Cable . HSR No.31.26 (xxxi) Ard.
185 Sq. mm 3.5 Core Cable . HSR No.31.26 (xxxii)Ard.
240 Sq. mm 3.5 Core Cable . HSR No.31.26(xxxiii) Ard.
400 Sq. mm 3.5 Core Cable . HSR No.31.26 (xxxv)Ard.
16 Sq. mm 4 Core Cable . HSR No.31.26 (xI) Ard.
25 Sq. mm 4 Core Cable . HSR No.31.26 (xIi) Ard.
35 Sq. mm 4 Core Cable . HSR No.31.26 (xIii) Ard.
Supply and erection of suitable compression type brass cable glands for underground Cable. 10 Sqmm to 16 Sqmm Cable 2 to 4 Core . HSR No.31.28 (ii)
25 Sqmm to 50 Sqmm Cable 2 to 4 Core. HSR No.31.28 (iii)
120 Sqmm to 185 Sqmm Cable 3 to 3.5 Core HSR No.31.28 (v)
240 Sqmm Cable 3 to 3.5 Core . HSR No.31.28 (vi)
300 Sq mm to 400 Sqmm Cable 3 to 3.5 Core . HSR No.31.28 (vii)
(X)Miscellaneous . Supply of M.S.pipe (B-Class) for suspension rod of ceiling fan including threading if required. Supply and erection of 75 mm x75 mm x 60 mm deep M.S.box for telephone and inter-communication system including 2 pin 5 amp. socket including cost of bakelite sheet . HSR No.31.35 (vii)
Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm . HSR No.31.35 (ix) (d)
35 sqmm . HSR No.31.35 (ix) (f)
120 sqmm . HSR No.31.35 (ix) (j)
185 sqmm . HSR No.31.35 (ix) (l)
240 sqmm . HSR No.31.35 (iX) (m)
400 sqmm . HSR No.31.35 (ix) (o)
(A)PVC Insulated wiring in recessed conduit. Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit pipe. Fan Point - Medium . HSR No.31.36
Fan Point- Long. HSR No.31.36
Light point -Short. HSR No.31.36 (ii)
Light Point - Medium. HSR No.31.36
Light Point- Long. HSR No.31.36
Twin control light point with 2 way 5 amp. single pole switch- Short point. HSR No.31.36 (iii) a
Twin control light point with 2 way 5 amp. single pole switch- Medium point. HSR No.31.36 (iii) b
Twin control light point with 2 way 5 amp. single pole switch- Long point. HSR No.31.36 (iii) c
Call bell point including M.S. box of size 180 mmX100mmx60mm deep for call bell - Medium point. HSR No.31.36 (vi) b
Call bell point including M.S Box of size 180mmx100mmx60mm deep for call bell - Long point HSR No.31.36 (vi) c
3 pin 5 amp. plug point including earthing the 3rd. pin etc. - Short point. HSR No.31.36 (vii) a
3 pin 5 amp plug point including earthing the 3rd. pin etc. - Medium point. HSR No.31.36 (vii) b
3 pin 5 amp. plug point including earthing the 3rd. pin etc.- Long point. HSR No.31.36 (vii) c
3 pin 15 amp plug point including earthing the 3 rd. pin etc.with 4 sq mm PVC insulated Al.conductor cable - Medium point. HSR No.31.36 (viii) b
3 pin 15 amp plug point including earthing the 3 rd. pin etc.with 4 sq mm PVC insulated Al.conductor cable - Long point. HSR No.31.36 (viii) c
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Size 1.5 sqmm (3 / 0.81mm). HSR No.31.40 (i)
Size 2.50 sqmm (3 / 1.05mm). HSR No.31.40 (ii)
Size 4 sqmm (7 / 0.85mm). HSR No.31.40 (iii)
Size 6 sqmm ( 7 / 1.05mm). HSR No.31.40 (iv)
Size 10 sqmm ( 7 / 1.35mm). HSR No.31.40 (v)
Size 16 sqmm (7 / 1.70mm) HSR No.31.40 (vi)
Supply and erection of double door sheet steel enclosures distribution boards suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material requared complete the job in all respect upto the entire satisfaction of the Engineer-in Charge of the work. 4-way, TP & N (Horizontal) (8+12) HSR No.31.41 (iv)
8-way, TP & N (Horizontal) (8+24) HSR No.31.41 (v)
4-way, TP & N (Vertical) (8+12) HSR No.31.41 (vi)
8-way, TP & N (Vertical) (8+24) HSR No.31.41 (vii)
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material requiredto complete the job in all respect to the entiresatisfaction of Engineer-in-Charge of work. 25 mm dia HSR No.31.44(b)
Providing & fixing modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect. 10 amp. 1 way switch HSR No.31.56 (a)
10 amp. 2 way switch HSR No.(b)
20 amp. switch HSR No.(c )
10 amp. Socket HSR No.(d)
16 amp. Socket HSR No.(e)
Bell Push HSR No.(f)
Fan Regulator HSR No.(g)
Call bell Ding-Dong(Monitca) HSR No.(h)
Blinking plate HSR No.(i)
Pdg and fixing GI concealed sheet metal boxes with inner an outer faceplate including concealing the box in wall and fixing in position with inner plate and face plate with all labour & material required for the job complete in all respect. 1&2 Modules HSR No.31.57 (a)
3 modules HSR No.(b)
4 Modules HSR No.(c )
6 Modules HSR No.( d)
8 Modules HSR No.(e)
12 Modules HSR No.(f)
Supply and erection of PVC pipe ISI marked (Medium) recessed in wall/ceiling etc including the cost of PVC bends inspection boxes, iron hooks and cement concrete etc complete in all respect upto the entire satisfaction of engineer-in-charge of work PVC pipe of 32 mm dia HSR No.31.58
Supply, Installation, Testing and Commissioning of Wall/ free standing flooor mounting dust & vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet, required hardware 3 mm thick bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of Zinc/Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/switch wear. Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber Extended solid copper bars up to cable cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The panel will be complete with control wirring (copper) and fuse protection.(only outer area on all sides shall be measured) HSR No.31.63
Supply and Fixing of copper bus bar duly tinned by means of SMC / DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with color coding heat shrinkable PVC insulation complete in all respect. HSR No.31.64
Supply and Fixing of rotary handle for ON / OFF operation of existing MCCB in the LT panel including fixing the same in position with all labour and material to required to complete the job in all respect. Rotary Handle up to 125 Amp.., MCCB HSR No.31.66 ( i )
Rotary Handle above 125 Amp.., MCCB HSR No.( ii )
S/E of mark double walled corrugated(DWC)HDPE pipe laid 1 mtr. Below ground level i/c diging and refilling of earth i/c cost of suitable size socket/ cuppler for HDPE pipe i/c the cost of labour and material required to complete the job in all respect up to the entire satisfaction of EIC of the work. HDPE pipe 63/50mm outer dia/ inner dia. HSR No.31.67 (i)
HDPE Pipe 90/75 outer dia / inner dia. HSR No.(ii)
Supply and erection of module case circuit breaker single pole/ 4 pole on wall /on existing pedestal including bounding to earth and making necessary connection required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 Amp /400 Amp. HSR No.31.69 vii)
Supply and erection of heavy duty 4 pole ON load changeover load breaker switch comprising of switches 63 Amp. to 400 Amp. suitable for operation on 415 V 50 Hz AC supply complete with handle assembly having door interlock & padlocking arrangement on existing panel / including making necessary connections with petty material required to complete the job. 400 amp 4 pole ON load changeover switch HSR No.31.74 v
Supply, Installation, Testing & Commissioning of Compact Air insulated aluminium TPN rising mains over all dimension should be as per standard size of manufacturer. Powder coated in approved color, fabricated of 1.6 mm thick GI sheet with plug in point provision, IP-54 protection, rise of 55 Degree temperature over an ambeint of 40 Degree temprature, alongwith thrust pad, fire barrier, End cover, suitable for 415 Volt 50 Hz AC and 2 No. aluminium earth strip as per IEC 604391 I & II, complete in all respect upto the entire satisfaction Engineer in charge of work. Make-C&S/Seimens/Legrand/Schneider Electric. 250 Amp., 15 KA SC for 1 Second. NS-NS-1 i)
Supply, Installation, Testing & Commissioning of End feed unit with FPMCCB of following size/capacity suitable for compact bar duct as above, complete in all respect upto the entire satisfaction Engineer in charge of work. Make-C&S/Seimens/Legrand/Schneider Electric. 250 Amp., 25 KA, 4 Pole MCCB NS-NS-2 ii)
Supply, instalation Testing and Commissioning of Tap of box with FP MCCB of 25 KA breaking capacity with adjustable thermal and fixed magnetic setting complete in all respect. 32/63 Amp. 4 Pole NS-NS-3 i
100/125 Amp. 4 Pole NS-ii
M/s JSB Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .