Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC | L1 | Accepted-AOC Bidder was technically and financially qualified | |
| 2 | L2₹7.0 L+₹1.2 L (20.8%)Rejected-Finance 3 333 F M P ARCS VENGACHUVADU VAZHAKKULAM P O CHAITHANYA BUILDING SA ROAD KADAVATHRA MUVATTUPUZHA ERNAKULAM 686670 | MUVATTUPUZHA | ERNAKULAM | KERALA | 686670 | L2 | Rejected-Finance Financially not lowest | |
| 3 | L3₹7.0 L+₹1.2 L (21.4%)Rejected-Finance ASWATHY NIVAS MAMPAZHAKARA PERUMPAZUTHOOR NEYATTINKARA TRIVANDRUM KERALA 695126 | THIRUVANANTHAPURAM | KERALA | 695126 | L3 | Rejected-Finance Financially not lowest | |
| 4 | Rejected-Technical T C 17 250 CHADIYARA ROAD POOJAPPURA TRIVANDRUM KERALA 695012 | THIRUVANANTHAPURAM | KERALA | 695012 | - | Rejected-Technical Tender fee not submitted |
Tender Value
₹7.0 L
EMD Value
₹14,030
Closing Date
22 Feb 2022, 4:00 pmClosed
project Engineer cum Estate Officer(I/C)
IISER,THIRUVANANTHAPURAM
Electrical works for providing lights in New Kho-Kho court in IISER TVM campus Vithura, Thiruvananthapuram (Part-1 Supply and installation of poles, light fittings and its associated works)
2022_IISRT_673813_1
IISERTVM/EO/EM/158/37/2021-22
Open Tender
Electrical Works
Item Rate
90 days
IISER
Please refer Tender documents.
4 documents required · 4 mandatory
₹560
IISER,THIRUVANANTHAPURAM
₹14,030
31 Mar 2022
15 Feb 2022
23 Feb 2022
16 Feb 2022
22 Feb 2022
16 Feb 2022
Amount
Supply,installation, testing and commissioning of 9Mtr long GI octogonal/conical pole made of MS steel having having neccesary sections if required as per manufactures design with suitable base plate and necessary single arm each ,min sheet steel thickness 3mm ,suitable for providing 4 Nos 27500 Lumens LED fittings, and all materials required for installation like interconnecting cable with 2Runs of 3C 2.5 sq.mm FR PVC insulated stranded copper conductor flexible cable , bolts, nuts, DIN rail, 16A SP MCB-2 Nos, 32A connectors heavy duty 4way, N.L-2Nos, 3mm thick laminated hylem sheet, Pole earthing, glanding in 3 mm thick M.S. sheet includings connection complete as required and all related works as directed by the EIC. (Pole-Crompton/Bajaj/Klite or Equivalent to suit the existing foundation)
Supply of high-quality integrated LED Flood Light with a minimum system lumen of 44000 Lm and system wattage not more than 400 W with a nominal efficiency 110 lumen/watt (min) using High power LED's, with integrated Peanut Lens shall be mounted on each LED by injection moulding process on PC Cover . The housing should be of non-corrosive high-pressure die-cast aluminum alloy to with stand extreme environments, should have corrosion resistant coating .The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥70 and co-related color temperature (CCT) of 5700K with assymetric/ suitable beam angle. The Ingress protection must be minimum IP 66 with an IK rating of 08. LED used in the luminaire shall be of make of Lumileds, Osram, Nichia, Seoul and CREE & no other make. The Luminaire should have a 10 KV SPD duly bolted in the Luminaire . The luminaire shall be flicker free with a ripple content less than 10 %. the luminare should have PF>0.95 and THD<10%.Luminaire and driver shall be separately BIS approved of same make. Make: Wipro Cat Ref LF20-502-060-57-G4/Philips BVP485 LED 485 CW AWB PSU SPD GR or Equivlent. Led lightfittings have 5years onsite warranty. Equivalent make shall submit dialux report and technical data sheet for approval.
Installation, testing and commissioning of LED type flood light luminaries up to 400 W with mounting bracket etc as required in existing 9 m pole includings required accessories,connection complete as required and all related works as directed by the EIC .
Supply and making end termination with brass compression gland with gland earthing and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE Al. conductor cable of 1.1 KV grade as required.
4 x 6 Sqmm
4 x 4 Sqmm
Supply and fixing of following ways surface/ recess mounting, single pole and neutral, outdoor type IP-65 whether proof MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Fixing, testing and commissioning of following rating RCBO or MCCB as required in existing vertical distribution board including drilling holes in the vertical distribution board, making connections etc as required at incomer.
Upto 63A DP RCBO/MCB
Linsta Services
FI-TEC POWER SOLUTIONS PVT. LTD
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .