| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC BLDG NO XXVIII 378A NORTH CHAMPANOOR ANGAMALI SOUTH P O PIN 683 573 | ANGAMALI | ERNAKULAM | KERALA | 683573 | L1 | Accepted-AOC being lowest | |
| 2 | L2₹34.7 L+₹8.7 L (33.6%)Rejected-AOC THOTTAPALLY HOUSE EMILY P O KALPETTA WAYANAD DT | KALPETTA | WAYANAD | KERALA | 673121 | L2 | Rejected-AOC being not lowest |
Tender Value
₹23.2 L
EMD Value
₹46,400
Closing Date
7 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Fort Kochi
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
AS PER BOQ AND TENDER DOCUMENTS
2021_MES_441835_1
8731/E8/GE Fort Kochi
Open Tender
Civil Works
Item Rate
180 days
Fort Kochi
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE Fort Kochi
₹46,400
Yes
16 Aug 2021
10 May 2021
9 Jun 2021
11 May 2021
7 Jun 2021
24 May 2021
60 days
Amount
Dismanting wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed.
M&L for GI frame work size of grid 605x605 for seamless false ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30 mm and web 27mm fixed to surrownding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15 mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fastners with and including ceiling section (n.exc 1.2 m length)of 0.55mm thickness having curled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting lips,accross the intermediate channel with connecting lips accross the intermediate channel at 457mm centre to centre complete all as specified and directed..
M&L for hangers 6mm dia GI(upto 1200mm length) adjusting level fixed to roof slabs/Truss by means of ceiling cleats made out of GI flat 40x3mm size 60mm long complete all as specified
M&L for providing and fixing Gypsum board 12mm thick in ceiling fixed with screws as per manufacturers instruction complete all as specified and directed.
M&L preparing new surface of ceiling and applying two coats of distemper oil emulsion over a coat of chalk whiting complete all as specified.
Dismantling of Mangalore pattern or similar tiles in roofing bedded in lime or cement mortar.
Dismantling asbestose cement corrugated or semi corrugated sheet in roof covering all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for
Cutting holes in brick walls exc one brick thick walls built in cement mortar for inserting hold fasts,fixing lugs and similar articles and making good the dismantles portion in cement mortar1:3 or in cement concrete 1:2:4 type B1 all as specified and directd.
Dismantling of timber scantilings 40 sqcm and over in section in framed work, in any position.
M&L roof trusses (framed) trussed, purlin, rafter, rails and fastenings and heavy brackets framing (Beam tee, angle, chennel or flat sections) including distace pieces, cleats etc of FE-410-W (Gde E-250)
S&F pre-painted galvalume aluminum zinc coaing GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
S&F pre-painted galvalume aluminum zinc coaing GI based plain sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, eves gutter & Valley gutter, fixed with self tapping screws all as specified and as directed.
Taking down cement plaster of any description from brick or stone walls etc incl railing out joint hacking for key scrubbing down with water etc all as specified and directed.
Demolition of brick masonry built in cement in cement mortar or cement lime mortar .
M & L Pre- cast cement concrete block masonary with solid block Type C-1 1:3:6 (using 20 mm graded stone aggregate) built in cement mortar 1:6 exc 10 cm in width and setting in cement mortar complete all as specified.
M&L for rendering 15 mm thick in two coats (10 mm thick in cement mortar 1:4 and 5 mm thick in cement mortar 1:4) mixed with water proofing compound) on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement.(Note- water proofing compound shall be measured and paid seperately) .
M&L for rending 15 mm thick in cm 1:6, and making surfaces fair and even complete all as specified and directed.
Supply only liquid water proofing admixture of Fosroc chemicals/Pidilite .
M&L for plastering in CM 1:6, 10 mm thick on walls finished even and smooth w/o using extra cement.
Complete removal of existing treatment by scrapping wall complete all as specified and directed.
M&L for two coats of Antifungal paint (Apex ultima Protek of Asian paint or Equivalent in approved Makes) over a coat of Exterior primer (Proffesional pack of Asian paints) over a coat of external wall care piutty n.exc 2 mm thick on new or old prepared plastered external surfaces and including scafoldings and cradles including hoisting and lowering as required with bracing , support complete all as specified.
M&L for preparation of old plasterd surfaces of wall by complete removel of existing treatement and applying two coats of oil emulsion distemper over a coat of primer over a coat of 3 mm thick wall care putty, over 10 cm width or girth complete all as specified and as described.
M&L for preparation of new plasterd surfaces of wall and applying two coats of oil emulsion distemper over a coat of primer over a coat of 3 mm thick wall care putty, over 10 cm width or girth complete all as specified and as described.
Taking down chowkats or frames exc. 1.5 Sqm and n.exc 4.00 sqm each with shutters (without taking off shutters from the frame).
Taking down chowkats or frames not exc. 1.5 Sqm each with shutters (without taking off shutters from the frame).
Supply and fix Aluminium windows casement type (34 mm Series) powder coated aluminium sections with and including 5 mm thick plain sheet glass panes of openable type with rubber lining, Casement type (34 mm Series) sections for mosquito proofing windows with aluminium alloy wire cloth , 0.45 mm nominal dia of wire and average width of aperture 1.40 mm in three panes divided with mullion section sash bars and aluminium standard decco grills 10 mm thick, fixed in with 1.3 mm thick standard aluminium "F" channels etc complete with following sections of HINDALCO or equivalent. (a) "H" frame 44.50 x 34.00 x 2.00 mm Section No 2082 (b) "Z" shutter 34.00 x 44.50 x 2.00 mm Section No 4124 (c) Mullion 57.00 x 34.00 x 25.00 mm Section No 9139 Note:- The rates are inclussive of SS friction hinges grade 304(Eye Max) for aluminium windows , jointing cleats, rubber beading, "U" channels, handles, locking arrangements etc. complete
S&F Aluminium powder coated frame for doors ,windows ,partitions,ventilators with one or more rebates including joining cleat for fixing complete all as pecified
M&L for Prelaminated particle board 9 mm thick interior grade, prelaminated one side with decorative choice lamination & otherside balancing white lamination complete all asspecified .
Fixing only wall lining 40 mm thick of PVC insulated panels having expanded polystyrene (EPS) stuck to 2 mm thick wood grain printed PVC sheet duly fitted into the wall etc complete all as directed by Engineer-in-Charge.
S & F for 40 mm thick lnsulated PVC Wall Lining consisting of PVC Insulated Panels having expanded polystyrene (EPS) stuck to 2mm thick wood grain printed PVC sheet duly fitted into the wall etc. complete all as specified and as directed .
S & F for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.complete all as specified and as directed.
S&F second class hard wood, plain, solid, straight chowkats and frames, wrought, frames, rebated on the solid, put together, glued at joints
S&F second class HW 35 mm thick (stiles & rails as per SSR part-1)plain framed panelled shutters (two panels ) with medium density ,exterior grade marine plywood 9 mm thick supplied and fitted to chowkats .
M&L for preparation of new wooden surfaces over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed.
M&L for preparation of old treated wooden surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
S&F anodised aluminium alloy body door stopper 150 mm size
S&F anodised aluminium extruded handles 150 mm size.
S&F aluminium anodised barrel tower bolts of extruded section 200 mm size.
S/F Aluminium anodised, extruded butt hinges 125mm size.
S/F aluminium anodised bow handle 150 mm long cast type.
S&F aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy.
S&F mild steel hold fasts for fixing chowkats complete all as specified
Demolition of concrete in ground floors n. exc 15 cm thickness
M&L for PCC 1:2:4 type B1 (using 20mm graded aggregate) as in bed blocks for fixing hold fasts.
M&L PCC 40 mm thick, type B-0, 1:2:4, using 12.50 mm graded stone aggreage as in levelling the undulated floor area all as specified and as directed.
Material and labour for joint free non skid ceramic coloured tiles (light shade) any colour and any shade 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. , set and jointed in neat cement slurry and pointed in coloured cement to match over screed bed or bedding layer of mortar in CM 1:6, 15 mm thick for laying floor finishes .etc complete all as specified & directed.
All are as per item No 47 above but skirting including 10 mm thick plastering in CM 1:4 complete all as specified and as directed.
M&L PCC 100 mm thick, type D-2, 1:4:48, using 40 mm graded stone aggreage as in sub base flooring all as specified and as directed.
Material & labour for 75 mm thick PCC ( 1:3:6) type C-2,using 40mm graded stone aggregate as in plinth protection complete with bituminous joints.
S&F drippary curtain rods 25 mm powder coated including ornamental brackets and fixing hooks and rollers,side dooms as per sample complete.
M&L for preparation of new steel surfaces over 10cm width or girth and applying two coats of VX-polymer based anti corrosive paint over a coat of anti corrosive primer complete all as specified.
M & L for Precast RCC Cover slabs type B-1, 1:2:4 (20 mm graded stone aggregate as in slabs of drains including necessary form works.(Reinforcement will be measured and paid seperately).
M&L for TMT bar 10 mm dia and over cut to length, bent to shape reqd incl cranking bending spiray for hooping for colums, hooking ends and binding with and incl mild steel wire (annealed) not less then 0.9mm dia.
M&L plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in coping/kerb complete all as specified.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or taking credit and making good the disturbed surfaces of walls, floors, incl distember matching the existing colour etc.
Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / fan point controlled by one, one way switch 06 Amps.
All as per srl item No 58 here-in-before but one 3 pin socket outlet, 05 Amps, independent with cable 1.5 Sq mm size.
All as per srl item No 58 here-in-before but one 3 pin socket outlet 05 Apms point on the same board with cable 1.5 Sq mm size.
All as per Serial Item No 58 here-in-before but one 3 pin socket outlet, 15 Amps, independent with cable 2.5 Sq mm size.
Supply and fix modular switch, one way, 06 Amps, one module complete all as specified & directed.
Supply and fix modular switch, one way, 16 Amps, one module complete all as specified & directed.
Supply and fix modular socket, 06 Amps, 02/03 pin combined, two module complete all as specified & directed.
Supply and fix modular socket, 06 Amp / 16 Amps, 02/03 pin combined, two module complete all as specified & directed.
Supply and fix in replacement of surface mounted LED tube light fitting four feet long, 20/22 Watt, 2000 lumen, 6500K with IP 20 protection comprises of aluminium extruded channel, extruded aluminium body, integrated electronic driver, etc and all accessories pre-wired including connecting up complete all as directed. Make : Havells Cat part No LUMILINEPLUSBS22WLED865SPCSS or equivalent Cropmpton / Philips
Supply and fix LED down light 2'x2', 42 watts Watts with photo sensor incl driver complete with all accessories prewired and including connecting upwith twin core twisted flexible copper conductor cable with suitable size all as specified incl provision of suitable size of Aluminium frame for mounting the fixture in fall ceiling as per manufacturer recommendation Make: Havells Cat part No VENUSNEOHE2X2R42WLED857SMART PLUS or equivalent Cropmpton / Philips
Supply and fix LED security light 45 W IP 65 connecting upwith twin core twisted flexible copper conductor cable with suitable sizealong with provision of 25 mm dia GI pipe bracket long 4 feet with 135 degree bend fixed on wall with all fixing accessories like clamps nuts bolts etc complete all as specified Make: Havells Cat part No ENDURAPEARLNEOSL45WLED757PASYTOPC or equivalent Cropmpton / Philips
Supply and fix ceiling rose, 3 phase / PVC / polycarbonate, isolated body complete all as specified directed.
Material and labour for wiring for circuit / sub main wiring with 2 x 6.0 Sq mm alongwith 1 x 6.0 Sq mm earth wire of FRLS PVC insulated copper conductor, single core cable drawning into and including rigid non-metallic PVC conduit of 25mm dia or higher complete with all accessories fixed to wall / ceiling including taking out the unserviceable sub main wiring and making good complete all as specified & directed.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 240 volt, 20 Amps complete all as specified & directed.
Supply and fix sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 08 way with 200 Amps rated bus bar and double door complete all as specified directed.
Supply and fixing of MCB, SP, AC, 240 volts of 06 to 32 Amps capacity complete all as specified & directed.
Supply and fixing of MCB, DP, AC, 240 volts of 63 Amps capacity complete all as specified & directed.
Supply and fix sheet metal enclosure distribution board, triple pole and neutral, vertical type, AC, 415 volt, 04 way with 200 Amp rated copper bus bar and double door complete all as specified & directed and comprising of the following (a) MCCB, 125 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete -01 No. (b) MCB, SP, AC, 240 volts of 06 to 32 Amps capacity complete- 12 Nos.
Taking down from mounted position, split air conditioner 1.5 tons of any description incl indoor and outdoor units complete and all mounted accessories , keeping in safe custody till carrying out addition alteration and refixing the same after complete servicing and gas charging and replacement using compatible copper condenser and mounting clamps complete to the satisfaction of Engr in Charge.
Material & labour for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in electrical plate No 3 on serial page No 497 of SSR part I - 2009 and connected to main switch board / Main DB's including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed.
SHAIJAL T M
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .