Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 CrAccepted-AOC BAJUGAON CITY TOWN GOSSAIGAON P O JARAGURI P S GOSSAIGAON DIST KOKRAJHAR PIN 787000 | 787000 | ₹13.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹14.4 CrRejected-AOC CHEGELI POTHER P O JIADHAL CHARIALI P S DHEMAJI DIST DHEMAJI ASSAM | DHEMAJI | ASSAM | 787026 | ₹14.4 Cr | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | M/S MARJIT BASUMATARY L1 | PROBIN DIHINGIA L2 |
|---|---|---|---|---|---|
| 1.00 | CIVIL WORKS
1.1.18 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.
Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. | 922.66 | cum | 376 ₹3.5 L | 489.82 ₹4.5 L |
| 2.00 | 2.1 Fertile topsoil to be stockpiled and reused
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:2.1.1 All kinds of soil | 1,200 | sqm | 119.78 ₹1.4 L | 127.43 ₹1.5 L |
| 3.00 | 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. 2.6.1 All kinds of soil | 2,365.79 | cum | 229.99 ₹5.4 L | 244.67 ₹5.8 L |
| 4.00 | 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 1,943.13 | cum | 284.28 ₹5.5 L | 302.43 ₹5.9 L |
| 5.00 | 2.26 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 2.26.1 All kinds of soil. | 1,000.91 | cum | 116.98 ₹1.2 L | 124.45 ₹1.2 L |
| 6.00 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 180 | cum | 2,419.33 ₹4.4 L | 2,573.76 ₹4.6 L |
| 7.00 | 2.34 Supplying chemical emulsion in sealed containers including delivery as specified. 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% | 240 | litre | 224.9 ₹53,976 | 239.25 ₹57,420 |
| 8.00 | 2.35 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration | 1,200 | sqm | 286.76 ₹3.4 L | 305.06 ₹3.7 L |
| 9.00 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size | 166.63 | cum | 7,081.65 ₹11.8 L | 7,533.67 ₹12.6 L |
| 10.00 | 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | 144 | sqm | 763.06 ₹1.1 L | 811.77 ₹1.2 L |
Tender Value
₹12.9 Cr
EMD Value
₹25.8 L
Closing Date
22 Aug 2025, 12:30 pmClosed
Sri Pranab Kr. Rabha
O/o the Addl. Chief Engineer-cum-Director, PWD, BTC, Kokrajhar.
Construction of CEM Block-C, G-1 with Provision for G-3 Building, BTR, Assam under Grants to BTC for Infrastructure Development Fund for the FY 2025-26. TN_40_01
2025_BTC_46241_1
No.19/PWD/Infra/BTC/2025-26/05
Open Tender
Civil Works - Building
365 days
Kokrajhar
Refer to Tender Documents
4 documents required · 4 mandatory
₹20,000
₹25.8 L
Yes
15 Oct 2025
8 Aug 2025
22 Aug 2025
8 Aug 2025
22 Aug 2025
8 Aug 2025
8 Aug 2025 - 22 Aug 2025
Amount
CIVIL WORKS 1.1.18 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more.
2.1 Fertile topsoil to be stockpiled and reused Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:2.1.1 All kinds of soil
2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. 2.6.1 All kinds of soil
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
2.26 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 2.26.1 All kinds of soil.
2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
2.34 Supplying chemical emulsion in sealed containers including delivery as specified. 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
2.35 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
5.9 Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 Suspended floors, roofs, landings, balconies and access platform.
5.9.4 Shelves (cast in situ)
5.9.5 Lintels, beams, plinth beams, griders, bressumers and cantilevers
5.9.6 Columns, pillars, piers, abutments, posts and struts
5.9.7 Stairs, (excluding landings), except spiral staircase
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.33 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 5.33.1.2 All works up to Plinth level: Concrete of M30 grade with minimum cement content of 350 kg /cum
5.33.2.2 All works above plinth & up to floor V level.: Concrete of M30 grade with minimum cement content of 350 kg /cum
6.47 Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
26.6E Providing and fixing at all height wall panelling with phenol bonded Bamboo Mat board conforming to IS:13958-1994 including providing and fixing to frame work made of 50mm x 50mm hardwood plugs including cutting brick work and fixing in cement mortar and making good the wall etc. and also providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws all complete as per direction of Engineer-in-Charge. 26.6E.212mm thickness
8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 8.2.2 Granite of any colour and shade Area of slab over 0.50 sqm
8.3 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 8.3.2 Granite work
8.4 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
8.5 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.26.86. 6 Frame size 65 x 125 mm
9.21 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
9.24 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 9.24.1 Rectangular or square
9.53 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
9.71.1 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : size- 125x64x2.50 mm
9.97.1 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : size- 300x10 mm
9.99 Providing and fixing 50 cm long aluminium kicking plate of size 100x3.15mm, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete.
9.83 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
9.103 Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
9.127 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 9.127.2 1.0 mm thick
9.147D Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.147D.2 Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
9.7.7.2 Float glass panes; 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
9.7.8 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching beading
10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
16.81 Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx3.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/ bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 3.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work).
11.55 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
11.24 Extra for pre finished nosing to treads of steps of marble/granite stone.
11.25 Extra for marble/granite stone flooring in treads of steps and risers using single length up to 2.00 metre.
8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
8.9.1.2 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. 8mm thick; Granite of any colour and shade
11.41A.3.1 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size; Size of Tile 600 x 600 mm
11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.1.1 Double charge vitrified tile polished finish of size; Size of Tile 600 x 600 mm
11.46 Providing and laying Vitrified double charged tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.11.46.2 Size of Tile 600x600 mm
12.21 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 12.21.1 In 75x75 mm deep chase
12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, 12.45 shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.45.4 Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineerin- charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60
12.52 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.52.2 GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
13.1 12 mm cement plaster :13.1.2 1:6 (1 cement: 6 fine sand)
13.2 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.2 1:6 (1 cement: 6 fine sand)
13.11 18 mm cement plaster in two coats under layer 12 mm thick cementplaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
13.48A Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 13.61.1 Two or more coats on new work
13.83 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applyingadditional coats wherever required to achieve even shade and colour. 13.83.2 Two coats
13.85 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. 13.85.1 With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre
13.85.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
8.14 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 8.14.2.3 50 mm thick Red sand stone - Exposed face machine cut and table rubbed with rough backing.
8.14.4.3 50 mm thick White sand stone - Exposed face machine cut and table rubbed with rough backing.
25.3 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
22.24 Providing and applying integral crystalline (dry shake) of hydrophilic in nature for waterproofing treatment to the RCC structures like basement raft, foundation slab, sewage & water treatment plant slab, warehouses floor, parking structures and water tank base slab etc. sprinkled @0.60kg per sqm or higher as recommended by the manufacturer’s specification over the lean concrete of above cited structures. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 85%, compared control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline dryshakeshall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
22.10 Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or / and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade I (fibre base self finished bitumen felt) six and final courses of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per sqm including preparation of surface, excluding grading, compete.
AUDIO VIDEO WORKS Meeting Room Supply, Installation, Testing & Commissioning of 85 inch 4K UHD interactive flat panal display - Android 14 or latest , 8 GB RAM , 128GB Memory ,20 Touch Point , 450 nits brightness, Commercial Panel 24x7 , Zero Bonding, Type-C connectivity, 9H hardened suffened glass, 40 Watts builtin speakers, screen recorder, wrighting height maximum 1 mm, 60000 hrs or more screen life, reverse screen mirroring featuere, With Built-In HDMI OUT slot.; Multiple signal input HDMI, SPDIF, RS232, AV I/O, Earphone; OSD Language: English, Hindi, Traditional Chinese, Arabic, Spanish, French, Italian, Japanese, Portuguese, Russian etc; feature including: Including Whiteboard, Annotate, Timer, Calculator, Split Screen, Record, Spimer, Screen, Capture, Screen Recorder, Screen Share, Browser, PDF, Reader, Media Player, Screen Cast; with Wall Mount bracket and standered accessories.
Supply, Installation, Testing & Commissioning of customized push pull bracket for above display with standard accessories as required.
Supply, Installation, testing and commissioning of 12X camera, AI-based auto framing mode, SNR CMOS sensor combined with 2D and 3D noise reduction, Streams AV over IP using H.264 and H.265, Control the camera’s functions via USB, Ethernet, RS-485, and RS-232, Supports USB 3.0 and 2.0 interfaces, power: PoE, camera: 4K, Signal to Noise Ratio ≥55dB, Number of Presets: 250 or more, preset Accuracy: 0.1° or better, 3.5mm Audio Interface, Line In, 3.5mm Audio Interface, Mic In, USB PTZ Control: yes, Video Stream: First Stream, Second Stream, Supporting Protocols: TCP/IP, HTTP, RTSP, RTMP, Onvif, DHCP, Multicast.
Supply, Installation, Testing and Commissioning of Ceiling microphone tile with built in 120no. or more Mems microphone, beamforming technology, coverage pattern: customize, Beamforming Range: 100 Hz to 20 kHz, Beam Pointing Accuracy: 0.2 dB or better, Dynamic Range: 20 Hz to 20 kHz, Number of Beams: Up to 10 or more, built in Acoustic Echo Cancellation, Noise Cancellation, Automatic Level Control, Gain Adjust, Mute On/Off, built-in / external amplifier channel: 4 or more, wattage: 15watt or more per channel, built in Dante/P-Link for communication protocol, PoE built in, built in camera tracking funtionality, with requried 90 watt PoE power supply from the same OEM.
Supply, Installation, Testing & Commissioning of Min 6.5" (6.5" LF + 1" HF) two-way coaxial thin edge ceiling loudspeaker, 100V transformer power taps : 24/12/6 W watts, Conical dispersion : 150° or more, impedance : 8, low impedance RMS continous power : 30 watts or more, frequency response (+/- 3dB): 55 Hz - 20 KHz or better, Max SPL(W/m) : 103 dB or better, Sensitivity: 88 dB or better etc. CE Certification or more.
Supply Installation Testing and commissioning of Dante to USB Adapter Supports 2x2 channels of bidirectional audio; Dante Sample Rate: 48 KHz; Bit Depth: 24 Bits/Sample;Built-in support for Dante Audio over IP and AES67 RTP transport formats.
Supply, Installation. testing and Commissioning of Cable Cubby or cable management box with flip-open cover and multiformat cables with Option for HDMI, USB via pass through holes & 2x universal power sockets.
Supply & Laying of 2 core 14 AWG/2.5 Sq mm, Twisted, unshielded Speaker cable with stranded annealed bare copper conductors, Semi-rigid PVC insulation, NEC CL3R, CEC CMG, RoHS compliant.
Supply & Laying of 4 pair shielded/foiled TIA/EIA-568-C Category 6A cable with 23AWG or better Solid annealed bare copper conductors, High-density polyethylene insulation, Flame rated PVC jacket, Overall aluminum/poly foil shield with drain, NEC CMR, CEC CMR FT4, RoHS compliant.
Supply, Installation, Testing & Commissioning of AV cable and connectors.
Conference room Supply, Installation, Testing & Commissioning of System server. Conference Systems of up to 1500 devices, Pre-installed and configured Windows Server OS, software and server to reduce installation time. System server shall be a workstation-based solution that provides high level performance with a remarkably small device. Intel® Core™ i7-12700 Processor (2.1 GHz, up to 4.9 GHz w/Boost, 25 MB cache, 12 core, 65W), 16 GB (2 x 8 GB) DDR5-4800 SODIMM Memory, 256 GB PCIe 4x4 2280 Value M.2 SSD, 2x 1 Gbps Ethernet adapters.
Supply, Installation, Testing & Commissioning of Audio power switching device:- The Digital Audio Powering Switch shall be IP based and responsible for routing, controlling and processing the audio and supplies power to the contribution devices. It shall include an intelligent adaptive acoustic feedback suppressor, echo cancellation and two 5‑band parametric equalizers for optimal speech intelligibility , Completely IP based which is fully compatible to the Ethernet (IEEE802.3) and OMNEO standard, Supports loop‑through connection with cable redundancy ,Standby mode for Power saving , Led on the front to show: green (power on), amber (standby), blinking (no connection to the system)., Ethernet led’s yellow and amber for each socket. , Independent powered sockets; a short circuit on one socket shall not influence the other sockets., Supports hot plug and play system ,Power consumption 530 W ,System supply 48 Vdc ,Total power supply 3x 144 W + 15 W ,Frequency response 30 Hz – 20 kHz ,THD at nominal level < 0.1 % ,Dynamic range> 95 dB ,Signal–to-noise ratio > 95 d B.
Supply, Installation, Testing & Commissioning of Digital completely IP based Table Top Chairman unit with 4.3 inch capacitive touch screen and built‑in NFC reader for fast recognition of participants, Single‑use, dual-use and chairperson can be configured, with gooseneck microphone not more than 480mm in height, Red or green illuminator. Red indicates microphone active, green indicates request for speech accepted, Red or green illuminator. Red indicates microphone active, green indicates request for speech accepted, Two 3.5 mm (0.14 in) headphone sockets stereo jack type, Rotary controls for independent headphone volum control, Built-in Loudspeaker which can be active along with Microphone, Built‑in acoustic feedback suppressor, To prevent eavesdropping and unauthorized access, Information within the system remains confidential through Encryption, Accommodate two headphone connections and rotary volume controls (on the left and right-hand side), LED indicators on device shows, Microphone on state -Red, Possible-to-speak -White, Priority – White (Chairperson only), Request-to-speak -Green.
Supply, Installation, Testing & Commissioning of Digital completely IP based Table Top Dual Use Delegate Unit with gooseneck microphone not more than 480mm in height, Red or green illuminator. Red indicates microphone active, green indicates request for speech accepted, Red or green illuminator. Red indicates microphone active, green indicates request for speech accepted. Single‑use, dual-use and chairperson can be configured, dual request to speak buttons with individual identity, Two 3.5 mm (0.14 in) headphone sockets stereo jack type, Rotary controls for independent headphone volum control, Built-in Loudspeaker which can be active along with Microphone, Built‑in acoustic feedback suppressor, To prevent eavesdropping and unauthorized access, Information within the system remains confidential through Encryption, Accommodate two headphone connections and rotary volume controls (on the left and right-hand side), LED indicators on device shows, Microphone on state -Red, Possible-to-speak -White, Request-to-speak -Green.
Supply & Laying of 2 Mtr Conference connection Cable. The cables shall be used to connect the conference units in daisy chain or to the audio powering switch. It shall provide network communication and power transports in one cable.Material: NHFR (No Halogen Flame Retardant). Conference connector and conference cable should be of same OEM.
Supply & Laying of 10 Mtr Conference connection Cable. The cables shall be used to connect the conference units in daisy chain or to the audio powering switch. It shall provide network communication and power transports in one cable.Material: NHFR (No Halogen Flame Retardant). Conference connector and conference cable should be of same OEM.
Supply, Installation, Testing & Commissioning of Min 6.5" (6.5" LF + 1" HF) two-way coaxial thin edge ceiling loudspeaker, 100V transformer power taps : 24/12/6 W watts, Conical dispersion : 150° or more, impedance : 8, low impedance RMS continous power : 30 watts or more, frequency response (+/- 3dB): 55 Hz - 20 KHz or better, Max SPL(W/m) : 103 dB or better, Sensitivity: 88 dB or better etc. CE Certification or more.
Supply, Installation, testing and commissioning of Quad Channel digital power amplifier, 4 X 120 W @ 100V, Frequency response: 50 Hz - 22 kHz, Signal / Noise: > 100 dB, THD+N (@ 1 kHz): < 0.3% (@ 1/2 rated power), Crosstalk (@ 1 kHz): > 80 dB, Inputs sensitivity: -0.5 to 10.5 dB, Technology : Class-D, Protection : DC short circuit; Over load; over heating; signal limiting; temperature controlled fan, switching mode power supply, CE Certification or more.
Supply Installation Testing and Commissioning of Digital Signal Processor with AEC with a minimum of 4 or more microphone/line inputs that include phantom power. It should also have 4 or more line outputs, with usb audio; The sampling rate should be 48kHz or better and the DSP should be expandable for port expansion. It should have a minimum of 4x4 Dante channels for digital audio transfer and comply with CE, FCC, CA, RoHS, and REACH regulations. The DSP should support control with an app via iOS and Android devices or any third-party control system. Additionally, it should have built-in filters, feedback suppression, and other necessary features as per specifications. single-device(chassis) use is permitted, but the combination of devices is not accepted. Should include surface-mount bracket.
Supply, Installation, Testing & Commissioning of 98" LED display with resolution of 3,840 x 2,160; Brightness: 400nits or more; Response Time: 8ms or better; Color Gamut: 98% or better; Operation: 16/7; should be WiFi 5, Bluetooth 5.2 supported; Bezel Type: 3 Bezel-less; INPUT: HDMI x 3, USB x 2; OUTPUT: Audio optical out; COntrol: RJ45; Safety: 60065, 62368-1; HDR10+ support; in-built speaker: 10W + 10W; Dolby; Remote Control.
Supply, Installation, Testing & Comissioning of 55" 4KUHD resolution LED Display with Android 11, 400 nits brightness, Cortex A55 1.3Ghz processor, Mali G31 MP2, Open GLES3.2, 2 GB DDR RAM, 16 GB Memory, Wifi Type support both 2.4 & 5G Standard, Dolby Audio, Built in Wifi and Cromecast, HDMI CEC, HDMI ARC, Built-in Bluetooth, Hotel mode, Meeting Mode,20W built in speakers, HDMI 2.0 X 3, AV X 1, USB X 2, RJ45 X 1, SPDIF Out x 1,24/7 operational.
Supply, Installation, Testing & Commissioning of customized push pull bracket for above display with standard accessories as required.
Supply, Installation, Testing & Commissioning of Full HD 1080p @ 60 frames per second PTZ Camera with minimum 20X Optical Zoom or better and FoV of minimum 55 degree or better, min 100 Presets.Camera should support simultaneous outputs through Ethernet, HDMI, 3G-SDI,USB & IP streaming or better and can be controlled via RS232 &RS 422 ,USB and Rj45 .Panning angle -170° ~ +170°, Tilting angle -30° ~ +90° . The tilting and panning speed of camera should be minimum 300° per second. Camera should support SRT, FreeD Protocol, PoE and Virtual USB Driver. Camera should support VISCA / VISCAIP / ONVIF protocol, OEM should be CE, FCC, RoHS & BIS Certified complete with standard accessories as required as per tender specifications.
Supply, Installation, Testing and Commissioning of Recording, Streaming & Webcasting Hardware simultaneously, Built-in 4x HDMI & IP Inputs with 4x Line Inputs, 2x HDMI Outputs. The system should be capable to record upto any four inputs simultaneously in a single frame and as well as individual sources simultaneously. Should have minimum 1TB inbuilt storage and can be connected to local NAS storage. The system should be able to support minimum 3 unicast streams.The recorded files should have the option of time and date stamp. OEM should be CE, FCC & RoHS Certified.
Supply, Installation Testing & Commissioning of AV over IP 4K Encoder 4K 60 4:4:4 with 2 x HDMI and 1 x USB-C input and 1 x HDMI output, Auto Video 4K scaler, Switching between the three inputs can be performed automatically using auto-switching (input detect) mode, programmatically via a control system, or through a web browser, HDMI loop- through: display any of the three locally connected sources, standard PoE power (15w or lower), HDMI 2.0 & HDCP 2.2, AES-128/256 Encryption, Audio : Analog Stereo 2- channel, HTTPS Secure API, 802.1x Authentication for Network access control, SSH Network Protocol, , Auto Discover all endpoints on the network, VLAN tagging, LLDP Support, QoS Support, USB 2.0 over IP (KVM), RS- 232 over IP, IR over IP, A single Gigabit LAN Port for PoE Power, 4K UHD Video, Latency not more than 10 ms, High Dynamic range (HDR), future upgradable to Dante / AES 67.
Supply , Installation, Testing & Commissioning of Decoder supports 4K UHD over Gigabit Ethernet, Bit Rates 50 to 800 Mbps, Video Codec: JPEG2000 based visually lossless video compression algorithm, supports: 4K60 4:4:4, AES-128 Encryption, 1x HDMI with HDCP 2.2 & Sacling Supports a wide range of resolutions and rates, up to 4K, Streaming protocols include IP, UDP, TCP, IGMP, and IGMP, Built-in videowall function, Auto Video Scaler, Vlan Tagging , Analog to digital Conversion: 24 bit, 48 kHz; Control: USB 2.0 over IP (KVM), RS-232 over IP, and CEC over IP, Compliance: CE, FCC, RoHS, WEEE.
Supply, Installation. testing and Commissioning of Cable Cubby or cable management box with flip-open cover and multiformat cables with Option for HDMI, USB via pass through holes & 2x universal power sockets.
Supply, Installation Testing & Commissioning of AV controller system should have 4GB RAM and 32 GB memory, should have minimum 2 GPIO/Relay port, should have usb port, LAN Port for control and configuration, it should have GUI control option, operating temp should not be more than 0° C to 50° C or better. complete with standard accessories as required as per tender specifications.
Supply, Installation Testing & Commissioning of Touch Panel with 10” Professional-Grade, Persona-Defined Touch Panel Resolution 1280x800, Aspect Ratio 16:10 landscape, Speakers 2 x 2W, Microphone Dual, Camera 5MP front-facing, with Fixed Focusing Lens, NFC Yes, Supports Read & Write, Ambient Light Sensor Yes, Supports Adaptive Brightness, Proximity Sensor Yes, Supports, Wake on Approach, Power RJ-45, POE 802.3af, 15.4W.complete with standard accessories as required as per tender specifications.
Supply, Installation, Testing & Commissioning of network switch with 24x 1G PoE+, 2x 1G; PoE Ports / Budget : PoE+, 300W or more Budget; Common Layer 2/ Layer 3 switching engine; Fully featured L2/L3/L4 platform for midsize Enterp; Standard or recessed mounting with all ports in the back or all ports in the front with completely standard accessories as required.
Supply, Installation, Testing & Commissioning of Control PC with required license/ software with minimum I5/i7 processor, small factor , 8GB ram, 1 TB HDD, Monitor , keyboard , mouse, audio input complete as required.
Supply, Installation, Testing & Commissioning of 24U Equipment Rack for housing all rack mountable equipments with internal wiring, front glass door; heat dessipation fans; movement wheels, power distribution units etc.,complete with standard accessories as per the tender specifications.
Supply & Laying of 2 core 14 AWG/2.5 Sq mm, Twisted, unshielded Speaker cable with stranded annealed bare copper conductors, Semi-rigid PVC insulation, NEC CL3R, CEC CMG, RoHS compliant.
Supply & Laying of 4 pair shielded/foiled TIA/EIA-568-C Category 6A cable with 23AWG or better Solid annealed bare copper conductors, High-density polyethylene insulation, Flame rated PVC jacket, Overall aluminum/poly foil shield with drain, NEC CMR, CEC CMR FT4, RoHS compliant.
Supply, Installation, Testing & Commissioning of AV cable and connectors.
BORING 23.2 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 23.2.1 All types of soil 23.2.1.1 300 mm dia
23.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge 23.3.3 200 mm nominal size dia
23.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 23.4.3 200 mm nominal size dia
23.8 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge
23.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
23.13 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 23.13.3 200 mm dia
FURNITURE Finnesse Table-6030 1800 x 900 x 740 with Free Standing Ped with Castors for Finnesse Tabl 646H x 390W x 440D
Echo HDU 1200*740*450
Thrill Cushion Fabric HB
Thrill Cushion Visitor Fabric
Pisa 1 seater
Pisa 3 seater
Arbor Coffee Table
Arbor Corner Table
Matrix 3 seater with 2 arms
Reflection 8 Ft Linear 2400W X 725D X 740H
Oxbo MB
Thrill Cushion Visitor Fabric
Rewind sofa 3+2+1
Arbor Coffee Table
Arbor Corner Table
Table T-8
Table T-8
Impress Main Desk 2400 X 1050 X 750 Comprises of Main Desk , ERU and Pedestal
La Sede High Back
Marvel Visitor
MINGLE UNITIZED PLT_6 Seater S 2100 X 1150 X 740
Thrill Mesh
VertexLshpsofaLHSlthrPebbl+DkGrey
Parto 1 seater
Arbor Coffee Table
Arbor Corner Table
Zurina King Bed Wenge
Zurina Bedside Table Bed Wenge
Rewind 2str sofa SLthr Cru Br
Rewind 1str sofa SLthr Cru Br
Arbor Coffee Table
MINGLE UNITIZED PLT_6 Seater S 2100 X 1150 X 740
Thrill Mesh
Finnesse Table-6030 1800 x 900 x 740 with Free Standing Ped with Castors for Finnesse Tabl 646H x 390W x 440D
Thrill Cushion Fabric HB
Thrill Cushion Visitor Fabric
Rewind sofa 3+2+1
Arbor Coffee Table
Arbor Corner Table
MINGLE MODULAR PLT 2350W PT 1 no Mingle Modular 2 seater sharing 6
Kareena Midback
Matrix 3 seater with 2 arms
Finnesse Table-6030 1800 x 900 x 740 with Free Standing Ped with Castors for Finnesse Tabl 646H x 390W x 440D
Thrill Cushion Fabric HB
Thrill Cushion Visitor Fabric
Adria King Bed Imperial Oak
Adria Bedside Tbl Imp Oak
Rewind 3str sofa SLthr Cru Br
Rewind 1str sofa SLthr Cru Br
Arbor Coffee Table
Kareena High Back
BLOCK-C SANITARY INSTALLATIN & WATER SUPPLY 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid
WASH BASIN 17.7A Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
URINALS 17.5 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
CISTERN 17.19 Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete. 17.19.1 10 litre (full flush) capacity-White
C.I. GRATING 17.29 Providing and fixing 100 mm sand cast Iron grating for gully trap
MIRROR 17.32 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 17.32.2 Rectangular shape 453x357 mm
PVC PIPES,BENDS,JUNCTIONS,TEES ETC. Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. Exposed (ii) 110mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
50 mm diameter
Supplying fitting and fixing 45 degree PVC bends of supreme/prince or other ISI approved including joining, fitting........ in exposed surface or in treanch Exposed (ii) 110mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. For soil water pipe (ii) 110mm dia.
For waste water pipe 50 mm diameter
Supplying fitting and fixing PVC plain single tee of supreme/prince or other ISI approved including joining, fitting........ in exposed surface or in treanch 110mm dia pipe
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. For soil water pipe (ii) 110mm dia.
For waste water pipe 50 mm diameter
Supplying fitting and fixing PVC plain single"Y" of supreme/prince or other ISI approved including joining, fitting........ in exposed surface or in treanch 110mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. For soil water pipe 110mm dia.
For waste water pipe 50mm diameter
Supplying fiting and fixing PVC cross ‘T’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. 110mm x110mm
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. For soil water pipe (i) 110mm x110mm
For waste water pipe 50 X 50 mm diameter
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. For soil water pipe 110 mm dia
For waste water pipe 110 mm dia
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. For soil water pipe (i) 110 mm dia
For waste water pipe 50 mm diameter
Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. 110mm x 50 mm
Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified. (a) 110 mm
17.69 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. 17.69.2 Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms
RAIN WATER PIPE 12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 12.43.2 110 mm
SOAP DISH/HOLDER 18.65 Providing and fixing PTMT soap Dish /Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms
TOWEL RAIL 17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
INTERNAL WATER SUPPLY C.P.V.C. PIPES 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 18.7.1 15mm nominal outer dia Pipes
18.7.2 20mm nominal outer dia Pipes
18.7.3 25 mm nominal outer dia Pipes
18.7.4 32 mm nominal outer dia Pipes
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.8.1 15 mm nominal outer dia Pipes metre
18.8.2 20mm nominal outer dia Pipes
BIB COCK Providing and fixing bib cock of approved quality :ORP-10041PM, 2-way with wall flange
Providing and fixing long neck Pillar cock of approved quality :CON-CHR-021K.
18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 18.17.1 25 mm nominal bore :
18.17.2 32 mm nominal bore.
18.18 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.18.2 20 mm nominal bore Each
18.18.3 25 mm nominal bore Each
18.19 Providing and fixing gun metal non- return valve of approved quality (screwed end) 18.19.1 25 mm nominal bore 18.19.1.1 Horizontal
18.19.1.2 Vertical
18.18.2 32 mm nominal bore 18.18.2.1 Horizontal
18.18.2.2 Vertical
18.20 Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 18.20.2 20 mm nominal bore
18.20.3 25 mm nominal bore
18.21 Providing and fixing uplasticised PVC connection pipe with brass unions : 18.21.2 45 cm length 18.21.2.2 20mm nominal bore
HEALTH FAUCET 17.16A Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
WATER TANK 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Sintex make 5000 Litre capacity PCVC Tank
19.7 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19.1 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 19.1.2 150 mm diameter
19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 19.2.2 150 mm diameter S.W. pipe
19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
SITC of Floor Trap with top jali
17.60 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 17.60.1 100 mm inlet and 100 mm outlet 17.60.1.1 Sand cast iron S&S as per IS: 3989
INTERNAL ELECTRICAL Wiring 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.10.3 Group C
1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.9 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
1.14.10 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
1.18 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 1.18.2 Pair
1.21 Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 1.21.1 20 mm
1.22 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 1.22.2 100 mm X 100 mm X 60 mm deep
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 A switch
1.24.2 2 way 5/6 A switch
1.24.3 15/16 A switch
1.24.4 3 pin 5/6 A Socket outlet
1.24.5 6 pin 15/16 A socket outlet
1.24.6 Telephone socket outlet
1.24.7 TV antenna socket outlet
1.24.8 Bell push
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1.27.2 3 Module (100mmX75mm)
1.27.4 6 Module (200mmX75mm)
1.27.5 8 Module (125mmX125mm)
1.28 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1.28.2 3 Module
1.28.4 6 Module
1.28.5 8 Module
1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
1.41 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.45 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
1.50 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1.50.1 Upto 450 mm sweep
1.51 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
1.54 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.54.3 Group C
1.56 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
1.57 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
1.58 Supplying and fixing PVC batten/ angle holder including connections etc. as required.
MCCB, MCB & DB'S 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 2.2.1 100 A, 16 KA,TPMCCB
2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.2 8 way , Double door
2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.4.1 4 way (4 + 12), Double door
2.4.3 8 way (4 + 24), Double door
2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 2.5.2 8 way (4 + 24), Double door
2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
2.10.2 Single pole and neutral
2.10.4 Triple pole
2.10.5 Triple pole and neutral
2.12 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.1 40 A
2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.13.2 63 A
2.18 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.21 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
FANS & FITTINGS 19.1 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
EARTHING 5.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Light Fittings Supply of LED Luminaires BATTEN 20W LED Tube Light of Box Type prewired Indoor Luminaire with Energy Efficient Electronic Ballast, with End Caps Complete as Required. Pride Plus Inverter Batten 20 W 6500 K or equivalent
Supply of Surface/Recessed Mounted Energy Efficient, LED Luminaires 12W LED DOWN LIGHT (Round) Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc as required. ZIVA FLUSH ROUND 12 W 6500K or Equivalent
Supply of Surface/Recessed Mounted Energy Efficient, LED Luminaires 9W LED DOWN LIGHT (Round) Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc as required. ZIVA FLUSH ROUND 9 W 6500K or Equivalent
Supply of 40W LED Recessed Light Fixture Aesthetically designed 2x2 LED Flat panel light which provides soft-light and glare free symmetrical illumination complete with all accessories as required. Make Havells VENUS NEO HE MOD 6500 k or equivalent
Supply of AC 230/250 volts, 50 HZ - 300mm Exhaust Fans Including Providing Nuts, Bolts, Mounting Frame and Other Accessories etc. Complete as Required. Supply of 450mm dia exhaust fan (industrial type)
Supply of 300mm dia exhaust fan (industrial type)
Street Lighting Fideer Pillar Outdoor Type
Light Fittings Supply of Bulkhead Light ( 18 w) Make Havells/ Bajaj or equivalent
Supply of 20KVA ON-LINE DOUBLE CONVERSION TYPE, IGBT based Pure Sine wave UPS system having standard 415 V, 3 Phase Input 3Ph, 400V Output, in-Built Static & Maintenance Bypass Lines. • Back feed protection • Floor Mounted front access • LCD display • Inbuilt Isolation • in-Built Static Bypass • In Built Maintenance Bypass • Emergency Shutdown 12V SMF,120Ah,34nos each total 68nos Exide/Amararaja make battery bank suitable for 60 min back up on your connected load with Rack and accessories. UPS to Battery cable 10M
EXTERNAL ELECTRICAL 9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 9.1.22 3Y X 50 sq. mm (35mm)
9.1.23 3Y X 70 sq. mm (38mm)
POLE ERECTION 11.3 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. 11.3.1 Above 4.5 metre and upto 6.5 metre
11.6 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 11.6.2 40 mm dia
MISC. CIVIL ITEMS 14.4 Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.13 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 14.13.3 100 mm dia
14.14 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 14.14.4 300 mm dia
Cable Laying 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required 7.1.1 Upto 35 sq. mm
7.2 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.2.1 Upto 35 sq. mm
Non DSR Items SITC of external service connection with 250KVA Transformer including HT Line with all acessories such as DP, G.O. Switch, Lightning Arrestor, D.O. Set, G.I. channel, 11 KV Pin insulator, 11 KV Disc insulator, CT/PT set, Metering cabinet, Meter Modem, C.I. earthing pipe, nuts & bolts, pole clamps etc as required for a 250 KVA Sub-Station including making necessary payment to APDCL authority for supervision charge, Labour charge, Meter security etc. The arrangement for charging approval from complete authority is to be done by the contractor as per APDCL
Street Lighting Fideer Pillar Outdoor Type
XLPE CABLE Supply of XLPE AL Armoured Cable 3.5C X 50 Sqmm
3.5C X 300 Sqmm
4C x 16 sqmm
Street Light Supply , Installation, Testing & Commissioning of 100 W LED with complete with pot optic reflector connection with 3x2.5sq.mm single core PVC insulated copper conductor cable from junction box to fixture as required Make Endura Sunbeam of Havells or equivalent
SITC of Led Bollard Light including each fittings and mounting pole 9-12 Watt Make BAMBOO LED BOLLARDof Havells or equivalent
Supply of of Street Light GI Pole 4.5 Meter 60mm dia Pole with Loop wire box and MCB as required compleate in all respect.
Supplying including installation, testing and commissioning of Liquid Cooled caterpillar Diesel Generator set coupled to suitable alternator of 415 V, AC, 3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) EMF/Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the following Technical Specification.. (RANGE FROM 200 KVA TO 1010 KV GENERATOR SET SPECIFICATIONS 1. Model. 2. Prime Power Rating KVA/KW. 125/100 3. No. of Phases. 3 phase. CATERPILLAR ENGINE SPECIFICATION. 1. make: JAKSON/KIRLOSKAR/MAHINDRA/STERLIN WILLSON 2. CPCB NORMS IV 3. No. of Cylinders. 6 4. Aspiration. Natural 5. Cooling. Water Cooled. 6. Governor. Mechanical/Electronic 7. Battery Capacity Rating. 120 AH 2X12 Volt. ALTERNATOR SPECIFICATION. 1. make). 2. Voltage Regulation. +/- 1.0% 3. Insulation. Class - H. 4. Standard Enclosure. IP 23 5. No. of Phases. 3 KVA 125
SEPTIC TANK 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. All Kinds of Soil.
16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
5.33 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 5.33.1 All works upto plinth level 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum
5.22 & 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 & 5.22A.6Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.3 Suspended floors, roofs, landings, balconies and access platform
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : 6.13.1 Cement mortar 1:3 (1 cement : 3 coarse sand)
13.2 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.2 1:6 (1 cement: 6 fine sand)
13.18 Neat cement punning.
HVAC Outdoor Unit Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5
INDOOR UNIT-CASSETTE TYPE Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 3.6TR
Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 1.3 TR
Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. High Static Ductable units (minimum 110 pascal external static pressure) 8TR
SITC of Refrigerant Piping For VRF System Hard drawn copper piping in brazed construciton, complete with O class nitrile rubber insulation, supports/suspenders, as per enclosed specifications. Minimum wall thickness of copper refrigerant pipes shall be as per Copper pipe-ASTM B88, L-Type standard.
Supply, Installation, Testing & Commissioining of Shielded control cum transmission cabling between ODU & IDU 2 X 2C X 1.0 Sqmm Cu Cable in Riggid PVC Conduit duly supported and saddled as per specification & as directed by the consultant. (note : it is important to lay one spare cable for redundancy)
Drain Piping Providing and fixing condensate drain piping with 25mm u-PVC pipe with 9mm thick nitrile tube insulation of following sizes including making wall chases to completely embedd the pipes inside the wall, making good the wall cut and finally finishing with POP to good finish. One end on the pipe will be connected to the indoor unit of the air conditioner /AHUand the other end will be terminated to the nearest apron drain or suitable termination drain pipe complete with all fittings and support etc complete in all respect as directed by the engineer. (Supreme/Ashirvad/Astral)
CCTV Supply, Installation, Commissioning & Integration of Network TDN IR Indoor Outdoor Bullet Camera 1 by 3 CMOS 1 3 MP 3 point 6 mm Fixed 24 IR LEDs PoE H264, Make Honeywell/ Hikvision/ Dlink/ Sony
Supply, Installation, Commissioning & Integration of Network TDN IR Indoor Outdoor dome Camera 1by3 inch CMOS 1point3 MP 2point8 mm Fixed 12 IR LEDs PoE Hpoint264 Make Honeywell/ Hikvision/ Dlink/ Sony
Supply, Installation, Commissioning & Integration of Camera Connection License Make Videonatic or equivalent
Supply, Installation, Commissioning & Integration of 42" Full HD LED Panel Make Samsung / LG
LAN SYSTEM CAT 6 UTP cable
Information outlet CAT 6–Single (I/O, Face plate, SMB)
CAT 6 Patch cord Length 3 meter
CAT 6 Patch cord Length 1 meter
24 port CAT 6 Patch panel
12 u Rack with full accessories
9 u Rack with full accessories
Switch 24 port 10/100/1000 Mbps
17.2.2 Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
17.2.3 Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
17.2.4 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
17.2.5 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
17.2.6 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
17.2.7 Supplying, installation, testing & commissioning of fault isolator complete with base as required.
17.2.10 Supplying, installation, testing & commissioning of addressable fire control module complete as required.
17.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required.
17.2.19 Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
CABLING & WIRING 17.5.2 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
FIRE FIGHTING WORK 18.1 (a) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (c) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (e) Suitable cement concrete foundation duly plastered with anti vibration pads. 18.1.1 2850 lpm at 88 m Head
18.2 (a) Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) (b) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (c) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (d) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. (e) Suitable cement concrete foundation duly plastered and with anti vibration pads. 18.2.1 2850 lpm at 88 m Head
18.3 (a) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) (b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. (c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. (d) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (e) Suitable cement concrete foundation duly plastered and with anti vibration pads. 18.3.1 180 lpm at 88 m Head
18.6 Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 18.6.2 150 mm. Dia
18.7 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 18.7.1 25 mm dia
18.7.2 32 mm dia
18.7.3 40 mm dia
18.7.4 50 mm dia
18.7.6 80 mm dia
18.7.7 100 mm dia
18.7.8 150 mm dia
18.9 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/ Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 18.9.1 Single headed Gunmetal
18.1 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : 18.10.1 Single headed Gunmetal
18.11 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 18.11.1 40 mm dia
18.11.5 100 mm dia
18.11.6 150 mm dia
18.12 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 18.12.6 150mm dia
18.13 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
18.14 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 18.14.4 80mm dia
18.14.5 100mm dia
18.14.7 150mm dia
18.15 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 18.15.2 100mm dia
18.15.3 150mm dia
18.16 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 18.16.1 Gun Metal
18.17 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 18.17.2 40 m
18.18 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 18.18.1 Gun metal
18.19 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 18.19.1 2 way-100 mm dia M.S. Pipe
18.2 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
18.21 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 18.21.1 Pendent Sprinkler
18.22 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
18.23 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 18.23.1 100mm dia
18.24 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 18.24.2 100mm dia
18.24.3 150mm dia
18.25 Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 18.25.2 1000mm
MAGTECH Small Size with min conveyer capacity of 160 kg (Small Size) Product id: 5116877-61129909603 https://mkp.gem.gov.in/x-ray-baggage-inspection-system-per-mha-qr/x-ray-baggage-scanner-small-size/p-5116877-61129909603-cat.html#variant_id=5116877-61129909603
eSSL door frame metal detector dfmd security metal detector for Indoor Single Zone Product id: 5116877-8750350223 https://mkp.gem.gov.in/door-frame-metal-detector/essl-d270-1-ip54/p-5116877-8750350223-cat.html#variant_id=5116877-8750350223
PROBIN DIHINGIA (BID ID -277907)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_73783.xls
BOQ • 0.52 MB
SBD.pdf
Tender Documents • 2.42 MB
Download all tender documents and submit your bid