Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹88.9 LQualified 2ND FLOOR KALOOR BUSSTAND COMPLEX BUS STAND COMPLEX KALOOR BUSSTAND COMPLEX ERNAKULAM KERALA 682017 UDYAM KL 02 0009309 32AAGCS5821G1ZK R M MII STATUS AS NOT VERIFIED | ERNAKULAM | KERALA | 682017 | ₹88.9 L | L1 | Qualified MSE, MII, Category: General |
| 2 | L2₹89.0 LQualified CHENNAI TAMIL NADU 600031 UDYAM TN 02 0011260 | CHENNAI | TAMIL NADU | 600031 | ₹89.0 L | L2 | Qualified MSE, MII, Category: General |
| 3 | L3₹1.1 CrQualified B 3 UDYOG SADAN NO 3 M I D C ANDHERI EAST MUMBAI MAHARASHTRA 400093 | MUMBAI SUBURBAN | MAHARASHTRA | 400093 | ₹1.1 Cr | L3 | Qualified MII |
| 4 | Qualified 11TH FLOOR THE GREAT EASTERN SUMMIT B WING SECTOR 15 CBD BELAPUR RAIGAD THANE MAHARASHTRA 400614 | THANE | MAHARASHTRA | 400614 | - | - | Qualified MSE, MII, Category: General |
| 5 | Disqualified 19 B SHANTIKUNJ 47 OFF OLD NAGARDAS ROAD ANDHERI E MUMBAI MAHARASHTRA 400069 | MUMBAI SUBURBAN | MAHARASHTRA | 400069 | - | - | Disqualified MSE, Category: General |
Updated dates
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
26 Feb 2026, 3:00 pmClosed
Alarm Monitoring System AMS with software as per TTS
Control Panel with 15 inch AMS display and yard supplied equipment in Switchboard Room Bulk head mounted as per TTS
Display of 12 or 15 inch flush mounted on Bridge console display size will be confirmed during detail design as per TTS
Power supply to the Displays is either from individual 230V UPS or from common 24V DC UPS as per Design and TTS
Audio Visual High intensity Flashing Beacon as per TTS
I O cards Digital Analog Digital counter RPM RTD Serial link etc network switches etc as per design and TTS
Alarms Printer as per TTS
UPS with Batteries cum DC distribution Board of suitable capacity refer clause 8.2 as per TTS
Addressable Fire Detection and General Alarm System as per TTS
Combination detector Smoke or heat or rate of rise temperature or UV-IR or optical with base and mountings as per TTS
Heat detector with base and mountings as per TTS
Flame detector with base and mountings as per TTS
Indoor Manual Call points with mountings as per TTS
Outdoor Manual Call points with mountings as per TTS
General Alarm Push button with cover to avoid accidental activation with mountings as per TTS
Sensors or switches for monitoring door status open or close as per TTS
Bilge level Float switches as per TTS
High level Float switches side mounted for Fuel oil Tanks as per TTS
High level Float switches top mounted for Dirty oil Tank as per TTS
Temperature Transmitter as per TTS
Pressure Transmitter as per TTS
Supporting accessories WT junction boxes cable connectors glands interface converters Power supply converter with Auto transfer Switch galvanic isolators
Special cables refer clause-11 as required as per TTS
OBS List of spares and qty as required as per TTS
Special Tools and Commissioning spares as required as per TTS
Class Inspection Charges as LUMPSUM
Documentation Drawings Certificates Installation Operational and Maintenance Manuals as per TTS
Service support for Training Testing commissioning and Trials as LUMPSUM
Any other item not included above however the same would be required for proving the system during commissioning or HATs or SATs as required as per TTS
Man day rate for deputing Service Engineer beyond lump sum cost due to delay beyond control of supplier
8913488
GEM/2026/B/7175454
Two Packet Bid
Alarm Monitoring System AMS with software as per TTS
Andhra Pradesh; Visakhapatanam
Total value wise evaluation
7 documents required · 7 mandatory
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Alarm Monitoring System AMS with software as per TTS | - | - | - |
| Control Panel with 15 inch AMS display and yard supplied equipment in Switchboard Room Bulk head mounted as per TTS | - | - | - |
| Display of 12 or 15 inch flush mounted on Bridge console display size will be confirmed during detail design as per TTS | - | - | - |
| Power supply to the Displays is either from individual 230V UPS or from common 24V DC UPS as per Design and TTS | - | - | - |
| Audio Visual High intensity Flashing Beacon as per TTS | - | - | - |
| I O cards Digital Analog Digital counter RPM RTD Serial link etc network switches etc as per design and TTS | - | - | - |
| Alarms Printer as per TTS | - | - | - |
| UPS with Batteries cum DC distribution Board of suitable capacity refer clause 8.2 as per TTS | - | - | - |
| Addressable Fire Detection and General Alarm System as per TTS | - | - | - |
| Combination detector Smoke or heat or rate of rise temperature or UV-IR or optical with base and mountings as per TTS | - | - | - |
| Heat detector with base and mountings as per TTS | - | - | - |
| Flame detector with base and mountings as per TTS | - | - | - |
| Indoor Manual Call points with mountings as per TTS | - | - | - |
| Outdoor Manual Call points with mountings as per TTS | - | - | - |
| General Alarm Push button with cover to avoid accidental activation with mountings as per TTS | - | - | - |
| Sensors or switches for monitoring door status open or close as per TTS | - | - | - |
| Bilge level Float switches as per TTS | - | - | - |
| High level Float switches side mounted for Fuel oil Tanks as per TTS | - | - | - |
| High level Float switches top mounted for Dirty oil Tank as per TTS | - | - | - |
| Temperature Transmitter as per TTS | - | - | - |
| Pressure Transmitter as per TTS | - | - | - |
| Supporting accessories WT junction boxes cable connectors glands interface converters Power supply converter with Auto transfer Switch galvanic isolators | - | - | - |
| Special cables refer clause-11 as required as per TTS | - | - | - |
| OBS List of spares and qty as required as per TTS | - | - | - |
| Special Tools and Commissioning spares as required as per TTS | - | - | - |
| Class Inspection Charges as LUMPSUM | - | - | - |
| Documentation Drawings Certificates Installation Operational and Maintenance Manuals as per TTS | - | - | - |
| Service support for Training Testing commissioning and Trials as LUMPSUM | - | - | - |
| Any other item not included above however the same would be required for proving the system during commissioning or HATs or SATs as required as per TTS | - | - | - |
| Man day rate for deputing Service Engineer beyond lump sum cost due to delay beyond control of supplier | - | - | - |
Manager, Visakhapatnam, Department of Defence Production, Hindustan Shipyard Limited (HSL), Ministry of Defence, (Dharambir Bharati)
₹80,000
2 Apr 2026
31 Jan 2026
26 Feb 2026
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_8913488.pdf
GEM_BID
2-_tts_2026-01-31-15-23-53_2e96673bbfe0791a19e2490cf58f7a3d.pdf
BOQ
boq_ams_2026-01-31-15-23-53_81383c70edfa97fc76161c3ba3cd798c.csv
BOQ
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
GEM_OTHER • 0.52 MB
gtc.pdf
GEM_OTHER • 0.70 MB
Download all tender documents and submit your bid