Chief Engineer, TTD, Tirupati
O/o Divisional Engineer(Elec)-I Room No.126, Ground floor, T.T.D.Administrative Buildings, K.T.road, Tirupati, Chittoor(Dist), A.P, India
SITC of additional LED Sign Board Sanku, Chakram and Namam at Sri Venkateswara Swamy Temple beside 108' Annamayya statue at Boyanapalli, Rajampeta in Annamayya district
890610
289/DE(Elec.)-I/TTD/TPT/2025-26
OPEN - NCB
Electrical Works
TIRUPATHI
6 documents required · 6 mandatory
₹326
₹19,200
12 Feb 2026
21 Jan 2026
21 Jan 2026
Part - A Work portion
Supply, Installation, Testing and Commissioning of 9mm open LED signage Board of "Chakram" having Size 5' x5' feet having LEDs of 3000 Nos,
Supply, Installation, Testing and Commissioning of 9mm open LED signage Board of " Namam" having Size7'x7'feet having LEDs of 9000 Nos
Supply, Installation, Testing and Commissioning of 9mm open LED signage Board of "Shanku" having Size 5'x5'feet having LEDs of 3800 Nos
Supply, Installation, Testing and Commissioning of 9mm open LED signage Board of SRI VENKATESHWARA SWAMY TEMPLE T.T.D. THALLAPAKA RAJAMPETA ,(ENGLISH) having Size 20'x2.5' feet
The above boards with following detailed specification:
A) 9mm PIXEL LED Specifications (For Shanku, Chakara and Namalu )
Size of LED: 9mm
LED BRAND: BEN Z/EPISTAR / RISHANG
Pixel Pitch: 10mm
PCB Type: Double sided PCB
LED View Angel: 160 degrees
Pixel composition: Single colour
Display colours: Single colour / LED off it will be clear
Brightness: ≥9000 NITS
Viewing angle: Horizontal:≥160°; Vertical:≥150°
OPERARTING VOLTAGE: 12V
Continue operating period : ≥72 hours
Life span: ≥50,000 hours
Max. power consumption: ≤ 12 watt per 100 LEDs
Input voltage: 12V
Operating Environment : Temperature :- 10-- +80°C
Humidity:10% - 90%RH
OPERATING CURRENT: 10mA
Max. power consumption ( Single LED ): ≤ 0.15 watt
Luminous Efficiency (Im/W): 98%
Operating Environment: Temperature:- 10 -- +80°C
Humidity:10% - 90%RH, IP67 GRADING
Product Color: Same color of Light
Weight: 22 grms
WARRANTY TIME: 24 Months From the date of Installation.
B) SMD 2835 SAMSUNG LED SPECIFICATIONS (For Temple Name)
Parameters Size of LED: 7.56mm
LED BRAND: SAMSUNG
PCB Type: Double sided PCB
LED View Angel:130 degrees
Pixel composition: Single color
Storage temperature range: -30°C- +80°C
Electrostatic Discharge Classification : CLASS-1C
Operating Current: 60mA
Max. Power consumption (Single LED ): ≤ 0. 2 watt Luminous Efficiency (Im): 28 lm
Operating Environment : Temperature: - 20 -- +50°C Humidity:10% - 90%RH, IP67 GRADING
Product Colour White
C) ADS 400W 12v 30Amp
SMPS Specifications
Brand: ADS 400W-12-30A
AC input voltage range: 90 – 132VAC/ 180 – 264VAC By Switch
AC inrush current (max.): Cold start, 60A at 230VAC
DC adjustment range:10.2V – 13.8V
Overload Protection : 110 – 140% Rated Output Power
Over voltage protection :13.8 – 16.2 V
Working temperature :-25~+70°C (refer to output derating curve)
Safety standards : UL60950-1 approved
Output Voltage: 12V
Output Current: 29A
Power Rating : 350W
Efficiency: 85%
D) 3mm Thickness Acrylic Sheet Specifications
Acrylic Brand : Mono Acrylic (Imported Sheet)
Thickness of Sheet: 3mm
Cutting Method: Co2 LASER Cutting (130W)
Embossing Thickness: 75mm
Dimension (LxWxH)(mm) : 2419x1209x3
Weight per sqm 3mm ( KGs ): 4.1
E) 3 mm Thickness ACP Sheet Specifications
Brand : EUROBOND
SHEET TICHKNESS : 4mm
SKIN LAYER TICHKNESS: 0.5mm
Weight per sqm 2mm/3mm/4mm ( KGs ) : 2.8/3.8/4.75
Thermal Expansion (Mm/m @ 100°c variance): 2.4
Modulus of elasticity in tension (MPa): 2400
Impact strength (Kg/cm2) : 50
Service temperatures (°c ): -50°c to +90°c
Water absorption by volume (%) : 0.01
Fire Performance : Class 1 (BS476 Pt7) & Class 0 (BS476 pt6&7)
Dimension (LxWxH) (mm) : 2419x1209x3
5. Warranty 2 years (Repair or replacement of defective parts for 2 years from the date of installation).
Supply, fabrication and fixing of MS Tubes & Pipes of all diameters/MS base plates/MS Angles/MS flat/ Bolt & nuts etc., with necessary holes including painting 2 coats of enamel paint over one coat of red oxide and including all labour charges etc., complete
Fright charges at site from one place to another place( in case of not ready to CC plinth at site),Unloading, shifting & positioning of sign board by using crane as per site conditions
Part - B AMC portion
AMC for 3rd Year (Excluding Spare parts) Sanku, Chakram, Namam and Name Board of LED Sign Board.
Scope of works:
a) 12 technical visits in a year and each visit include attending repairs and servicing of LED sign boards.
b) In addition to the above technical visits, all Emergency calls should be attend within 48 hours and rectify the defect.
AMC for 4th year (Excluding Spare parts) Sanku, Chakram, Namam and Name Board of LED Sign Board. Scope of works:
a) 12 technical visits in a year and each visit include attending repairs and servicing of LED sign boards.
b) In addition to the above technical visits, all Emergency calls should be attend within 48 hours and rectify the defect.
AMC for 5th year (Excluding Spare parts) Sanku, Chakram, Namam and Name Board of LED Sign Board.
Scope of works:
a) 12 technical visits in a year and each visit include attending repairs and servicing of LED sign boards.
b) In addition to the above technical visits, all Emergency calls should be attend within 48 hours and rectify the defect.
Note: Agreements for Part:A & Part:B will be concluded separately with the successful bidder.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BOQ 289.xlsx
TENDER_DOCUMENT • 0.02 MB
289 NIT.doc
TENDER_DOCUMENT • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .