Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical The bidder has met the eligibility criteria outlined in the NIT |
| 2 | Accepted-Technical FCI ROAD KURBTHANG KARGIL KARGIL JAMMU KASHMIR 194103 UDYAM LA 01 0001435 | KARGIL | LADAKH | 194103 | Accepted-Technical The bidder has met the eligibility criteria outlined in the NIT |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹6.7 L
EMD Value
₹13,300
Closing Date
14 Mar 2026, 4:00 pmClosed
Xen RnB Division Kargil
Xen RnB Division Kargil
Upgradation of Community Hall at Thaskan Groung Kargil (Under CCDA)
2026_PWD_18594_1
E tender 141 of 2025-26 PW RnB Division 2nd Kargil
Open Tender
Civil Works - Buildings
Percentage
30 days
Kargil
Please refer Tender documents.
3 documents required · 3 mandatory
₹100
Xen RnB Division Kargil
₹13,300
16 Mar 2026
11 Mar 2026
16 Mar 2026
11 Mar 2026
14 Mar 2026
11 Mar 2026
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length Second class Kail wood
Providing and fixing panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for seperately,all complete as per direction of Engineer-in-charge.(Second class kail wood 35 mm thick shutter)
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick. Second class kail wood
Providing and fixing Float glass panes 4 mm thick glass pane (weight not less than 10kg/sqm) including beading & necessary components all complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
Preparing newly primed wooden surface for painting by way of filling of putty sand papering rubbing complete.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
Providing and fixing water closet squatting pan ( Indian type W.C. pan) with 100 mm sand cast Iron P or Strap, 10 litre low level P.V. C. flushing cistern including flush pipe (of approved make) "manually controled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. (Note : It should have flush rate of with Flush rate of 4/2 Litre per Flush or less ) (Dual flush 4/2L WC cistern with bottom inlet for compact back to wall Rimless toilet)
Orissa pattern white vitreous china W.C. pan of size 580x440 mm with integral type foot rests. JAGUAR/CERA Make
Providing and fixing wash basin with C.I./M.S. brackets, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:
White Vitreous China Wash basin size 630x450 mm JAGUAR / CERA/HINDWARE Make
P/F of mirrors of superior glass with plastic moulded frame(of approved quality) and of required size and shape. With 6mm thick hard board backing. Rectangular Shape 1500 x 450 mm
Providing and fixing soil waste & vent pipe (Prince or any other appoved brand as per Engineer In Charge
PVC Pipe. 110mm dia (10 feet unit Length)
PVC Pipe. 75mm dia (10 feet unit Length)
PVC Bend 110mm dia
PVC Bend 75mm dia
PVC Tee 110mm dia
PVC Tee 75mm dia
PVC trap 110mm dia
PVC trap 75mm dia
PVC Socket 110mm dia
PVC Socket 75mm dia
Providing and fixing 3 layer Thermex Pipe PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.
PN-16 pipe , 25mm OD(SDR-7.4)
PN-16 pipe , 32mm OD(SDR-7.4)
Providing and fixing accessories of standard and quality make of approved manufacturer including all necessary fixtures required.
AL Drop for room doors of approved brand or as per site engineer
AL Drop for Main doors of approved brand or as per site engineer
T- Bolt for doors of approved brand or as per site engineer
Handles for door of approved brand or as per site engineer
15 mm nominal bore C.P. brass angle cock for mixer and geyser points of approved make conforming to IS : 8931
15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. . 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
Supply installation testing and commissioning of Exaust Fan of approved brand (Havells/Bajaj/Crompton or any othet approved brand as per engineer in charge including all fixtures all complete
15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg.
High water pressure S.S geyser connection pipe (2 feet long) of approved quality and make,
Providing and fixing SS locking grating (jali) anti-cockroach
Providing and installation of water tank capacity 1000 ltrs of approved brand (SYNTEX OR ANY OTHER APPROVED BRAND) as per direction engineer incharge
Providing and laying vitrified floor tiles in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete i.e Size of tile 600x600 mm (Kajaria/Somany/Cera or Any approved Brand as per Engineer In charge)
P/F 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer) of approved make in colours, shades except burgundy bottle green, black of any size as approved by engineer-in-charge in Skirting, risers of steps, and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 course sand) and jointing with grey cement slurry @3.3kg/sqm including pointing the joint with white cement and matching pigments etc., complete. (Kajaria/Somany/Cera or Any approved Brand as per Engineer In charge)
Providing & Fixing approved Fabric with UPVC Stretched fabric panel system wit continuous perimeter track profile mounted on directly to the substrate. perimeter track profile required to confirm to panel edge details. Panel jointshall be butt, radius or as approved. System shall provide for face fabric to be perfectly tensioned over core materials, leaving fabric floating over core surface. System will allow for the removal and replacement of fabric facing from individual panels. Removal of fabric shall allow access to surface behind fabric without dismantling, removal or replacement of track members or core. Fabric paneling have stitching of matching colour on all sides as per design , back side GI stud 50mm 0.55 mm thick pressed section i.e cross channel are fastened . The Polyester Wadding of 50 mm thickness having density 1500 gsm
Internal Electrification
Sub Head-1
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in Existing surface/recessed medium class PVC conduit ,with modular switch,modular plate,suitable GI Box and earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required. (Group: A)
Wiring for circuit/sub mains wiring along with earth wire of the following size of FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit as required.
2x2.5 sq.mm + 1x 2.5 sq.mm
2x 4 Sq.mm + 1x4 sq.mm
Sub Head-2
Supply, installation,Testing & commissioning of Internal lighting fixtures
Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD < 10 % ,p.f.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted.
Angel Holder with LED lamp Square Block
LED 12W surface panel of lumen more than 1100 Round Shape.
Sub Head-3
GI Box along with modular base & Cover plates
S/F following size/module, GI box along with modular base and cover plate for modular switches/sockets in recess etc. as required:
4 module (125mm x 75mm)
6 module (200mm x 75mm)
8 module (200mm x 150mm)
Sub Head-4
Modulars Switches and Sockets
S/F following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required. (Make: Havells Crabtree/Legrand/HIFI Elleys /Gold Medel
6 amp switch
3 pin, 6 amp socket outlet
SS Combine 16A, Box
Sub Head-5
MCCB & MCB Distribution Board
MCB Distribution Board: S/F Double door MCB distribution boards, 240V/415V, Sheet steel, Powder coated DB’s suitable for MCB’s fitted with Bus Bar, Neutral link, Earth Bar and Din bar of following no. of ways :: (Make: Havells/C&S/L&T)
12 Way double door SP&N
8 Way double door S&N
S/F of 5 Amps to 63 Amps, 240/415V, “B series, ISI Mark” miniature circuit breakers suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required: (Make: Havells/C&S/V Guard)
Single pole 6A, SP MCB
Single pole 16A, MCB
Double pole 40A, DP MCB
Double pole 63A, DP MCB
Double pole 63A,DP C/O
Sub Head-6
Supply & Laying of Un-Armoured Cable & End Termination
Supplying and laying following size and specification of XLPE insulated PVC sheathed armored cable with aluminum conductor for working voltage 1100 V grade as per IS: 7908, including thimble/lugs, double compression glands etc.of respective size. (Make: Havells/Polycab/KEI)
2C x 16Sq.mm Armored Al. cable
stage.html
html • 0.03 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
BOQ_44599.xls
BOQ • 8.97 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .