Providing wood work in frames of false ceiling , partitions, etc sawn and fixed in position: Budloo wood, incl all costs and carriages involved nails, making of groove in joints, complete job
Providing and fixing 12 mm thick imported panelling incl all costs involved , nails, screws , favicol , and carriages incl 12 mm plywood
Providing and fixng of rock wool/ fiber glass insulation 50 - 60 mm thick incl all costs and carriages complete job
Providing and fixing reading stations by way of 18 mm plywood ,with liners / laminates on either side and edge panelling
Electric Part
Supply, Installation, testing and commissioning of 3 star rating 1.5 Ton Inverter type spilt Air Conditioner (Hot & cold) suitable for operation on AC supply single phase 50Hz 230V with hermetically sealed Inverter compressor with alr cooled condenser latest R410A/ R-32 refrigerant fan motor, start and run capacitors, relay and over load protector Internal unit with one Indoor and one outdoor unit. The Indoor unit fitted on wall by employing suitable clamps and the outdoor unit will be placed on angle Iron stand fitted witle nut/bolts outside the room to avold nolse, Including standard length of sultable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain plpe, suitable capacity 3 core sheathed/ PVC Insulated copper cable and a battery operated wireless remote unit. The Job Includes repairs to walls wherever the same are cut and the AMC of AC for a period of one year from date of successful commissioning. (Daikin/ Blue Star/LG/IFb)
Supply, Installation, testing and commissioning of relay type voltage stabilizer suitable for 1.5 Ton AC operating from input voltage 90-260Volt thereby producing output voltage of 230volts+- 3%. (4 KVA) V-Guard/LIV-Guard.
Supply and Installation of 32A modular plug/socket with 32A DP MCB for AC
Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC Insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing, etc. as required. (Maximum two points shall be connected on one circuit). (Havells/Polycab/Anchor/Finolex/KEI/RR or equivalent) excl. cost of condui
Point wiring for SA-10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires of Havells/ Polycab/Anchor/Finolex/KEI/RR make in recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop earthing), (Max. two points shall be connected on one circuit). (Havells/Polycab/Anchor/Finolex/KEI/RR or equivalent) excl. cost of conduit
Supplying and fixing of suitable size Gl box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 6 pin 16 A modular socket outlet and 16A modular switch, connections, etc. as required. (Havells/SSK/Anchor/ABB/Schneider or eq.)
Supplying and fixing of suitable size Gl box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 2 no. 3 pin 5/6 A modular socket outlet and 2 no. 5/6A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ABB/Schneider or eq.)
Wiring for sub mains along with earth wire in FRLS PVC Insulated 660/1100volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, excl. cost of conduits (Havells/Polycab/ Finolex/Anchor/KEI/RR or eq.)
4 x 10.0 sq.mm + 2x 6.0 sq. mm Heating Sub main
Supply and fixing of 4 way (4+12), Double door surface/ recess mounting, horizontal type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer
Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 КА "С" curve MCB of Legrand/ Havells/ L&T suitable for Inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 63A double pole rating 240/415V, 10 KА "С" 02 г curve MCB of Legrand/Havells/ L&T suitable for Inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 63A TPN MCB rating 240/415V, 10 KA "C" 01 curve MCB suitable for Inductive load In the MCB distribution board complete with necessary connections. (Havells/Legrand/Indo Aslan/Schneider)
Supply and fixing of 25 mm dla. Medlum class PVC conduit along with accessories in surface/1 recess, Incl. cutting the wall and making good the same or fixed with nalls/screws with rawlplugs or as required
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
BOQ_988030.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .