Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.1 LAccepted-AOC | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹4.5 L+₹17,667 (4.06%)Rejected-AOC ANAND GUJARAT 388001 | ANAND | GUJARAT | 388001 | 2 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 3 | 3₹5.2 L+₹85,875 (19.7%)Rejected-AOC | 3 | Rejected-AOC OTHER THAN L1 BIDDER |
Tender Value
Refer Docs
EMD Value
₹8,000
Closing Date
2 Feb 2021, 6:00 pmClosed
Garrison Engineer
GE I P Fy ISHAPORE, PO NAWABGANJ, DIST 24 PGS N WB-743144
As per tender documents
2020_MES_403342_2
8657/2020-21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE I P FY ISHAPORE
Class E Category b(I)
6 documents required · 6 mandatory
₹500
Yes
GE I P FY ISHAPORE
₹8,000
Yes
16 Mar 2021
18 Jan 2021
4 Feb 2021
18 Jan 2021
2 Feb 2021
18 Jan 2021
18 Jan 2021 - 26 Jan 2021
Amount
SCHEDULE "A" PART - I (MAINTENANCE OF CEILING FAN)
Taking down old unserviceable ceiling fan of any sweep including disconnecting the electric connection for repair and reuse at site or carrying to the store complete all as specified and as directed.
Hanging only ceiling fan of 1200 mm sweep and connecting up including provision of cable from ceiling rose or connector to fan after replacement of spare parts such as rewinding, ball bearing, iron bush, rubber bush, condensor, canopy, condensor stand, fan blade, down rod and painting complete all as specified and as directed. {Note:- (i) Ceiling fan shall be obtained from item No. 1.01. (ii) Spare parts shall be measured and paid under item No. 1.02 to 1.23. (iii) all other fixing accessories such as nuts, bolts, washsers, split pin, jam nuts, MS 'J' hook, etc. are included in this item.
All as per item No. 1.02 here-in-before but 1400mm sweep ceiling fan complete all as specified and as directed.
All as per item No. 1.02 here-in-before but 1500mm sweep ceiling fan complete all as specified and as directed.
Material and labour for rewinding of 1200mm sweep ceiling fan with suitable size of super enamelled copper wire including necessary heat varnishing, over hauling complete and reassembling the same in existing position including testing complete all as specified and as directed.
All as per item No. 1.05 here-in-before but 1400mm sweep ceiling fan complete all as specified and as directed.
All as per item No. 1.05 here-in-before but 1500mm sweep ceiling fan complete all as specified and as directed.
Supply ball bearing No. 6201 of ceiling fan.
Supply ball bearing No.6202 of ceiling fan.
Supply ball bearing No. 6203 of ceiling fan.
Supply only iron bushes of suitable size for ceiling fan.
Supply only rubber bush/ reel insulator of ceiling fan.
Supply only 2.5 MFD condenser of ceiling fan.
Supply only 3 MFD condenser of ceiling fan.
Supply only canopy (set) of ceiling fan.
Supply only condensor stand/ PVC bracket of ceiling fan.
Supply and fixing fan blade (set of three) suitable for 1200mm sweep ceiling fan including suitable nuts & bolts after taking down existing old unserviceable fan blade complete all as specified and as directed.
All as per item No. 1.17 here-in-before but 1400mm sweep ceiling fan complete all as specified and as directed.
All as per item No. 1.17 here-in-before but 1500mm sweep ceiling fan complete all as specified and as directed.
Supply only down rod 1/2" dia, 18" long of hanging of ceiling fan
Materials and labour for preparation of old ceiling fan exposed surfaces of 1200mm sweep and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer after removing existing paint by spray painting including filling caviies with filler complete all as specified and as directed.
All as per item No. 1.21 above but 1400mm sweep ceiling fan complete all as specified and as directed.
All as per item No. 1.21 above but 1500mm sweep ceiling fan complete all as specified and as directed.
SCHEDULE "A" PART - II (MAINTENANCE OF EXHAUST FAN)
Taking down old unserviceable exhaust fan of any sweep including disconnecting the electric connection for repair and reuse at site or carrying to the store complete all as specified and as directed.
Hanging only exhaust fan of 250 mm sweep and connecting up including provision of cable from ceiling rose or connector to fan after replacement of spare parts such as rewinding, ball bearing, iron bush, rubber bush, condensor, canopy, condensor stand, fan blade and painting complete all as specified and as directed. {Note:- (i) Exhaust fan shall be obtained from item No. 2.01. (ii) Spare parts shall be measured and paid under item No. 2.02 to 2.34. (iii) all other fixing accessories such as nuts, bolts, washsers, split pin, jam nuts, MS 'J' hook, etc. are included in this item.
All as per item No. 2.02 here-in-before but 300mm sweep exhaust fan complete all as specified and as directed.
All as per item No. 2.02 here-in-before but 400mm sweep exhaust fan complete all as specified and as directed.
All as per item No. 2.02 here-in-before but 450mm sweep exhaust fan complete all as specified and as directed.
All as per item No. 2.02 here-in-before but 600mm sweep exhaust fan complete all as specified and as directed.
Material and labour for rewinding of 250mm sweep exhaust fan with suitable size of super enamelled copper wire including necessary heat varnishing, over hauling complete and reassembling the same in existing position including testing complete all as specified and as directed.
All as per item No. 2.07 here-in-before but 300mm sweep exhaust fan complete all as specified and as directed.
All as per item No. 2.07 here-in-before but 400mm sweep exhaust fan complete all as specified and as directed.
All as per item No. 2.07 here-in-before but 450mm sweep exhaust fan complete all as specified and as directed.
All as per item No. 2.07 here-in-before but 600mm sweep exhaust fan complete all as specified and as directed.
Supply ball bearing No. 6301 of exhaust fan.
Supply ball bearing No.6302 of exhaust fan.
Supply ball bearing No. 6303 of exhaust fan.
Supply only iron bushes of suitable size for exhaust fan.
Supply only rubber bush/ reel insulator of exhaust fan.
Supply only 3.15 MFD condenser of exhaust fan.
Supply only 4 MFD condenser of exhaust fan.
Supply only condensor stand/ PVC bracket of exhaust fan.
Supply and fixing fan blade suitable for 250mm sweep exhaust fan including suitable nuts & bolts after taking down existing old unserviceable fan blade complete all as specified and as directed.
All as per item No. 2.20 here-in-before but 300mm sweep exhaust fan complete all as specified and as directed.
All as per item No. 2.20 here-in-before but 400mm sweep exhaust fan complete all as specified and as directed.
All as per item No. 2.20 here-in-before but 450mm sweep exhaust fan complete all as specified and as directed.
All as per item No. 2.20 here-in-before but 600mm sweep exhaust fan complete all as specified and as directed.
Materials and labour for preparation of old exhaust fan exposed surfaces of 250mm sweep and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer after removing existing paint by spray painting including filling caviies with filler complete all as specified and as directed.
All as per item No. 2.25 here-in-before but 300mm sweep exhaust fan complete all as specified and as directed.
All as per item No. 2.25 here-in-before but 400mm sweep exhaust fan complete all as specified and as directed.
All as per item No. 2.25 here-in-before but 450mm sweep exhaust fan complete all as specified and as directed.
All as per item No. 2.25 here-in-before but 600mm sweep exhaust fan complete all as specified and as directed.
Supply and fixing louvers made out by 1mm thick PGI sheet for 250mm sweep exhaust fan with fixing accessories including suitable nuts & bolts fixed on wall after taking down existing old unserviceable louvers complete all as specified and as directed.
All as per item No. 2.30 here-in-before but 300mm sweep exhaust fan complete all as specified and as directed.
All as per item No. 2.30 here-in-before but 400mm sweep exhaust fan complete all as specified and as directed.
All as per item No. 2.30 here-in-before but 450mm sweep exhaust fan complete all as specified and as directed.
All as per item No. 2.30 here-in-before but 600mm sweep exhaust fan complete all as specified and as directed.
SCHEDULE "A" PART - III (MAINTENANCE OF PEDESTAL FAN)
Disconnecting old unserviceable pedestal fan from existing location, carring to workshop for necessary repair and re-fixing the fan at same or different location after reparing complete all as specified and as directed Note : (i) Spare parts shall be measured and paid under relevant items. (ii) All other fixing accessories such as nuts, bolts, washers, split pin, jam nuts, MS J hook etc are incluided in this item (iii) Painting of ceiling fan shall be measured and paid under relevant item here-in-after.)
Material and labour for rewinding of 300mm sweep pedestal fan with suitable size of super enamelled copper wire including necessary heat varnishing, over hauling complete and reassembling the same in existing position including testing complete all as specified and as directed.
All as per item No. 3.02 here-in-before but 400mm sweep pedestal fan complete all as specified and as directed.
All as per item No. 3.02 here-in-before but 450mm sweep pedestal fan complete all as specified and as directed.
All as per item No. 3.02 here-in-before but 600mm sweep pedestal fan complete all as specified and as directed.
All as per item No. 3.02 here-in-before but 700mm sweep pedestal fan complete all as specified and as directed.
All as per item No. 3.02 here-in-before but 850mm sweep pedestal fan complete all as specified and as directed.
Supply ball bearing No. 6301 of pedestal fan.
Supply ball bearing No. 6302 of pedestal fan.
Supply ball bearing No. 6303 of pedestal fan.
Supply only iron bushes of suitable size for pedestal fan.
Supply only rubber bush/ reel insulator of pedestal fan.
Supply only 2.5 MFD condenser of pedestal fan.
Supply only 3.15 MFD condenser of pedestal fan.
Supply only condensor stand/ PVC bracket of pedestal fan.
Supply and fixing fan blade suitable to match the existing for 300mm sweep pedestal fan including suitable nuts & bolts after taking down existing old unserviceable fan blade complete all as specified and as directed.
All as per item No. 3.16 here-in-before but 400mm sweep pedestal fan complete all as specified and as directed.
All as per item No. 3.16 here-in-before but 450mm sweep pedestal fan complete all as specified and as directed.
All as per item No. 3.16 here-in-before but 600mm sweep pedestal fan complete all as specified and as directed.
All as per item No. 3.16 here-in-before but 700mm sweep pedestal fan complete all as specified and as directed.
All as per item No. 3.16 here-in-before but 850mm sweep pedestal fan complete all as specified and as directed.
Materials and labour for preparation of old pedistal fan exposed surfaces of 300mm sweep and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer after removing existing paint by spray painting including filling caviies with filler complete all as specified and as directed.
All as per item No. 3.22 here-in-before but 400mm sweep pedestal fan complete all as specified and as directed.
All as per item No. 3.22 here-in-before but 450mm sweep pedestal fan complete all as specified and as directed.
All as per item No. 3.22 here-in-before but 600mm sweep pedestal fan complete all as specified and as directed.
All as per item No. 3.22 here-in-before but 700mm sweep pedestal fan complete all as specified and as directed.
All as per item No. 3.22 here-in-before but 850mm sweep pedestal fan complete all as specified and as directed.
SCHEDULE "A" PART - IV (MAINTENANCE OF WALL MOUNTING FANS)
Taking down old unserviceable wall mounting fan of any sweep with disconnecting the electric connection for repair and reuse at site or carrying to the store complete all as specified and as directed.
Hanging only wal mounted fan of 300 mm sweep and connecting up including provision of cable from ceiling rose or connector to fan after replacement of spare parts such as rewinding, ball bearing, iron bush, rubber bush, condensor, canopy, condensor stand, fan blade and painting complete all as specified and as directed. {Note:- (i) Exhaust fan shall be obtained from item No. 4.01. (ii) Spare parts shall be measured and paid under item No. 4.02 to 1.13. (iii) all other fixing accessories such as nuts, bolts, washsers, split pin, jam nuts, MS 'J' hook, etc. are included in this item.
All as per item No. 4.02 here-in-before but 450mm sweep wall mounted fan complete all as specified and as directed.
Material and labour for rewinding of 300mm sweep wall mounted fan with suitable size of super enamelled copper wire including necessary heat varnishing, over hauling complete and reassembling the same in existing position including testing complete all as specified and as directed.
All as per item No. 4.04 here-in-before but 450mm sweep wall mounted fan complete all as specified and as directed.
Supply only iron bushes of suitable size for wall mounted fan.
Supply only rubber bush/ reel insulator of wall mounted fan.
Supply only 2.5 MFD condenser of wall mounted fan.
Supply only 3.15 MFD condenser of wall mounted fan.
Supply and fixing fan blade suitable for 300mm sweep wall mounted fan including suitable nuts & bolts after taking down existing old unserviceable fan blade complete all as specified and as directed.
All as per item No. 4.10 here-in-before but 450mm sweep wall mounted fan complete all as specified and as directed.
M/S RAJESH TRADING CO
ChakrabortyTraders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .