| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.3 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹29.5 L+₹20,106.26 (0.69%)Rejected-Finance ESD NO II UHL STAGE III BVPCL CHULLAH | LANGNA | MANDYA | KARNATAKA | 571401 | 2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical does not meet the minimum qualification criteria | |
| 4 | Rejected-Technical | - | Rejected-Technical does not meet the minimum qualification criteria |
Tender Value
₹29.5 L
EMD Value
₹51,800
Closing Date
13 Oct 2022, 10:00 amClosed
Executive Engineer
Executive Engineer HPPWD B and R Division Nahan
C/o 10.00 meter Span RCC Slab Culvert at RD 7/890
2022_PWD_66187_1
NAHAN 10171-10200
Open Tender
Civil Works - Roads
Item Rate
90 days
Nahan
As per Bidding Documents
9 documents required · 9 mandatory
₹1,500
₹51,800
14 Mar 2023
7 Oct 2022
13 Oct 2022
7 Oct 2022
13 Oct 2022
7 Oct 2022
Amount
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. including all leads,lifts and carriage of materials and other incidental charges complete as per entire satisfaction of the Engineer-in-charge.
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6 including all leads, lifts and carriage of materials and other incidental charges complete as per entire satisfaction of the Engineer-in-charge.
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 III. P.C.C. grade M 20 Nominal mix (1:2:4) ( one cement: two sand: four graded crushed atone aggregates) including carriage of materials with in all leads,lifts and other incidentals complete as per entire satisfaction of the Engineer-in-charge.
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 nominal mix C.C. 1:4:8 ( one cement four sand: eight crushed aggregates) including all leads,lifts and carriage of materials complete as per entire satisfaction of the Engineer in charge.
Providing weep holes in brick/stone masonry/plain/reinforcement concrete work abutment,wing walls,return walls with 100 mm (one hundred millimetre) dia VC pipe extending through the full widthof the structure with slope of 1(v) 1:20 I(V) 20(H)(one :Twenty((H) (Horizental) toward drawing face complete as per drawing and technical specification clause 614,709,1204.3.7. including hauling of material in all leads and lifts as per the entire satisfaction and direction of Engineer-in-Charge.
Back filling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (One Thousand Two hundred point three point Eight) including carriage of materials with in all leads,lifts and other incidentals complete as per entire satisfaction of the Engineer-in-charge.
Construction of embankment with approved material obtained from borrow pits with all lead and lift upto transporting to site, spreading, grading to required slope and compacting to meet required of Tables 300.1 and 300.2 as per technical specification clause 301.5 including all leads,lifts and carriage of materials complete as per entire satisfaction of the Engineer in charge.
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 R.C.C. grade M 25 cement conrete 1:1.5:3 including all leads,lifts and carriage of materials and other incidental charges complete as per entire satisfaction of the Engineer-in-charge.
Supplying, fitting and placing HYSD bar reinforcement in superstructure complete as per drawings and technical specifications Clauses 1002,1005,1010 and 1202 including all leads,lifts and carriage of materials complete as per entire satisfaction of the Engineer in charge.
ANIL KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .