AGE (I) R AND D JODHPUR
AGE (I) R AND D JODHPUR, Defence Laboratory, Ratanada Palace, Jodhpur- 342011
REPAIR TO INTERNAL WIRING, FITTING AND FIXTURES IN MD AND OTM ACCN AT DEFENCE LAB JODHPUR
2020_MES_386094_1
8397/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) R AND D JODHPUR
AS PER TENDE DETAILS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹18,000
Yes
10 Dec 2020
13 Oct 2020
9 Nov 2020
13 Oct 2020
5 Nov 2020
22 Oct 2020
14 Oct 2020 - 21 Oct 2020
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-charge
Material and Labour for point wiring with PVC insulated unsheathed, stranded copper conductor FRLS cable single core 1.5 Sqmm for one light point controlled by one way switch, and wire to be drawn in and including PVC heavy duty casing capping 20/25 mm width complete with all accessories including MS sheet metal 1.2mm thick switch board or PVC rectangular switch board of suitable size be fixed flushed wall, with 3.0 mm thick ebonite sheet cover and brass screws, cap washers etc as directed by Eng -in Charge and providing earth continuity wire using PVC insulated, un sheathed Single core stranded/solid copper conductor cable of size 1.5 Sqmm FRLS for light point complete all as specified and directed by Engineer-in-charge.
All as per item No 2 above but for one fan /Exhaust fan point controlled by one switch. .
All as per item No 2 above but for one socket outlet 5 amp on independent board.
All as per item No 2 above but for one socket outlet 15 amp on independent board with 2.5 Sq. mm cable and 1.5 Sq.mm. earth wire.
All as per item No. 2 above but for call bell/buzer controlled by one bell push switch.
All as per item No.2 above but for One three pin socket out let 5 Amps on the same board with other switches with cables 1.5 sq mm size.
All as per item No 2 above but one light point controlled by two 2-way switches, with cables 1.5 sqmm size
Supply and fixing including connection of switch piano flush type single pole one way 5 amps.
Supply and fixing including connection of switch modular flush type single pole one way 5 amps.
S&F in repairs Modular white cover plate set with frame 8 module complete all as specified and directed by engineer in charge.
Supply and fixing including connection of switch piano flush button type Two way 5 amps.
Supply and fixing including connection of switch socket combination 5 Amps 5 pin flush type
Supply and fixing including connection of switch socket combination 2 in 1, 5 pin 5/15 Amps flush type universal .
Supply and fixing of ceiling rose, surface bakelite 65x50 mm three terminal Ac 230 volt
Supply and fixing including connection of call bell AC-230 Volt single pole ding dong type.
Supply and fixing including connection of bell push, flush type 5 Amps.
Supply and fixing of resistance based step type fan regulator. Make -Anchor / Crompton/ Havells.
Supply and fixing Electronic Step type fan regulator. Make -Anchor / Crompton/ Havells.
S&F in repairs capacitor 2.5 MFD suitable for ceiling fan / exhaust fan / Mounting fan of any sweep complete all as specified and directed by Engineer-in-charge.
Supply and fixing socket out let 2 in one, 5/3 pin 5Amp
Supply and fixing lamp holder insulated body with back plate for angle holder.
M&L for earthing with galvanized steel earth plate electrode of size 600 mm x 600 m x 6.0 mm buried directly in ground (earth pit not less than 2.25 Mtr b elow normal ground level) connected to galvanized earth lead of size 4 mm by means of bolts, buts, check nuts and washers of galvanized iron on steel including 20 mm dia light grade GI tubing for protection of earth lead, MS sheet m etal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 RCC(1:2:4) type B1 pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including necessary excavation, earthwork in soft /loose soil and necessary connection and testing complete all as shown in electrical plate No. 3 complete all as specified and directed by Engineer-in-charge.
Taking down old UNSV tube light with all fitting and Supply & Fixing LED Tube light batten fitting for and including LED tube light 1x20 W cool white complete all as specified and directed. Make:Bajaj/Crompton /Havells.
Supply & Fixing LED tube light 1x20 W cool white complete all as specified and directed. Make:Bajaj/Crompton /Havells.
Taking down old UNSV fitting and Supply & Fixing Bulk Head LED fitting surface mounting type with toughened glass cover suitable for and including 1x10 watt LED lamp complete all as specified and directed by Engineer-in-charge. Make:Bajaj/Crompton /Havells.
Taking down old unserviceable copper/aluminium sub main wiring any size complete all as specified and directed by Engineer-in-charge.
M/L for sub main wiring with two single core stranded copper conductor PVC unsheathed in and incl non metalic PVC conduit 20mm dia medium Grade surface/recessed 2-RUN of 4.00 Sqmm FRLS cable incl one RUN of 2.5 Sqmm FRLS single core stranded cable for continuous earth wire and connected to earth dolly on sub main wiring complete all as specified and directed by Engr-in-Charge.
All as per item No 25 above but 2x6.00 Sqmm FRLS cable incl one RUN of 4.0 Sqmm single core stranded cable for continuous earth wire all as specified and directed by engineer in charge.
Taking down ceiling fan/exhuast fan, sealing cable end dismantling blades and removing fan and blades and hanging the fan after repairing complete all as specified and directed by Engineer-in- charge.
M&L for repair of ceiling fan 1200mm sweep of any make obtained from above item, Rewinding with super enamelled copper wire, baking, casting, assembling, oiling, greasing cleaning slot, over hauling & replacement of defective capacitor, nut bolts washer etc including painting all as specified and directed by Engr-in-charge.
Taking down unserviceable Main switch/DBs any type/any size
Supply and fixing of MCB DB made of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail , 240 Volts SPN with 8 way single door.
Supply and fixing of MCB DB made of sheet steel phosphatised, powder painted with bus bar, neutral link, earth bar and Din rail , 240 Volts SPN with 8 way double door.
Supply and fix vertical three phase & Neutral (TP&N Vertical) Distribution Board 4 way single door with provision for (MCB/Isolator/RCB) as incomming with three phase and single phase (TP/SP) outgoings, complete with insulated bus bar arrangement complete all as specified and directed by Engineer-in-charge.
Supply fixing, connection and testing MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32Amps .
Supply fixing, connection and testing MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 40-63Amps .Make legrand or equivalent
Supply fixing, connection and testing MCB SP 6-32 Amps
S&F Isolator TP 415 Volts 63 Amp, 16 KA breaking capacity, thermal class ‘C’ in existing distribution board including connecting up complete.
S&F in repairs decorative ultra slim linear 18W, 6500K, LED lighting fixture with co extruded polycarbonate body,environmentalfriendly,energy efficient ready to use pack complete all as specified and directed by Engineer-in-charge.(Havells cat part No:LHEXBLP7UN1W018 or equivalent make as approved by AGE(I) )
S&F in repairs T-5 lamp 1x28 watts complete all as specified and directed by Engineer-in-charge.Make:Bajaj/Crompton /Havells
S&F in repairs electronic ballast for T-5 lamp 1x28 watts complete all as specified and directed by Engineer-in-charge.
Disconnecting existing U/S gate light and broken top post lantern fitting of any wattage.
Supply and fixing of top Post lantern fitting of 70 watt LED , Casting LED post top made in cast aluminium spigot house up with decorative opal acrylic diffuser and IP 65 protection of 70 watt LED Make Bajaj/CG/Havell/philips.
Supply and fixing of 8"x8" ceiling square 8W LED light of polycarbonate material including all the fittings and necessary connection and testing complete all as specified and directed by Engineer-in-charge. Make Bajaj/CG/Havell/philips.
Supply and fixing of 2'x2' ceiling square 36 Watt LED panel light,extruded aluminium frame size,input voltage AC 90-300 V including all the fittings and necessary connection and testing complete all as specified and directed by Engineer-in-charge. Make Bajaj/CG/Havell/philips.
S&F LED Bulb 9 Watt normal retro type fitting. Make CG/Philips/Havells
M/s Shiv Builder and Suppliers
VARDHMAN SALES CORPORATION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .