| Sl No | Description | Qty | Unit | PBS Switchgears and Automation Pvt Ltd L1 |
|---|---|---|---|---|
| 1.00Supply, Erection, Testing and Commissioning of 11KV Indoor Metering Unit and connected works | ||||
| 1.00 | OD31846/2026-2027:Supply,erection, testing and commissioning of indoor type
Potential Transformer Unit as per the following specifications,Pt ratio 11kv/110v burden 25VA,accuracy class 0.2 | 3 | set | 40,599 ₹1,21,797 Lowest |
| 1.00 | OD31848/2026-2027:supply erection testing and commissioning of indoor type current transformer unit.CT ratio 100/5A burden 10VA,accuracy class 0.2S for 11kv indoor current transformer unit | 6 | no | 26,708 ₹1,60,248 Lowest |
| 1.00 | OD31850/2026-2027:supply erection testing and commissioning of indoor type current transformer unit.CT ratio 120/5A burden 10VA,accuracy class 0.2S for 11kv indoor current transformer unit | 6 | no | 27,870 ₹1,67,220 Lowest |
| 1.00 | OD31849/2026-2027:Supply, erection, testing and commissioning of TEST Terminal block , HRC fuses and wiring cables for inter connecting the CT, PT and TOD meter for TEST Terminal block | 2 | set | 9,231 ₹18,462 Lowest |
| 1.00 | OD31847/2026-2027:Supply of all materials and carrying out the alteration works in the existing HT panel for accomodating the 11KV indoor one no. potential transformer and 3Nos. Current transformers after dismantling the damaged equipments for alteration works in existing HT panel | 1 | set | 40,651 ₹40,651 Lowest |
| 1.01 | OD31853/2026-2027:Supply,erection, testing and commissioning of TOD meter with maximum demand in KVA, accuracy class 0.2S, suitable for the above in door metering set housed in the existing weather proof in door Kiosk. | 2 | set | 52,265 ₹1,04,530 Lowest |
| 1.01 | OD31851/2026-2027:Dismantling of old indoor CT PT Unit, TOD Meter with in the cubicle, Inter connecting cables, MS Structural Items etc. complete | 1 | set | 2,322 ₹2,322 Lowest |
| 1.01 | OD31852/2026-2027:Preparation of documents for HT application for revised
contract demand. This does not include approval from
Electrical Inspectorate for additional loads | 1 | set | 27,700 ₹27,700 Lowest |
Tender Value
₹6.4 L
EMD Value
₹16,080
Closing Date
28 May 2026, 2:00 pmClosed
Assistant Executive Engineer
KWA, PH Sub Division,Valakom
State Plan 2025_26 JICA Meenad scheme Replacing CTPT unit and TOD metre at 73 MLD Raw Water Pump House Tholicod
2025_KWA_776068_4
WRD/KWA-CE(SR)/TR/21057/2024_3
Open Tender
Civil Works - Water Works
Item Rate
90 days
Intake Pump house, Tholikkode
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,420
₹16,080
3 Oct 2026
23 May 2026
29 May 2026
23 May 2026
28 May 2026
23 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Erection, Testing and Commissioning of 11KV Indoor Metering Unit and connected works | |||||
| 1.001 | OD31846/2026-2027:Supply,erection, testing and commissioning of indoor type
Potential Transformer Unit as per the following specifications,Pt ratio 11kv/110v burden 25VA,accuracy class 0.2 | - | set | - | - |
| 1.002 | OD31848/2026-2027:supply erection testing and commissioning of indoor type current transformer unit.CT ratio 100/5A burden 10VA,accuracy class 0.2S for 11kv indoor current transformer unit | - | no | - | - |
| 1.003 | OD31850/2026-2027:supply erection testing and commissioning of indoor type current transformer unit.CT ratio 120/5A burden 10VA,accuracy class 0.2S for 11kv indoor current transformer unit | - | no | - | - |
| 1.004 | OD31849/2026-2027:Supply, erection, testing and commissioning of TEST Terminal block , HRC fuses and wiring cables for inter connecting the CT, PT and TOD meter for TEST Terminal block | - | set | - | - |
| 1.005 | OD31847/2026-2027:Supply of all materials and carrying out the alteration works in the existing HT panel for accomodating the 11KV indoor one no. potential transformer and 3Nos. Current transformers after dismantling the damaged equipments for alteration works in existing HT panel | - | set | - | - |
| 1.006 | OD31853/2026-2027:Supply,erection, testing and commissioning of TOD meter with maximum demand in KVA, accuracy class 0.2S, suitable for the above in door metering set housed in the existing weather proof in door Kiosk. | - | set | - | - |
| 1.007 | OD31851/2026-2027:Dismantling of old indoor CT PT Unit, TOD Meter with in the cubicle, Inter connecting cables, MS Structural Items etc. complete | - | set | - | - |
| 1.008 | OD31852/2026-2027:Preparation of documents for HT application for revised
contract demand. This does not include approval from
Electrical Inspectorate for additional loads | - | set | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1440640.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_1440640.xls
BOQ • 0.30 MB
biddocument.pdf
Tender Documents • 0.61 MB
RetenderExtension.pdf
PDF • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .