Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 CrAccepted-Finance | ₹21.2 Cr | L1 | Accepted-Finance Lowest Bidder |
| 2 | L2₹21.4 CrRejected-Finance | ₹21.4 Cr | L2 | Rejected-Finance Second Lowest |
| 3 | L3₹23.1 CrRejected-Finance 302 OPAL 2 OPP SILVER OAK BUILDING B P C ROAD AKOTA VADODARA GUJARAT 390020 | VADODARA | GUJARAT | 390020 | ₹23.1 Cr | L3 | Rejected-Finance Third Lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not complied as per pre-qualification criteria |
Tender Value
₹27.9 Cr
EMD Value
₹69.7 L
Closing Date
19 Sept 2024, 3:00 pmClosed
Regisrtar
RRU Lavad Campus, Gandhiangar, 382305
CONSTRUCTION OF INDOOR SPORTS COMPLEX (PHASE - I) AND ANY OTHER ALLIED INFRASTRUCTURE WORK AT RRU CAMPUS AT LAVAD, GANDHINAGAR
2024_RRU_823637_1
RRU/CDMB/2024-25/01
Open Tender
Civil Works
365 days
RRU Lavad Campus, Gandhiangar
Please refer Tender documents.
4 documents required · 4 mandatory
₹21,240
Yes
Registrar, Rashtriya Raksha University
₹69.7 L
Yes
Online - Google Meeting
4 Oct 2024
30 Aug 2024
20 Sept 2024
30 Aug 2024
19 Sept 2024
30 Aug 2024
6 Sept 2024
Amount
Civil Work
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer- incharge. All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. a) Concrete of M25 grade with minimum cement content of 330 kg /cum: All works upto plinth level
b) Concrete of M25 grade with minimum cement content of 330 kg /cum: All works above plinth level upto floor V level
E) Concrete of M35 grade with minimum cement content of 370 kg /cum: All works upto plinth level
F) Concrete of M35 grade with minimum cement content of 370 kg /cum: All works above plinth level upto floor V level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-550D.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Stairs, (excluding landings) except spiral-staircases
Centering and shuttering including strutting, propping etc. and removal of form for : Extra for shuttering in circular work (20% of respective centering and shuttering items)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level. : Cement mortar 1:4 (1 cement :4 coarse sand)
CEMENT PLASTER (IN COARSE SAND): Providing and laying plaster : 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Extra for providing and mixing water proofing material in cement per bag of plaster work in proportion recommended by the manufacturers.
Squash Hard Plaster:- Providing and laying of hard plaster consist of plaster 4mm thick, fiber reinforced, cement based and resin modified. Marking lines in red colour and painting with epoxy paint. Approved by WSF. Work shall be executed all Complete as per direction of Engineer in charge/Architect.
Expansion joint finishing Wall to wall joint: Providing and fixing Construction Specialties make or equivalent interior wall to wall expansion joint cover model W90 for 50 mm gap size, this surface mounted aluminium cover is designed for interior application where low maintenance is desirable. This model is made using Aluminium alloy 6063 and temper T5/T6. This cover is installed using stailness steel clip in the rear which helps the movement to + 10 mm. Rate shall inclusive of mock up sample, all materials, loading, unloading, transportation, placing at all floors and for all leads, at all floors, all levels, all heights and all shapes, all accessorie, Scaffolding, protectiion sheet etc. work complete as per the detailed drawing, approved sample and instruction of Architect/EIC.
Supplying, diluting & Injecting chemical emulsion for Pre constructional Anti Termite Treatment With Chlorpyriphos/Lindane E.C. 20% with 1% concentration in 3 stages creating a continuous chemical barrier all-round the building including diluting in water as per manufacturer's specification conforming to IS 6313: 1981 in under & all around raft slab, beam, footings, column pits, trenches, wall trenches, backfill, plinth filling, junction of wall and floor, external perimeter of building, surrounding of pipes, over the top surface of the consolidated earth etc. for all lead and lift.. The treatment shall be carried out by specialized agency specified by the Client/ Consultant. Plinth area at ground level excluding open courts shall be measured. Treatment of soil under floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish, Size of Tile 600 x 600 mm (Toilet area flooring)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in dedo, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (Toilet area dedo and skirting)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for window sills, door frame and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, stone adhesive , including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Rate shall inclusive of mock up sample, all materials, loading, unloading, transportation, placing at all floors and for all leads, at all floors, all levels, all heights and all shapes, all accessories, Scaffolding, protectiion sheet etc. work complete as per the detailed drawing, approved sample and instruction of Architect/EIC. Sample mock shall be approved from Architect/EIC. (Door Frame)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for window sills, door frame and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, stone adhesive , including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Rate shall inclusive of mock up sample, all materials, loading, unloading, transportation, placing at all floors and for all leads, at all floors, all levels, all heights and all shapes, all accessorie, Scaffolding, protectiion sheet etc. work complete as per the detailed drawing, approved sample and instruction of Architect/EIC. Sample mock shall be approved from Architect/EIC. (Window sill)
Granite/ Artificial stone Basin Counter/ Handwash / Drinking counter: Providing & fixing two layers of wash basin counter, first layer using 25mm thick Kotastone of approved shade and second layer using approved shade and sample of 18 mm thick Mirror finish Granite, joined together with 1:4 Cement mortar bedding / approved tile adhesive , to true plane & level or to slopes, or close jointed with cement slurry with pigment of matching shade and colour and finishing with the same, including dedo 1'6", cutting kotah & tile as per required shape & size to fit Wash basin & 4" facia with moulding, nosing, chamfered front edges, fixing, disposal of debris etc. finished as per design in detail drawing and instruction of Architect/EIC.sample mock shall be approved from Architect/EIC. Basic rate of stone is 130/- Sq.ft
Granite / Artificial Kitchen/pantry Platform: Providing & fixing two layers of Pantry Platform, first layer using 25mm thick Kotastone of approved shade and second layer using approved shade and sample of 18 mm thick Mirror finish Granite, joined together with 1:4 Cement mortar bedding / approved tile adhesive , to true plane & level or to slopes, or close jointed with cement slurry with pigment of matching shade and colour and finishing with the same, including dedo 1'6", cutting kotah & tile as per required shape & size to fit sink & 4" facia with moulding, nosing, chamfered front edges, fixing, disposal of debris etc. finished as per design in detail drawing and instruction of Architect/EIC.sample mock shall be approved from Architect/EIC. Basic rate of stone is 130/- Sq.ft
Flushing Tank: Providing and fixing Preumatic Flushing tank of as per approved make list . Work complete including all type of finishing. Model Equivalent to Jaquar code JCSWHT- 2400WP
Flush Plate: Providing and fixing FLUSH PLATE POLISHED CHROME of as per approved make list . Work complete including all type of finishing. Model Equivalent to Jaquar code JCPCHR- 352415
Health faucet: Providing and fixing 12mm dia. Health faucet with 8 mm dia of as per approved make list with flexible pipe of 1.mt. length and holding stands complete. Work complete including all type of finishing. Model Equivalent to Jaquar code ALD-CHR-573
Toilet Papers Holder: Providing and fixing Toilet papers holder of as per approved make list. Work complete including all type of finishing. Model Equivalent to Model Equivalent to Jaquar code ACNCHR- 1151N
Two Way Bib Tap: Providing and fixing 15mm dia Two way Bib Cock of as per approved make list. Work complete including all type of finishing. Model Equivalent to Model Equivalent to Jaquar code COSCHR- 103041
Wash Basin: Providing and fixing Wash Basin including fittings and waste pipe and fixing on wash basin counter by tile adhesive of approved make. Work complete including all type of finishing. Model Equivalent to Jaquar code CNS-WHT-701 UNDER COUNTER BASIN WITH COUPLING AND FIXING ACCESSORIES SIZE:485X370X205MM SHAPE: RECTANGULAR
Wash Basin: Providing and fixing Wash Basin including fittings and waste pipe and fixing on wash basin counter by tile adhesive of approved make. Work complete including all type of finishing. Model Equivalent to Jaquar code JDSWHT- 25907N THIN RIM TABLE TOP BASIN SIZE:530X420X1 40 MM SHAPE -RECTANGULAR INCLUDING WAST COUPLING
Basin spout : Providing and fixing 15mm dia Basin spout of as per approved make list and work complete including all type of accessories. Model Equivalent to Jaquar code COSCHR-103001M
Basin spout : Providing and fixing 15mm dia Basin spout of as per approved make list and work complete including all type of accessories. Model Equivalent to Jaquar KUPCHR- 35441KPM + ALD-CHR-441. EXPOSED PART KIT OF SINGLE CONCEALED STOP COCK CONSISTING OF OPERATING LEVER CARTRIDGE SLEEVE WALL FLANGE (WITH SEALS) & BASIN SPOUT (COMPATIBLE WITH ALD-441) + CONCEALED BODY ONLY FOR SINGEL CONCEALED STOP COCK WTH BASIN SPOUT (WITHOUT EXPOSED PARTS)
Urinal : Providing and fixing in position of Urinal of as per approved make list. Work completed as per the instruction of EIC. Model Equivalent to Jaquar code ECS-WHT-253 URINAL WITH FIXING ACCESSORIES SIZE:330X315X420
Angular Cock: Providing and fixing 15mm dia. Angular Cock as per approved make list and work complete including all type of accessories . Model equivalent to Jaquar code ARI-CHR-39053
Soap Dispensor: Providing and fixing in position Soap Dispensor as per approved make list and work complete including all type of accessories. Model equivalent to JAQUAR - CAT- CAN-1135N
Handrayer : Providing and fixing in position of Handdrayer of as per approved make list. Work completed as per the instruction of EIC. Model Equivalent to Jaquar code HDF-SSF-AK2803D
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. with necessary coupling for wash basin & sink.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mm
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Urinal partition: Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
Overhead shower : Providing and fixing Overhead Shower with shower arm of JAQUAR/HINDWARE or equivalent approved make with all necessary fittings material work complete as per the detailed drawing. Rate shall be inclusive of all materials, loading, unloading, transportation, placing at all floors and for all leads,etc complete as per detailed drawing & Instruction of Architect/EIC. Model Equivalent to Jaquar code No : EOS-CHR-542N+ALE-CHR-536A
Bath Spout : Providing and fixing Bath spout as per approved make list and work complete including all type of accessories . Model equivalent to Jaquar code SPJCHR-35429PM KUBIX PRIME BATH TUB SPOUT WITH WALL FLANGE
Divertor : Providing and fixing Divertor with conceated part as per approved make list and work complete including all type of accessories . Model equivalent to Jaquar code KUPCHR-35079NKPM+ ALD-CHR-079N SINGLE LEVER EXPOSED PARTS KIT OF HI-FLOW DIVERTER CONSISTING OF OPERATING LEVER CARTRIDGE SLEEVE WALL FLANGE (WITH SEALS) BUTTON ASSEMBLY SLEEVE & BUTTON (COMPATIBLE WITH ALD-079N)+ CONCEALED BODY FOR SINGLE LEVER HIGH FLOW DIVERTER WITH BUTTON ASSEMBLY BUT WITHOUT EXPOSED PARTS
Pressmatic wall mounted Spout: Providing and fixing Auto Closing Bib Cock with wall flange, complete with all fittings & accessories, including cutting and making good the walls where required as per specifications and directions of Engineer. Make: Jaquar - PRS-CHR-043
Waste coupling: Providing and fixing 32 mm dia CP brass waste coupling full thread with 80mm height complete with all fittings & accessories, including cutting and making good the Granite & Kota s where required as per specifications and directions of Engineer. Make: Jaquar - ALD - 705
Toilet Cubical : Model Type: Equivalent to Greenlam Sturdo Essentia Seren : Thickness of Compact Laminate : 12mm Nos 1 32075 32075 . Door : 600mm*1785mm , Divider Height : 1820mm , Overall height : 1995mm (Including 150mm Ground clearance) Supply & Installation of Toilet Cubicles as per approved make & sample by Architect . 12 mm Compact Grade 1.5 mm thick laminateBoard of the approved shade by Architect . Accessories for cubicles.1. Aluminum “U” Section with a) Aluminum U Channel b) Nylon Gravity hinges c) Nylon Coat Hook d) Nylon Adjustable Leg e) Nylon Door Knob f) Nylon Thumb Turm Indicator g) Aluminium Door Stopper Channel h) Aluminium Top Rail e) Screws, Wall Plugs & Noise Tape Etc. Work complete including all type of fittings, fixtures, tools, etc complete as per manufacturer specification and drawing.
Changing room cubical : Model Type: Equivalent to Greenlam Sturdo Essentia Seren : Thickness of Compact Laminate : 12mm Nos 1 32075 32075 . Door : 600mm*1785mm , Divider Height : 1820mm , Overall height : 1995mm (Including 150mm Ground clearance) Supply & Installation of Toilet Cubicles as per approved make & sample by Architect . 12 mm Compact Grade 1.5 mm thick laminateBoard of the approved shade by Architect . Accessories for cubicles.1. Aluminum “U” Section with a) Aluminum U Channel top & botttom b) Nylon Gravity hinges c) Nylon Coat Hook e) Nylon Door Knob f) Nylon Thumb Turm Indicator g) Aluminium Door Stopper Channel h) Aluminium Top Rail e) Screws, Wall Plugs & Noise Tape Etc. Work complete including all type of fittings, fixtures, tools, etc complete as per manufacturer specification and drawing.
Single Glaze Unit (SGU): Design, Fabrication, Supply, Installation & Handover of Single glass glazing system. Semi-unitized glass glazing Auminium (sash frame) fix Glass section Jindal make or equivalent curtain section No. 22736 size 81.16mm x 50mm x 2mm weight 1.615 kg/mtr. Section No. 22738 size 81.16 x 38.5 x 2mm weight 1.294 kg/mtr. Shash frame section No. 35800 size 37.1mm x27.5mm x1.4mm weight 0.548 kg/mtr. Patti for shash frame 29.2mm x7.95mm x 2 mm , Akzonobel powder coated Aluminium section code SP338N with 50 micron. 5mm ET -125 Reflective Toughened Glass make Saint Gobin. 2mm thick x 12mm Brode 3M VHB Tape for stick glass, glass to metal structural sealent silicon & weather sealent silicon for groove, EPDM Gasket, m.s. bracket zinc coated, other necessary fixtures & fastening as per drawing specification (GLASS PANEL SIZE 1200 X 1820, 1200 X 1180) Work complete including all type of hardware, fittings , fixtures as per instruction of Client/Archtect etc. Rate including all type of scaffolding, safety measures, form work at all floor, all levels etc. complete per detailed drawings and specifications, sample mock shall be approved from architect / client.
Opening in Glazing : Extra for openable side / top hung vision glass panels including providing supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hingis, min 4-point cremne locking sets with stainless steel plates, handles , buffers etc. including necessary stainless steel screws / fasteners, nuts, bolt, washers, fafety measures etc. all compete as per the Architectural drawings, as per the approved drawings, as specified and as directed by the engineer in-charge. sample mock shall be approved architect/ EIC.
PEB WORK: (Multi court hall) : Clear Heights ( from PL ) : 10.45 Mtr Design, supply , installation , fabrication , testing & commissioning of structure, Supply and Transportation to site the structural steel work with Two coats of Epoxy Paints (90–100-micron DFT) as per approved sample by EIC/Client. Shop Drawing: Contractor shall submit PEB design shop drawing & load calculation including all type of services like Electrical, false ceiling and HVAC for approval of the Architect before execution. Roof Panel: Profiled sheet; 0.47 mm BGL of JINDAL/ TATA DSL/JSW as per approved make & sample by Architect. Structure : Built up sections are made from hot rolled steel & Cold formed section, Baring rods , sag rods with sand blasting & finish with epoxy paint ( 90–100-micron DFT ) as per approved colour by Architect/Client. Make : JSW, Essar, Tata, Sail. (Additional Load shall be considered for False ceiling + AC ducting work) Accessories: Anchor Fasteners with hot dipped galvanized, high strength bolts, EPDM washer, necessary tools, tackles, Scaffolding, fittings, fixtures, Adhesive, sealant, etc complete. Work complete including all type of necessary tools, tackles, machinaries, Crane, equipment, labour, Scaffolding, drilling, gutter, down pipe etc. as per approved drawing. The specialized team required from appointed contractor side. The contractor shall submit works stability certificate after execution of work. Only roof area shall be measured and paid for the same. Work completed as per the instruction of EIC.
100 MM DIA core cutting
125 MM DIA core cutting
150 MM DIA core cutting
Plumbing work
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes
20 mm nominal dia Pipes
25 mm nominal dia Pipes
32 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipes
25 mm nominal dia Pipes
32 mm nominal dia Pipes
40 mm nominal dia Pipes
50 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 65 mm nominal dia Pipes
80 mm nominal dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
80 mm nominal bore
100 mm S.C.I. trap with 100 mm inlet and 75 mm outlet
100 mm S.C.I. trap with 100 mm inlet and 100 mm outlet
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe: 40mm dia
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(G)110 mm
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure polythene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(F) 75mm
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 75 mm dia
100 mm dia
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Group B
Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
2 way 5/6 A Switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
Bell push
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
3 Module
4 Module
6 Module
8 Module
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Installing of Exhaust Fan in existing opening, including and making good the connection, damage connection, testing commissioning etc as required. upto 450mm sweep
Extra for fitting of Lowers/shutters complete with frame for exhaust fan of all size.
Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to the RCC bars up to 50mm length each side and pierced through a 16 Gauge M.S. box / Heavy Duty PVC box complete erected concealed in Ceiling with necessary finishing.
FIRE FIGHTING WORKS
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25mm dia
32mm dia
40mm dia
50mm dia
65mm dia
80mm dia
100mm dia
150mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100mm dia
150mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40m
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun Metal
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Pendent Sprinkler
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 100mm dia
150mm dia
Rate only Items
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
RCC (Reinforced Cement Concrete): Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. c) Concrete of M30 grade with minimum cement content of 350 kg /cum: All works upto plinth level
d) Concrete of M30 grade with minimum cement content of 350 kg /cum: All works above plinth level upto floor V level
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/ 300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
CEMENT PLASTER (IN COARSE SAND): Providing and laying plaster : 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)
CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT: 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT: 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete.
Metal Roof Waterproofing with SikaPlan 750 TPE : Substrate Preparation: Cleaning the metal surface to make it rust, dust and sludge free, and using anti corrosive coating wherever required after throughly cleaning with water jet. Vapour barrier:Providing and applying of Sarnavap or equivalent, a single layer vapour control layer based on high density polyethylene film. Overlap of the vapour control layer is minimum 100 mm. All seams mast be adhered together according to the manufacturer specifications and best practice. Thermal Insulation:Providing and applying 80 mm thick expanded polystyrene insulation board on the roof with Roof Bond adhesive. Product: Sarnatherm EPS 18 , Product requirements: density: min 27 kg/m3. Providing and fixing 300 GSM geotextile as a separation layer above existing substrate with an overlap of 50mm and the overlap is kept loose but joints of geotextile shall be welded to ensure TPO membrane is not in touch with bitumen at any point in time. Supply and application of Single ply roofing membrane of 1.5 mm thick TPO Membrane polyester reinforced SikaPlan 750 TPE shall be mechanically fastened using ETA approved fastners tested for 5% salt spray test for min240 house without rusting. TPO Membrane shall have following performance:-1. Tensile strength as per EN 12311 >1100 N/cm22. Resistance to Impact as per EN 12691 > 800mm 3. Resistance to static punching > 20KG4. Hydrostatic pressure resistance(6 hours at 5 bar ) as per EN 1928 : passing 5. Dimensional stability after 6 horus at 80C, EN 1107-2 : <0.5% Membrane shall be mechanically fastened on the perimeter with special membrane washers and screws considering the substrate and shall be hot air welded on the overlaps . Membrane shall be terminated by using special aluminium strip followed by PU sealant at the top of parapet wall. Metal Termination: Providing & fixing metal strip along with mechanical anchor and filling the mouth with P.U. sealant etc. complete at termination level of membrane as per manufacturer specification etc. complete This work is to be got executed through as per approved make list specialized agency. Guarantee for a minimum period on non judicial stamp paper of required value as per format approved by Architect is to be submitted by the contractor. Bank's decision on approval of make/agency shall be final and binding on all.The plan area shall be measured for payment purpose.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. : For vertical surface two coats @ 0.70 kg per sqm (UGWT & OHWT)
For horizontal surface one coat @1.10 kg per sqm. (UGWT & OHWT)
Terrace Waterproofing : Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry , including vata , and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish, Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish, Size of Tile 600 x 1200 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (skirting & riser)
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 800x800 mm
Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing as desired by architect complete with base of cementmortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. Grey Polished kota stone 60 % or yellow river finish kota stone :40 %
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.Grey Polished kota stone 60 % or yellow river finish kota stone :40 %
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (UGWT & OHWT)
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (water tank)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.: 40 mm thick with 20 mm nominal size stone aggregate
Synthetic Polyurethane : PRO FLEX WATER BASE PU CUSHION FLOORING (10mm EPRF SHEET BASE HYBRID POLYURETHANE CUSHION FLOORING) Moldo – 10mm Supply and application of Elastic PolyUtherene Rubber of 8mm(EPRF) Sheets fixed with hybrid waterbase PU adhesive on concrete surface having intense shock absorbance. On top of eprf Sheets following layer system are applied. One layer of hybrid filament reinforcement. 3 layers of colored fine rubber cushion are applied. 2 layers of PU colored top coat are applied to protect flooring against UV Rays giving a smooth feel to the finish surface (Top Coat thickness 2mm) Total thickness 10mm EPRF sheet Reva-R Foam is made up of metallocene POE elastomer blended with EVA and thermoplastic polyurethane, it is the best alternative of EPDM rubber cushion. * Excellent resilience, No PVC, No LATEX and No Phthalates nor heavy metal. * Does not absorb moisture, prevent bacteria or fungal growth. * Excellent in elasticity flexibility * Superior in cushion * Low-temperature toughness, * Stress-crack resistance, * Resistance to UV radiation. * 70~80% stronger than regular EVA foam in tensile, elongation, tear strength, and compression set and shrinkage. Game line marking will be carried out in required colors before applying the finish coat.work complete including all type of fittings, fixing, fixtures, accessories, tools, tackles, scaffolding , at all floor, all level, all depth, all Height, all lead and lift, mock up sample etc complete as per the detailed drawing & Instruction of EIC. Make: Terrene / ecosoft / moldo make
Maple wood flooring : Supply, installation & finishing of Sundek Air Cush wooden sports flooring system consisting of: The Surface board: Kiln Seasonel imported Maple wood (Sycamore) surface board finished with 21mm thick ,50 to 110 mm width and in random length in tongue and groove shape. The edges of the boards will have a finger lock grove and the bottom side with air pass groove and applied with polyurethane lacquer. The Under Frame: Made of commercial quality Fir /Spruce /Pine wood runners of 90/70mm x 45 mm treated with anti-termite solution and fixed on the bottom side with 10 mm thick ai-cushining pads by nails through the two wings at 300 mm clc.The installation: A vapour barrier of 6ml (600 micron) thick will be placed on the leveled IPS sub-floor before laying the under frame. The runners having air cell cushioning pads will be placed on the vapour barrier in perfect level at 300mm clc in one direction. The surface boards will be screwed to the runners through the tongue only and will lock the screwed tongue by the groove of the adjoining boards. The ends of the board will be locked by inserting the wooden fingers through the edge grooves and fixed with suitable adhesive. An expansion gap of 8 to 10 mm will be left open between the wooden flooring the surrounding tile area/wall .The finishing: After installation the floor will be machine sanded in uniform level and finished with imported (Loba-Germany) non-skid DIN certified polyurethane lacquer .Game line marking will be carried out in required colors before applying the finish coat. work complete including all type of fittings, fixing, fixtures, accessories, tools, tackles, scaffolding , anchoring, silicon seal, epoxy grouting, insets plates, at all floor, all level, all depth, all Height, all lead and lift, mock up sample etc complete as per the detailed drawing & Instruction of EIC. Make: Terrene / ecosoft / moldo make
Vinyl flooring : 6.5 mm thick Providing and laying of minimum 6.5mm thick Vinyl sports flooring of as per approved make and shade for as specified Sports flooring shall be internationally approved and certified by according world federation. Flooring shall be laid on existing levelled, clean and dry surface and as per manufacture’s guideline. Joint between two sheets shall be weld with welding rod match with shade of floor surface and by not welding system. Marking sports ground lines shall be painted with approved shade paid and in required length / width according to game standard. The floor can be glued directly on suitable subsurface or installed to the stabilizing underlay every lay with a suitable adhesive. Technical characteristics in accordance with the EN 14904 standard. Specifications: - Total Thickness: 6.5 mm Wear Layer Thickness: 0.45/0.8 mm Weight: 3.39/4.48 g/m' Roll Width: 1.8 m Roll Length: 15/20 m Impact Resistance 28 N/M Abrasion Resistance : 7 ≤ 10 mm Indentation Resistance : ≤ 0.6 mm Sound Insulation: 20 - 30 db Ball Bounce: ≥ 98% CERTIFIED: BWF – ITTF – ITF. work complete including all type of fittings, fixing, fixtures, accessories, tools, tackles, scaffolding , anchoring, silicon seal, epoxy grouting, insets plates, at all floor, all level, all depth, all Height, all lead and lift, mock up sample etc complete as per the detailed drawing & Instruction of EIC. Make: Terrene / ecosoft / moldo make
Providing and fixing of Gym Rubber mat flooring tiles of size of 508x508 mm and in thickness 10 mm , non - interlocking type of Vulcanized virgin rubber of design and colour approved by the engineer incharge. work complete including all type of fittings, fixing, fixtures, accessories, tools, tackles, scaffolding , anchoring, silicon seal, epoxy grouting, insets plates, at all floor, all level, all depth, all Height, all lead and lift, mock up sample etc complete as per the detailed drawing & Instruction of EIC.
Interlock PP (Polypropylene) Tile : Providing and fixing of Interlock PP (Polypropylene) Tile flooring of size of 304.8mmx304.8x15mm ( 12"x12"x15.5mm) and in thickness 15 mm of design and colour approved by the engineer incharge. Compression : Bearable load 2500 N Resistance Colour : Multicolour Environmnental protection :-100 % recyclable material High UV Resistant Anti Aging , 10 years Warranty Temprature: 40" to 80" work complete including all type of fittings, fixing, fixtures, accessories, tools, tackles, scaffolding , anchoring, silicon seal, epoxy grouting, insets plates, at all floor, all level, all depth, all Height, all lead and lift, mock up sample etc complete as per the detailed drawing & Instruction of EIC.
Laminated Wooden flooring : Providing and fixing laminated wooden flooring as per approved make & Sample by Architect. A ) Plank Locking System ; L2C , B ) Thickness of Plank :8 MM C ) Density of Plank :850-900 kg / m3 , D ) Environmentlly Friendly Certificate for Wooden Flooring :Blue Angle Certificate , E ) Use Classifications AC4-32 , F ) International Fire Classifications BFL-S1 G ) Warranty 20 Years , H ) Size of Plank 188 MM X 1220 MM wooden planks laying on base floor and interlocked with approved make of tile adheshive , and 3 mm under lay material as per suggestion by manufacturers instruction . as per detailed drawing or instruction of architect. Work shall be carried under supervision of specialist, matching with surrounding levels etc. Total job finished with where ever required end profile and skirting as per instructions of EIC. Thickness : 8 MM , Basic rate of Carpet is Rs.200/Sq.ft
Carpet Flooring Work: Providing & laying carpet flooring as per approved make & Sample by Architect. A ) Carpet Tile Yarn : 100 % Stainproof SDN ( Solution Dyed Nylon ) , B ) Yarn Weight : 18 0z/ SYD or 510 gm/ C ) Size of Tile : 25 CM X 100 CM , D ) Thickness of Tile 6 MM , E ) Backing of Tile NexBac ( Bitumem) F ) Total Weight of Tile 3800 Gms SQ MT , G ) Use Classifications Heavy Commercial (SANS 10361) /33(EN1307) H ) International Fire Classifications :2 (SANS 10177-4) (EN30501) (ISO9239) (ASTM E 648-08) I ) Guarantee 5 Years .Carpet fixed with SR 505 Pidilite or equivalent tile adhesive and underlay foam material. carpet should be laid as closure to each other.Contractor will take care for level matching with other area flooring. Scope includes labour, under lay material, disposal of debris, necessary cutting of tiles without damaging the edges, including to provide & fixing of SS 304 finish end profile , skirting ,edge profile etc to protect and cleaning, etc. complete. All works are carried as per detail drawing / instruction of architect / EIC. Before laying carpet contractor shall prepare even surface as per required. basic rate of carpet is Rs. 220/ Sq.ft
Carpet Flooring Work: Providing & laying carpet flooring as per approved make & Sample by Architect. A ) Carpet Roll Yarn 100 % Olefin ( Solution Dyed ) , B ) Yarn Weight 23 0z/ SYD or 650 gm/ SQ MT C ) Stitch Rate 42/10 CM D ) Thickness of Tile 6 MM E ) Density Of Yarn 165480/sqm F ) Static Generation <3KV(AATC-134)G ) Use Classifications Commercial H ) International Fire Classifications (ASTM D 2859-Pass 8/8) I ) Guarantee 5 Years J ) Size of Roll 3.66 MT X 30 MTS - 35 MTS Carpet fixed with SR 505 Pidilite or equivalent tile adhesive and underlay foam material. carpet should be laid as closure to each other.Contractor will take care for level matching with other area flooring. Scope includes labour, under lay material, disposal of debris, necessary cutting of tiles without damaging the edges, including to provide & fixing of SS 304 finish end profile , skirting ,edge profile etc to protect and cleaning, etc. complete. All works are carried as per detail drawing / instruction of architect / EIC. Before laying carpet contractor shall prepare even surface as per required. basic rate of carpet is Rs. 110/ Sq.ft
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Woody ACP Cladding: Providing and fixing 3 mm thick ACP sheet ( Woody finish- PVDF coating - 0.25 mm top layer) with necessary framing work of aluminium alloy 6005 T5 Size as per design. Spacer Tape , wood screw , silicone sealant ,including all type of fittings , accessories etc complete. Including cost of all type of tools, tackles, all labour, scaffolding etc. Including cost of all type of materials, transportation. Including cost of cleaning etc. Work complete for at all floor, all level, all depth, all Height, all lead and lift etc. work complete as per the detailed drawing,grooves , approved sample, specifications and instruction of Architect/EIC. The whole work is to be executed with a guarantee of 10 years. Sample mock shall be approved from Architect/EIC. Basic rate ACP sheet Rs. 160/ sq.ft.
Alluminium Perforation sheet facade : Providing Fabrication & erection of 2 mm thick Exterior grade pure Alluminium sheet with perforation & as per reference image given by Architect. The work includig necessary Alluminium fittings/ framing, fixtures, accessories, cutting, engraving etc complete. The scope includes Scaffolding, loading, transportation, unloading and delivery and erection site of all fabricated structures, alignment and welding of all structures true to line, level, plumb and dimension. sample mock shall be approved from Architect/EIC.Shop drawing shall be provided by Contractor. MS fabrication, perforation, cnc cutting shall be paid by Separate item
M.S. Art : Providing Fabrication & erection of 4 to 6 mm thick MS plate with CNC cutting/Engraving as per reference image given by Architect. The work includig necessary fabrication work, fittings, fixtures, accessories etc complete. Finish : Anti corrosive paint with primer as per approved shade by Architect. The scope includes loading, transportation, unloading and delivery and erection site of all fabricated structures, alignment and welding of all structures true to line, level,plumb and dimension. sample mock shall be approved from Architect/EIC.Shop drawing shall be provided by Contractor.
ACP fins Louvers : Supply and fixing of of Alstone make ACP FIN LOUVERS Panel 3 MM 0.25 COIL THICKNESS , 100 X 50 X 100 (50 mm front & 100 mm depth) with Exterior woodenCoatedon panel with 10 years of warranty. Work complete including all type of Z aluminium profile for Back supporting system , hardware, fittings , fixtures as per instruction of Client/Archtect etc. Rate including all type of scaffolding, safety measures, form work at all floor, all levels etc. complete per detailed drawings and specifications, sample mock shall be approved from architect / client.
Tensile fabric canopy (Swimming Pool) : Design, fabrication and installation of Tensile fabric Canopy using steel structure, white/Colored Fabric of 1050 GSM with both side PVDF coating as per approved sample by Architect with Base plate, Anchor bolts, steel column, stiffner plate, GI wire rope, nut etc complete. - Tensile Roofing Structure With 1050 GSM SIOEN (Beljium) PVC + PVDF + FR + Flumax Coated Fabric.- 15 Yrs* Warranty - Structure Finish - Sand blasting + 1 Coat Epoxy Primer & 2 Coat Epoxy Paint. Work complete: Including cost of all type of tools, tackles, scaffolding, all labour, materials, transportation, machinaries, Crane, equipment, Finishing, all type of fabrication & steel work (including epoxy paint), accessories,. Work complete for at all floor, all level, all depth, all Height, all lead and lift etc. work complete as per the Detailed specification, shop drawing , approved sample, instruction of Architect/EIC. Sample mock shall be approved from Architect/EIC. Roof plan area shall be measured for payment.
Sky Light: Providing and fixing Sky light 2 mm thick UV coated polycarbonate sheet or acrylic modified Ultra Violet Stabilized fiber glass panels as per approved material by Architect/Client. Including cost of all type of tools, tackles, scaffolding, all labour, materials, transportation, Finishing, all type of fabrication & steel work with paint, accessories , silicon sealent ,. Work complete for at all floor, all level, all depth, all Height, all lead and lift etc. work complete as per the Detailed specification, shop drawing , approved sample, instruction of Architect/EIC. Sample mock shall be approved from Architect/EIC.Plan area shall be measured for payment.
Turbo Air Ventilator : 600 mm Dia Providing and fixing 600 mm dia Automatic grade Turbo Air Ventilator as per approved material by Architect/Client. Thickness minimum 0.5mm thick, Material: Aluminium. The Connecting assembly shall have high quality permanently lubricated and sealed ZZ- steel ball bearings. The bearings shall not be exposed to dust etc. It shall be ensured that the ventilator head is perpendicular to the ground. Including cost of all type of tools, tackles, scaffolding, all labour, materials, transportation, Finishing, all type of fabrication & steel work with paint, accessories , silicon sealent ,. Work complete for at all floor, all level, all depth, all Height, all lead and lift etc. work complete as per the Detailed specification, shop drawing , approved sample, instruction of Architect/EIC. Sample mock shall be approved from Architect/EIC.
Fabrication work : Designing , Supplying, fabricating, assembling, hoisting and fixing in position to alignments & levels as per approved drawings, structural steel work in-built up for cantilever portion/roof top/pipe racks/mezzanine/columns etc. with booms etc., to detail welded (welding as specified by the structural consultant) / bolted constructions comprising R.S. joists, channels, angles, plates or any MS rolled section including necessary permanent rivets, bolts & nuts, handling straightening, cutting, making holes, shop / site assembly, erection, (including preparation of template) transport to site, storing, etc., and painting with shop/site of primer coat prior to erection and two or more coats of first quality Epoxy paint of Asian make or approved equivalent and quality etc. ( Painting Procedure : Providing and applying paint of Asian make or equivalent and desired shade, including the preparation surface (with emery paper 180 and wipe clean) by thoroughly cleaning all dust, dirt, applying red oxide oil primer (of Asian paint Code. 0005/0006 by brush or spray) and putty of (Asian paint paste filler code. 0016 by putty knife blade) again sand papering of (emery paper 180 and wipe clean) again applying primer (of Asian paint Code. 0005 by brush or spray), again sand papering of (emery paper 320 and wipe clean) levelling rubbing the surface, to be free from undulation/ waviness, applying 1 coat zinc chromate Yellow primer & 2 coat Synthetic enamel paint) at all heights below and above highest plinth level, scaffolding / staging, as required complete as directed. (Payment will be made on the basis of standard section weights for net weight erected in position excluding rivets, temporary bolts, etc., but payment will be made for permanent bolts, nuts and washers.) Contractor shall submitt Shop drawing for all items for approval of Architect/ EIC.
Sink Cock: Providing and fixing 15mm dia. Sink Cock as per approved make list and work complete including all type of accessories . Model equivalent to Jaquar code FLRCHR-5347N
Miniature Scale Model (RRU Campus): The Contractor shall design, procure, and install a physical model of the Building and site layout with the approval of the Architect showing the topography, road network, building blocks, elevation features, landscape area, open spaces and other existing features at site. This model would be installed at the designated location in the site.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal dia Pipes
Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
S.C.I. gully or nahani grating 100 mm dia
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32mm dia
Providing & Supplying of Class SN8 structured wall Polythelene piping systems (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External Annular corrugated and smooth internal surfaces (Double Wall) for non pressure underground Sewerage & Drainage application as per EN:13476-3 incuding all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the departmental stores etc. complete (ID Dia). Pipe Dia. ID 100mm
Providing & Supplying of Class SN8 structured wall Polythelene piping systems (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External Annular corrugated and smooth internal surfaces (Double Wall) for non pressure underground Sewerage & Drainage application as per EN:13476-3 incuding all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the departmental stores etc. complete (ID Dia). Pipe Dia. ID 150mm
Providing & Supplying of Class SN8 structured wall Polythelene piping systems (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External Annular corrugated and smooth internal surfaces (Double Wall) for non pressure underground Sewerage & Drainage application as per EN:13476-3 incuding all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the departmental stores etc. complete (ID Dia). Pipe Dia. ID 200mm
Providing & Supplying of Class SN8 structured wall Polythelene piping systems (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External Annular corrugated and smooth internal surfaces (Double Wall) for non pressure underground Sewerage & Drainage application as per EN:13476-3 incuding all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the departmental stores etc. complete (ID Dia). Pipe Dia. ID 250mm
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up tohaunches of S.W. pipes including bed concrete as per standard design : 100 mm diameter S.W. pipe
150 mm diameter S.W. pipe
200 mm diameter S.W. pipe
250 mm diameter S.W. pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 ( 1 cement : 4 coarse sand) including 500x450mm pre-cast RCC horizontal grating with frame complete as per standard design : With common burnt clay FPS (non modular) bricks of class designation 7.5
Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 ( 1 cement : 4 coarse sand) including 500x450mm pre-cast RCC horizontal grating with frame complete as per standard design : With common burnt clay FPS (non modular) bricks of class designation 7.5
Providing & erecting water cooler having storage capacity 150 Ltr. & cooling capacity 150 Ltr.per hour @ an ambient temp of 450 C. The outlet temp. of the water should drop by 150C within a hour, The water cooler should be comprising of hermetically sealed compressor, fan motor, condensing unit, water tank surrounded by evaporating, coil, thermostats, relay etc.complete with necessary inlet & outlet connection. The body of water cooler will be made from Stainless Steel.
Supplying & erecting 5 stage single reverse osmosis water purification system with M.S. powder coated frame, prefilter housing with 'O' ring presediment filter GAC filter, carbon filter suitable buster DC pump capacity 80 psi, mention with 40 Osg inline type post carbon filter auto low & high pressure switches with following size of storage tank & LPH capacity & erected as directed with one year comprehensive maintenance guarantee. [C] 50 Ltr / Hr with 250 psi 2 nos booster pump
Supply, Installation, Testing & Commissioning of SPLIT HEAT PUMP Power Supply : 220V/440V/1Ph/3Ph/50Hz , Tank, Compressor, Heating Element, Sound Level : <50 dB Refrigerant Type : R410a, Outer Body Material : Prepainted Steel, Inner Tank Material : Glass Lined MS Tank, Max Water Pressure : 0.8 Mpa, Defrosting : Auto, Water Proof Grade : IPX4, Insulation Thickness : PUF - 50mm, Emerson Expansion valve. Hot Water Circulation pump. with Multi-function digital control panel. Max. Temp. 60 C. Operating ambient condition -5 c to 45 c. 50 db a low noise level. complete with all required accessories to complete the job with Valves & Piping. Capacity of 500 LPH. Complete with Recirculation pumps, control panel, accessories etc to complete the job.
HYDRO PNEUMATIC SYSTEM FOR DOMESTIC WATER DISTRIBUTION Variable Speed Hydro-booster System : Compact self contained Hydro-booster system comprising of following : In-line, vertical multistage, centrifugal clear water pumps with SS-304 casing, S.S 304 impeller and SS-304 shaft, C.I. Base CED coating & head TEFC motor (with mechanical seal) Vendor to submit performance curves and technical catalogue of the proposed model for review and information. The job shall include required size of Foot valve, Inlet Pipe, Outlet Pipe, Y Strainer, NRV, Inlet & Outlet Valves, Main Header Header, Pressure Valve, and all required accessories to complete the job. Panel mounted PLC based multi pump controller with large graphical display with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a single body or as separate components with pressure sensor transmitter, IP 55 enclosure, diodes to indicate pump ready, pump running and fault condition. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition. System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status. Electronic type low water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required), with probe & all control wiring from Panel to tank to operate the system automatic/manual & shall prevent the pump from dry running. Scope shall also include power and control cable of required size, termination, cable tray from Pump to Control panel etc. complete the job. Pre-charged diaphragm pressure vessel with interchangeable membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc. complete (size of pressure vessel shall be as per manufacturer recommendation). Set of accessories such as GI headers of suction and discharge for (working and stand by pump assembly), control valves, non return valves, pressure switches, pressure transducers, pressure gauge etc. complete the job. Domestic Water Supply Distribution PUMP: Capacity per pump - 150 LPM 1 Set = 1 Nos. Pump (1 Working + 1 Standby - cascade operation) Total Capacity of System: 300 LPM Head - 40 mt Location - Pump Room Suction head - Negative Suction
WTP Feed Supply Distribution PUMP: Capacity per pump - 55m3 1 Set = 1 Nos. Pump (1 Working + 1 Standby - cascade operation) Head - 20 mt Location - Pump Room Suction head - Negative Suction
Irrigation Supply Distribution PUMP: Capacity per pump - 250 LPM 1 Set = 1 Nos. Pump (1 Working + 1 Standby - cascade operation) Total Capacity of System: 500 LPM Head - 40 mt Location - Pump Room Suction head - Negative Suction
Supply, installation, testing & commissioning of Sewage Treatment Plant with SS screen, collection tank, primary, secondary & tertiary treatment, ,sludge recirculation pump, air blower & diffuser,dosing pump, Media, required all accessories, etc complete the job. also with all electromechanical equipments, interconnected UPVC SCH 80 piping for water, SS piping for air, valves, pumps, instruments, gauges, electrification like panel IP 55, ON-OFF and Trip Indicating lamps in each incomer and outgoing feeders, adequate NO NC contacts for integrating with Building Automation System, interlocking arrangement, level controller with operational mode as one pump working at low level, starter, cabling, earthling, etc. complete. The sizing of tank/equipment shall take care of average as well as peak flow. All pump and blower shall be (1W+1S) except dosing pump. The outlet parameters shall be as per reuse in Gardening requirment. MBBR Process. This shall be inclusive of civil work of all process tanks (Raw sewage coarse screen chamber with raw equalization tank, Sewage Treatment Unit & treated water tank) considering invert level of last manhole.The trasportation charges,Erection, commisinning for entire STP,all electro mechnical equipments with loading & unloading shall ne inclusive of this estimate. For any changes/modification - shall be completed as per direction of Engineer in Charge. Capacity: 1 MLD Inlet Water Water Parameters: PH: 6.5-8.5 Total Suspended Solids:200 BOD: 250-350 COD: 350-500 Oil & Grease: 50 Outlet Water Water Parameters: PH: 6.5-8.5 Total Suspended Solids:10-20 BOD: <10 COD: <50
Providing, erecting, testing commissioning & getting Plan Approval as well as NOC from Electrical Inspector for extensible H.T panel comprising of Single Breaker 630/800A. H.T. VCB Drawout type VCB confirming as per I.S. for use on 11 KV, 3 phase, 50 c/s. unearthed A.C. supply system having breaking rupturing capacity of 350 MVA complete with spring operated mechanism, mechanically & automatic ON-OFF and spring mechanism charged, discharged indicators, ON-OFF mechanical push button, operation counter necessary auxiliary switches, closing shunt trip, air insulated busbar chamber having heat shrinkable PVC sleeves, mechanical interlocks safety shutters, isolating plugs and a VCB trolley with three vacuum interrupters with epoxy support insulators and self aligning finger type isolating contacts. The breaker shall be Manual cum motorised mechanism & auto spring charge with TNC switch closing with following accessories. Following test are to be conducted at site during conmmissioning before charging of vcb panel. As per Single Line Diagram & Technical Specification. 1. 144 mm. square flush mounting type digital multifunctional meter with communication facility 2. Power Factor Meter 3. Double core current transformer cast resin type having ratio as per SLD for metering & second core for protection having required class of accuracy. 4. Instantaneous under voltage relay& Temperature rise Tripping Relay 5. Electrical closing coil & short trip coil operating on 110V. D.C.- Three Sets 6. Auxiliary relay for anti pumping device 7. Three phase Three limb Drawout type feeder connected & output of 200 VA cast resin insulated potential transformer having ratio 12000V./110V. and 200 VA Burdon with 0.5 accuracy. 8. Common Alarm bell operating on 110V A.C. 9. Digital KWH Meter 10. Cable boxes suitable up to 11 KV 3core 300 sq.mm XLPE cable. 11. 230V. A.C. to 110V. D.C. power pack for closing & tripping circuit common. 12.Breaker ON-OFF, Auto trip and spring charged indicators. 13.Phase indicating & panel illumination lamps with plug socket 14.Numerical Communicable type non directional O/C & E/F Relay with a setting of 5-250% both in O/C & E/F. complete with necessary interconnection with air insulated high grade copper busbar {Breaker Testing scope include Closing Time, Opening Time, VCB Hi-Pot test at Site}{ Relay Testing Scope Include testing of all protection by three phase testing kit at site }(VCB Trolley is to be provided) Following test are to be conducted at site during conmmissioning before charging of vcb panel. 1) IR value 2) Checking of mechanical and electrical operation and control circuit 3) Testing of CT and relay with primary injection. 4) Setting of relay as per the site requirement. 5) Testing of transformer auxiliary relays.
HT CABLE: Supply, Laying and commissioning of following size 11KV(E) grade XLPE insulated for cables, FR PVC outer sheathed, steel strip/ wire armored aluminum/copper conductor, underground cable. The cable shall conform to IS 7098, Part-II with latest amendments and technical specifications attached with this BOQ. 3C X 300sq.mm, AL. XLPE ARM. CABLE.
HT CABLE TERMINATION: supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: 300 sq. mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: 300 sq. mm
Supply and Fixing of 250mm Dai MS Exhaust Pipe of suitable size for 1250 KVA DG sets cladded with 50mm thick Glass wool insulation covered with 24 SWG Aluminium sheet and provided with rain cap& fixing accessories Complete as required.
Supply and fabrication of supports for Residential silencer/ exhaust pipe made out of MS channels/angles including cutting, welding and fabrication to the required size and painting with 2 coats or more of anti corrosive paint and 2 coats or more of synthetic enamel paint of Grey/ Black colours complete as required
Comprehensive AMC for DG Set after Defect Liability Period 1st Year after DLP
2nd Year after DLP
3rd Year after DLP
4rth Year after DLP
5th Year after DLP
Transformer & Accessories: Providing, erecting, testing & commissioning approved make oil immersed ONAN cooled, double wound, core type indoor / outdoor copper wound 11KV/ 433V step down transformer with RTCC Panel of following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed system continuously rated for a full temperature rise in oil not exceeding 45 Deg.C.at maximum ambient temp. of 50 Deg. C. complete with necessary radiator first filling of new transformer oil & standard fitting as below complying with IS 1180( Part 1 ):2014 standards with energy efficiency level 2 ON load tap changing range steps +2.5% to -5% on H.V for variation should be provided. The H.V. shall be connected Delta & Secondary with star connection. The transformer should have cable-end boxes on H.T. side suitable for up to 3 core 300 sq.mm. XLPE cable & on L.T. side suitable for 1600 Amp 4P, 50KA Busduct bus duct as per requirement complete with test certificates from manufacturers. 1. Oil conservator with filling Hole & Cap - One No. 2. Thermometer pocket with 6" dial type thermometer switch alarm & trip contacts- Two nos. 3. Silica-gel breather with charge- One No. 4. Plain oil level gauge - One No. 5. Drain / Sampling / Filter valve- One No. 6. Top Filter Valve - One No. 7. Explosion vent with Diaphragm - One No. 8. Rating & Diagram plate - One No. 9. Additional neutral bushing for earthing - One No. 10. Bi directional Roller - Four Nos. 11. Earthing terminals - Two Nos. 12. Lifting lugs - Two Nos. 13. Air release plug. - One No. 14. Double float buchholz relay with Alarm and trip contacts. 15. Control cable as required from Transformer to VCB Panel is to be provided with necessary connection to VCB relays for protection. OLTC with Motorized Mechanism configured to RTCC Panel. as per IS 1180 level-1 (e) 1000 KVA Max. allowable loses at 50 % of rated load is 2.79 KW and at full load is 7.77 KW Cat.III Following test are to be conducted at site during commissioning before charging of transformer. 1) IR value of transformer (HV-E, LV-E) 2) Turn ratio test on all tap positions 3) Magnetic balance test. 4) Conformation of vector group. 5) Checking of electrical and mechanical operation OLTC and RTCC and control circuits for local and remote. 6) Testing of transformer oil (BDV test) and filling of oil. 7) Checking of tranformer auxiliary realy, buchlz, wti and oti, mog, osr.(With setting of WTI and OTI) 8) Checking for oil leakage.
Supply, Installation, Testing & Commissioning of Main LT Panel as per SLD & Specification. Incomer : 1600Amp, 4P, 50KA Microprocessor based Electrical Draw Out ACB, LSIG Protection : 2 Nos Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram. Mechanical Electrical Interlocking between Incomers. Busbar Chamber : 2000Amp, 4P, Copper Busbar, 50KA. Outgoing : 1600Amp, 4P, 50KA Microprocessor based Electrical Draw Out ACB, LSIG Protection - 2 Nos 800Amp, 4P, 50KA Microprocessor based Electrical Draw Out ACB, LSIG Protection - 2 Nos 400Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 2 Nos 250Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 2 Nos Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram. 25KVAR Fixed Capacitor Bank for Transformer as per SLD. SPD as per SLD. Input Terminal for Transformer RTCC Panel.
Design, Supplying, installing, testing of factory fabricated ready made Three phase APFC Panel Cubical Panel fabrication should be type tested as per IEC 61921, 61439:1&2 Capacitor Duty Contactor for switching as per following Steps Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection,Copper tinned insulated Busbar,Cubical panel should be indoor type with IP 43 and IK 10,Metalized polypropylene film tye3-phase 550Volt Capacitor,De tuning Reactor for each capacitor,Panel having Short Circuit and Overload protection,Each step Capacitor having suitable MCB with Sc, OL, internal earth fault relay,Each stage having Stage Contactor (Capacitor load rating),PF regulator master controller having suitable steps with LCD display, Rs 485 Communication port, Indication LED Lamps for main incomer and ON-OFF for each capacitor bank,MS Chanel for Floor mounting, Cable entry as per site situation,Cooling fans for panel 420 KVAR Capacitor Panel as per SLD & Specification. (100 KVAR - 3 Nos + 50 KVAR - 1 Nos + 25 KVAR - 2 Nos + 10 KVAR - 2 Nos) as per SLD & Specification. Capacitor Bank : Datar, L&T, Power Matrix, Switchgear Makes : L&T, Schneider, Legrand
Supplying, Installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Bus Trunking Class F Multilayer PET Insulaltion, for use on 3 Phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP=67rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel duly powder coated in convenient sections complete with 4 nos Aluminium bus bars at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. Make : L&T, Schneider, Legrand 1600 A, Isc = 50KA for 1 Sec
Supply, Installation, Testing & Commissioning of RRU Sports Complex Main Panel as per SLD & Specification. Incomer : 1600Amp, 4P, 50KA Microprocessor based Electrical Draw Out ACB, LSIG Protection : 1 Nos Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram. Busbar Chamber : 2000Amp, 4P, Copper Busbar, 50KA. Outgoing : 630Amp, 4P, 50KA Microprocessor based Electrical Draw Out ACB, LSIG Protection - 4 Nos 400Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 4 Nos 250Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 4 Nos 125Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 6 Nos 100Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 6 Nos 63Amp, 4P, 25KA MCCB - 4 Nos Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram.
Supply, Installation, Testing & Commissioning of RRU Sports Complex HVAC Panel-1&2 as per SLD & Specification. Incomer : 630Amp, 4P, 25KA Microprocessor based Electrical Draw Out ACB, LSIG Protection : 1 Nos Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram. Busbar Chamber : 800Amp, 4P, Aluminium Busbar, 50KA. Outgoing : 63Amp, 4P, MCB. 10KA - 24 Nos Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram.
Supply, Installation, Testing & Commissioning of RRU Sports Complex HVAC Panel-3 as per SLD & Specification. Incomer : 250Amp, 4P, 25KA Microprocessor based MCCB, LSIG Protection - 1 Nos Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram. Busbar Chamber : 300Amp, 4P, Aluminium Busbar, 25KA. Outgoing : 160Amp, 4P, 50KA Microprocessor based MCCB, LSIG Protection - 4 Nos Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram.
Supply, Installation, Testing & Commissioning of RRU Sports Complex Ventilation Panel as per SLD & Specification. Incomer : 160Amp, 4P, 25KA Microprocessor based Electrical Draw Out ACB, LSIG Protection : 1 Nos Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram. Busbar Chamber : 160Amp, 4P, Aluminium Busbar, 25KA. Outgoing : 63Amp, 4P, MCB. 10KA - 12 Nos Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram.
Supply, Installation, Testing & Commissioning of RRU Sports Complex Lighting & Power Panel-1 &2 as per SLD & Specification. Incomer : 400Amp, 4P, 25KA Microprocessor based MCCB, LSIG Protection - 1 Nos Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram. Busbar Chamber : 500Amp, 4P, Aluminium Busbar, 25KA. Outgoing : 63Amp, 4P, MCB. 10KA - 16 Nos Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram.
Supply, Installation, Testing & Commissioning of Plumbing Panel as per SLD & Specification. Incomer : 200Amp, 4P, 25KA Microprocessor based MCCB, LSIG Protection - 1 Nos Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram. Busbar Chamber : 300Amp, 4P, Aluminium Busbar, 25KA. Outgoing : 63Amp, 4P, MCB. 10KA - 8 Nos Protection Relays, Indication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door
8 way , Double door
12 way , Double door
16 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
8 way (4 + 24), Double door
12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Single pole and neutral
Double pole
Triple pole
Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required. Supplying and fixing 20 A, 240 V, SPN Industrial type socket
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Earthing with copper earth plate 600mm X 600mm X 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover (A)(approved make OEM has to submit test certificate including value of earth resistance of installation duly stamped and signed by agency and officer Incharge has to ensure the value of earthing resistane mentioned in test Certificate) & having back filling compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing compound should be capable to retain moisture for long time Necessary test report must be submitted by Agency. [C] For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant & Sensitive Computer System(like Automation, SCADA)i.e. independent Earthing located in other than normal soil i.e. Soft Rock, Marshy Soil etc.. -Length of Pipe : 3 Mtrs. -Back filling Compound :2 nos Bags of 25 Kg.
Supplying and laying 75 mm X 12 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 75 mm X 12 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 50 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (A) 3 1/2 core 25 Sq. mm ( 16 Sq. mm 1/2 core)
(B) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core)
(C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core)
(E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core)
(F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core)
(G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core)
(H) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core)
(I) 3 1/2 core 240 Sq. mm( 120 Sq. mm 1/2 core)
(J) 3 1/2 core 300 Sq.mm ( 150 Sq. mm 1/2 core)
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (A) 4 core 16 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cable. (A) 3 core 2.5Sq. Mm
(B) 3 core 4 Sq. mm
(C) 3 core 6 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables. (A) 4 core 2.5 Sq. mm
(B) 4 core 4 Sq. mm
(C) 4 core 6 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables. (A) 4 core 10 Sq. mm
(B) 4 core 16 Sq. mm
(C) 4 core 25 Sq. mm
(D) 8 core 2.5 sq.mm
(G) 12 core 2.5 sq.mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 6 sq. mm (19mm)
2 X 10 sq. mm (19mm)
2 X 16 sq. mm (22mm)
2 X 25 sq. mm (22mm)
2 X 35 sq. mm (25mm)
2 X 50 sq. mm (28mm)
3 X 10 sq. mm (22mm)
3 X 16 sq. mm (25mm)
3 X 25 sq. mm (25mm)
3 X 35 sq. mm (28mm)
3 X 50 sq. mm (32mm)
3 X 70 sq. mm (35mm)
3 X 95 sq. mm (38mm)
3 X 120 sq. mm (45mm)
3 X 150 sq. mm (50mm)
3 X 185 sq. mm (57mm)
3 X 225 sq. mm (62mm)
3 X 240 sq. mm (62mm)
3 X 300 sq. mm (70mm)
3½ X 25 sq. mm (28mm)
3½ X 35 sq. mm (32mm)
3½ X 50 sq. mm (35mm)
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (45mm)
3½ X 150 sq. mm (50mm)
3½ X 185 sq. mm (57mm)
3½ X 225 sq. mm (62mm)
3½ X 240 sq. mm (62mm)
3½ X 300 sq. mm (70mm)
3½ X 400 sq. mm (82mm)
4 X 10 sq. mm (25mm)
4 X 16 sq. mm (28mm)
4 X 25 sq. mm (28mm)
4 X 35 sq. mm (32mm)
4 X 50 sq. mm (35mm)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
225 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
375 mm width X 50 mm depth X 2.0 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
300 mm width X 62.5 mm depth X 2.0 mm thickness
375 mm width X 62.5 mm depth X 2.0 mm thickness
450 mm width X 62.5 mm depth X 2.0 mm thickness
600 mm width X 62.5 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
900 mm width X 62.5 mm depth X 2.0 mm thickness
600 mm width X 75 mm depth X 2.0 mm thickness
750 mm width X 75 mm depth X 2.0 mm thickness
900 mm width X 75 mm depth X 2.0 mm thickness
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
UPS SYSTEM: Supplying and erecting approved make online Un-interruptible Power Supply system comprising flat cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF batteries. The charger having operating capacity for input 160-270V AC & inverter having output 230V,50 Hz Ac with 0.8 load power factor with battery, over/under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with following power backup.with MS painted batteries stand, 10% Overload capacity for momentary load. (J) 20 KVA 3 - phase with 1Hr Backup
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan box.
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with proper insulation without leakage and earthing.
Providing and erecting iron clad cable route marker duly marked with ELE.CABLE of size 23 cm.X 12 cm. Flushed with ground in cement foundation as directed by Engineer in charge.
Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across the road crossing or on floor with necessary material in an approved manner and making the ground as per original.(D) 300 mm dia
Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or required depth for laying any size of cable or locating the fault all over the run and back filling the same and making the surface as normal ground.
Covering of cable with second class bricks or cement tiles laid cover the cable crosswise & also on both sides with covering of 7. 5 Cm. layer of sand above & below cable (16 bricks per meter)
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground/ road surface for enclosing cable (A)50 mm outer dia
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable (B)63 mm outer dia
Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for treatment of person suffering from Electric shock with minimum 50" diagonally size.
Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply.
Supplying rubber matting of following thickness as per IS:15652/IEC 61111 (c)12mm
Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes)
Supplying FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and Red out side with FIRE mark, filled with dry-sand and kept on existing stand provided or hung on wall hook.
Supplying and erecting floor mounting stand for keeping four nos. of FIRE buckets comprising 1500 mm in length, 900 mm height frame made out of 30mm X30 mm X 4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of approved enamelled silver paint.
Wall hook 22 to 25 cms. projection for keeping fire buckets made out of 15 mm dia. M.S rod grouted in wall to a depth of minimum 15 cms.
"Supply Installation Testing Commisioning of Indoor Recessed 4FT Techzone luminaire light 30W. luminaire Dimensions should be strictly with (1195mm X 95mm X 65mm) 1. Fixture must be made of high grade single piece Extruded Aluminium housing for rapid thermal healing & Powder coated by electrostatically applied corrosion resistant Nano coating technology. 2. The Luminaire System should have an efficacy of >100LPW. 3. The fixture must be provided with a injection moulded UV stabilized Polystyrine Diffuser ,ensuring low glare & best in class uniformity. 4.power factor > 0.95, THD <10%, with inbuilt surge protection of 4KV L-L, with Additonal 6KV/10KA IP67 SPD surge protection or higher with all necessary safety protection eg. mis-wiring, Over voltage, Short circuit, Reverse Polarity protection, Input over Voltage cut-off at 320V with Auto Recovery feature. 6. Fixture should be made in india 7. must be available in Neutral White color temperature (4000K) , CRI > 80, SDCM<3. LEDs must have a life of 50000 burning hrs. & Lumen maintenance as per L70. 8. Light Engine PCB should be Metal Core PCB made of high grade Al 5052 with not less than 70 micron copper thickness & 2 W/mk thermal conductivity for better performance & thermal management. IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab. Fixture/Fitting needs to be approved by the architect before installation The product should be Manufactured in India (all the Components should be manufactured in India except the Led source which can be imported . (Approved Led source Nichia , Cree, Lumileds , Osram Only). Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva"
Supply Installation Testing Commisioning of Indoor Office Lighting 2x2 Fixture 35-38w with below specifications 1. Single Pressure die cast Aluminum alloy housing for better thermal conductivity and extremely low weight . 2. LEDs must have a life of 50000 burning hrs. & Lumen maintenance as per L70, The Luminaire System should have an efficacy of >125 LPW 3. CRI>80, High efficiency driver with inbuild surge protection, over voltage protection, short circuit protection and operating at >0.9 PF. <5% THD 4. The fixture must be provided with a injection moulded UV stabilized Polycarbonate Diffuser ,ensuring low glare & best in class uniformity 5. Light Engine PCB should be Metal Core PCB made of high grade Al 5052 with not less than 70 micron copper thickness & 2 W/mk thermal conductivity for better performance & thermal management. IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab. The product should be Manufactured in India (all the Components should be manufactured in India except the Led source which can be imported . (Approved Led source Nichia , Cree, Lumileds , Osram Only). Fixture/Fitting needs to be approved by the architect before installation Approved Make.: WIPRO/TISVA/HAVELLS/LIGHTING TECHNOLOGIES/PHILIPS"
Supplying and erecting LED indoor fittings with Integral, SMD LED, 40 W, IP65, 40W Surface t mounted totally enclosed LED luminaire with System efficacy of more than 100 lm/W (4000 lumens). LED luminaire shall be made up of Sturdy vandal resistant polycarbonate body with polyurethane gasket. The luminaire shall have LED grade UV stabilized polycarbonate diffuser. The luminaire shall have Sturdy polycarbonate clips for fixing diffuser to housing. The luminaire shall have Waterproof cable gland ensuring good ingress protection. LM 80-08 compliant LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Everlite Taiwan / Osram Germany should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire manufacturer shall produce certificate of association with LED manufacturer for minimum five years. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be CRCA constructed, Isolated type, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 3 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 The product should be Manufactured in India (all the Components should be manufactured in India except the Led source which can be imported . (Approved Led source Nichia , Cree, Lumileds , Osram Only). Fixture/Fitting needs to be approved by the architect before installation Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva
Any kind of Decorative Light Fixtures type ( with Basic Rate of Rs.25,000/-) ( Range Above 18,500 Rs to up to 35,000 Rs) Fixture/Fitting needs to be approved by the architect before installation Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva,EGLO
"Supply Installation Testing Commisioning of decorative Pendant Lamp lamp light 10-15w with below features Enclosure Material :steel Enclosure Colour :satin nickel Glass/Shade Material :wood, glass Glass/Shade Colour : maple, white Dimmenssions: Height (in mm): 1500, DIA : (in mm): 500, Wattage: 10-15w Output : 900-1300Lms Holder type: E27 Fixture should be more the IP20 rated Ref : eglo 96214 TINDORI Fixture/Fitting needs to be approved by the architect before installation Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva,eglo
Supply Installation Testing Commisioning of Indoor Recessed 2FT Techzone luminaire light 10W. luminaire Dimensions should be strictly with 595mm X 95mm X 65mm 1. Fixture must be made of high grade single piece Extruded Aluminium housing for rapid thermal healing & Powder coated by electrostatically applied corrosion resistant Nano coating technology. 2. The Luminaire System should have an efficacy of >100LPW. 3. The fixture must be provided with a injection moulded UV stabilized Polystyrine Diffuser ,ensuring low glare & best in class uniformity. 4.power factor > 0.95, THD <10%, with inbuilt surge protection of 4KV L-L, with Additonal 6KV/10KA IP67 SPD surge protection or higher with all necessary safety protection eg. mis-wiring, Over voltage, Short circuit, Reverse Polarity protection, Input over Voltage cut-off at 320V with Auto Recovery feature. 6. The product should be Manufactured in India (all the Components should be manufactured in India except the Led source which can be imported . (Approved Led source Nichia , Cree, Lumileds , Osram Only). 7. must be available in Neutral White color temperature (4000K) , CRI > 80, SDCM<3. LEDs must have a life of 50000 burning hrs. & Lumen maintenance as per L70. 8. Light Engine PCB should be Metal Core PCB made of high grade Al 5052 with not less than 70 micron copper thickness & 2 W/mk thermal conductivity for better performance & thermal management. Fixture/Fitting needs to be approved by the architect before installation Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva
Supply Installation Testing Commisioning of Indoor cove mounted Heavy 18X18mm corner 45degree customized Extruded Aluminium alloy Housing and polycarbonate diffuser profile for continous decorative illumination Anodised aluminium end caps firmly fixed on the aluminium extrusion Silver anodised finish for elegant look . Efficacy of Fixture >=100 Lumens/Watt suitable for self adhesive Strips with driver. Wattage should be 14-17w/m Should have a dotless continuos effect. Should be operated using remote driver of 24V Dc kept at suitable locations for future maintainance. Quantity in metres Fixture/Fitting needs to be approved by the architect before installation Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva"
Supply of Led NEON BENDABLE FLEX IP67, 3000K CCT, 120LEDs/M, DC24/12VDC, 10W/M, double-layer , with Aluminium housing and required accessaries with Following specifications . ( quantity in metre) 5000 x 12x20mm , 5M per reel, Minimum delivered lumen output 450lm per meter, MacAdam≤ 3, CRI ≥ 90, R9-50, ON -OFF REMOTE DRIVER, 5 Yrs warranty. THD < 10% Bendable in both directions, flexible dot free and perfectly homogeneous linear LED light line, Encapsulated with premium water proof sealing, UV resistance Comprises of Strip with LED, Non dimmable power supply, all mounting and installation accessories. Dimensions: L:5000mm, W: 12mm, H: 20mm Fixture/Fitting needs to be approved by the architect before installation Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva
"Supply Installation Testing Commisioning of outdoor cylinder Light 28W-32w Surface Mounted COB Spotlight downlighter with below features Pressure die cast Aluminum alloy housing for better thermal conductivity. Powder coated using Nano technology for longer durability. PS diffuser for optimum light transmission. Efficacy of Fixture above 95 Lumens /watt Available with 5700K, 4000K & 3000K CCT. CRI>80 High efficiency driver with inbuild surge protection, over voltage protection, short circuit protection and operating at >0.9 PF. <5% THD. Tiltable. LED life of 50000 Hrs @ L70. IP65 Protection Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. The product should be Manufactured in India (all the Components should be manufactured in India except the Led source which can be imported . (Approved Led source Nichia , Cree, Lumileds , Osram Only) PF >=0.95 and THD <=5 % (Certificate need to be submitted from NABL Accredited lab) The manufacturer should be ISO 9001 -2008 and ISO 14001 -2004 Company The manufacturer should have their own driver Manufacturing Facility. The manufacturer should have their own NABL accredited lab Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva"
Supplying and erecting approved make Conical Pole (Standard ) Made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759 with required base plate and integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable terminationas erected on suitable foundation (included) with necessary nut-bolts/J-Bolts. as per details given by manufacturer considering site requirement.The length of poles are as below (D) 6 Mtr. Long 65mm Top X155 mm bottom dia, 3mm thickness.
"Supply Installation Testing Commisioning of Outdoor surface mounted light 4-6w with below features Material : Cast Aluminium Enclosure Colour :black Dimmenssions: Height (in mm): 50, Length : (in mm): 200, Wattage: 4-6w Fixture should be more the IP44 rated Ref : eglo 98707 BRIANZA Fixture/Fitting needs to be approved by the architect before installation Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva,eglo
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump). Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 LPM at 70m Head
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 LPM at 35m Head
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 200 mm. dia (wall thickness = 6.3 mm)
150 mm. Dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 40mm dia
50mm dia
65mm dia
80mm dia
200mm dia
250mm dia
300mm dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 40mm dia
50mm dia
65mm dia
80mm dia
100mm dia
150mm dia
200mm dia
250mm dia
300mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 40mm dia
50mm dia
65mm dia
80mm dia
100mm dia
125mm dia
150mm dia
200mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 80mm dia
100mm dia
150mm dia
200mm dia
250mm dia
300mm dia
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe
4 way - 150 mm dia M.S. Pipe
3 way - 150 mm dia M.S. Pipe
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Upright Sprinkler
Horizontal side wall sprinkler
Concealed sprinkler
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 80mm dia
100mm dia
150mm dia
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 700mm
Supplying, installation, testing & commissioning of deluge valve (to be used for water curtains) UL listed with wet pilot basic trim assembly for DVA with test and alarm, drip and drain valve with water motor gong complete as required. 50mm dia
80mm dia
100mm dia
150mm dia
Providing, installation, testing & commissioning of water curtain nozzle 15mm dia nickel chrome plated brass, BSPT, K-factor as per design consideration complete as required.
Providing, installation, testing & commissioning of electric release trim assembly for deluge wall with two way solelnoid valve, weather proof operation on 24 volts DC supply complete as required.
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
Providing & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc., ISI Marked portable fire extinguisher, 4.5 kg CO2 type fire extinguishers complete in all respect including initial fill and wall suspension brackets & shall conform to IS 2878
Providing & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc., ISI marked Fire Extinguisher, Dry Chemical powder type capacity 6 kgs conforming to IS : 2171 including first fill & wall suspension bracket.
Charges for Liasoning with CFO and getting all approvals and permissions & NOC 's required for fire fighting at various stages & after completion of the project. (All official and receipted payments would be submitted and Re- imbursed) Taking approval /NOC form CFO
Supplying, installation, testing & commissioning of Photo luminescent non toxic, non radioactive, maintenance free self glowing exit signs comprising zinc sulphide chargeable crystals which can glow in dark; printed on U-1000 photo luminiscent aluminium sheet 1.0 mm thick containing luminiscent 111 as base chemical cover with UV stabilized coating job complete with SS screws for wall mounting or to be hanged on rust proof chain for ceiling mounting complete in all respects, plate size 12" X 18" (general size, may increase or decrease depending on site requirements). Make : Pro-lite, Supreent Creation, Auto-Glow, Agni
TRIPUR BUILDERS
Bhumi Procon Private Limited
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid