Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹40.0 L+₹2.8 L (7.54%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹41.1 L+₹3.9 L (10.5%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹41.5 L+₹4.4 L (11.7%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance L4 | |
| 5 | L5₹41.6 L+₹4.4 L (11.9%)Rejected-Finance SHREE NIVAS LIMDA LANE JAMNAGAR GUJARAT PIN 361001 | JAMNAGAR | GUJARAT | 361001 | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | M/s SK Traders L1 | rajengineers L7 | jagdish machinery stores L4 | Chamunda Kruparefrigeration L8 | SURESH ELECTRICALS L2 | Sukhi Electricals L6 | M/s super construction L5 | High Tech Consruction L3 | Vikas Electircal Works L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Deployment of tools / equipment for Comprehensive load testing of HOT/EOT gantry crane of capacity 0.3 Ton to 3 Ton carrying out (once in a completion period of contract) complete all specified as directed by Engineer in Charge.
Note for item No 1& 2:-
(i) Required load for testing of crane will be provided by the contractor under his own arrangement.
(ii) Load testing shall be carried out in presence of user and MES rep . Contractor shall produce certificate after load testing for the same duly signed by user | 26 | JOB | 6,000 ₹1,56,000 | 7,000 ₹1,82,000 | 6,800 ₹1,76,800 | 7,260 ₹1,88,760 | 5,000 ₹1,30,000 | 6,500 ₹1,69,000 | 6,200 ₹1,61,200 | 7,500 ₹1,95,000 | 3,000 ₹78,000 Lowest |
| 2.00 | Deployment of tools / equipment for Comprehensive load testing of HOT/EOT gantry crane of capacity 5 Ton to 10 Ton carrying out (once in a completion period of contract) complete all specified as directed by Engineer in Charge.
Note for item No 1& 2:-
(i) Required load for testing of crane will be provided by the contractor under his own arrangement.
(ii) Load testing shall be carried out in presence of user and MES rep . Contractor shall produce certificate after load testing for the same duly signed by user | 14 | Job | 8,000 ₹1,12,000 | 8,300 ₹1,16,200 | 8,250 ₹1,15,500 | 10,000 ₹1,40,000 | 9,650 ₹1,35,100 | 7,500 ₹1,05,000 | 8,400 ₹1,17,600 | 6,000 ₹84,000 | 3,500 ₹49,000 Lowest |
| 3.00 | Comprehensive maintenance of HOT/ EOT gantry crane of capacity 0.3 Ton to 3 Ton, cleaning,greasing & oiling of component, checking of serviceability of all component complete all specified as directed by Engineer in Charge.
Note for item No3 & 4
(i) Replacement of unserviceable Spare part will be measured & paid separately under respective item of Schedule
(ii) Servicing of item shall be carried out by skilled technician or any OEM/ its authorised Service provider
(iii) Necessory T & P required for servicing deemed to be included in the quoted rate | 26 | EACH JOB | 8,000 ₹2,08,000 | 8,300 ₹2,15,800 | 8,500 ₹2,21,000 | 10,000 ₹2,60,000 | 9,500 ₹2,47,000 | 7,500 ₹1,95,000 | 8,000 ₹2,08,000 | 7,286 ₹1,89,436 | 6,500 ₹1,69,000 Lowest |
| 4.00 | Comprehensive maintenance of EOT gantry crane of capacity 5 Ton to 10 Ton,cleaning , greasing & oiling of component, checking of serviceability of all component, complete all specified as directed by Engineer in Charge.
Note for item No3 & 4
(i) Replacement of unserviceable Spare part will be measured & paid separately under respective item of Schedule
(ii) Servicing of item shall be carried out by skilled technician or any OEM/ its authorised Service provider
(iii) Necessory T & P required for servicing deemed to be included in the quoted rate | 26 | Job | 10,000 ₹2,60,000 | 11,000 ₹2,86,000 | 12,000 ₹3,12,000 | 14,840 ₹3,85,840 | 13,220 ₹3,43,720 | 9,500 ₹2,47,000 Lowest | 10,800 ₹2,80,800 | 11,500 ₹2,99,000 | 14,000 ₹3,64,000 |
| 5.00 | Material and labour for changing of OEM recommended gear oil of EOT crane of capacity 0.3 to 10 ton after draining out old oil cleaning of gear box etc complete all specified as directed by Engineer in Charge. | 300 | LITRE | 170 ₹51,000 | 215 ₹64,500 | 220 ₹66,000 | 150 ₹45,000 | 146 ₹43,800 Lowest | 200 ₹60,000 | 200 ₹60,000 | 225 ₹67,500 | 180 ₹54,000 |
| 6.00 | Supply and fixing in replacement of Thruster Flame proof seed- O 23/5 complete all specified as directed by Engineer in Charge. | 1 | EACH | 20,000 ₹20,000 | 25,000 ₹25,000 | 18,000 ₹18,000 | 21,361 ₹21,361 | 26,000 ₹26,000 | 17,500 ₹17,500 | 22,000 ₹22,000 | 16,000 ₹16,000 | 700 ₹700 Lowest |
| 7.00 | Supply and fixing in replacement of Thruster non Flame proof 18 Kg complete all specified as directed by Engineer in Charge. | 1 | Each | 18,000 ₹18,000 | 22,000 ₹22,000 | 15,000 ₹15,000 | 20,000 ₹20,000 | 14,000 ₹14,000 Lowest | 19,500 ₹19,500 | 17,500 ₹17,500 | 16,350 ₹16,350 | 25,000 ₹25,000 |
| 8.00 | Supply and fixing in replacment of Flame proof limit switch 2 Way lever type complete all specified as directed by Engineer in Charge. | 1 | Each | 20,000 ₹20,000 | 18,000 ₹18,000 | 15,000 ₹15,000 Lowest | 19,500 ₹19,500 | 16,020 ₹16,020 | 24,500 ₹24,500 | 25,000 ₹25,000 | 19,218 ₹19,218 | 15,000 ₹15,000 Lowest |
| 9.00 | Supply and fixing in replacment of Push button Yellow /Blue complete all specified as directed by Engineer in Charge. | 10 | Each | 150 ₹1,500 | 225 ₹2,250 | 200 ₹2,000 | 120 ₹1,200 Lowest | 175 ₹1,750 | 250 ₹2,500 | 205 ₹2,050 | 210 ₹2,100 | 450 ₹4,500 |
| 10.00 | Supply and fixing in replacement fo NO/NC contact complete all specified as directed by Engineer in Charge. | 10 | Each | 100 ₹1,000 | 160 ₹1,600 | 150 ₹1,500 | 120 ₹1,200 | 80 ₹800 Lowest | 300 ₹3,000 | 138 ₹1,380 | 125 ₹1,250 | 250 ₹2,500 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Jul 2025, 6:00 pmClosed
Lt Col Sumukh Swaroop
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No 1 Jamnagar 361003
REPAIR / PREVENTIVE MAINT OF EOT CRANE, BOOM BARRIER WITH OTHER MISC ITEMS UNDER GE (AF) JAMNAGAR NO 1
2025_MES_718031_1
8356/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
JAMNAGAR
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No 1
₹80,000
Yes
12 Sept 2025
2 Jul 2025
24 Jul 2025
2 Jul 2025
23 Jul 2025
16 Jul 2025
Amount
Deployment of tools / equipment for Comprehensive load testing of HOT/EOT gantry crane of capacity 0.3 Ton to 3 Ton carrying out (once in a completion period of contract) complete all specified as directed by Engineer in Charge. Note for item No 1& 2:- (i) Required load for testing of crane will be provided by the contractor under his own arrangement. (ii) Load testing shall be carried out in presence of user and MES rep . Contractor shall produce certificate after load testing for the same duly signed by user
Deployment of tools / equipment for Comprehensive load testing of HOT/EOT gantry crane of capacity 5 Ton to 10 Ton carrying out (once in a completion period of contract) complete all specified as directed by Engineer in Charge. Note for item No 1& 2:- (i) Required load for testing of crane will be provided by the contractor under his own arrangement. (ii) Load testing shall be carried out in presence of user and MES rep . Contractor shall produce certificate after load testing for the same duly signed by user
Comprehensive maintenance of HOT/ EOT gantry crane of capacity 0.3 Ton to 3 Ton, cleaning,greasing & oiling of component, checking of serviceability of all component complete all specified as directed by Engineer in Charge. Note for item No3 & 4 (i) Replacement of unserviceable Spare part will be measured & paid separately under respective item of Schedule (ii) Servicing of item shall be carried out by skilled technician or any OEM/ its authorised Service provider (iii) Necessory T & P required for servicing deemed to be included in the quoted rate
Comprehensive maintenance of EOT gantry crane of capacity 5 Ton to 10 Ton,cleaning , greasing & oiling of component, checking of serviceability of all component, complete all specified as directed by Engineer in Charge. Note for item No3 & 4 (i) Replacement of unserviceable Spare part will be measured & paid separately under respective item of Schedule (ii) Servicing of item shall be carried out by skilled technician or any OEM/ its authorised Service provider (iii) Necessory T & P required for servicing deemed to be included in the quoted rate
Material and labour for changing of OEM recommended gear oil of EOT crane of capacity 0.3 to 10 ton after draining out old oil cleaning of gear box etc complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of Thruster Flame proof seed- O 23/5 complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of Thruster non Flame proof 18 Kg complete all specified as directed by Engineer in Charge.
Supply and fixing in replacment of Flame proof limit switch 2 Way lever type complete all specified as directed by Engineer in Charge.
Supply and fixing in replacment of Push button Yellow /Blue complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement fo NO/NC contact complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of contactor 22 Amp complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of contactor 16 Amp complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of contactor 12 Amp complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of contactor 9 Amp complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of wire rope 12mm suitable for EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of liner for Disk brake for Flame proof EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of Disc brake drum dia 200mm Flame proof EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of Auxiliary contact block 1 NO /1 NC Make Siemens for EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of VFD drive 1 HP for EOT Crane complete all specified as directed by Engineer in Charge. Make Yaskawa or equivalent as approved by GE.
Supply and fixing in replacement of VFD drive 3 HP for EOT Crane complete all specified as directed by Engineer in Charge. Make Yaskawa or equivalent as approved by GE.
Supply and fixing in replacement of VFD drive 7.5 HP for EOT Crane complete all specified as directed by Engineer in Charge. Make Yaskawa or equivalent as approved by GE.
Supply and fixing in replacement of Emergency stop Push butoon 1 NC for EOT crane complete all specified as directed by Engineer in Charge.Make Siemens/Legrand/Havels/CG
Supply and fixing in replacment of Brake shoe with liner (Dia 100MM) for EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of Brake shoe with liner (Dia 150MM) for EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacment of Brake shoe with liner (Dia 160MM) For EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of Brake shoe with liner (Dia 200MM) for EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of Torque spring (100MM) for EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of Torquespring (150MM) for EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of Torque spring (160MM) for EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of Torque spring (200MM) for EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of Rectifier 24 V DC for EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of Transformer 500 KVA -110V for EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of MS cable trolley 4 bearing for C Track for EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing PVC cable trolley for EOT crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of LED red indication lamp 110V for EOT Crane complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of non flame proof liver type limit switch complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of Disk Brake 9 coil 415 V AC for EOT crane complete all specified as directed by Engineer in Charge.
S&F in repair /replacement of Flame proof Pendent for EOT crane of capacity upto 10 ton 8 way push button with indicator complete all specified as directed by Engineer in Charge.
Supply and fix in repair single phase preventer for EOT crane & connecting complete all specified as directed by Engineer in Charge.
Dismantling & Refixing of wire rope of EOT/HOT crane from Rope Drum of capacity of 0.3 ton to 10 ton connecting complete all specified as directed by Engineer in Charge. (Note -Checking of wire for its strenghing capacity and serviceability of steel wire rope.)
S&F in repair flexible control cable, PVC insulated, PVC sheathed with multistranded, copper conductor, of size 4 sqmm 4 core, suitable for EOT crane & connecting complete all specified as directed by Engineer in Charge.
S&F in repair flexible control cable, PVC insulated, PVC sheathed with multistranded, copper conductor, of size 1.5 sqmm 16 core, suitable for EOT crane & connecting complete all specified as directed by Engineer in Charge.
M&L for 1 HP capacity electric motor of EOT crane, AC 3 phase, by dismantling the motor and taking out the old winding wires, cleaning the slots, rewinding the motor with appropriate size of super enamelled copper winding wire, and varnishing complete including replacing the worn out bearing reassembling the motor fixing in same position and testing complete all specified as directed by Engineer in Charge.
M&L for 3 HP capacity electric motor of EOT crane, AC 3 phase, by dismantling the motor and taking out the old winding wires, cleaning the slots, rewinding the motor with appropriate size of super enamelled copper winding wire, and varnishing complete including replacing the worn out bearing reassembling the motor fixing in same position and testing complete all specified as directed by Engineer in Charge.
M & L and labor for removing the gear box of EOT crane of any capacity drain out the gear oil , ,replacement of unserviciable parts , gas cutts,oil seal and refixing to original position ,testing on full load complete all specified as directed by Engineer in Charge.
Supply and fix inreplacement of PCB suitable for EOT crane of any make / model capacity upto 10 Ton complete all specified as directed by Engineer in Charge.
Supply and fix in repair technical manual MCB Changeover switch for boom barrier, two way centre off, Four pole,40 A, 415 V - 50 Hz, rated impulse voltage 4 KV fixed in existing panel & connecting complete all specified as directed by Engineer in Charge.
Supply and fix in repair of complete Mother Board, comprising control board of boom barrier, Limit switch interface, radio receiving interface complete as per existing sample all specified as directed by Engineer in Charge.
Supply and fix in repair MCB 63 Amp, Four Pole, breaking capacity 10 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all specified as directed by Engineer in Charge.
Supply and fix in repair MCB 32/40 Amp, Four Pole, breaking capacity 10 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all specified as directed by Engineer in Charge.
S&F in repair LED Traffic signal light, 24W, viewing angle 23°,high intensity, ,polycarbonate body with IP65 protection, fire retardant, glass epoxy,FR4 printed circuit board with protection cover and clear polycarbonate concave lenses, input voltage 210-240V,working temperature -40°C to 80°C in colour indication of Green/Red for giving signal to move or stop for vehicle/person fixed on existing pole complete all specified as directed by Engineer in Charge. Make:- Nucleonics / Trafitronics or equivalent approved by GE
METREial and labor to attending complaints in EOT/HOT crane, locating faults ,caliberating controller panel and replacement of unserviceable parts , control wiring and components in EOT/HOT crane upto 10 Ton and testing on completion , complete all specified as directed by Engineer in Charge. Note: The quoted rate includes the following: (a) Taking down of unserviceable parts. (b) Any minor repair, replacement of minor parts such as screws, gasket, nuts, bolts, washers, cleaning .
Supply and fixing in replacment of Water pump suitable for 320 KVA DG set complete all specified as directed by Engineer in Charge. Make of DG Set Greaves Model no TBD2V12MK-II
Supply and fixing in replacement of Turbocharger suitable for 320 KVA DG set complete all specified as directed by Engineer in Charge. Make of DG Set Greaves Model no TBD2V12MK-II
Supply and fixing in replacement of Fuel injuncition pump suitable for 320 KVA DG Set including calliberation complete all specified as directed by Engineer in Charge. Make of DG Set Greaves Model no TBD2V12MK-II
Supply and fixing in replacement of injunctor nozzile complete all specified as directed by Engineer in Charge suitble for 320 KVA DG set Make of DG Set Greaves Model no TBD2V12MK-II
Supply and fixing in replacement of actuator suitable for 320 KVA DG set complete with calliberation complete all specified as directed by Engineer in Charge.Make of DG set Greaves Model no TBD2V12MK-II
Supply and fixing in replacement of thermostate vavle suitable for 320 KVA DG set Make of DG set Greaves Model no TBD2V12MK-II complete all specified as directed by Engineer in Charge.
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings; floor mounted with PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with all accessories complete all specified as directed by Engineer in Charge comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 200 Amps for phases and 150 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment.(ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches.(iv) Panel board internal wiring with suitable rated PVC insulated copper conductors. (v) Onload changeover switch 125 Amps,415V, 4 Pole,-01 No (In coming) (vi) MCCB 100 Amps, 415V, 4 pole, 16 KA - 01 Nos (Out going) (vi) MCCB 63 Amps, 415V, 4 pole, 16 KA - 01 Nos (Out going)
Dismantling of alternator assembly complete from DG set of capacity from 10KVA to 400 KVA and removing the burnt out copper winding cleaning of limb thoroughly and rewinding the same with super enamelled copper winding wire of the same gauge and turn with proper class of insulation impregnated & baking, assembling and testing complete all specified as directed by Engineer in Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 METRE wide and not exceeding 1.5 METRE deep for laying/taking out of cables and foundation of poles etc. and getting out, complete all specified as directed by Engineer in Charge.
Returning, filling in trenches (soil), including spreading, levelling and well ramming in layers not exceeding 25 cm thick, complete all specified as directed by Engineer in Charge.
Removal of surplus excavated soil to a distance not exceeding 50METRE and depositing where directed at a level not exceeding 1.5METRE above the starting point, complete all specified as directed by Engineer in Charge.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment complete all specified as directed by Engineer in Charge.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150mm x 40mm complete all specified as directed by Engineer in Charge.
Laying only old un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150mm x 40mm complete all specified as directed by Engineer in Charge.
Taking out / down old existing LT 1100 volt grade cables of size 25 Sqmm 4 Core size, aluminium conductor, XLPE, armoured, removal to store for re-use or for credit, complete all specified as directed by Engineer in Charge. Note : Excavation shall be measured and paid for separately
All as per Serial Item No. 68 here-in-before but 35 Sqmm 3.5 Core size complete all specified as directed by Engineer in Charge.
All as per Serial Item No. 68 here-in-before but 50 Sqmm 3.5 Core size complete all specified as directed by Engineer in Charge.
All as per Serial Item No. 68 here-in-before but 70 Sqmm 3.5 Core size complete all specified as directed by Engineer in Charge.
All as per Serial Item No. 68 here-in-before but 95 Sqmm 3.5 Core size complete all specified as directed by Engineer in Charge.
Relaying, jointing, testing and commissioning, already taken out existing LT under ground cables XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor cross sectional area 25 Sqmm 4 Core size, 1100 volts grade, laid in trenches, along poles or passing through pipes or laid under floor or through/on walls etc, complete all specified as directed by Engineer in Charge.
All as per Serial Item No.73 here-in-before but 35 Sqmm 3.5 Core size complete all specified as directed by Engineer in Charge.
All as per Serial Item No. 73 here-in-before but 50 Sqmm 3.5 Core size complete all specified as directed by Engineer in Charge.
All as per Serial Item No.73 here-in-before but 70 Sqmm 3.5 Core size complete all specified as directed by Engineer in Charge.
All as per Serial Item No. 73 here-in-before but 95 Sqmm 3.5 Core size complete all specified as directed by Engineer in Charge.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated and armoured, heavy duty, electric power cable, cross sectional area 25 Sqmm 4 Core size aluminum conductor 1100volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all specified as directed by Engineer in Charge. Note: Returning filling & removal of earth, sand cushioning and bricks for protection of cable shall be measured and paid separately.
All as per Serial Item No. 78 here-in-before but 35 Sqmm 3.5 Core size complete all specified as directed by Engineer in Charge.
All as per Serial Item No. 78 here-in-before but 50 Sqmm 3.5 Core size complete all specified as directed by Engineer in Charge.
All as per Serial Item No.78 here-in-before but 70 Sqmm 3.5 Core size complete all specified as directed by Engineer in Charge.
All as per Serial Item No. 78 here-in-before but 95 Sqmm 3.5 Core size complete all specified as directed by Engineer in Charge.
Supply and laying / fixing , GI pipe light grade 80 mm bore for cable protection fixed to pole/wall or laid under floor/road /pavement, including flat iron clamp, nut, bolt, wahser etc of required size and taking out old & removal, complete all specified as directed by Engineer in Charge. Note: Boring of holes under road etc. shall be measured and paid separately.
All as per item No 83 here - in before but GI pipe 50mm complete all specified as directed by Engineer in Charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 2/4 core, 16 to 25 Sqmm complete all specified as directed by Engineer in Charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 35/50 Sqmm complete all specified as directed by Engineer in Charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 70/95 Sqmm complete all specified as directed by Engineer in Charge.
Supply and fixing in replacement of HT insulation mate of size not less than 2m x 1m x 20 mm complete all specified as directed by Engineer in Charge.
SURESH ELECTRICALS (BID ID -3366950)
High Tech Consruction (BID ID -3368921)
jagdish machinery stores (BID ID -3365914)
M/s super construction (BID ID -3367876)
Sukhi Electricals (BID ID -3367056)
rajengineers (BID ID -3364276)
Chamunda Kruparefrigeration (BID ID -3365970)
Vikas Electircal Works (BID ID -3368139)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .