Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹409.7 CrAccepted-AOC | ₹409.7 Cr | L-1 | Accepted-AOC Quoted L-I Amount against the Tender |
| 2 | L-2₹446.4 CrRejected-Finance 626 6TH FLOOR DLF TOWER A DLF TOWER 626 6TH FLOOR DLF TOWER A JASOLA JASOLA SOUTH DELHI DELHI 110076 | SOUTH DELHI | DELHI | 110076 | ₹446.4 Cr | L-2 | Rejected-Finance Not Quoted L-1 price |
| 3 | L-3₹451.9 CrRejected-Finance | ₹451.9 Cr | L-3 | Rejected-Finance Not Quoted L-1 price |
| 4 | L-4₹530.9 CrRejected-Finance NCC HOUSE MADHAPUR HYDERABAD 500081 TELANGANA INDIA TELEPHONE 040 23268730 | ₹530.9 Cr | L-4 | Rejected-Finance Not Quoted L-1 price |
| 5 | L-5₹663.7 CrRejected-Finance 1ST FLOOR KRISHNA TOWERS OPP TO THRIKKAKARA TEMPLE THRIKKAKARA P O COCHIN 682 021 | ERNAKULAM | KERALA | 682021 | ₹663.7 Cr | L-5 | Rejected-Finance Not Quoted L-1 price |
Tender Value
₹344.5 Cr
EMD Value
₹5 Cr
Closing Date
11 Jul 2023, 11:00 amClosed
Chief Engineer (MM)
O/o Chief Engineer (MM), HPSEBL, Vidyut Bhawan, Shimla-04
Loss Reduction Works under RDSS for North Zone
2023_HPSEB_73671_1
CE(MM)/RDSS-(P-2)/North Zone
Open Tender
Electrical Works
730 days
North Zone of HPSEBL
As per Standard Bidding Document of RDSS
11 documents required · 11 mandatory
₹1,475
Sr. Account Officer, Banking, Vidyut Bhawan
₹5 Cr
O/o Chief Engineer (MM), Vidyut Bhawan, Shimla-04
27 Jul 2024
22 May 2023
11 Jul 2023
22 May 2023
11 Jul 2023
10 Jun 2023
29 May 2023
Amount
AB Cabling works ,33KV,22KV,11KV & LT Line overhead Line Ab Cabling & other Cabling Works as per technical specification, approved drawings and scope of work.
LT AB Cable
LT AB Cable on poles [Size: (3x95 Sq, mm ) +70sqmm (Insulated) +16 sqmm{Inclusive 3% sagging & wastage)
LT AB Cable on poles [Size: (3x95 Sq, mm ) +70sqmm +16 sqmm{Inclusive 3% sagging & wastage)
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Stay Set Complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Full Clamp for stay
Anchoring Assembly for LT
Suspension Assembly for LT
Facade Hooks for LT
Distribution box 3 phase 5 connectors as per TS
Piercing Connector as per TS
Cable for SMDB 3.5Core X 35sqmm
LT Earthing set complete (preferbly coil earthing)
Red Oxide
Aluminium paint
LT AB Cable on poles [Size: (3x185mm²) +150 Sqmm (Insulated)+16 sqmm {Inclusive 3% sagging & wastage)
LT AB Cable on poles [Size: (3x185mm²) +150 Sqmm (Insulated)+16 sqmm {Inclusive 3% sagging & wastage)
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Stay Set Complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Full Clamp for stay
Anchoring Assembly for LT
Suspension Assembly for LT
Facade Hooks for LT
Distribution box 3 phase 5 connectors as per TS
Piercing Connector as per TS
Cable for SMDB 3.5Core X 35sqmm
LT Earthing set complete (preferbly coil earthing)
Red Oxide
Aluminium paint
HT Cabling
11kv HT AB Cable 3x95+70 Sq. mm {Inclusive 3% sagging & wastage)
HT AB Cable on poles [Size: (3x95 +70 Sq, mm,Insulated ) {Inclusive 3% sagging & wastage)
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Stay Set Complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Full Clamp for stay
X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
Half Clamp for Cross Arm
Anchoring Assembly for HT
Suspension Assembly for HT
Facade Hooks for HT
Heat Shrinkable Straight Through Jointing Kit
Cable Termination kit
T-Jointing kit
HT Earthing set complete (preferbly coil earthing)
Red Oxide
Aluminium paint
11kv HT AB Cable on poles [Size: (3x185+150 Sq, mm ) {Inclusive 3% sagging & wastage)
HT AB Cable on poles [Size: (3x185 Sq, mm+150 Sqmm Insulated) {Inclusive 3% sagging & wastage)
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Stay Set Complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Full Clamp for stay
X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
Half Clamp for Cross Arm
Anchoring Assembly for HT
Suspension Assembly for HT
Facade Hooks for HT
Heat Shrinkable Straight Through Jointing Kit
Cable Termination kit
T-Jointing kit
HT Earthing set complete (preferbly coil earthing)
Red Oxide
Aluminium paint
Underground Cable XLPE
11kv HT XLPE Cable underground cableing work {Inclusive 1% sagging & wastage)(size-3x120sqmm
11 kV XLPE armoured Cable [Size: (3x120 mm²) {Inclusive 1% wastage)]
11 kV Cable Straight Through Jointing Kit [Size: 3x120 mm²]
11 kV Cable Outdoor Termination Kit [Size: 3x120 mm²]
11 kV Cable Heat Shrink Outdoor Termination Kit [Size: 3x300 mm²]
RCC Hume Pipe Dia-150 mm [Length- 2 M]
Collar RCC Hume Pipe 150 mm
RCC cable cover (2 feet long)
Sand Bag (50 Kg)
Route and Joint indicating stone
Inspection Chamber
GI Pipe earthing 40 mm x 2.5/3 m 'B' class
Pipe HDPE Size 150 mm
Lug AL Crimping 70 SQMM XLPE Single HOLE
Flat GI Size 25x6 mm
Cleat HDPE for Cable Support
G.I. Pipe 100 mm DIA 'B' CLASS
Flat GI Size 50x6 mm
Channel MS Size 75x40x6 mm
Conversion LT to HT
LT to 11kv New Line on Steel Tubular Pole with Dog Conductor -100 Sq. mm
ACSR 6/1/4.72 {Includes 3 conductor lengths for 3Φ and Inclusive 3% (Sag, Jumpering and wastage}
11M Steel Tublar Pole (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures)
Muffs with concerete filling
Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ∆ Formation
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete (REC Constr. Stand. J-1)
Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
Eye Hook for earth wire
Earth Wire Clamp
MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro' structure: 2 No ]
Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro' structure: 2 No]
Danger Plate
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
LT to 11kv New Line on Steel Tubular Pole with Rabbit Conductor -50Sq. mm
ACSR 6/1/3.35 (50mm²) {Includes 3 conductor lengths for 3Φ and Inclusive 3% (Sag, Jumpering and wastage}
11M Steel Tublar Pole (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures)
Muffs with concerete filling
Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ∆ Formation
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete (REC Constr. Stand. J-1)
Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
Eye Hook for earth wire
Earth Wire Clamp
MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro' structure: 2 No ]
Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro' structure: 2 No]
Danger Plate
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
HVDS-New HT Line works as per Scope of Works
11kv HT AB Cable on poles [Size: (3x185+150 Sq, mm ) {Inclusive 3% sagging & wastage)
HT AB Cable on poles [Size: (3x185 +150 Sq, mm Insulated) {Inclusive 3% sagging & wastage)
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Stay Set Complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Full Clamp for stay
X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]
Half Clamp for Cross Arm
Anchoring Assembly for HT
Suspension Assembly for HT
Facade Hooks for HT
Heat Shrinkable Straight Through Jointing Kit
Cable Termination kit
T-Jointing kit
HT Earthing set complete (preferbly coil earthing)
Red Oxide
Aluminium paint
11kv New Line on STP with rabbit Conductor -50 Sq. mm
ACSR 6/1/3.35 (50mm²) {Includes 3 conductor lengths for 3Φ and Additional 1% (Sag, Jumpering and wastage}
STP 11 Mtr Long
Muffs with concerete filling
Cross Arm: [Channel Iron (125x65x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure
Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron: 125x65x6, Length: 2340 mm x 2 No.] ∆ Formation
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (2 No./Run Thro & 5 No. / Dead End)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete (REC Constr. Stand. J-1)
Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
Eye Hook for earth wire
Earth Wire Clamp
MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
Half clamps: [On Double Pole Dead End structure: 6 No, Run Thro' structure: 1 No]
Full clamps: [On Double Pole Dead End structure: 4 No, Run Thro' structure: 3 No]
Danger Plate (250X200X1.6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
11kv New Line on Steel Tubular Pole with Dog Conductor -100 Sq. mm
ACSR 6/1/4.72 {Includes 3 conductor lengths for 3Φ and Inclusive 3% (Sag, Jumpering and wastage}
11M Steel Tublar Pole (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures)
Muffs with concerete filling
Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ∆ Formation
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete (REC Constr. Stand. J-1)
Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
Eye Hook for earth wire
Earth Wire Clamp
MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro' structure: 2 No ]
Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro' structure: 2 No]
Danger Plate
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
Supply ,Installation and commissioning of New DT as per scope of work
Distribution Transformer 10KVA
Distribution Transformer (Ordinary), 11/0.4 kV, 10KVA
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit 11KV
Lightening Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
LT Distribution Panel Box with MCCB(50A, 25 kA, 4P)
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Barbed Wire
LT Cable (3.5 Core) 35 mm²
Red Oxide
Aluminium Paint
Distribution Transformer 16 KVA
Distribution Transformer (Ordinary), 11/0.23 kV, 16 KVA
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit 11KV
Lightening Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
LT Distribution Panel Box with MCCB(50A, 25 kA, 4P)
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Barbed Wire
LT Cable (3.5 Core) 35 mm²
Red Oxide
Aluminium Paint
Distribution Transformer 25 kva , 11/.440v
Distribution Transformer (Ordinary), 11/0.4 kV, 25 KVA
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incommer line
MS Angle Iron (50X50x6 mm), Length: 2800 x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit 11KV
Lightening Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete (HT)
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
LT Distribution Panel Box with MCCB(50A, 25 kA, 4P),O/G Kit Kit 63A 4Nos
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Barbed Wire
LT Cable (3.5 Core) 50 mm²
Red Oxide
Aluminium Paint
LT Switched Capacitors 4- KVAr for 25 KVA (rate per KVAr)
Distribution Transformer 63 kva , 11/.440v
Distribution Transformer (Ordinary), 11/0.4 kV, 63 KVA
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit 11KV
Lightening Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete (HT)
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) and SFU(63A, 4No, rewirable)
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Barbed Wire
LT Cable (3.5 Core) 120mm²
Red oxide
Aluminium Paint
LT Switched Capacitors 8- KVAr for 63KVA (rate per KVAr)
Distribution Transformer 100 KVA
Distribution Transformer (Ordinary), 11/0.4 kV, 100 KVA
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit 11KV
Lightening Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
LT Distribution Panel Box with MCCB(160A, 25 kA, 4P) and SFU(100A, 4No, rewirable)
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Barbed Wire
LT Cable (3.5 Core) 185 mm²
Red Oxide
Aluminium Paint
LT Switched Capacitors 12- KVAr for 100 KVA (rate per KVAr)
Conversion to LT Line to AB Cable
Conversion of bare conductor with LT AB Cable on poles [Size: : 3x70mm²) + 50 sqmm (Insulated)+16sqmm {Inclusive 3% sagging & wastage)
LT AB Cable on poles [Size: : 3x70mm²) + 50 sqmm (Insulated)+16sqmm {Inclusive 3% sagging & wastage)
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Stay Set Complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Full Clamp for stay
Anchoring Assembly for LT
Suspension Assembly for LT
Facade Hooks for LT
Distribution box 3 phase 5 connectors as per TS
Piercing Connector as per TS
Cable for SMDB 3.5Core X 35sqmm
T-Jointing kit
LT Earthing set complete (preferbly coil earthing)
Red Oxide
Aluminium paint
Feeder Bifurcation Works
Feeder Bifurcation Works-New HT Lines
11kv New Line on STP with rabbit Conductor -50 Sq. mm
ACSR 6/1/3.35 (50mm²) {Includes 3 conductor lengths for 3Φ and Additional 1% (Sag, Jumpering and wastage}
STP 11 Mtr Long
Muffs with concerete filling
Cross Arm: [Channel Iron (125x65x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure
Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron: 125x65x6, Length: 2340 mm x 2 No.] ∆ Formation
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (2 No./Run Thro & 5 No. / Dead End)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete (REC Constr. Stand. J-1)
Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
Eye Hook for earth wire
Earth Wire Clamp
MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
Half clamps: [On Double Pole Dead End structure: 6 No, Run Thro' structure: 1 No]
Full clamps: [On Double Pole Dead End structure: 4 No, Run Thro' structure: 3 No]
Danger Plate (250X200X1.6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
11kv New Line on Steel Tubular Pole with Dog Conductor -100 Sq. mm
ACSR 6/1/4.72 {Includes 3 conductor lengths for 3Φ and Inclusive 3% (Sag, Jumpering and wastage}
11M Steel Tublar Pole (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures)
Muffs with concerete filling
Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ∆ Formation
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete (REC Constr. Stand. J-1)
Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
Eye Hook for earth wire
Earth Wire Clamp
MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro' structure: 2 No ]
Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro' structure: 2 No]
Danger Plate
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
11kv New Line on Steel Tubular Pole with Rabbit Conductor -50Sq. mm
ACSR 6/1/3.35 (50mm²) {Includes 3 conductor lengths for 3Φ and Inclusive 3% (Sag, Jumpering and wastage}
11M Steel Tublar Pole (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures)
Muffs with concerete filling
Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ∆ Formation
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete (REC Constr. Stand. J-1)
Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
Eye Hook for earth wire
Earth Wire Clamp
MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro' structure: 2 No ]
Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro' structure: 2 No]
Danger Plate
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
Feeder Bifurcation Works-DT
Supply ,Installation and commissioning of New DT as per scope of work
Distribution Transformer 25 kva , 11/.440v
Distribution Transformer (Ordinary), 11/0.4 kV, 25 KVA
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incommer line
MS Angle Iron (50X50x6 mm), Length: 2800 x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit 11KV
Lightening Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete (HT)
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
LT Distribution Panel Box with MCCB(50A, 25 kA, 4P),O/G Kit Kit 63A 4Nos
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Barbed Wire
LT Cable (3.5 Core) 50 mm²
Red Oxide
Aluminium Paint
LT Switched Capacitors 4 KVAr for 25 KVA (rate per KVAr)
Distribution Transformer 63 kva , 11/.440v
Distribution Transformer (Ordinary), 11/0.4 kV, 63 KVA
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit 11KV
Lightening Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete (HT)
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) and SFU(63A, 4No, rewirable)
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Barbed Wire
LT Cable (3.5 Core) 120mm²
Red oxide
Aluminium Paint
LT Switched Capacitors 8- KVAr for 63KVA (rate per KVAr)
Distribution Transformer 100 KVA
Distribution Transformer (Ordinary), 11/0.4 kV, 100 KVA
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit 11KV
Lightening Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
LT Distribution Panel Box with MCCB(160A, 25 kA, 4P) and SFU(100A, 4No, rewirable)
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Barbed Wire
LT Cable (3.5 Core) 185 mm²
Red Oxide
Aluminium Paint
LT Switched Capacitors 12- KVAr for 100 KVA (rate per KVAr)
Distribution Transformer 250 KVA
Distribution Transformer (Ordinary), 11/0.4 kV, 250 KVA
Steel Tubular Poles (09 m, Working Load > 300 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit 11KV
Lightening Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
LT Distribution Panel Box with MCCB(400A, 50kA, 4P) and SFU(150A, 4No MCCB)
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Barbed Wire
LT Cable (3.5 Core) 300 mm²
Red Oxide
Aluminium Paint
LT Switched Capacitors 36- KVAr for 250 KVA (rate per KVAr)
Transformer Bed( Civil Work (As Per HPSR))
Chain Link fencing , Angle Iron ,Gate etc for transformer fencing
Feeder Bifurcation-New LT Lines
LT AB Cable on poles [Size: (3x185mm²) +150 Sqmm (Insulated)+16 sqmm {Inclusive 3% sagging & wastage)
LT AB Cable on poles [Size: (3x185mm²) +150 Sqmm (Insulated)+16 sqmm {Inclusive 3% sagging & wastage)
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Stay Set Complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Full Clamp for stay
Anchoring Assembly for LT
Suspension Assembly for LT
Facade Hooks for LT
Distribution box 3 phase 5 connectors as per TS
Piercing Connector as per TS
Cable for SMDB 3.5Core X 35sqmm
LT Earthing set complete (preferbly coil earthing)
Red Oxide
Aluminium paint
New LT Line -single phase two wire on rabbit conductor -50 Sq. mm
ACSR 6/1/3.35 (50mm²) inclusive of sag and wastage
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
Shackle Insulator (16 kN)
D-Iron (U- Clamps)
Earth Knob
LT Stay Set Complete
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
Full Clamps [ 2 No for A.I + 1 No for Stay Set]
Earthing Set complete
Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
Spool Tie
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Paint
Red Oxide
New LT Line -Three phase four wire on rabbit conductor -50 Sq. mm
ACSR 6/1/3.35 (50mm²) inclusive of sag and wastage
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
Shackle Insulator (16 kN)
D-Iron (U- Clamps)
Earth Knob
LT Stay Set
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
Full Clamps [ 2 No for A.I + 1 No for Stay Set]
Earthing Set complete
Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
Spool Tie
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Paint
Red Oxide
Spiral PVC Spacer
New HT Line works as per Scope of Works
Feeder Segeration-
Feeder Segeration-New HT Lines
11kv New Line on STP with rabbit Conductor -50 Sq. mm
ACSR 6/1/3.35 (50mm²) {Includes 3 conductor lengths for 3Φ and Additional 1% (Sag, Jumpering and wastage}
STP 11 Mtr Long
Muffs with concerete filling
Cross Arm: [Channel Iron (125x65x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure
Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron: 125x65x6, Length: 2340 mm x 2 No.] ∆ Formation
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (2 No./Run Thro & 5 No. / Dead End)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete (REC Constr. Stand. J-1)
Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
Eye Hook for earth wire
Earth Wire Clamp
MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
Half clamps: [On Double Pole Dead End structure: 6 No, Run Thro' structure: 1 No]
Full clamps: [On Double Pole Dead End structure: 4 No, Run Thro' structure: 3 No]
Danger Plate (250X200X1.6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
11kv New Line on STP with Dog Conductor -100 Sq. mm
ACSR 6/1/4.72 (100mm²) {Includes 3 conductor lengths for 3Φ and Additional 1% (Sag, Jumpering and wastage}
Muffs with concerete filling
Cross Arm: [Channel Iron (125x65x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure
Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron: 125x65x6, Length: 2340 mm x 2 No.] ∆ Formation
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (2 No./Run Thro & 5 No. / Dead End)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete (REC Constr. Stand. J-1)
Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
Eye Hook for earth wire
Earth Wire Clamp
MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
Half clamps: [On Double Pole Dead End structure: 6 No, Run Thro' structure: 1 No]
Full clamps: [On Double Pole Dead End structure: 4 No, Run Thro' structure: 3 No]
Danger Plate (250X200X1.6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
11kv New Line on Steel Tubular Pole with Dog Conductor -100 Sq. mm
ACSR 6/1/4.72 {Includes 3 conductor lengths for 3Φ and Inclusive 3% (Sag, Jumpering and wastage}
11M Steel Tublar Pole (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures)
Muffs with concerete filling
Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ∆ Formation
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete (REC Constr. Stand. J-1)
Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
Eye Hook for earth wire
Earth Wire Clamp
MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro' structure: 2 No ]
Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro' structure: 2 No]
Danger Plate
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
11kv HT XLPE Cable underground cableing work {Inclusive 1% sagging & wastage)(size-3x120sqmm
11 kV XLPE armoured Cable [Size: (3x120 mm²) {Inclusive 1% wastage)]
11 kV Cable Straight Through Jointing Kit [Size: 3x120 mm²]
11 kV Cable Outdoor Termination Kit [Size: 3x120 mm²]
11 kV Cable Heat Shrink Outdoor Termination Kit [Size: 3x300 mm²]
RCC Hume Pipe Dia-150 mm [Length- 2 M]
Collar RCC Hume Pipe 150 mm
RCC cable cover (2 feet long)
Sand Bag (50 Kg)
Route and Joint indicating stone
Inspection Chamber
GI Pipe earthing 40 mm x 2.5/3 m 'B' class
Pipe HDPE Size 150 mm
Lug AL Crimping 70 SQMM XLPE Single HOLE
Flat GI Size 25x6 mm
Cleat HDPE for Cable Support
G.I. Pipe 100 mm DIA 'B' CLASS
Flat GI Size 50x6 mm
Channel MS Size 75x40x6 mm
Feeder Segeration Works-DT
Supply ,Installation and commissioning of New DT as per scope of work
Distribution Transformer 100 KVA
Distribution Transformer (Ordinary), 11/0.4 kV, 100 KVA
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit 11KV
Lightening Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
LT Distribution Panel Box with MCCB(160A, 25 kA, 4P) and SFU(100A, 4No, rewirable)
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Barbed Wire
LT Cable (3.5 Core) 185 mm²
Red Oxide
Aluminium Paint
LT Switched Capacitors 12- KVAr for 100 KVA (rate per KVAr)
Feeder Segeration-New LT Lines
New LT Line -single phase two wire on rabbit conductor -50 Sq. mm
ACSR 6/1/3.35 (50mm²) inclusive of sag and wastage
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
Shackle Insulator (16 kN)
D-Iron (U- Clamps)
Earth Knob
LT Stay Set Complete
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
Full Clamps [ 2 No for A.I + 1 No for Stay Set]
Earthing Set complete
Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
Spool Tie
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Paint
Red Oxide
New LT Line -Three phase four wire on rabbit conductor -50 Sq. mm
ACSR 6/1/3.35 (50mm²) inclusive of sag and wastage
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
Shackle Insulator (16 kN)
D-Iron (U- Clamps)
Earth Knob
LT Stay Set
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
Full Clamps [ 2 No for A.I + 1 No for Stay Set]
Earthing Set complete
Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
Spool Tie
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Paint
Red Oxide
Spiral PVC Spacer
NEW HT Lines
11kv New Line on Steel Tubular Pole with Dog Conductor -100 Sq. mm
ACSR 6/1/4.72 {Includes 3 conductor lengths for 3Φ and Inclusive 3% (Sag, Jumpering and wastage}
11M Steel Tublar Pole (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures)
Muffs with concerete filling
Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ∆ Formation
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete (REC Constr. Stand. J-1)
Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
Eye Hook for earth wire
Earth Wire Clamp
MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro' structure: 2 No ]
Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro' structure: 2 No]
Danger Plate
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
11kv New Line on Steel Tubular Pole with Rabbit Conductor -50Sq. mm
ACSR 6/1/3.35 (50mm²) {Includes 3 conductor lengths for 3Φ and Inclusive 3% (Sag, Jumpering and wastage}
11M Steel Tublar Pole (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures)
Muffs with concerete filling
Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ∆ Formation
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete (REC Constr. Stand. J-1)
Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
Eye Hook for earth wire
Earth Wire Clamp
MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro' structure: 2 No ]
Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro' structure: 2 No]
Danger Plate
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
NEW LT Lines (on New Dts)
New LT Line -Three phase four wire on rabbit conductor -50 Sq. mm
ACSR 6/1/3.35 (50mm²) inclusive of sag and wastage
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
Shackle Insulator (16 kN)
D-Iron (U- Clamps)
Earth Knob
LT Stay Set
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
Full Clamps [ 2 No for A.I + 1 No for Stay Set]
Earthing Set complete
Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
Spool Tie
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Paint
Red Oxide
Spiral PVC Spacer
New DT
Supply ,Installation and commissioning of New DT as per scope of work
Distribution Transformer 25 kva , 11/.440v
Distribution Transformer (Ordinary), 11/0.4 kV, 25 KVA
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incommer line
MS Angle Iron (50X50x6 mm), Length: 2800 x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit 11KV
Lightening Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete (HT)
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
LT Distribution Panel Box with MCCB(50A, 25 kA, 4P),O/G Kit Kit 63A 4Nos
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Barbed Wire
LT Cable (3.5 Core) 50 mm²
Red Oxide
Aluminium Paint
LT Switched Capacitors 4- KVAr for 25 KVA (rate per KVAr)
Distribution Transformer 63 kva , 11/.440v
Distribution Transformer (Ordinary), 11/0.4 kV, 63 KVA
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit 11KV
Lightening Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete (HT)
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) and SFU(63A, 4No, rewirable)
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Barbed Wire
LT Cable (3.5 Core) 120mm²
Red oxide
Aluminium Paint
LT Switched Capacitors 8- KVAr for 63KVA (rate per KVAr)
Distribution Transformer 100 KVA
Distribution Transformer (Ordinary), 11/0.4 kV, 100 KVA
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit 11KV
Lightening Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
LT Distribution Panel Box with MCCB(160A, 25 kA, 4P) and SFU(100A, 4No, rewirable)
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Barbed Wire
LT Cable (3.5 Core) 185 mm²
Red Oxide
Aluminium Paint
LT Switched Capacitors 12- KVAr for 100 KVA (rate per KVAr)
Distribution Transformer 250 KVA
Distribution Transformer (Ordinary), 11/0.4 kV, 250 KVA
Steel Tubular Poles (09 m, Working Load > 300 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line
MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA's
X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed
X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer]
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing
MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos
MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos
GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
D.O Fuse Unit 11KV
Lightening Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete
Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set)
Substation Pipe Earthing Complete Set(REC Constr. Stand. J-1) Inclusive MS Flat 50x6
LT Distribution Panel Box with MCCB(400A, 50kA, 4P) and SFU(150A, 4No MCCB)
Half Clamp (M.S. Flat 50X6 mm)
Full Clamps (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Barbed Wire
LT Cable (3.5 Core) 300 mm²
Transformer Bed( Civil Work (As Per HPSR))
Chain Link fencing , Angle Iron ,Gate etc for transformer fencing
Red Oxide
Aluminium Paint
LT Switched Capacitors 36- KVAr for 250 KVA (rate per KVAr)
Augmentation of DT as per given Scope of work
Augmentation of DT 25 KVA to 63 KVA
Distribution Transformer (Ordinary), 11/0.4 kV, 63 KVA
LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) and SFU(32A, 4No, rewirable)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
LT Cable (3.5 Core) 120mm²
Red Oxide
Aluminium Paint
LT Switched Capacitors8- KVAr for 63 KVA (rate per KVAr)
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
Augmentation of DT 63 KVA to 100KVA
Distribution Transformer (Ordinary), 11/0.4 kV, 100 KVA
LT Distribution Panel Box with MCCB(160A, 25 kA, 4P) and SFU(16A, 4No, rewirable)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
LT Cable (3.5 Core) 185 mm²
Red oxide
Aluminium Paint
LT Switched Capacitors 12- KVAr for 100KVA (rate per KVAr)
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
Augmentation of DT 100 KVA to 250KVA
Distribution Transformer (Ordinary), 11/0.4 kV, 250 KVA
LT Distribution Panel Box with ACB(400A, 50 kA, 4P,1 No) and SFU(150A, 4No MCCB)
Half Clamp (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
LT Cable (3.5 Core) 300 mm²
LT Switched Capacitors 36- KVAr for 250KVA (rate per KVAr)
Civil Work Bed for 250 KVA DT (As PER HPSR)
Chain Link fencing , Angle Iron ,Gate etc for transformer fencing
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
Augmentation of DT 250 KVA to 400KVA
Distribution Transformer (Ordinary), 11/0.4 kV, 400 KVA
LT Distribution Panel Box with ACB(630AI/C, 50 kA, 4P, & o/G 4 Nos MCCB 200A
Half Clamp (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
LT Cable (3.5 Core) 400 mm² X 2 incommer
LT Cable (3.5 Core) 70 mm² X 4 Outgoing
LT Switched Capacitors 60 KVAr for 400KVA (rate per KVAr)
Civil Work Bed for 400 KVA DT (As PER HPSR)
Chain Link fencing , Angle Iron ,Gate etc for transformer fencing
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
Augmentation of DT 400KVA to 630KVA
630 KVA,11/0.4KV DISTRIBUTION TRANSFORMER,
Transformer Bed( Civil Work (As Per HPSR))
LT Distribution Panel Box with ACB(1000A, 50 kA, 4P and SFU 4Nos MCCB 250A
M.S. NUTS &BOLTS OFF SIZES
Aluminium Thimble
Aluminium Thimble
LT Cable (3.5 Core) 400 mm² x 2 incoming
LT Cable (3.5 Core) 95 mm² x 4outgoing feeder
Chain Link fencing , Angle Iron ,Gate etc for transformer fencing
Red Oxide
Aluminium paint
LT Switched Capacitors 60 KVAr for 630KVA (rate per KVAr)
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
Augmentation of LT Line
Augmentation of LT Lines -1 phase to 3-phase with 50 Sq. mm Rabbit conductor
ACSR Rabbit Conductor 50 Sq. mm inclusive of sag and wastage
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
Shackle Insulator (16 kN)
D-Iron (U- Clamps)
Earth Knob
LT Stay Set
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
Full Clamps [ 2 No for A.I + 1 No for Stay Set]
Earthing Set complete
Spool Tie
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Paint
Red Oxide
Spiral PVC Spacer
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
Augmentation of LT Lines -2 phase to three phase with 50 Sq. mm Rabbit conductor
ACSR Rabbit Conductor 50 Sq. mm inclusive of sag and wastage
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
Shackle Insulator (16 kN)
D-Iron (U- Clamps)
Earth Knob
LT Stay Set
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
Full Clamps [ 2 No for A.I + 1 No for Stay Set]
Earthing Set complete
Spool Tie
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Paint
Red Oxide
Spiral PVC Spacer
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
Reconductoring of LT Lines -3 phase4Wire with 50 Sq. mm Rabbit conductor
ACSR 6/1/3.35 (50mm²) inclusive of sag and wastage
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
Shackle Insulator (16 kN)
D-Iron (U- Clamps)
Earth Knob
LT Stay Set
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
Full Clamps [ 2 No for A.I + 1 No for Stay Set]
Earthing Set complete
Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
Spool Tie
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Paint
Red Oxide
Spiral PVC Spacer
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
Reconductoring of LT Lines -3 phase4Wire with 100 Sq. mm Dog conductor
ACSR 6/1/4.72(100mm²) inclusive of sag and wastage
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]
Shackle Insulator (16 kN)
D-Iron (U- Clamps)
Earth Knob
LT Stay Set
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
Full Clamps [ 2 No for A.I + 1 No for Stay Set]
Earthing Set complete
Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m
Spool Tie
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Paint
Red Oxide
Spiral PVC Spacer
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
Augmentation of HT Lines
Augmentation of existing Line with 11Kv Dog Conductor of 100Sqm
ACSR 6/1/4.72 (100mm²) {Includes 3 conductor lengths for 3Φ and Additional 1% (Sag, Jumpering and wastage}
Steel Tubular Poles (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures)
Muffs with concerete filling
Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 2 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 2 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure
Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ∆ Formation
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete (REC Constr. Stand. J-1)
Eye Hook for earth wire
Earth Wire Clamp
Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro' structure: 2 No ]
Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro' structure: 2 No]
Danger Plate (250X200X1.6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
Augmentation of existing Line with 11Kv Rabbit Conductor of 50Sqm
ACSR 6/1/3.35MM (50mm²) {Includes 3 conductor lengths for 3Φ and Additional 1% (Sag, Jumpering and wastage}
Steel Tubular Poles (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures)
Muffs with concerete filling
Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 2 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 2 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure
Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ∆ Formation
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete (REC Constr. Stand. J-1)
Eye Hook for earth wire
Earth Wire Clamp
Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro' structure: 2 No ]
Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro' structure: 2 No]
Danger Plate (250X200X1.6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
Augumentation of existing line with 33 KV AL 59 Conductor of 150 Sq. mm
ACSR 30/7/2.59 (150mm²) {Includes 3 conductor lengths for 3Φ and Additional 1% (Sag, Jumpering and wastage}
Steel Tubular Poles (13 m, Working Load > 227 kg) (with Ruling Span 90 m, 10 No. Run thro' and 3 No. Dead End Structures)
Muffs (2000mm) with concerete filling
X-Arms: [MS Channel Iron C type (125X66X6) mm, Length: 3250 mm i/c tolerance 100 mm on either side] x 10 No. Structures
Disc insulator String (Suspension) sets: 3 No. Discs in each string: ^^(Porcelain, CT, 12 kV, 90 kN) including dead end clamps etc)x (Single circuit : 3No conductors) x 1 No sides) /Run Throu' structures.
Belt Set - MS Angle Iron: 65x65x6, Length:(1800 mm) x 2 No.
X-Bracing Set - MS Angle Iron: 50X50x6, Length [2700 mm) x 2 No.]
Belt Set - MS Angle Iron: 65x65x6, Length:(1800 mm) x 2 No.
X-Bracing Set - MS Angle Iron: 50X50x6, Length [2700 mm) x 2 No.]
X-Arm (Horizontal) - MS Channel Iron C type: (125x66x6 mm), Length: 3250 mm i/c tolerance 100 mm on either side x 2 No.]
Discs insulator String sets on Dead End structures (comprising 3 No. Discs in each string: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps, Bend Stapples & straight Stapples etc.) x (3 No. conductors) x (2 No. sides)
33 kV Pin Insulators (Porcelain, 36 kV, 10 kN): 3 No per double pole structure
Dead End Clamp L/S
PG Clamp L/S
Stay set complete in all respect (2 No./Run Thro & 8 No. / Dead End)
Stay Wire (7/4.00 mm) (9.0 kg Per Stay Set)
HT Earthing set complete
Eye Hook for earth wire
Earth Reel
Half clamps: [On Double Pole Dead End structure: 6 No, Double Pole Run Thro' structure: 8 No]
Full clamps: [On Double Pole Dead End structure: 4 No, Double Pole Run Thro' structure: 4 No]
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 20 mm Φ or more (with flat and spring washers)]
Barbed wire
Danger Plate (203X200X1.6mm)
Red Oxide
Aluminium Paint
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
New 33 KV Line Work
New 33 KV Single Circuit Line with Dog Conductor on STP
ACSR 6/1/4.72 (100mm²) {Includes 3 conductor lengths for 3Φ and Additional 1% (Sag, Jumpering and wastage}
New 33 KV Single Circuit Line with Dog Conductor on 11 mtr STP
Muffs with concerete filling
X-Arms: [MS Channel Iron (100x50x6 mm, Length: 3250 mm i/c tolerance 100 mm on either side] x 10 No. Structures
Disc insulator String (Suspension) sets: 3 No. Discs in each string: ^^(Porcelain, CT, 12 kV, 90 kN) including dead end clamps etc)x (Single circuit : 3No conductors) x 1 No sides) /Run Throu' structures.
Belt Set - MS Angle Iron: 65x65x6, Length:(1800 mm) x 2 No.
X-Bracing Set - MS Angle Iron: 50X50x6, Length [2700 mm) x 2 No.]
Belt Set - MS Angle Iron: 65x65x6, Length:(1800 mm) x 2 No.
X-Bracing Set - MS Angle Iron: 50X50x6, Length [2700 mm) x 2 No.]
X-Arm (Horizontal) - MS Channel Iron: (100x50x6 mm), Length: 3250 mm i/c tolerance 100 mm on either side x 2 No.]
Disc insulator String (Strain) sets: 3 No. Discs in each string: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (Single Circuit: 3 No. conductors) x (2 No. sides) /Dead Structures
33 kV Pin Insulators (Porcelain, 36 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (2 No./Run Thro & 4 No. / Dead End)
Stay Wire (7/4.00 mm) (10 kg Per Stay Set)
HT Earthing set complete
Earth wire (GI, 6 SWG) {Includes Single wire length and Additional 1% (Sag and wastage)}@ 150 kg/km
Eye Hook for earth wire
Earth Reel
MS Channel Iron: 75x40x6, Length :3300 mm
Half clamps: [On Double Pole Dead End structure: 6 No, Double Pole Run Thro' structure: 8 No]
Full clamps: [On Double Pole Dead End structure: 4 No, Double Pole Run Thro' structure: 4 No]
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 20 mm Φ or more (with flat and spring washers)]
Barbed wire
Danger Plate (203X200X1.6mm)
Red Oxide
Aluminium Paint
New 11kv Line works as per Scope of Work
11KV line -11kv line on Steel Tublar pole with Dog Conductor -100Sq. mm
ACSR 6/1/4.72 {Includes 3 conductor lengths for 3Φ and Inclusive 3% (Sag, Jumpering and wastage}
11M Steel Tublar Pole (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro' and 3 No. Double Pole Dead End Structures)
Muffs with concerete filling
Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/c tolerance of 100 mm either side) x 8 structure
Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures
Pole Top Bracket [MSCI:100x50x6 mm- 100 mm]
11 kV Pin Insulators with GI Pin(Porcelain, 12 kV, 10 KN): 3 No per pole structure
Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No.
X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No.
X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ∆ Formation
Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides)
11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures)
Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set)
HT Earthing set complete (REC Constr. Stand. J-1)
Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m
Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m}
Eye Hook for earth wire
Earth Wire Clamp
MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing
Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro' structure: 2 No ]
Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro' structure: 2 No]
Danger Plate
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Barbed Wire
Red Oxide
Aluminium Paint
GO Switch Handle Supporting: [Channel Iron (75x40x5 mm), Length : 460 mm
GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type
New 33/11 KV Sub Station
2X1.6 MVA (PSS Dalhousi circle-Banikhet, Salwan)Total=2 Nos.
Power Transformer (1.6 MVA, 33/11 kV, ONAN, OLTC, Outdoor)
Sub Station Transformer (100 kVA, 33/0.4 kV)
33 kV Switchgear & Allied Equipment
a) 33 kV Control and Relay (CR) Panel (with Numeric Differential Relay, IEC 61850)
b) 33 kV Control and Relay (CR) Panel (33 kV Incomer Bus) [Numeric Relay, IEC 61850]
c) 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type)
d) 33 kV Isolator (1600 A, 25kA, with Earth Switch) (Moterised)
e) 33 kV Isolator (1600 A, 25kA, without Earth Switch) (Moterised)
f) 33 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO, Porcelain)
g) 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ)
h) 33 kV Potential Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ)
i) 33 kV Drop Out Fuse Unit (33 kV, Expulsion)
11 kV Switchgear and Allied equipment: 02 No. incomer Bus
a) 11 kV incomer Bus: Control and Relay (CR) Panel with VCB (12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850]
b) 11 kV Incomer Bus: Potential Transformer (11 kV/110V, 3Φ, Indoor)
c) 11 kV LA/ Surge Arrester (9 KV, 10 kA ,Station Class, ZnO, Porcelain, Outdoor)
d) 11 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured) {Transformer to 11 kV Bus} {50m}+Spare
e) 11 kV Cable Termination Kit (400 mm², Outdoor)
f) 11 kV Cable Termination Kit (400 mm², Indoor)
11 kV Switchgear and Allied equipment: Single (8 No.) Outgoing Feeder
a) 11 kV Outgoing Feeder: Control and Relay (CR) Panel with indoor VCB (12 kV, 1250 A, 25KA) including CT
c) 11 kV LA/ Surge Arrester (9 kV, 10 kA Station Class, ZnO, Porcelain, Outdoor)
d) 11 kV Cable (11 kV, 185 mm², XLPE, Three Core, Armoured) {Busbar VCB to Isolator} {50m+ Spare- 50m}
e) 11 kV Cable Termination Kit (185 mm², Outdoor)
f) 11 kV Cable Termination Kit (185 mm², Indoor)
LT Cable (1.1 kV, 3.5 Core, 70 mm2) {from Station Tfr}
Capacitor Bank (3-Ф, 50 Hz, 1200 KVAr) [ IS:2834 ]
Automatic Capacitor Switch (12 kV, 1250 A, 25 kA) [REC Spec. 20/1981]
Battery Bank with Dual FCBC Battery Charger (15 No x 2V Cell, Lead Acid, 30 V, 200 AH)
Distribution Panel (30V, DC)
Distribution Panel (415 V, AC)Distribution Panel (415 V, AC) 200 Amp as incomer MCCB & 6 Nos 63 Amp MCCB as outgoing with voltmeter and Ammeter of 0.5 accuracy class alongwith phase indicating lamps of accuracy class 0.5
Super Strcture and Bus Bar Arrangement
(i) R.S. Joists, size 12800x250x125 mm 16 supports
(ii) R.S.Joists, size 4200x250x125 mm supports for Power Transformer's LA, Station Transformer LA, I/C, Power Transformer's CTs
(iii) M.S. channel iron 125x65 mm, X-arm @13.1 kg/m at 5% wastage for Bus-bar,Isolators,CT, LA's transformer etc.
(iv) M.S. angle iron 65x65 X-arm @ 5.8 kg/m & 5% wastage for body supports belt of Station transformer including 5% wastage
(v) Nuts & Bolts with Washers off sizes
BUS-BAR
(i) 3 Disc insulators Tension String complete with fitting
(ii) ACSR conductor 200 mm² at 10 % wastage
For jumpers at 2 m average 30 nos I.e.
(iii) Tee connections
(iv) PG clamps
Gantry FOR 33 kV
(a) Steel tubular pole 11 m long
(b) RCC muffs (2000mm) & concreting thereof for 1 No. out going Feeder
(a)5.5 m long M.S. channel iron 100X50X5 mm 9.56 kg/m Cross arms for Sub-Station With 1 No. out going Feeder (33kV)
(b) M.S. angle iron 50X50X6 mm 4.5 kg/m Cross arms for Sub-Station With 1 No. out going Feeder [ 4.2x3+5.33x2] (11kV)
(d) M.S. Half clamps
(e) Full Clamp
(f) Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
ACSR 100 mm² conductor for Jumpers [approx. 4 mtr/ phase]
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors)
Clamps for 1 Nos. out going Feeder
33 kV Isolator Moterised with ES
Gantry for 8 no. outgoing feeder
(a) Steel tubular pole 11 m long for 8 No. out going Feeder
(b) RCC muffs (2000mm) & concreting thereof for 1 No. out going Feeder
(a)4.2 m long M.S. channel iron 100X50X5 mm 9.56 kg/m Cross arms for Sub-Station With 1 No. out going Feeder (11Kv)
(b) M.S. angle iron 50X50X6 mm 4.5 kg/m Cross arms for Sub-Station With 1 No. out going Feeder [ 4.2x3+5.33x2] (11kV)
(d) M.S. Half clamps
(e) Full Clamp
(f) Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
ACSR 100 mm² conductor for Jumpers [approx. 4 mtr/ phase]
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors)
Clamps for out going Feeder
11 kV Isolator Moterised
Earthing of 33/11KV Substation
Earthing of 33 kV yard & equipment & 22 kV or 11kV panels M.S. flat 50x6 mm,wt. 2.4 kg/m At 5% wastage:- (a) Transformer Earthing at 3 points for 2 Nos Power Transformers (body & neutral) at 10 Mtr each 2X(3x10)x1.05=63 Mtr (b) For 4 No. LA's at 4.2 Mtr each 2X4.2x2x1.05=17.64 Mtr (c) For 22 nos. 33 kV super structure at 11.50 Mtr each 22x11.50x1.05 =265.65 Mtr i.e. 266 Mtr (d) For 32 Nos. VCB & CT body earthing at 10 m Each (32x10)x1.05 = 336 Mtr Total =682 mtr. i.e. 682X 2.4= 1638 ie 1.638 MT
GI Wire 6 No. SWG for screening etc.
Eye Block for screening
Tumbuckle for screening
GI Pipe 50 mm dia with holes of 16mm dia at 150 mm for centre to centre for 2 m distance from bottom For Transformer and for 11KV panels and fencing and Fixing of GI pipe 50mm with earth pit 10 nos per PSS Providing Coal=125 kg,Charcoal 23 kg ,Salt 122 kg,Sand 84 kg in each Earth Pit(Earth Pit Material)
MS plates 150x150x6mm for two connection
50x6 mm MS Flat connection with the mat to mat
Nut and bolts galvanized various sizes
Chequered plate cover 500x500x6mm i.e.11.8Kg
Providing MS Rod 40 mm dia 6 mtr long for Earth Matt Rods )(weight 9.9 kg per mtr) 16x6x9.9=950kg and Digging of 6 meter pits for earth rods 40 mm dia
Yard Lighting:-a) 9 m, Steel Tubular poles for yard lighting
b)18 W LED Lamp complete with fittings
c)Post Erection for gate
d)Clamps for GI pipe bracket
e)Underground cable 16 mm² for yard lighting
f)PVC cable size 6 mm² for connecting LED lamp supply
g)Junction box i/c MCCB and other allied
Lighting Emergency (3 No LED Bulbs with holders / wire)
control cable: 2x2.5 mm²
control cable: 4x2.5 mm²
control cable:12x2.5 mm²
3.5 core 95 mm² aluminium cable suitable for 415 V, AC
Fire Fighting Equipments as per TS
Safety Equipments & T & P as per TS
CIVIL WORKS
Control Room one Storey Building Sizes(14.7x14.8)sqm as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33202/2018
water supply and sanitary installation for Control Room Building.
Electrical Installation for control room building (for 60 points)
Septic Tank (1 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33254/2020
Rain Water Harvesting Tank (1 No per PSS) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33249/2020
Power Transformers Foundation suitable for upto 3.15 MVA (2 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33239/2020
Substation Transformer Foundation (1 No)
VCB Foundation (5 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33241/2020
Foundation of R.S. Joist supports (16 Nos) as per drawing of HPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33243/2020
Foundation of CT, PT & LA (14Nos) as per drawing of HPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33242/2020
Outdoor Cable Trench ( 80 mtr Per PSS) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33245/2020
Indoor Cable Trench ( 30 mtr trench per PSS) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33247-48/2020
Cost Of Boundary Wall (200Meter/Pss) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33251-52/2020
Cost for retaining wall as per drawing of
Main Gate & Sub-Station Yard Gate(1 Nos) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33253/2020
Spreading of gravells/ Shingles in yard (30CUM ) as per drawing of HPSEBL/SEDES/SSD-478/2021-22-7972-79/2021
Formation of drainage system around the substation around 60x40mtr yard (200 Meter) as per drawing of
Firewall Protection as per drawing HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33244/2020
Chain Link Fencing with wooven mesh of GI wire 15MX30M
Cost of Soil Testing & Contour plans & design
Site development and providing retaining walls for proposed 33/11KV Sub Station 2x 1.6 MVA (Manned) at Banikhet in ESD Dalhousie (U)
Eathwork in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.Ordinary rock
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing 1:5:10 (1 cement : 5 coarse sand) : 10 graded stone aggregate 40 mm nominalsize)
Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets,kerbs and steps et
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes
Site development and providing retaining walls for proposed 33/11 kv 2x 1.6 MVA (Manned) S/Stn at Salwan in ESD Bhalaei (U) Electrical Division Dalhousie.
Eathwork in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.Ordinary rock
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing 1:5:10 (1 cement : 5 coarse sand) : 10 graded stone aggregate 40 mm nominalsize)
Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets,kerbs and steps et
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes
Site development and providing retaining walls for proposed 33/11KV Sub Station 2x 1.6 MVA (Manned) at Salwan in ESD Bhalaei (U) Electrical Division Dalhousie
Eathwork in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.Ordinary rock
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing 1:5:10 (1 cement : 5 coarse sand) : 10 graded stone aggregate 40 mm nominalsize)
Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets,kerbs and steps et
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes
New 33/11 KV Sub Station
1X3.15MVA (New PSS at Latthiani in UNA Circle;Bir,Rakkar/Andreta in Kangra Circle )-3 NOS.
Power Transformer (3.15 MVA, 33/11 kV, ONAN, OLTC, Outdoor)
Sub Station Transformer (100 kVA, 33/0.4 kV)
33 kV Switchgear & Allied Equipment
a) 33 kV Control and Relay (CR) Panel (with Numeric Differential Relay, IEC 61850)
b) 33 kV Control and Relay (CR) Panel (33 kV Incomer Bus) [Numeric Relay, IEC 61850]
c) 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type)
d) 33 kV Isolator (1600 A, 25kA, with Earth Switch) (Moterised)
e) 33 kV Isolator (1600 A, 25kA, without Earth Switch) (Moterised)
f) 33 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO, Porcelain)
g) 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ)
h) 33 kV Potential Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ)
i) 33 kV Drop Out Fuse Unit (33 kV, Expulsion)
11 kV Switchgear and Allied equipment: 01 No. incomer Bus
a) 11 kV incomer Bus: Control and Relay (CR) Panel with VCB (12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850]
b) 11 kV Incomer Bus: Potential Transformer (11 kV/110V, 3Φ, Indoor)
c) 11 kV LA/ Surge Arrester (9 KV, 10 kA ,Station Class, ZnO, Porcelain, Outdoor)
d) 11 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured) {Transformer to 11 kV Bus} {50m}+Spare
e) 11 kV Cable Termination Kit (400 mm², Outdoor)
f) 11 kV Cable Termination Kit (400 mm², Indoor)
11 kV Switchgear and Allied equipment: Single (2 No.) Outgoing Feeder
a) 11 kV Outgoing Feeder: Control and Relay (CR) Panel with indoor VCB (12 kV, 1250 A, 25KA) including CT
b) 11 kV Isolator (12 kV, 1250 A, 25 kA, with Earth Switch, Outdoor)
c) 11 kV LA/ Surge Arrester (9 kV, 10 kA Station Class, ZnO, Porcelain, Outdoor)
d) 11 kV Cable (11 kV, 185 mm², XLPE, Three Core, Armoured) {Busbar VCB to Isolator} {50m+ Spare- 50m}
e) 11 kV Cable Termination Kit (185 mm², Outdoor)
f) 11 kV Cable Termination Kit (185 mm², Indoor)
LT Cable (1.1 kV, 3.5 Core, 70 mm2) {from Station Tfr}
Capacitor Bank (3-Ф, 50 Hz, 1200 KVAr) [ IS:2834 ]
Automatic Capacitor Switch (12 kV, 1250 A, 25 kA) [REC Spec. 20/1981]
Battery Bank with Dual FCBC Battery Charger (15 No x 2V Cell, Lead Acid, 30 V, 200 AH)
Distribution Panel (30V, DC)
Distribution Panel (415 V, AC)Distribution Panel (415 V, AC) 200 Amp as incomer MCCB & 6 Nos 63 Amp MCCB as outgoing with voltmeter and Ammeter of 0.5 accuracy class alongwith phase indicating lamps of accuracy class 0.5
Super Strcture and Bus Bar Arrangement
(i) R.S. Joists, size 12800x250x125 mm 8 supports
(ii) R.S.Joists, size 4200x250x125 mm supports for Power Transformer's LA, Station Transformer LA, I/C, Power Transformer's CTs
(iii) M.S. channel iron 125x65 mm, X-arm @13.1 kg/m at 5% wastage for Bus-bar,Isolators,CT, LA's transformer etc. =100
(iv) M.S. angle iron 65x65 X-arm @ 5.8 kg/m & 5% wastage for body supports belt of Station transformer including 5% wastage
(v) Nuts & Bolts with Washers off sizes
BUS-BAR
(i) 3 Disc insulators Tension String complete with fitting
(ii) ACSR conductor 200 mm² at 10 % wastage
For jumpers at 2 m average 15 nos I.e.
(iii) Tee connections
(iv) PG clamps
Gantry for 2 no. outgoing feeder
(a) Steel tubular pole 11 m long for 1 No. out going Feeder
(b) RCC muffs (2000mm) & concreting thereof for 1 No. out going Feeder
(a)4.2 m long M.S. channel iron 100X50X5 mm 9.56 kg/m Cross arms for Sub-Station With 1 No. out going Feeder (11Kv)
(b) M.S. angle iron 50X50X6 mm 4.5 kg/m Cross arms for Sub-Station With 1 No. out going Feeder [ 4.2x3+5.33x2] (11kV)
(d) M.S. Half clamps
(e) Full Clamp
(f) Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
ACSR 100 mm² conductor for Jumpers [approx. 4 mtr/ phase]
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors)
Clamps for 1 Nos. out going Feeder
11 kV Isolator
Earthing of 33/11KV Substation
Earthing of 33 kV yard & equipment & 22 kV or 11kV panels M.S. flat 50x6 mm,wt. 2.4 kg/m At 5% wastage:- (a) Transformer Earthing at 3 points for 2 Nos Power Transformers (body & neutral) at 10 Mtr each 2X(3x10)x1.05=63 Mtr (b) For 4 No. LA's at 4.2 Mtr each 2X4.2x2x1.05=17.64 Mtr (c) For 22 nos. 33 kV super structure at 11.50 Mtr each 22x11.50x1.05 =265.65 Mtr i.e. 266 Mtr (d) For 32 Nos. VCB & CT body earthing at 10 m Each (32x10)x1.05 = 336 Mtr Total =682 mtr. i.e. 682X 2.4= 1638 ie 1.638 MT
GI Wire 6 No. SWG for screening etc.
Eye Block for screening
Tumbuckle for screening
GI Pipe 50 mm dia with holes of 16mm dia at 150 mm for centre to centre for 2 m distance from bottom For Transformer and for 11KV panels and fencing and Fixing of GI pipe 50mm with earth pit 10 nos per PSS Providing Coal=125 kg,Charcoal 23 kg ,Salt 122 kg,Sand 84 kg in each Earth Pit(Earth Pit Material)
MS plates 150x150x6mm for two connection
50x6 mm MS Flat connection with the mat to mat
Nut and bolts galvanized various sizes
Chequered plate cover 500x500x6mm i.e.11.8Kg
Providing MS Rod 40 mm dia 6 mtr long for Earth Matt Rods )(weight 9.9 kg per mtr) 16x6x9.9=950kg and Digging of 6 meter pits for earth rods 40 mm dia
Yard Lighting:-a) 9 m, Steel Tubular poles for yard lighting
b)18 W LED Lamp complete with fittings
c)Post Erection for gate
d)Clamps for GI pipe bracket
e)Underground cable 16 mm² for yard lighting
f)PVC cable size 6 mm² for connecting LED lamp supply
g)Junction box i/c MCCB and other allied
Lighting Emergency (3 No LED Bulbs with holders / wire)
control cable: 2x2.5 mm²
control cable: 4x2.5 mm²
control cable:12x2.5 mm²
3.5 core 95 mm² aluminium cable suitable for 415 V, AC
Fire Fighting Equipments as per TS
Safety Equipments & T & P as per TS
CIVIL WORKS
Control Room one Storey Building Sizes(14.7x14.8)sqm as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33202/2018
water supply and sanitary installation for Control Room Building.
Electrical Installation for control room building (for 60 points)
Septic Tank (1 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33254/2020
Rain Water Harvesting Tank (1 No per PSS) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33249/2020
Power Transformers Foundation suitable for upto 3.15 MVA (2 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33239/2020
Substation Transformer Foundation (1 No)
VCB Foundation (5 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33241/2020
Foundation of R.S. Joist supports (16 Nos) as per drawing of HPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33243/2020
Foundation of CT, PT & LA (14Nos) as per drawing of HPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33242/2020
Outdoor Cable Trench ( 80 mtr Per PSS) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33245/2020
Indoor Cable Trench ( 30 mtr trench per PSS) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33247-48/2020
Cost Of Boundary Wall (200Meter/Pss) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33251-52/2020
Main Gate & Sub-Station Yard Gate(1 Nos) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33253/2020
Spreading of gravells/ Shingles in yard (30CUM ) as per drawing of HPSEBL/SEDES/SSD-478/2021-22-7972-79/2021
Formation of drainage system around the substation around 60x40mtr yard (200 Meter) as per drawing of
Firewall Protection as per drawing HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33244/2020
Chain Link Fencing with wooven mesh of GI wire 15MX30M
Cost of Soil Testing & Contour plans & design
Site development and Construction of Approach Road to 33/11 kv, 1 x 3.15 MVA sub station (Manned) at Lathani under Electrical Sub Division HPSEBL,Bangana
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : on W.B.M. @ 0.75 Kg / sqm
Providing and laying bituminous macadam using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site by tippers, laid over a previously prepared surface with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge. 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 3.50% (percentage by weight of total mix) prepared in Drum Type Hot Mix Plant of 60- 90 TPH capacity.
Providing and laying semi- dense Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in- Charge. 25 mm compacted thickness with bitumen of grade VG- 30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100- 120 TPH capacity.
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. 450 mm dia RCC pipes.
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand: 10 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Site development and providing retaining walls/Breast walls for 33/11KV, 1×3.15MVA Sub Station Bir under Electrical Division HPSEBL Baijnath
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. Ordinary rock
Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 mtr. All kinds of soil
Centering and shuttering including strutting, propping etc. and removal of form work for retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Supplying, filling, spreading & leveling gravels of size range 20 mm to 40 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge
Site Development Providing retaining wall for Const. 33/11 KV, 1X3.15 MVA Sub- Station at Andreta under Electrical Division , HPSEB Ltd. Baijnath.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas ( exceeding 30cm in depth ,1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. hard rock (requiring blasting)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30*30 *5mm in Vertical surfaces such as wall (any thickness) and the like .
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
stone filling behind the R/wall with hard stones of app quality.
P/F PVC pipe 4" dia in weap holes @1.00 M o/c in staggered
Excavation in earth work and filling in 15cm layers in foundation and plinth i/c ramming watering and consolidating upto a lead of 20 mtrs.s lift upto a 1.5 mtrs.
New 33/11 KV Sub Station
2X3.15 MVA PSS (Una Circle-Mubarikpur,Lahrli);(Kangra Circle-Dhagwar,Gamru,Daulatpur,Negul Café,Bonodu) Total -7 Nos
Power Transformer (3.15 MVA, 33/11 kV, ONAN, OLTC, Outdoor)
Sub Station Transformer (100 kVA, 33/0.4 kV)
33 kV Switchgear & Allied Equipment
a) 33 kV Control and Relay (CR) Panel (with Numeric Differential Relay, IEC 61850)
b) 33 kV Control and Relay (CR) Panel (33 kV Incomer Bus) [Numeric Relay, IEC 61850]
c) 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type)
d) 33 kV Isolator (1600 A, 25kA, with Earth Switch) (Moterised)
e) 33 kV Isolator (1600 A, 25kA, without Earth Switch) (Moterised)
f) 33 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO, Porcelain)
g) 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ)
h) 33 kV Potential Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ)
i) 33 kV Drop Out Fuse Unit (33 kV, Expulsion)
11 kV Switchgear and Allied equipment: 02 No. incomer Bus
a) 11 kV incomer Bus: Control and Relay (CR) Panel with VCB (12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850]
b) 11 kV Incomer Bus: Potential Transformer (11 kV/110V, 3Φ, Indoor)
c) 11 kV LA/ Surge Arrester (9 KV, 10 kA ,Station Class, ZnO, Porcelain, Outdoor)
d) 11 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured) {Transformer to 11 kV Bus} {50m}+Spare
e) 11 kV Cable Termination Kit (400 mm², Outdoor)
f) 11 kV Cable Termination Kit (400 mm², Indoor)
11 kV Switchgear and Allied equipment: Single (8 No.) Outgoing Feeder
a) 11 kV Outgoing Feeder: Control and Relay (CR) Panel with indoor VCB (12 kV, 1250 A, 25KA) including CT
c) 11 kV LA/ Surge Arrester (9 kV, 10 kA Station Class, ZnO, Porcelain, Outdoor)
d) 11 kV Cable (11 kV, 185 mm², XLPE, Three Core, Armoured) {Busbar VCB to Isolator} {50m+ Spare- 50m}
e) 11 kV Cable Termination Kit (185 mm², Outdoor)
f) 11 kV Cable Termination Kit (185 mm², Indoor)
LT Cable (1.1 kV, 3.5 Core, 70 mm2) {from Station Tfr}
Capacitor Bank (3-Ф, 50 Hz, 1200 KVAr) [ IS:2834 ]
Automatic Capacitor Switch (12 kV, 1250 A, 25 kA) [REC Spec. 20/1981]
Battery Bank with Dual FCBC Battery Charger (15 No x 2V Cell, Lead Acid, 30 V, 200 AH)
Distribution Panel (30V, DC)
Distribution Panel (415 V, AC)Distribution Panel (415 V, AC) 200 Amp as incomer MCCB & 6 Nos 63 Amp MCCB as outgoing with voltmeter and Ammeter of 0.5 accuracy class alongwith phase indicating lamps of accuracy class 0.5
Super Strcture and Bus Bar Arrangement
(i) R.S. Joists, size 12800x250x125 mm 16 supports
(ii) R.S.Joists, size 4200x250x125 mm supports for Power Transformer's LA, Station Transformer LA, I/C, Power Transformer's CTs
(iii) M.S. channel iron 125x65 mm, X-arm @13.1 kg/m at 5% wastage for Bus-bar,Isolators,CT, LA's transformer etc.
(iv) M.S. angle iron 65x65 X-arm @ 5.8 kg/m & 5% wastage for body supports belt of Station transformer including 5% wastage
(v) Nuts & Bolts with Washers off sizes
BUS-BAR
(i) 3 Disc insulators Tension String complete with fitting
(ii) ACSR conductor 200 mm² at 10 % wastage
For jumpers at 2 m average 30 nos I.e.
(iii) Tee connections
(iv) PG clamps
Gantry FOR 33 kV
(a) Steel tubular pole 11 m long
(b) RCC muffs (2000mm) & concreting thereof for 1 No. out going Feeder
(a)5.5 m long M.S. channel iron 100X50X5 mm 9.56 kg/m Cross arms for Sub-Station With 1 No. out going Feeder (33kV)
(b) M.S. angle iron 50X50X6 mm 4.5 kg/m Cross arms for Sub-Station With 1 No. out going Feeder [ 4.2x3+5.33x2] (11kV)
(d) M.S. Half clamps
(e) Full Clamp
(f) Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
ACSR 100 mm² conductor for Jumpers [approx. 4 mtr/ phase]
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors)
Clamps for 1 Nos. out going Feeder
33 kV Isolator Moterised with ES
Gantry for 8 no. outgoing feeder
(a) Steel tubular pole 11 m long for 8 No. out going Feeder
(b) RCC muffs (2000mm) & concreting thereof for 1 No. out going Feeder
(a)4.2 m long M.S. channel iron 100X50X5 mm 9.56 kg/m Cross arms for Sub-Station With 1 No. out going Feeder (11Kv)
(b) M.S. angle iron 50X50X6 mm 4.5 kg/m Cross arms for Sub-Station With 1 No. out going Feeder [ 4.2x3+5.33x2] (11kV)
(d) M.S. Half clamps
(e) Full Clamp
(f) Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
ACSR 100 mm² conductor for Jumpers [approx. 4 mtr/ phase]
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors)
Clamps for out going Feeder
11 kV Isolator Moterised
Earthing of 33/11KV Substation
Earthing of 33 kV yard & equipment & 22 kV or 11kV panels M.S. flat 50x6 mm,wt. 2.4 kg/m At 5% wastage:- (a) Transformer Earthing at 3 points for 2 Nos Power Transformers (body & neutral) at 10 Mtr each 2X(3x10)x1.05=63 Mtr (b) For 4 No. LA's at 4.2 Mtr each 2X4.2x2x1.05=17.64 Mtr (c) For 22 nos. 33 kV super structure at 11.50 Mtr each 22x11.50x1.05 =265.65 Mtr i.e. 266 Mtr (d) For 32 Nos. VCB & CT body earthing at 10 m Each (32x10)x1.05 = 336 Mtr Total =682 mtr. i.e. 682X 2.4= 1638 ie 1.638 MT
GI Wire 6 No. SWG for screening etc.
Eye Block for screening
Tumbuckle for screening
GI Pipe 50 mm dia with holes of 16mm dia at 150 mm for centre to centre for 2 m distance from bottom For Transformer and for 11KV panels and fencing and Fixing of GI pipe 50mm with earth pit 10 nos per PSS Providing Coal=125 kg,Charcoal 23 kg ,Salt 122 kg,Sand 84 kg in each Earth Pit(Earth Pit Material)
MS plates 150x150x6mm for two connection
50x6 mm MS Flat connection with the mat to mat
Nut and bolts galvanized various sizes
Chequered plate cover 500x500x6mm i.e.11.8Kg
Providing MS Rod 40 mm dia 6 mtr long for Earth Matt Rods )(weight 9.9 kg per mtr) 16x6x9.9=950kg and Digging of 6 meter pits for earth rods 40 mm dia
Yard Lighting:-a) 9 m, Steel Tubular poles for yard lighting
b)18 W LED Lamp complete with fittings
c)Post Erection for gate
d)Clamps for GI pipe bracket
e)Underground cable 16 mm² for yard lighting
f)PVC cable size 6 mm² for connecting LED lamp supply
g)Junction box i/c MCCB and other allied
Lighting Emergency (3 No LED Bulbs with holders / wire)
control cable: 2x2.5 mm²
control cable: 4x2.5 mm²
control cable:12x2.5 mm²
3.5 core 95 mm² aluminium cable suitable for 415 V, AC
Fire Fighting Equipments as per TS
Safety Equipments & T & P as per TS
CIVIL WORKS
Control Room one Storey Building Sizes(14.7x14.8)sqm as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33202/2018
water supply and sanitary installation for Control Room Building.
Electrical Installation for control room building (for 60 points)
Septic Tank (1 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33254/2020
Rain Water Harvesting Tank (1 No per PSS) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33249/2020
Power Transformers Foundation suitable for upto 3.15 MVA (2 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33239/2020
Substation Transformer Foundation (1 No)
VCB Foundation (5 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33241/2020
Foundation of R.S. Joist supports (16 Nos) as per drawing of HPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33243/2020
Foundation of CT, PT & LA (14Nos) as per drawing of HPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33242/2020
Outdoor Cable Trench ( 80 mtr Per PSS) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33245/2020
Indoor Cable Trench ( 30 mtr trench per PSS) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33247-48/2020
Cost Of Boundary Wall (200Meter/Pss) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33251-52/2020
Main Gate & Sub-Station Yard Gate(1 Nos) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33253/2020
Spreading of gravells/ Shingles in yard (30CUM ) as per drawing of HPSEBL/SEDES/SSD-478/2021-22-7972-79/2021
Formation of drainage system around the substation around 60x40mtr yard (200 Meter) as per drawing of
Firewall Protection as per drawing HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33244/2020
Chain Link Fencing with wooven mesh of GI wire 15MX30M
Cost of Soil Testing & Contour plans & design
Site Development work 33/11 kV, 2 x 3.15 MVA sub station (Manned) at Mubarakpur under Electrical Sub Division HPSEBL
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : on W.B.M. @ 0.75 Kg / sqm
Providing and laying bituminous macadam using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site by tippers, laid over a previously prepared surface with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge. 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 3.50% (percentage by weight of total mix) prepared in Drum Type Hot Mix Plant of 60- 90 TPH capacity.
Providing and laying semi- dense Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in- Charge. 25 mm compacted thickness with bitumen of grade VG- 30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100- 120 TPH capacity.
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. 450 mm dia RCC pipes.
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand: 10 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Construction of Rigid Pavement/interlocking block pavement road along with Drain
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller includingmaking good the undulations etc. and re-rolling the subgrade and disposal of surplus earthwith lead upto 50metres
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in flooring , below plinth, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand) : 6 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in- Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Site Developement work at 33/11 Kv Substation Leharli under electrical Division,HPSEBL,Gagret
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller includingmaking good the undulations etc. and re-rolling the subgrade and disposal of surplus earthwith lead upto 50metres
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in flooring , below plinth, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand) : 6 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in- Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Yard Road and Approach Road
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on new work.
Site development and providing retaining walls for proposed 33/11KV Sub Station Dhagwar 33 kV Sub-Station under Elecrical Sub-Division No-II under Electrical Division HPSEBL Dharamshala, Distt. Kangra.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand): 10 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form work for retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter.
Approach Road/Yard Road
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position bitumen hot sealing compound for expansion joints etc. using grade ‘A’ sealing compound.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Site development33/11KV Sub Station Gamru 33 kV Sub-Station under Elecrical Sub-Division No-I under Electrical Division, HPSEBL Dharamshala, Distt. Kangra.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand): 10 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form work for retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter.
Hume Pipe Culvert & Road ( Rd. 0.00 to 49.00m) to proposed 33/11 kv 2x 6.3 MVAS/Stn under Elecrical Sub-Division No-I under Electrical Division HPSEBL Dharamshala,
Eathwork in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.Ordinary rock
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete
Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets,kerbs and steps et
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing 1:5:10 (1 cement : 5 coarse sand) : 10 graded stone aggregate 40 mm nominalsize)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
Supplying and stacking at site 63 mm to 45 mm size stone aggregate
Laying, spreading and compacting stone aggregate ofspecified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled load/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering andncompacting to the required density .
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels required including consolidation finishing and tamping complete
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth leve hard steel wires
Site development for proposed 33/11KV 2x 1.6 mva Unmanned Sub Station at Daulatpur, Tehsil & Distt. Kangra under Elecrical Sub-Division Ranital under Electrical Division HPSEBL Kangra, Distt. Kangra.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form work for retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. 50 % all kind soil and 50% ordinary rock
Road for proposed 33/11KV 2x 3.15 mva Unmanned Sub Station at Daulatpur, Tehsil & Distt. Kangra under Elecrical Sub-Division Ranital under Electrical Division HPSEBL Kangra, Distt. Kangra
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on new work.
Site Development Work of 33/11KV Sub Station Neugal Café under Elecrical Sub-Division No 1 under Electrical Division HPSEBL Palampur, Distt. Kangra
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. Ordinary Rock.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) Medium shade pigment using 50% white cement 50% Grey cement
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size)
Cement concrete road for proposed 33/11KV Sub Station Neugal Cafe under Elecrical Sub-Division No 1 under Electrical Division HPSEBL Palampur, Distt. Kangra.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position bitumen hot sealing compound for expansion joints etc. using grade ‘A’ sealing compound.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on new work.
Site development retaining wall for Const. 33/11 KV Sub- Station at Neugal Café under Electrical Division , HPSEB Ltd. Palampur
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas ( exceeding 30cm in depth ,1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. hard rock (requiring blasting)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30*30 *5mm in Vertical surfaces such as wall (any thickness) and the like .
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
stone filling behind the R/wall with hard stones of app quality.
P/F PVC pipe 4" dia in weap holes @1.00 M o/c in staggered
Excavation in earth work and filling in 15cm layers in foundation and plinth i/c ramming watering and consolidating upto a lead of 20 mtrs.s lift upto a 1.5 mtrs.
site develeopement for new 33/11 KV , 2X3.15 MVA Sub Station at Banoru under Electrical Division HPSBEL Baijnath
Retaining wall
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas ( exceeding 30cm in depth ,1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. hard rock (requiring blasting)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30*30 *5mm in Vertical surfaces such as wall (any thickness) and the like .
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
stone filling behind the R/wall with hard stones of app quality.
P/F PVC pipe 4" dia in weap holes @1.00 M o/c in staggered
Excavation in earth work and filling in 15cm layers in foundation and plinth i/c ramming watering and consolidating upto a lead of 20 mtrs.s lift upto a 1.5 mtrs.
C.C. Road
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size)
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position bitumen hot sealing compound for expansion joints etc. using grade ‘A’ sealing compound.
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Foot Bridge
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30*30 *5mm in Vertical surfaces such as wall (any thickness) and the like .
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size)
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Excavation in earth work and filling in 15cm layers in foundation and plinth i/c ramming watering and consolidating upto a lead of 20 mtrs.s lift upto a 1.5 mtrs.
Aug to 2X3.15 (Chebb in Kangra Circle,Saloni in Dalhausi Circle) -Total=2Nos
Power Transformer (3.15 MVA/1.6 MVA, 33/11 kV, ONAN, OLTC, Outdoor)
33 kV Isolator (1250 A, 25kA, without Earth Switch) Motorised
33 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO, Porcelain)
33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ)
11 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured) {Transformer to 11 kV Bus} {50m+ Spare- 50m}
11 kV Cable Termination Kit (400 mm², Outdoor)
11 kV Cable Termination Kit (400 mm², Indoor)
CIVIL WORKS
Transformers Foundation [Power X-former]
Baffle wall in case of 2 No. Transformer
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
Aug to 10 mVA (Daulatpur in Una Circle)
Power Transformer (10 MVA, 33/11 kV, ONAN, OLTC, Outdoor)
11 kV Cable (11 kV, 630 mm², XLPE, Single Core, Armoured) {Transformer to 11 kV Bus} {50m+ Spare- 50m}
11 kV Cable Termination Kit (630 mm², Outdoor)
11 kV Cable Termination Kit (630 mm², Indoor)
CIVIL WORKS
Transformers Foundation [Power X-former]
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
ELECTRICAL VECHICLE CHARGING SUBSTATION
New 33/11 KV Sub Station
1X3.15MVA ( HRTC Workshop in Una Circle )Total =1No
Power Transformer (3.15 MVA, 33/11 kV, ONAN, OLTC, Outdoor)
Sub Station Transformer (100 kVA, 33/0.4 kV)
33 kV Switchgear & Allied Equipment
a) 33 kV Control and Relay (CR) Panel (with Numeric Differential Relay, IEC 61850)
b) 33 kV Control and Relay (CR) Panel (33 kV Incomer Bus) [Numeric Relay, IEC 61850]
c) 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type)
d) 33 kV Isolator (1600 A, 25kA, with Earth Switch) (Moterised)
e) 33 kV Isolator (1600 A, 25kA, without Earth Switch) (Moterised)
f) 33 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO, Porcelain)
g) 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ)
h) 33 kV Potential Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ)
i) 33 kV Drop Out Fuse Unit (33 kV, Expulsion)
11 kV Switchgear and Allied equipment: 01 No. incomer Bus
a) 11 kV incomer Bus: Control and Relay (CR) Panel with VCB (12 kV, 1250 A, 25KA) [Numeric Relay, IEC 61850]
b) 11 kV Incomer Bus: Potential Transformer (11 kV/110V, 3Φ, Indoor)
c) 11 kV LA/ Surge Arrester (9 KV, 10 kA ,Station Class, ZnO, Porcelain, Outdoor)
d) 11 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured) {Transformer to 11 kV Bus} {50m}+Spare
e) 11 kV Cable Termination Kit (400 mm², Outdoor)
f) 11 kV Cable Termination Kit (400 mm², Indoor)
11 kV Switchgear and Allied equipment: Single (2 No.) Outgoing Feeder
a) 11 kV Outgoing Feeder: Control and Relay (CR) Panel with indoor VCB (12 kV, 1250 A, 25KA) including CT
b) 11 kV Isolator (12 kV, 1250 A, 25 kA, with Earth Switch, Outdoor)
c) 11 kV LA/ Surge Arrester (9 kV, 10 kA Station Class, ZnO, Porcelain, Outdoor)
d) 11 kV Cable (11 kV, 185 mm², XLPE, Three Core, Armoured) {Busbar VCB to Isolator} {50m+ Spare- 50m}
e) 11 kV Cable Termination Kit (185 mm², Outdoor)
f) 11 kV Cable Termination Kit (185 mm², Indoor)
LT Cable (1.1 kV, 3.5 Core, 70 mm2) {from Station Tfr}
Capacitor Bank (3-Ф, 50 Hz, 1200 KVAr) [ IS:2834 ]
Automatic Capacitor Switch (12 kV, 1250 A, 25 kA) [REC Spec. 20/1981]
Battery Bank with Dual FCBC Battery Charger (15 No x 2V Cell, Lead Acid, 30 V, 200 AH)
Distribution Panel (30V, DC)
Distribution Panel (415 V, AC)Distribution Panel (415 V, AC) 200 Amp as incomer MCCB & 6 Nos 63 Amp MCCB as outgoing with voltmeter and Ammeter of 0.5 accuracy class alongwith phase indicating lamps of accuracy class 0.5
Super Strcture and Bus Bar Arrangement
(i) R.S. Joists, size 12800x250x125 mm 8 supports
(ii) R.S.Joists, size 4200x250x125 mm supports for Power Transformer's LA, Station Transformer LA, I/C, Power Transformer's CTs
(iii) M.S. channel iron 125x65 mm, X-arm @13.1 kg/m at 5% wastage for Bus-bar,Isolators,CT, LA's transformer etc. =100
(iv) M.S. angle iron 65x65 X-arm @ 5.8 kg/m & 5% wastage for body supports belt of Station transformer including 5% wastage
(v) Nuts & Bolts with Washers off sizes
BUS-BAR
(i) 3 Disc insulators Tension String complete with fitting
(ii) ACSR conductor 200 mm² at 10 % wastage
For jumpers at 2 m average 15 nos I.e.
(iii) Tee connections
(iv) PG clamps
Gantry for 2 no. outgoing feeder
(a) Steel tubular pole 11 m long for 1 No. out going Feeder
(b) RCC muffs (2000mm) & concreting thereof for 1 No. out going Feeder
(a)4.2 m long M.S. channel iron 100X50X5 mm 9.56 kg/m Cross arms for Sub-Station With 1 No. out going Feeder (11Kv)
(b) M.S. angle iron 50X50X6 mm 4.5 kg/m Cross arms for Sub-Station With 1 No. out going Feeder [ 4.2x3+5.33x2] (11kV)
(d) M.S. Half clamps
(e) Full Clamp
(f) Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
ACSR 100 mm² conductor for Jumpers [approx. 4 mtr/ phase]
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors)
Clamps for 1 Nos. out going Feeder
11 kV Isolator Moterised
Earthing of 33/11KV Substation
Earthing of 33 kV yard & equipment & 22 kV or 11kV panels M.S. flat 50x6 mm,wt. 2.4 kg/m At 5% wastage:- (a) Transformer Earthing at 3 points for 2 Nos Power Transformers (body & neutral) at 10 Mtr each 2X(3x10)x1.05=63 Mtr (b) For 4 No. LA's at 4.2 Mtr each 2X4.2x2x1.05=17.64 Mtr (c) For 22 nos. 33 kV super structure at 11.50 Mtr each 22x11.50x1.05 =265.65 Mtr i.e. 266 Mtr (d) For 32 Nos. VCB & CT body earthing at 10 m Each (32x10)x1.05 = 336 Mtr Total =682 mtr. i.e. 682X 2.4= 1638 ie 1.638 MT
GI Wire 6 No. SWG for screening etc.
Eye Block for screening
Tumbuckle for screening
GI Pipe 50 mm dia with holes of 16mm dia at 150 mm for centre to centre for 2 m distance from bottom For Transformer and for 11KV panels and fencing and Fixing of GI pipe 50mm with earth pit 10 nos per PSS Providing Coal=125 kg,Charcoal 23 kg ,Salt 122 kg,Sand 84 kg in each Earth Pit(Earth Pit Material)
MS plates 150x150x6mm for two connection
50x6 mm MS Flat connection with the mat to mat
Nut and bolts galvanized various sizes
Chequered plate cover 500x500x6mm i.e.11.8Kg
Providing MS Rod 40 mm dia 6 mtr long for Earth Matt Rods )(weight 9.9 kg per mtr) 16x6x9.9=950kg and Digging of 6 meter pits for earth rods 40 mm dia
Yard Lighting:-a) 9 m, Steel Tubular poles for yard lighting
b)18 W LED Lamp complete with fittings
c)Post Erection for gate
d)Clamps for GI pipe bracket
e)Underground cable 16 mm² for yard lighting
f)PVC cable size 6 mm² for connecting LED lamp supply
g)Junction box i/c MCCB and other allied
Lighting Emergency (3 No LED Bulbs with holders / wire)
control cable: 2x2.5 mm²
control cable: 4x2.5 mm²
control cable:12x2.5 mm²
3.5 core 95 mm² aluminium cable suitable for 415 V, AC
Fire Fighting Equipments as per TS
Safety Equipments & T & P as per TS
Civil Works
Control Room one Storey Building Sizes(14.7x14.8)sqm as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33202/2018
water supply and sanitary installation for Control Room Building.
Electrical Installation for control room building (for 60 points)
Septic Tank (1 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33254/2020
Rain Water Harvesting Tank (1 No per PSS) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33249/2020
Power Transformers Foundation suitable for upto 3.15 MVA (2 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33239/2020
Substation Transformer Foundation (1 No)
VCB Foundation (5 Nos) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33241/2020
Foundation of R.S. Joist supports (16 Nos) as per drawing of HPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33243/2020
Foundation of CT, PT & LA (14Nos) as per drawing of HPSEBL/SE(D)//ESHPSEBL/HAMIRPUR/33242/2020
Outdoor Cable Trench ( 80 mtr Per PSS) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33245/2020
Indoor Cable Trench ( 30 mtr trench per PSS) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33247-48/2020
Cost Of Boundary Wall (200Meter/Pss) as per drawing of HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33251-52/2020
Main Gate & Sub-Station Yard Gate(1 Nos) as per drawing of HPSEBL/SE(D)/ESHPSEBL/HAMIRPUR/33253/2020
Spreading of gravells/ Shingles in yard (30CUM ) as per drawing of HPSEBL/SEDES/SSD-478/2021-22-7972-79/2021
Formation of drainage system around the substation around 60x40mtr yard (200 Meter) as per drawing of
Firewall Protection as per drawing HPSEBL/SE(D)/ES HPSEBL/HAMIRPUR/33244/2020
Chain Link Fencing with wooven mesh of GI wire 15MX30M
Cost of Soil Testing & Contour plans & design
Site development Sub-station for Sop to charging station at HRTC Workshop Rampur under ESD HPSEBL Santokhgarh.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm.
Supplying, filling, spreading & leveling gravels of approved size in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.
Aug to1X6.3 MVA (Bharwain in Una Circle)Total =1 No.
Power Transformer (6.3 MVA, 33/11 kV, ONAN, OLTC, Outdoor)
33 kV Switchgear & Allied Equipment: with 01 No., 33 kV Incomer
33 kV Control and Relay (CR) Panel (with Numeric Differential Relay, IEC 61850)
33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type)
33 kV Isolator (1250 A, 25kA, without Earth Switch)Motorised
33 kV LA /Surge Arrester (30 kV, 10KA, Station class, ZnO, Porcelain)
33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ)
11 kV Cable (11 kV, 400 mm², XLPE, Three Core, Armoured) {Transformer to 11 kV Bus} {50m+ Spare- 50m}
11 kV Cable Termination Kit (400 mm², Outdoor)
11 kV Cable Termination Kit (400 mm², Indoor)
EARTHING (33 kV Sub-Station)
Additional Control cable
4 core 2.5 mm2
2 core 2.5 mm2
12 core 2.5 mm2
Cost is inclusive of dismantaelling of existing infra and depositing all Dismantalled Material back to Concerned Store as per direction of Engineer In Charge,
New 33 KV Single Circuit Line with Dog Conductor on STP for EV Charging station
ACSR 6/1/4.72 (100mm²) {Includes 3 conductor lengths for 3Φ and Additional 1% (Sag, Jumpering and wastage}
New 33 KV Single Circuit Line with Dog Conductor on STP
Muffs with concerete filling
X-Arms: [MS Channel Iron (100x50x6 mm, Length: 3250 mm i/c tolerance 100 mm on either side] x 10 No. Structures
Disc insulator String (Suspension) sets: 3 No. Discs in each string: ^^(Porcelain, CT, 12 kV, 90 kN) including dead end clamps etc)x (Single circuit : 3No conductors) x 1 No sides) /Run Throu' structures.
Belt Set - MS Angle Iron: 65x65x6, Length:(1800 mm) x 2 No.
X-Bracing Set - MS Angle Iron: 50X50x6, Length [2700 mm) x 2 No.]
Belt Set - MS Angle Iron: 65x65x6, Length:(1800 mm) x 2 No.
X-Bracing Set - MS Angle Iron: 50X50x6, Length [2700 mm) x 2 No.]
X-Arm (Horizontal) - MS Channel Iron: (100x50x6 mm), Length: 3250 mm i/c tolerance 100 mm on either side x 2 No.]
Disc insulator String (Strain) sets: 3 No. Discs in each string: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (Single Circuit: 3 No. conductors) x (2 No. sides) /Dead Structures
33 kV Pin Insulators (Porcelain, 36 kV, 10 kN): 3 No per double pole structure
Stay set complete in all respect (2 No./Run Thro & 4 No. / Dead End)
Stay Wire (7/4.00 mm) (10 kg Per Stay Set)
HT Earthing set complete
Earth wire (GI, 6 SWG) {Includes Single wire length and Additional 1% (Sag and wastage)}@ 150 kg/km
Eye Hook for earth wire
Earth Reel
MS Channel Iron: 75x40x6, Length :3300 mm
Half clamps: [On Double Pole Dead End structure: 6 No, Double Pole Run Thro' structure: 8 No]
Full clamps: [On Double Pole Dead End structure: 4 No, Double Pole Run Thro' structure: 4 No]
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 20 mm Φ or more (with flat and spring washers)]
Barbed wire
Danger Plate (203X200X1.6mm)
Red Oxide
Aluminium Paint
Bidder Name
Amount in Words
NCC LIMITED
STERLING AND WILSON PRIVATE LIMITED
JAKSON LIMITED
M/s. Vijai Electricals Limited
Rail Vikas Nigam Limited
NCC LIMITED
M/s. Vijai Electricals Limited
JAKSON LIMITED
STERLING AND WILSON PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid