Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC DULALPUR PO MADHYASHIBPUR MAGRAHAT SOUTH 24 PARGANAS WEST BENGAL 743372 | 24 PARAGANAS SOUTH | WEST BENGAL | 743372 | L1 | Accepted-AOC LOWEST BIDDER WITHOUT GST | |
| 2 | L2₹5.0 L−₹84,321 (14.4%)Rejected-Finance | L2 | Rejected-Finance Rejected. Amount quotated without GST | |
| 3 | L3₹5.7 L−₹21,004 (3.58%)Rejected-Finance 245 1A SATIN SEN SARANI KOLKATA 700054 | KOLKATA | KOLKATA | WEST BENGAL | 700054 | L3 | Rejected-Finance Rejected for credential . Without GST amount more than L1 | |
| 4 | L4₹5.0 L−₹82,821 (14.1%)Rejected-Finance | L4 | Rejected-Finance Rejected.Amount quotated without GST | |
| 5 | L5₹6.9 L+₹1.0 L (17.8%)Rejected-Finance 36 MASCARENH BUILDING M G ROAD PANAJI GOA | NORTH GOA | GOA | 403001 | L5 | Rejected-Finance Highest amount |
Tender Value
₹5.0 L
EMD Value
₹9,962
Closing Date
18 Oct 2022, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
PRODHAN MAJHIPARA PALASHI GP
MAJHIPARA PALASHI GP MAJHIPARA NORTH 24 PARGANAS PIN 743145
PURCHASE OF INSTRUMENT OF MATERIALS TESTING LAB
2022_ZPHD_412152_1
878/MPGP/15THFC/2022
Open Tender
Laboratory and scientific equipment
Item Rate
10 days
MAJHIPARA PALASHI GP OFFICE
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹9,962
Yes
17 Nov 2022
29 Sept 2022
20 Oct 2022
29 Sept 2022
18 Oct 2022
29 Sept 2022
60 days
Compressive strength testing machine electrically operated (digital), capacity: 1000 KN.Least count: 1 KN. Accuracy +/- 1 % of the applied load conforming to IS 14858:2000. (HAND OPERATED
Vicat apparatus conforming to IS : 5513-1996
Gauging Trowels 10 nos
Pycnometer conforming to IS: 2386 (Part III)-1963
Le chateliar's flask conforming to IS : 4031 ( Part 3) - 1988
Blaine's Air Permeability apparatus with accessories conforming to IS: 5516
Concrete core cutter machine(As per relevant IS code)
Accelerated curing tank
Electronic Weighing Balance (digital), capacity 5 KG, Sensitivity 500 mg. Calibrated. Pan siz 12 inch x 12 inch
Thermostatically controlled Hot air oven with Digital Indicator & Blower 300x300x300 mm . Inside chamber made with stainless steel. Capacity: ambient to 250 degree celcius. Temperature accuracy +/- 1 degree Celcius
4 nos.Metal Tray of size larger than 650 cm2/ 12 inch x 12 inch/ 12 inch x 18 inch
Thermometer 0 to 350° C , sensitivity 0.1° C.
Penetration testing apparatus of bitumen with container, needle, stop watch, water bath with thermostat, thermometer as specified in IS: 1203-1978
Cleveland flash & fire point tester/ Pensky-martens closed tester consist of cup, lid, stirrer device, shutter, flame exposure device & all the apparatus conforming to IS:1209-1978
Ring & ball apparatus,steel balls(2 nos.), Brass rings (2 nos.) and all the apparatus as specified in IS: 1205:1978 to determine the Softening point of bitumen
Casagrande apparatus confirming to IS: 9259-1979 & other apparatus required to determine the Liquid limit & Plastic limit as specified in IS: 2720 (Part-5) 1985.
Cylindrical metal mould (for standard & modified proctor test) with 2.5 kg & 4.5 kg rammer and all the required apparatus to determine optimal moisture content of soil for proctor conforming to IS 2720-7 & IS 2720-8
Standard penetration test apparatus of soil conforming to IS: 2131 (1981)
Digital Moisture Meter (Hand held)
Polycarbonate Beakers(50 ml) 5 Nos.
Polycarbonate Beakers(100 ml) 5 Nos.
Metal Tray 12"x12" 2 Nos. & 12"x18" 2 Nos
Hydrometer conforming to IS : 2720 ( Part 4 ) - 1985
Specific Gravity bottle (100 ml) 4 Nos.
Digital Turbidity meter (Table top type) conforming to IS : 3025 ( Part 10) - 1984
Digital conductivity meter conforming to IS : 3025 (Part 14) - 1984
Digital TDS meter conforming to IS 3025 (PART 16) : 1984
Digital DO meter conforming to IS 3025 ( Part 38 ) : 1989
Drinking waterfield testing kit to determine Turbidity, Total hardness, Arsenic, Dissolved oxygen.
Cylindrical Metal measure with handle for determination of Bulk Density of Aggregates, Capacity- 3,15,30 litres and tamping rod of 16 mm dia & 60 cm long
Aggregate Impact testing machine with all the apparatus specified in IS: 2386(4)
Metal Flakiness Gauge to determine Flakiness Index of Coarse Aggregate conforming to IS:2386(Part I)-1963
Metal Gauge to determine Elongation Index of Coarse Aggregate conforming to IS:2386(Part I)-1963
Los Angeles abrasion testing machine conforming to IS: 10070-1982 with all the apparatus specified in IS: 2386 (4)
Aggregate crushing value determination apparatus with all the accessories specified in IS: 2386(4)
Laboratory California Bearing Ratio (CBR) test apparatus with all the accessories specified in IS 2720-16 (1987) with CBR mould and it's accessories conforming to IS 9669 (1980), Three speed or four speed motor, MS mould
Set of IS Sieves mentioned in Table I of IS: 2386 part-I - 1963 conforming to IS : 460-1962 with Pan & Lid GI-75,63,53,45,37.5,31.5,26.5,22.4,13.2,4.75,10, with Pan & 36 37 Lid BRASS- 4.7,2.36,2.00,1.18,1.00 MM, 75, 600,300,150 Micron LID & PAN
Mechanical sieve shaker (table top type)
5 nos. of dry cloth larger than 750 mm x 450 mm
M/S- UJJWAL SARKAR
KRISHNA ENTERPRISES
SALES POINT
Lawrence and Mayo (India) Pvt. Ltd.
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .