Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAdmitted-Finance | ₹41.0 L | L1 | Admitted-Finance |
| 2 | L2₹42.5 L+₹1.5 L (3.59%)Admitted-Finance NOT AVAILABLE | ₹42.5 L+₹1.5 L (3.59%) | L2 | Admitted-Finance |
| 3 | L3₹43.6 L+₹2.6 L (6.38%)Admitted-Finance | ₹43.6 L+₹2.6 L (6.38%) | L3 | Admitted-Finance |
| 4 | L4₹44.3 L+₹3.3 L (7.97%)Admitted-Finance L N B ROAD SRIPURIA P O P S TINSUKIA ASSAM 786125 D 50 ADG NEI GUWAHATI | TINSUKIA | ASSAM | 786125 | ₹44.3 L+₹3.3 L (7.97%) | L4 | Admitted-Finance |
| 5 | L5₹49.7 L+₹8.8 L (21.4%)Admitted-Finance | ₹49.7 L+₹8.8 L (21.4%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s. Chanda Construction L4 | M L TREATMENTS L8 | MANASEE L1 | PRADIP CHANGMAI L3 | ABOTANI ENTERPRISE L9 | SATYA CHANGMAI L2 | Saranga Saikia L6 | R K ENGINEERING ASSEMBLE L7 | GHANA KRISHNA BORA L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. | 344 | Point | 50 ₹17,200 | 65 ₹22,360 | 65 ₹22,360 | 40 ₹13,760 | 155 ₹53,320 | 35 ₹12,040 Lowest | 170 ₹58,480 | 65 ₹22,360 | 105 ₹36,120 |
| 2.00 | Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed. | 380 | RM | 86 ₹32,680 | 105 ₹39,900 | 80 ₹30,400 | 65 ₹24,700 | 150 ₹57,000 | 50 ₹19,000 Lowest | 100 ₹38,000 | 110 ₹41,800 | 107 ₹40,660 |
| 3.00 | M & L for Point wiring for one light/exhaust fan/fan point/call bell controlled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.
(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) | 151 | Point | 1,290 ₹1,94,790 | 1,364 ₹2,05,964 | 1,290 ₹1,94,790 | 1,200 ₹1,81,200 | 1,535 ₹2,31,785 | 1,135 ₹1,71,385 Lowest | 1,536 ₹2,31,936 | 1,245 ₹1,87,995 | 1,700 ₹2,56,700 |
| 4.00 | All as per item No. 03 mentioned here-in-before but for One 3/5 pin socket outlet 6 amps on independent board complete ditto | 14 | Point | 1,290 ₹18,060 | 1,444 ₹20,216 | 1,320 ₹18,480 | 1,229 ₹17,206 | 1,411 ₹19,754 | 1,180 ₹16,520 Lowest | 1,439 ₹20,146 | 1,445 ₹20,230 | 1,650 ₹23,100 |
| 5.00 | All as per item No. 03 mentioned here-in-before but for One 3/5 pin socket outlet 6 amps point on same board complete ditto | 13 | Point | 410 ₹5,330 | 455 ₹5,915 | 350 ₹4,550 | 326 ₹4,238 | 365 ₹4,745 | 325 ₹4,225 Lowest | 345 ₹4,485 | 465 ₹6,045 | 700 ₹9,100 |
| 6.00 | All as per item No. 03 mentioned here-in-before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto | 26 | Point | 1,380 ₹35,880 Lowest | 1,717 ₹44,642 | 1,640 ₹42,640 | 1,445 ₹37,570 | 1,799 ₹46,774 | 1,390 ₹36,140 | 1,799 ₹46,774 | 1,720 ₹44,720 | 2,100 ₹54,600 |
| 7.00 | M&L for point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm FRLH/S in and including concealed PVC conduit 20 mm dia medium duty ISI marked with all necessary fittings with sunken cast iron /pressed steel terminal box ,flush to surface of 1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan/bell controlled by one switch complete including cutting, chasing the surface and then making good the same in CM 1:3 to finishing the match surface complete all as specified and directed by Engr- in-charge.
(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) | 101 | Point | 1,355 ₹1,36,855 | 1,566 ₹1,58,166 | 1,520 ₹1,53,520 | 1,343 ₹1,35,643 | 1,897 ₹1,91,597 | 1,210 ₹1,22,210 Lowest | 1,860 ₹1,87,860 | 1,520 ₹1,53,520 | 2,400 ₹2,42,400 |
| 8.00 | All as per item No. 07 mentioned here-in-before but for One 3/5 pin socket outlet 6 amps on independent board complete ditto | 12 | Point | 1,365 ₹16,380 | 1,616 ₹19,392 | 1,520 ₹18,240 | 1,367 ₹16,404 | 1,800 ₹21,600 | 1,250 ₹15,000 Lowest | 1,800 ₹21,600 | 1,620 ₹19,440 | 2,200 ₹26,400 |
| 9.00 | All as per item No. 07 mentioned here-in-before but for one point controlled by two, two way swiches with cables of 1.5 sqmm size complete all as directed and specified | 3 | Point | 1,400 ₹4,200 | 1,591 ₹4,773 | 1,510 ₹4,530 | 1,394 ₹4,182 | 1,821 ₹5,463 | 1,380 ₹4,140 Lowest | 1,820 ₹5,460 | 1,580 ₹4,740 | 2,456 ₹7,368 |
| 10.00 | All as per item No. 07 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto | 24 | Point | 1,430 ₹34,320 Lowest | 1,919 ₹46,056 | 1,950 ₹46,800 | 1,499 ₹35,976 | 1,975 ₹47,400 | 1,440 ₹34,560 | 1,960 ₹47,040 | 1,920 ₹46,080 | 1,960 ₹47,040 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
21 Jul 2026, 6:00 pmClosed
GE 872 EWS
GE 872 EWS PIN 913872 C/O 99 APO
REPAIR AND MAINT TO INTERNAL ELECTRIFICATION AT RAYANG MIL STN UNDER GE 872 EWS
2026_MES_773915_1
8859/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
LIKABALI
All as per NIT and Tender documents
7 documents required · 7 mandatory
₹500
Yes
GE 872 EWS
₹96,000
Yes
1 Aug 2026
22 Jun 2026
23 Jul 2026
22 Jun 2026
21 Jul 2026
7 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. | 344 | Point | - | - |
| 2 | Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed. | 380 | RM | - | - |
| 3 | M & L for Point wiring for one light/exhaust fan/fan point/call bell controlled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.
(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) | 151 | Point | - | - |
| 4 | All as per item No. 03 mentioned here-in-before but for One 3/5 pin socket outlet 6 amps on independent board complete ditto | 14 | Point | - | - |
| 5 | All as per item No. 03 mentioned here-in-before but for One 3/5 pin socket outlet 6 amps point on same board complete ditto | 13 | Point | - | - |
| 6 | All as per item No. 03 mentioned here-in-before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto | 26 | Point | - | - |
| 7 | M&L for point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm FRLH/S in and including concealed PVC conduit 20 mm dia medium duty ISI marked with all necessary fittings with sunken cast iron /pressed steel terminal box ,flush to surface of 1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan/bell controlled by one switch complete including cutting, chasing the surface and then making good the same in CM 1:3 to finishing the match surface complete all as specified and directed by Engr- in-charge.
(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) | 101 | Point | - | - |
| 8 | All as per item No. 07 mentioned here-in-before but for One 3/5 pin socket outlet 6 amps on independent board complete ditto | 12 | Point | - | - |
| 9 | All as per item No. 07 mentioned here-in-before but for one point controlled by two, two way swiches with cables of 1.5 sqmm size complete all as directed and specified | 3 | Point | - | - |
| 10 | All as per item No. 07 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto | 24 | Point | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
Tenderpdf.pdf
Tender Documents • 0.90 MB
BOQ_866624.xls
BOQ • 0.47 MB
8859Corri.pdf
PDF • 0.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .