| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹44.1 L+₹35,594.43 (0.81%)Rejected-Finance 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR GUJARAT 361 005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹44.7 L+₹95,631.43 (2.19%)Rejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹51.0 L+₹7.3 L (16.8%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹52.1 L+₹8.5 L (19.3%)Rejected-Finance PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L5 | Rejected-Finance Being L5 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
26 Sept 2024, 6:00 pmClosed
GE I CG PORBANDAR
OPP BIRLA FACTORY GE (I) CG PORBANDAR
REPAIR MAINT REPLACEMENT OF INTERNAL AND EXTERNAL ELECTRIC SUPPLY WATER SUPPLY DG SET AC AND OTHER MISC ITEMS AT ICGS VADINAR UNDER GE (I) CG PORBANDAR
2024_MES_672330_1
8003A/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
VADINAR
AS PER NIT
9 documents required · 9 mandatory
₹500
GE I CG PORBANDAR
₹99,000
Yes
28 Nov 2024
5 Sept 2024
28 Sept 2024
5 Sept 2024
26 Sept 2024
20 Sept 2024
Amount
SCHEDULE 'A' E/M ITEMS
Servicing of DG set of Cap 100 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and directed by Engineer-in-Charge. (a) Lub oil filter. (b) Lubrication oil. Note: Defective parts if any other than listed at (a) to (b) above will be measured and paid separately
Supply only parts/ Items of DG set 100 KVA and taking down old unserviceable parts.
Oil Filter
Fuel Filter cum water seperator
Air Filter Safety
Air Filter Primary
Coolant
Engine Oil
Fuel strainer
Distilled water for battery
Supply only parts/ Items of DG set 82.5 KVA and taking down old unserviceable parts.
Oil Filter
Fuel Filter cum water seperator
Air Filter Safety
Air Filter Primary
Coolant
Engine Oil
Fuel strainer
Distilled water for battery
Comprehensive maintenance and repair of APFC panel by replacement of worn out spare parts and cleaning of the serviceable contactors and tightening/ checking of all internal electrical connections and accessories to maintain PF not less than 0.99 by adjusting/ calibrating the APFC relay of any type, complete all as specified and directed by Engineer-in-Charge. Note: Defective parts if any will be measured and paid seprately
Supply only items for APFC Panel and taking down old unserviceable parts.
Heavy duty gas filled Capacitor 5 KVAR, 440V, 3 phase, 50 Hz.
Heavy duty gas filled Capacitor 7.5 KVAR, 440V, 3 phase, 50 Hz.
Heavy duty gas filled Capacitor 10 KVAR, 440V, 3phase, 50 Hz.
8 Steps APFC Relay
Servicing of Servo Stabilizer oil cooled automatic type of capacity 30 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel level, supply system, Lubrication system, cooling system, rectification of defect if any and including replacement of following,complete all as specified and directed by Engineer-in-Charge. (a) Lubrication oil. (b) 3 Phase Digital display system
Servicing of Isolation transformer AN cooled automatic type of capacity 10 KVA by Rep of authorised service centre as per manufacturer manual and checking of supply system, Lubrication system, rectification of defect if any, complete all as specified and directed by Engineer-in-Charge.
Material and labour for painting of the tranformer 315 KVA complete by removing old paint by scrapping and providing spray painting two coat with synthetic enamel paint of approved make duly marking/writing MES/SM No., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for apply two coat of epoxy paint on LT Panel / LT APFC Panels/Servo stablizer of any size, including preparation of rusted surface of panel by means of sand paper/scrubing of dust etc and apply one coat of epoxy based primer before painting, complete all as specified and directed by Engineer-in-Charge. Note: Minor repair/ replacement of hinges suitable for screw fastners and fixed in original position deemed to be included in unit rate.
Supply and fixing in replacement Digital time switches(SST 15 min) for street light 215 V single Phase, complete all as specified and directed by Engineer-in-Charge. Make :L&T/Havells
Material & Labour for preparing old rusted surface of steel tubular pole by means of sand paper/scrubing of dust etc and applying one coat of red oxide on surface of poles and applying two coats of silver paint on Pole and numbering of poles with synthetic enamel paint white in 100mm high letters over 150 x 150mm black base, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement thermoplastic cable junction box for street lights of size 205 x 255 x 112mm including bus bar/terminal for cable connection with IP-66 protection,complete all as specified and directed by Engineer-in-Charge. Make : Hensel Cat No.DK 2525 G or its equivalent in Legrand/sintex
Material & Labour for bore Earthing 150mm bore for earthing with galvanised steel pipe electrode, 40mm bore, medium grade, 3 metres length, top edge of GI pipe 15 cm above GL, connected with earthing lead of 25 x 4 mm GI strip to the earthing test point and filling of charcol dust, salt etc and testing on completion, including taking down old unserviceable earthings, complete all as specified and directed by Engineer-in-Charge. Note: IR Value should be less than 5 Ohms. Note: GI earth stip of size 25 x 4 including installation 7.5 Mtr is deemed to be included in the unit rate.
Supply & Fixing in replacement of Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (heat shrinkable) and accessories suitable for 3½/ 4 core XLPE armoured Aluminium conductor cable of following sizes:-
25 Sqmm to 50 Sqmm
70 Sqmm to 95 Sqmm
Taking out unserviceable LT UG cables of any sizes from trenches, complete all as specified and directed by Engineer-in-Charge.
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross-sectional area.
150 Sqmm 3.5 Core
120 Sqmm 3.5 Core
95 Sqmm 3.5 Core
50 Sqmm 3.5 Core
35 Sqmm 3.5 Core
25 Sqmm 3.5 Core
16 Sqmm 4 Core
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out in hard/dense soil, complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading levelling watering and well Ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for cutting existing road/hard standing not exceeding 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well ramming watering finish surface 10 cm from top using PCC 1:2:4; including removal of surplase soil, complete all as specified and directed by Engineer-in-Charge.
Material and Labour for DWC pipe laying in trenches/ under floor/on walls for protection of UG cables of following sizes, complete with coupler and connected accessories, including taking down old unserviceable DWC pipe, complete all as specified and directed by Engineer-in-Charge. Note: (i) Cutting of floor/ road and making good with PCC deemed to be included in item rate Make: Rex/Poly/Geminie DWC pipe of following size:-
Supplying and laying in replacement synthetic Rubber insulated mats 2mm thick for voltage upto 3.3 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed by Engineer-in-Charge.
Supplying and laying in replacement synthetic Rubber insulated mats 2.5mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement MCCB 4 pole 100 Amps of Breaking capacity 16KA, complete all as specified and directed by Engineer-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate.
Supply and fixing in replacement MCCB 4 pole 63 Amps of Breaking capacity 16KA., complete all as specified and directed by Engineer-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate.
Supply and fixing in replacement MCCB 4 pole 160 Amps of Breaking capacity 25KA, complete all as specified and directed by Engineer-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate.
Supply and fixing in replacement of Contactor ML-3, 3 pole of cap 40 Amps, complete all as specified and directed by Engineer-in-Charge. Make : ABB/LT
Supply and fixing in replacement Aluminum lugs long barrel of size 150 Sqmm, complete all as specified and directed by Engineer-in-Charge. Make: Dowells or equivalent
Supply and fixing in replacement Aluminum lugs long barrel of size 120 sqmm, complete all as specified and directed by Engineer-in-Charge. Make: Dowells or equivalent
Supply and fixing in replacement Aluminum lugs long barrel of size 95 Sqmm, complete all as specified and directed by Engineer-in-Charge. Make: Dowells or equivalent
Supply and fixing in replacement Aluminum lugs long barrel of size 70 Sqmm, complete all as specified and directed by Engineer-in-Charge. Make: Dowells or equivalent
Supply and fixing in replacement Aluminum lugs long barrel of size 50 sqmm complete all as specified and directed. Make: Dowells or equivalent
Supply and fixing in replacement Aluminum lugs long barrel of size 35 Sqmm, complete all as specified and directed by Engineer-in-Charge. Make: Dowells or equivalent
Supply and fixing in replacement Aluminum lugs long barrel of size 25 Sqmm, complete all as specified and directed by Engineer-in-Charge. Make: Dowells or equivalent
Cutting & removing existing joint and supply, jointing and testing outdoor type Heat shrinkable straight through cable joint including all material and accessories suitable for 3 core x 120 Sqmm XLPE cable of 11000 volts grade, complete all as specified and directed by Engineer-in-Charge.
Cutting & removing existing joint and supply, jointing and testing outdoor type Heat shrinkable straight through cable joint including all material and accessories suitable for 3 core x 95 Sqmm XLPE cable of 11000 volts grade, complete all as specified and directed by Engineer-in-Charge.
Cutting & removing existing joint and supply, jointing and testing indoor type heat shrinkable end termination cable joint including all material and accessories suitable for 3 core x 120 Sqmm XLPE cable of 11000 volts grade, complete all as specified and directed by Engineer-in-Charge.
Cutting & removing existing joint and supply, jointing and testing indoor type heat shrinkable end termination cable joint including all material and accessories suitable for 3 core x 95 Sqmm XLPE cable of 11000 volts grade, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Dehydration/Filteration of tranformer oil at site by means of centrifuging machine in order to improve di-electric strength of oil as per IS-355. Break down voltage should not be less than 50 KV, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Transformer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement, complete all as specified and directed by Engineer-in-Charge. (Oil should be supplied in sealed barrel of Power/Transol brand) Note: oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations.
Disconnecting the transformer of capacity 315 KVA from HT/ LT system and opening carefully for rectifying the leakage by replacing the unserviceable spare parts and complete assembling after repairs including testing for any oil leakages, proper functioning and connecting the HT/ LT system, Complete all as specified and directed by Engineer-in-Charge. Note:- Defective parts replaced will be measured and paid separately
Supply only parts/items for transformer 315 KVA
Supply and fixing in repair of LT bushings with brass studs.
Supply and fixing in repair of top cover gasket set.
Supply and fixing in repair of radiator flanged gasket 6 mm thick.
Supply and fixing in repair of oil level indicator gasket set.
Supply and fixing in repair of HT bushing with brass studs 11 KV.
Comperehensive maintenance of HT panel, detection of defective components, replacement of wornout parts and servicing/cleaning of mechanical components through authorised service centre of VCB manufacturer /OEM or skilled VCB repairing agency, re-insertion of trolly in HT panel, testing for smooth functioning, complete all as specified and directed by Engineer-in-Charge. Note: Worn out parts shall be measured & paid seperately under respective items.
Supply only parts/items for HT panel & taking down old unserviceable parts
Motor cut off Limit switch Make: BCH/L&T/C&S
Closing coil 24V DC Assembly
Shunt trip coil 24V DC
Removing the existing unserviceable neon indication lamps from HT 11 kV cubical panel and Supply and fixing LED neon indicator lamps assembly complete suitable for the panel, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of HT Voltmeter 0 to 15 KV (PTR 11 KV/ 110 Volt), size 135mm x 135mm, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of HT Ammeter 0 to 60 Amps 135mm x 135mm, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 11 KV single phase indoor resin cast PT of ratio 11 KV/rt 3/110V/rt 3V 3 Class 1.0, Burden 100 VA, insulation level 50 KV, voltage factor1.2 Cont and 1.5 for 30 Sec, conforming to IS-3156, complete all as specified and directed by Engineer-in-Charge.
Dismantling electric/water connection and taking down of storage type water heater of following capacity, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and refixing in situ, complete all as specified and directed by Engineer-in-Charge. Note: worn out parts shall be measured as separately.
Storage water heater of capacity 25 Litre
Storage water heater of capacity 15 Litre
Storage water heater of capacity 10 Litre
Supply only spare parts for Geyser & Taking down old unserviceable parts
Heating element upto 2 KW with rubber gasket .
Thermostat as per sample/suitable to 25/15/10 Ltrs capacity ISI marked.
Hot/Cold water connection pipe 450 mm length.
Geyser assembly as per sample suitable for 25 ltr capacity
Indication lamp red and green suitable for geyser as required
Supply & Fixing in replacement high quality indoor LED batten tube light fitting 10 Watt 2 feet long with aluminium extrusion housing, energy efficient T5, IP 20, epoxy powder coated CRCA sheet housing suitable for wall mounting with voltage range 100-240 volts and inbuilt protection, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement high quality indoor LED batten tube light fitting 20 Watt 4 feet long with aluminium extrusion housing, energy efficient T5, IP 20, epoxy powder coated CRCA sheet housing suitable for wall mounting with voltage range 140-270 volts and inbuilt protection, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement LED Luminaires recessed mounted down lighter 18 watt 5700K system efficiency not less than 100lm/watt, thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement 6/7 W LED spot light with multiple beam tilting angles, no UV radiation and dimmable ballast, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of LED flood light 150 Watt LM 6 high pressure die cast aluminium housing, IP 66, Nominal Lumen output 14000 lm, Colour temprature 5700K, THD<10%, PF>0.95, Operating Voltage 140-270V AC, 50HZ, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of LED street light of capacity 60 Watt, LM6 high pressure die cast aluminium housing, IP 66 protection, THD<20%, PF>0.95, Operating Voltage 140-270V AC, 50HZ, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement of LED building security light of capacity 30 watt, LM6 high pressure die cast aluminium housing, IP 66 protection, THD<20%, PF>0.95, Operating Voltage 140-270V AC, 50HZ, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement LED Bollard light Cool white 6500 K of wattage 14 watt with integrated mounting base plate and driver complete with housing dark grey RAL 7043 with long life time of 50,000 hours (70% lumen maintenance @ Tc = 35ºC), IP65 protection and IK10 impact resistance including PCC (1:2:4) foundation of suitable size for mounting of light fitting including mounting pole with accessories not less than 1.2m height, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement LED Bollard Light Cool White of wattage 11 Watt 6500 K with with integrated mounting base plate and driver complete with housing dark grey RAL 7043 IP 65 protection, Resistant to corrosion and Better optics for uniform distribution including PCC (1:2:4) foundation of suitable size for mounting of light fitting, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement LED Bollard light Cool white 6500 K of wattage 17 watt with integrated mounting base plate and driver complete with housing dark grey RAL 7043 with long life time of 50,000 hours (70% lumen maintenance @ Tc = 35ºC), IP65 protection and IK10 impact resistance including PCC (1:2:4) foundation of suitable size for mounting of light fitting including mounting pole with accessories not less than 1.2m height, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement square shape slim recessed mounted LED down light of capacity 33 Watt (2 ft x 2 ft) with die cast housing finished in white powder coating, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair Slim 07 Watt round LED panel light luminaire, nominal lumen output 800 lm, extruded aluminum housing, IP20, voltage range 140-270 volts PF>0.9, wall mounted, complete all as specified and directed by Engineer-in-Charge.
Taking down the old and rusted GI bracket and supply & fixing GI bracket of 40/25mm dia duly painted with two coat of supper enamelled paint over a coat of red oxide including suitable clamps nuts bolts and washers etc., complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement lSI marked RCBO conforming to IS: 12640 (Part 2)- 2016, having front face indication for earth leakage fault, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters of following rating, complete all as specified and directed by Engineer-in-Charge. Make: Legrand, Schneider
32 A, 30 mA, 230 V, DP RCBO
16 A, 30 mA, 230 V, DP RCBO
63 A, 30 mA, 415 V, FP RCBO
Supply and fixing in replacement MCB of following rating, complete all as specified and directed by Engineer-in-Charge.
5-32 Amp SP, 240 volt 'C' series, 10 KA
32 Amp SPN, 240 volt 'C' series, 10 KA
32 Amp TPN, 440 volt 'C' series, 10 KA
63 Amp TPN, 440 volt 'C' series, 10 KA
Supply and fixing in replacement of 3- layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & PN16 UV stablised and antimicrobial fusion welded having thermal stability for water supply all PP-R plain & brass threaded polypropylene random including fittings laid in Wall/ceiling/floors for 32mm bore dia pipe, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair PP-R Ball valves (brass insert) as per requirement of the site for 32mm dia bore pipe, complete all as specified and directed by Engineer-in-Charge.
Dismantling monoblock pump set centrifugal type of cap 25/20 HP, AC, 3 phase, 415 volts from site after disconnecting of electric connection, suction and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, dismantling pump set for overhauling, replacing u/s shaft sleeve, gland packing, bush, water seal, applying grease etc and reassembling the complete pump after repairs and replacement of parts as required, refixing the same at site including electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engineer-in-Charge. Note : Cost of dismantling and refixing deemed to be included in quoted rate.
Dismantling open well type monoblock pump set of cap 5/7.5/10 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enamelled copper wire as per existing gauge refixing the same at site including. electric and piping connections complete, checking for satisfactory working,complete all as specified and directed by Engineer-in-Charge. Note : Cost of dismantling and refixing deemed to be included in quoted rate.
Comprehensive maintenance of RO Water Plant of capacity 1000 Ltr/Hr servicing complete: (a) Replacement of minor parts such as SP stem, union male elbow, branch etc deemed to be included in quoted rate (b) Major parts will be measured and paid separately Make of RO Plant : Ion Exchange
Supply and fixing in replacement of following spares for RO water Plant 1000 Ltr/Hr :-
20" Sediment filter
Anti scalent chemical
Membrane 4040
Solenoid Valve
Sand filter media
Carbon media
Comprehensive maintenance of RO Water Plant of capacity 8000 Ltr/Hr servicing complete:- (a) Replacement of minor parts such as SP stem, union male elbow, branch etc deemed to be included in quoted rate (b) Major parts will be measured and paid separately Make of RO Plant : Ion Exchange
Supply and fixing in replacement of following spares for RO water Plant 8000 Ltr/Hr :-
Jumbo Filter 20"
Anti scalent chemical
Membrane
Strainer sheet extra long
Sand filter media
Carbon media NGMA
Supply and laying in repair speaker cable 2.5 Sqmm (transparent), complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair Wiring with 2.5 Sqmm, 3 Core, PVC insulated and FRLS PVC Round sheathed, copper conductor (flexible) industrial cable, 1100 Volts, conforming to IS-694, connecting light fittings/ terminals with copper lugs, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for replacement of defective current transformer resin casted two core double ration (One for protection and other core for metering equipment), ratio : 100/1-1A, Accuracy class 1/5P10, burden: 10 VA/10VA, STC:25 KA for 1 sec, Frequency : 50 Hz, as per existing Amps, for 11 kv, complete all as specified and directed by Engineer-in-Charge.
Annual Comprehensive maintenance, servicing and testing of Split type air conditioners of capacity 1.5 ton/2.0 ton of any make complete by cleaning cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing, oiling, greasing of blower motor, checking and removing any vibration and leakage ensure cutting of compressor / heater in case of failure of blower motor, Gas charging and testing after fixing at site, complete all as specified and directed by Engineer-in-Charge. Note:(a) Cost of any minor nature repair / items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc and labour required for removing / refixing including transportation of equipment and repair of PCB is deemed to be included in the unit rate of this items.
Supply and fixing in repair hermetic sealed rotary compressor with new compressor capacity not less than 19000 BTU/hr single phase, including gas charging in the system, complete all as specified and directed by Engineer-in-Charge. Make : Tecumseh/Toshiba
Supply and fixing in repair hermetic sealed rotary compressor with new compressor capacity not less than 24000 BTU/hr single phase, including gas charging in the system, complete all as specified and directed by Engineer-in-Charge. Make : Tecumseh/Toshiba
Material & Labour for rewinding of blower motor or condenser fan motor, replacement of wornout bushes, complete of split type air conditioner, complete all as specified and directed by Engineer-in-Charge. Note: Cutting of wornout wiring deemed to be included in unit rate
Taking down carefully by unscrewing the unserviceable DB Boxes, MC distribution boards SP & TPN with porcelain cut outs etc., complete all as specified and directed by Engineer-in-Charge.
Taking down the sub main wiring of any dia / Sqmm on teak wood batten / PVC conduit GI earth wire, complete all as specified and directed by Engineer-in-Charge.
Taking down old casing & caping, Flexible pipe and PVC conduit any type and size, complete all as specified and directed by Engineer-in-Charge.
Taking down carefully burnt out aluminium/copper circuit wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, etc to be measured and paid for seprately) making good to the disturbed surfaces of walls ceilings and floors etc., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for point wiring with PVC insulated and unsheathed cable 1.5 Sqmm (Nominal area) ISI marked stranded copper conductor single core in existing conduit including 1.5 Sqmm PVC insulated and unsheathed stranded copper cable to common earth and connecting to earth dolly including colour coding of cable shall be Phase-Red, Neutral- Black and Earth- Green complete all as specified and directed by Engineer-in-Charge. for the following:-
One light/fan point controlled by one, one way switch
One bell point controlled by push button on the same board with other switch.
One 5 pin socket outlet 5/6 amps on the same board.
One 5 pin socket oulet 5/6 amps on independent board..
Material & Labour for point wiring complete with stranded copper conductor 2.5 Sqmm single core (nominal area) PVC insulated and unsheathed cable 1100 volts grade drawn in existing conduit including single core stranded copper conductor connected PVC unsheathed cable 2.5 Sqmm as earth wire to the common earth and connecting to earth dolly all as specified for one 6 pin socket outlet two in one 16/6 amps on an independent board, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for circuit wiring with two single core 2.5 Sqmm stranded copper conductor PVC insulated and unsheathed cable ISI marked in PVC conduit heavy duty of dia 25mm fixed in wall/on surface or ceiling for sub main wiring alongwith including 2.5 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for circuit wiring with two single core 4 Sqmm stranded copper conductor PVC insulated and unsheathed cable ISI marked in PVC conduit heavy duty of dia 25mm fixed in wall/on surface or ceiling for sub main wiring alongwith including 4 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for circuit wiring with two single core 6 Sqmm stranded copper conductor PVC insulated and unsheathed cable ISI marked in PVC conduit heavy duty of dia 25mm fixed in wall/on surface or ceiling for sub main wiring alongwith including 6 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Casing and caping size 25mm x 16mm, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing uPVC conduit of size 25mm, FRLS, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing corrugated flexible pipe size 25mm, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 12 way type, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 8 way type, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 4 way type, complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, repair of fan motor and replacement of worn out parts such as bearing and hanging of ceiling fan/Exhaust fan in situ, complete all as specified and directed by Engineer-in-Charge. Note: (i) Rewinding of fan motor will be measured and paid separately.
Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling, complete all as specified and directed by Engineer-in-Charge.
Dismantling of Exhaust fan 250mm/300 mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement following items for maintenance of Internal Electrification, complete all as specified and directed by Engr-in-Charge.
Piano switch, flush type 5 Amps, 1 way.
Piano switch, flush type 5 Amps, 2 way.
Bell push, flush type 5 Amp.
Electric bell Ding Dong type, 230 Volts Single pole.
Switch socket combination, 6 Amps flush type.
Switch socket combination, 16 Amps flush type.
2.5 mfd Capacitor
Stepped type electronic fan regulator
Supply & Fixing in repair Modular switch 10 A, 1 way, 1 Module (ISI Marked), complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair Modular switch 16 A, 1 way, 1 Module (ISI Marked), complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair Modular socket 6/16 A, 2/3 pin combined , 2 Module (ISI Marked), complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair Modular socket 6 A, 2/3 pin combined , 2 Module (ISI Marked), complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair Modular Fan regulator 120W, 2 module (ISI Marked), complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair modular type 6A bell-push conforming to IS: 8884-1978 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair modular type 6 A two-way SP switch, conforming- to IS: 3854-1997 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair modular type bell ding dong of 2 module size, conforming to IS: 8884- 1978, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair of lamp holder PVC /polycarbonate type with back plate suitable for batten fitting, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair 6 A, 250 V high quality robust surface/ flush type polycarbonate/ PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5 mm, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in replacement top plug 5 Amp, complete all as specified and directed by Engineer-in-Charge. Make: Anchor or equivalent
Supply & Fixing in replacement top plug 15 Amp, complete all as specified and directed by Engineer-in-Charge. Make: Anchor or equivalent
Supply & Fixing in repair metal box 3 module including frame and plate, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair metal box 6 module including frame and plate, complete all as specified and directed by Engineer-in-Charge.
Comprehensive maintenance of RO Water Purifier 15 Ltr/Hr servicing in every 03 months by OEM rep and comprising of replacement of following:- (a) Filter (Sediment/Carbon Filter) (b) Over flow valve (c) Replacement of minor parts such as SP stem, union male elbow, branch etc deemed to be included in quoted rate (d) Major parts will be measured and paid separately Make : Kent ACE+ 7Litre RO+UF and Kent Elegant
Supply and fixing in replacement of following spares for RO water Purifier:-
Solenoid Valve
RO Membrane
UF Membrane
Pre-filter candle
Pre-filter box with candle
Supply and fixing pressure switch suiatable for booster pressure pump, complete all as specified and directed by Engineer-in-Charge.
Servicing, checking and testing of solar type water heater of capacity 100 KLD, watch for any signs of water leakage on the underside of the roof (if visible), check all nuts and bolts attaching the collectors to any support structures for tightness, watch for corrosion on steel parts and clean and paint if necessary, cleaning & scaling of storage tank & solar collector plate, checking and Flushing the Heat Transfer Fluid etc. at site and replacement of burnout parts etc. and refixing in situ, and verifying the overall system's performance, complete all as specified and directed by Engineer-in-Charge.
Repair and maintenance of LED light of strip type with complete wiring etc and verifying the overall system's performance, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement LED Power Supply 12V 25A 300W / SMPS / Profile Light Driver / Strip Light Driver complete and verifying the overall system's performance, complete all as specified and directed by Engineer-in-Charge.
Ravi enterprise (BID ID -3116086)
fakhrie apostrical (BID ID -3114291)
Indice Technologies (BID ID -3115674)
K K Construction Co (BID ID -3101877)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .