Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹34.7 L+₹2.6 L (8.14%)Rejected-AOC | L2 | Rejected-AOC Not being lowest bidder | |
| 3 | L3₹36.9 L+₹4.8 L (14.9%)Rejected-AOC | L3 | Rejected-AOC Not being lowest bidder | |
| 4 | L4₹40.4 L+₹8.3 L (25.9%)Rejected-AOC | L4 | Rejected-AOC Not being lowest bidder | |
| 5 | L5₹41.7 L+₹9.5 L (29.7%)Rejected-AOC | L5 | Rejected-AOC Not being lowest bidder |
Tender Value
₹40.5 L
EMD Value
₹81,000
Closing Date
26 Aug 2020, 6:00 pmClosed
GE I R nd D West Bengaluru
GARRISON ENGINEER I R nd D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
OUTSOURCING SERVICES FOR OPERATION AND MAINTENANCE OF HT/LT INSTALLATIONS AND UPKEEPING OF INTERNAL ELECTRIFICATION IN RESIDENTIAL AREA AT SERVICE CENTRE NO 3 AT DRDO COMPLEX PHASE - I, C V RAMAN NAGAR, BANGALORE
2020_MES_363443_1
GE(I) R ND D (WEST)/BAN/28 OF 2020-21 8825E8
Open Tender
Manpower Supply
Item Rate
330 days
GE I R nd D West Bengaluru
Class and Category as per NIT
8 documents required · 8 mandatory
₹500
GE I R nd D West Bengaluru
₹81,000
Yes
15 Sept 2020
29 Jul 2020
1 Sept 2020
30 Jul 2020
26 Aug 2020
14 Aug 2020
30 Jul 2020 - 13 Aug 2020
Amount
Providing services for maintenance, operation and up keeping of HT & LT installations, switch gears, RMU/SF6 / load break units, power controlled, transformers, OCBs and VCBs, OH lines 4 pole structures, GODs, DO fuses, street lights controls, LT panel boards installed in Sub-station No 3, including fuse off call on all days including Sundays & Holidays to maintain the equipments as detailed here-in-after and as directed by Engineer - in - Charge. The quoted rate shall deemed to include for the following :- NOTES : i) Manning and Operating round the clock in three shifts on all days including Sundays and Holidays . (0600 Hrs to 1400 Hrs - Ist Shft, 1400 Hrs to 2200 Hrs - 2nd shift & 2200 Hrs to 0600 Hrs - 3rd shift); Skilled Person - 1 No, and Helper -1 No per shift . All the above tasks shall be performed by skilled persons possessing the requisite qualifications and experience in handling HT/LT installations. ii) Cleaning of working areas, equipments, sub stations building and maintenance of garden areas. iii) Proper records of all operating parameters in the prescribed log book/register shall be maintained by the contractor in the installation for periodical check by the Engineer-in-charge.
iv) Tenderer shall arrange insurance to his work-men and relevant proofs of the same shall be submitted to the department as and when demanded, the cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of labour regulations in force lies with the tenderer. The provision of statutory laws relating to minimum wages, EPF, ESI payments shall be strictly adhered to by the contractor. The Contractor shall produce proof of wages, EPF and ESI paid against the respective workmen while claiming payments. v) Absent from duty of technician is not permissible as E&M services are essential in nature. However, the absence will invite penalty as described in Sch 'A' notes and recovery shall be done through recovery statement from the payment due. The tenderer will have no claim whatsoever on this account and decision of Accepting officer in this regard will be final and binding. (vi) Attention is drawn to minimum fair wages payable as notified (time to time) by Govt Of India / State Govt / Local body whichever is higher, including taxes as applicable and quote their rates accordingly. Contractor shall not have any claim on account of misunderstanding / under quoting in this regards.
Periodical checking and attending all types of complaints connected with internal electrification and maintenance of internal electrification comprising of periodical checking of power DBs including tightening of connections, changing of burnt-out terminals, MCBs, connectors etc., checking of earthing of the LT distribution system, periodical maintenance of earth pits including measurement of earth resistance, attending day-to-day complaints including checking and replacement of burnt-out and unserviceable items like wiring, connected fittings and fixtures, MCB DBs, ceiling fans, exhaust fans, replacement of tube rods of any wattage, choke, starters, point wiring, sub-main wiring, switch socket combination of any capacity, switches, fan regulators, capacitors, replacement of fuses, CFL bulbs, lamp holders etc., complete all as specified, in day time by deploying certified / skilled workers round the clock in Service center No. 3 and in fuse off call office, on all days including Sundays and holidays, complete all as specified and directed. NOTES - i) Manning and Operating in two shifts on all days including Sundays and Holidays (0600 Hrs to 1400 Hrs - Ist Shaft, 1400 Hrs to 2200 Hrs - 2nd shift) - 1 Electrician and 1 Helper per shift .All the above tasks shall be performed by skilled persons possessing the requisite qualifications. Contractor has to produce such certificate issued by the Government authorities to the Garrison Engineer for approval before commencement of work. ii) Tenderer shall arrange insurance to his work-men and relevant proofs of the same shall be submitted to the department as and when demanded, the cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of labour regulations in force lies with the tenderer. The provision of statutory laws relating to minimum wages, EPF, ESI payments shall be strictly adhered to by the contractor. The Contractor shall produce proof of payment of wages, EPF and ESI against the respective workmen while claiming payments, iii) Absent from duty of technician is not permissible as E&M services are essential in nature. However, the absence will invite penalty as described in Sch 'A' notes and recovery shall be done through recovery statement from payment due. The tenderer will have no claim whatsoever on this account and decision of Accepting officer in this regard will be final and binding.
Sl Item No 2 (Contd.,) :- (iv) Attention is drawn to minimum fair wages payable as notified (time to time) by Govt Of India / State Govt / Local body whichever is higher, including taxes as applicable and quote their rates accordingly. Contractor shall not have any claim on account of misunderstanding / under quoting in this regards.
Supply only PVC insulated, PVC unsheathed, multi-stranded heavy duty copper conductor cable of 1.5 sq.mm size, FR grade, complete all as specified and directed.
Supply only PVC insulated, PVC unsheathed, multi-stranded heavy duty copper conductor cable of 2.5 sq.mm size, FR grade, complete all as specified and directed.
Supply only PVC insulated, PVC unsheathed multi-stranded heavy duty copper conductor cable of 4.0 sq.mm size, FR grade, complete all as specified and directed.
Supply only PVC insulated, flexible copper cable, 23/0.0052, 3 core, 230 volts, complete all as specified and directed.
Supply only switch piano, flush type, 5/6 Amps single pole, 230 V, one way, complete all as specified and directed.
Supply only calling bell, ding-dong type, 230 V, single phase, complete all as specified and directed.
Supply only bell push, single pole, flush type, 230 V, 5 Amps, complete all as specified and directed.
Supply only socket, 3 & 2 pin, 5 A, 240 V, 50 Hz, flush type, complete all as specified and directed.
Supply only fan capacitor of 2.5 mfd for ceiling fan, single phase, 230 V, complete all as specified and directed.
Supply only fan capacitor of 4.0 mfd for ceiling fan, single phase, 230 V, complete all as specified and directed.
Supply only ceiling fan clamps for fixing of ceiling fans with rubber bushings, complete all as specified and directed.
Supply only tube light starter, 230 V, single phase, suitable for 20/40 W tube light fitting, complete all as specified and directed.
Supply only ceiling rose three terminals white bakelite type complete all as directed.
Supply only electronic choke 2 x 36 W for CFL fitting, 230V, complete all as specified and directed.
Supply only plug top, 3 pin, 15 Amps, 240 V, 50 Hz, complete all as specified and directed.
Supply only MCB, SP, 230 V, 6 to 32 Amps current rating, 'C' series, 10 KA breaking capacity, complete all as specified and directed.
Supply only MCB SPN, 230 V, 6 to 40 Amps current rating, 'C' series, 10 KA breaking capacity, complete all as specified and directed.
Supply only MCB, TPN, 415 V, 63 A, complete all as specified and directed.
Supply only MCB TP 100 Amps, 415 Volts, AC, 50 Hz, 240 V, 10 kA, breaking capacity, complete all as specified.
Supply only PVC casing/caping of 20mm size, complete all as specified and directed.
Supply only PVC casing/caping of 25 mm size, complete all as specified and directed.
Supply only fan regulator electronic type, 230 V, stepped type, 120 W complete all as specified and directed.
Supply only switch socket combination, 3 & 2 pin, 5 A, 240 V, flush type, multipurpose, controlled by one switch, complete all as specified and directed.
Supply only switch socket combination, 3 & 2 pin, 15 A, 240 V, flush type, multipurpose, controlled by one switch, complete all as specified and directed.
Supply only FTL tube rod 36 W / 40 W, 1220mm length (4'), complete all as specified and directed.
Supply only FTL tube rod 18 W / 20 W, 610mm length (2'), complete all as specified and directed.
Supply only LED bulb 9/11 W all as specified and as directed.
Supply only LED tube Rod, 18 Watt, suitable for existing FTL 40 W fittings, with high lumen output, environmental friendly, energy efficient LED, electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, complete as per Cat No CRYSTAL 1213T8DSTL18WLED865SGLASS of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply only, wall mounted LED tube light fitting with lamp, 9 Watt, 2 feet, with high lumen output, environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, complete with diffuser, polyester louver with 9 watt LED tube & integrated electronic driver 9 W fitting as per cat No LUMILINEBS9WLED865SPCWH of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply only, wall mounted LED tube light fitting with lamp, 18 Watt, 4 feet, with high lumen output, environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, complete with diffuser, polyester louver with 18 watt LED tube & integrated electronic driver 18 W fitting as per cat No LUMILINEBS18WLED865SPCWH of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply only rigid non metalic PVC conduit of size 25 mm dia medium grade ISI marked complete all as specified.
Supply only rigid non metalic PVC conduit of size 20 mm dia medium grade ISI marked complete all as specified.
Supply only, 25 W, LED security light fittings with lamp 25 W,with high lumen output, environmental friendly, energy efficient LED, with die cast aluminium body, with lamps and accessories, IP 20 protection, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, fittings made of powder coated housing, enclosed with glass cover in frame, connecting to loop boxes electrically, light fitting conforming to Cat No ENDURAPEARLSL25WLED 757SASYTOPCMP of Havells or techno commercially equivalent approved model complete with all accessories and lamp complete all specified and as directed . Note: i) Electric cable if required for replacing defective cable from looping box to fitting will be measured and paid separately under respective items. ii) Galvanised iron pipe of 40 mm dia, light grade bend to shape as brackets for fixing light fittings shall deemed to be included in quoted rate.
Supply only MCCB Three Pole, 63 Amps, 16KA breaking capacity, 415Volts all as specified.
Supply only MCCB four Pole, 63 Amps, 16 KA breaking capacity, 415Volts all as specified.
Supply only MCCB Three Pole, 125 Amps, 16 KA breaking capacity, 415Volts all as specified.
Supply only MCCB four Pole, 200 Amps, 35/36 KA breaking capacity, 415Volts all as specified.
Supply only Aluminium cable lugs suitable of XLPE cable of 10 to 35 sqmm size
Supply only Aluminium cable lugs suitable of XLPE cable of 50 to 95 sqmm size
Supply only, MCB DB SPN 8 way (Horizontal), double door with Sheet metal enclosure, flush mounted, prewired, 240 V, AC, 50 Hz, Factory made, powder coated, IP-42 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCB/ Isolators will be measured and paid separately as supply and fix under respecitve items.
Supply only, MCB DB SPN 4 way (Horizontal), double door with Sheet metal enclosure, flush mounted, prewired, 240 V, AC, 50 Hz, Factory made, powder coated, IP-42 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCB/ Isolators will be measured and paid separately as supply and fix under respecitve items.
Supply only, MCB DB SPN 12 way (Horizontal), double door with Sheet metal enclosure, flush mounted, prewired, 240 V, AC, 50 Hz, Factory made, powder coated, IP-43 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCB/ Isolators will be measured and paid separately as supply and fix under respecitve items.
Supply only, MCB DB VTPN 4 way (vertical), double door, with Sheet metal enclosure, flush mounted, prewired, 415 V, AC, 50 Hz, Factory made, powder coated, IP-43 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCB/ Isolators will be measured and paid separately as supply and fix under respecitve items.
Supply only Hot and Cold connection pipe 15/20mm dia 450mm long with couplers and washers on both sides of geysers as per Cat Part No F8070403 of CERA or tehcno commercial equivalent in ESS ESS / JAQUAR / HINDWARE / JOHNSON / MARC complete all as specified and as directed.
Disconnecting and removing the burnt cable end terminal at incoming of MCCB DB TPN / Cubicals, cutting suitable length of cable of incoming cable and adjusting cable from loop, preparing cable ends of any size, crimpling aluminium lugs of suitable size, connecting back with necessary bolts, nuts, washers, etc.,testing for any loose connections and making good the disturbed surfaces complete all as specified and as directed. Note: The rate shall deemed to include for making hole in masonry / concrete to draw cables from loop and making good the disturbed surface matching with the adjacent surfaces, complete as per directions of Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick burried directly in ground (earth pit not less than 2.25 m deep belopw ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in elecrtical plate 3, connected to earthing test point including excavation earth work PCC chamber RCC over 50mm thick with 8 mm dia bars, protection pipe, funnel, excavation, earth work, disposal of surplus soil to a distance not exceeding 50 m and earth wire and protection pipe of GI 15 mm bore light grade upto 7.5 metre including testing on completion all as specified and directed.
M/S Anu Enterprises
Arunachaleswara enterprises
kamadhenu Electricals
Auromirra Enterprises
Solar Electricals and Electronics
M/S Sneha Enterprises
B5BUILDING SOLUTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .