Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAccepted-AOC BYPASS ROAD BESIDE YUG BAJAJ SHOWROOM GARIBICHOK PORBANDAR 360577 | PORBANDAR | GUJARAT | 360577 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹44.9 L+₹4.6 L (11.3%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹44.9 L+₹4.6 L (11.4%)Rejected-Finance PLOT NO P PARASNAGAR NR SBI BANK NARSANG TEKRI PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹49.2 L+₹8.9 L (22.0%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹49.7 L+₹9.4 L (23.2%)Rejected-Finance HQ CE SC PUNE | PUNE | MAHARASHTRA | 410301 | L5 | Rejected-Finance Being L5 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
12 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I CG PORBANDAR
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
PROVN OF RAIN WATER HARVESTING SYSTEM AT INAZ VILLAGE, UNDER GE (I) CG PORBANDAR
2023_MES_620151_1
8870
Open Tender
Civil Works
Item Rate
180 days
INAZ VILLAGE
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE I CG PORBANDAR
₹88,000
Yes
30 Nov 2023
22 Sept 2023
14 Oct 2023
22 Sept 2023
12 Oct 2023
7 Oct 2023
Amount
SCHEDULE 'A'
Material & Labour for excavating over areas exceeding 1.5 Metre depth and getting out soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
ditto-as item No. 1 but depth exceeding 1.5 Metre and not exceeding 3.0 Metre and getting out in soft/disintegrated rock, complete all as specified and directed by Engineer-in-Charge.
ditto-as item No. 1 but depth exceeding 3.0 Metre and not exceeding 4.50 Metre and getting out in soft/disintegrated rock, complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceed 1.5 Metre wide and not exceed 1.5 Metre in depth for foundation etc., not exceed 10 Sqm on plan and not exceed 1.5 Metre in depth and getting out in soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
Returning filling in, including spreading leveling, watering and well ramming in layer not exceed 25 cm in soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
Removing excavated soft rock exceeding 500 Metre but not exceeding 1.50 Km and depositing outside MoD land where directed, complete all as specified and directed by Engineer-in-Charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Material & Labour for Cement concrete type D-2, 1:4:8 using 40mm graded aggregate as in foundations, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Cement concrete type C-2, 1:3:6 (using 40mm graded aggregate) as in foundations, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for plain cement concrete type B-0, 1:2:4 (using 12.50 mm graded aggregate) as in copings, kneelers, apex stones, bed plates, kerbs, surface channels, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for precast concrete block masonry with solid block not exceeding 20 cm width type C-1, 1:3:6 setting in cement mortar (1:6), complete all as specified and directed by Engineer-in-Charge.
Material & Labour for RCC (design mix) M-30 (20mm graded aggregates) in foundation, including rafts, basement slabs, foundation beams and the like, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for RCC (design mix) M-30 (20mm graded aggregates) in walls,basement walls any thickness above top of footing; including attached pilasters and buttresses, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for RCC (design mix) M-30 (20mm graded aggregates) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for RCC (design mix) M-30 (20mm graded aggregates) in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for RCC (design mix) M-30 (20mm graded aggregates) in columns, pillars, piers, posts and struts, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Extra for forming fair finished drain or channel 60 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for pebbles, gravels and sand mix below foundations, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Loose filling with broken stone or boulder aggregates of guage 10 mm to 20 mm in silt chamber etc, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Loose filling with broken stone or boulder aggregates of guage 40 mm to 80 mm in silt chamber etc, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for hardcore of guage of broken stone boulders, exceeding 63mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rolled/rammed to a true surface, complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter to get rough finished curved surfaces of concrete, complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter to get rough finished flat surfaces of concrete, complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railing and similar works including attached pilasters, butresses etc; vertical or to batter, to get rough finished curved surfaces of concrete, complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railing and similar works including attached pilasters, butresses etc; vertical or to batter, to get rough finished flat surfaces of concrete, complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work n exc 200mm thick rough finished flat surfaces of concrete, complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to sides and soffits of beam for rough finished flat surfaces of concrete, complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions of square, rectangular or polygonal shape to get rough finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail?ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon?tal or sloping and similar work exc 10cm but n exc 20cm width to get rough finished flat concrete surfaces, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for framed work such as grils, gratings, etc, with ends of bar shouldered and/ or riveted or forged into spikes framed guard bars barred iron doors ladders framework of waretanks and similar work confirming to Fe. 290 Gde 165, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Bands, straps, supports or stays for rain water, ventilating pipes, incl bolts, if required; hooks(stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; holdfasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar articles conforming to Fe 290 Gde E-165, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for CRS TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge.
All as per item No.31 here-in-before but 6mm to 8mm dia CRS TMT bar, complete all as specified and directed by Engineer-in-Charge.
All as per item No.31 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Plates (plain or chequered) channels, squares cut or notched (ordinary and counter sunk) forming holes, without any attachment, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering 10mm thick on fair faces of brick work or concrete external wall surfaces in Cement Mortar 1:4 finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering 10mm thick on fair faces of brick work or concrete wall surfaces in Cement Mortar 1:3 finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering 10mm thick on fair faces of brick work or concrete wall surfaces in Cement Mortar 1:6 finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering 5mm thick on fair faces of brick work or concrete ceiling surfaces in Cement Mortar 1:3 finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of zinc chrome primer, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing VFB Balloon made of metal mesh to capture floating impurities and 5 filter medias on perforated lid, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing VESS 06-01 Nee Rain plus non Clogging SS filter with flat end having 150 mm dia and 500 mm length, 0.50 mm slot with integrated flange , rubber washer, bolts, PVC fitting, threaded flange, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing PVC (SWR) pipes 150 mm dia single socketed in any length with rubber joints fixed to walls, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing PVC (SWR) bends any radius 150mm dia, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Reaming of 525 mm trial bore below waste slab of recharge pit upto 60 m depth and pea gravel around the slotted pipes in any type of soil strata, excluding casing pipes, complete all as specified and directed by Engineer-in-Charge. Note: 200 mm dia 8 mm thickness slotted PVC pipes shall be measured and paid separately.
Supply and laying 200 mm dia 8 mm wall thickness slotted PVC pipes as in trenches/ bore wells as casing pipe for recharging the water table, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Cement concrete bed to drain pipes of 300mm dia (1:3:6) type C2 using 40mm graded aggregate including packing under and haunching against sides of pipes after they are laid and tested, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 300mm bore RCC pipes class NP2 laid and jointed complete with collars, complete all as specified and directed by Engineer-in-Charge.
Cutting into existing drain for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 75mm thick plain cement concrete B-2, 1:2:4 (using 40mm graded crushed stone aggregate) as in plinth protection finished fair and even without using extra cement complete all as specified and directed by Engineer-in-Charge. Note:- The plinth protection shall be laid in pannels and length of the each panel shall not be more than 2.00 mtr all as directed. 6mm joints filled with 85/25 grade bitumen and sand (1:3 ratio) shall be provided. No deduction for joints shall be made while making payment against the above item, complete all as specified and directed.
Supply and laying of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 16 Sqmm 4 Core laid in trenches/along the wall/pole including making good the disturbed surfaces of walls/floor etc. all connections complete all as specified and directed by Engineer-in-Charge. MAKE:- Havells/ RR Kabel / polycab
Supply & Fixing of GI steel tubing light grade 50 mm dia for laying in ground and road crossing along the pole in coping etc. for cable protection including necessary fittings, clamps for supports, etc., including making good the disturbed surfaces of walls/floor etc., complete all as specified and directed by Engineer-in-Charge. Make - Tata/Jindal/Surya Prakash
Supply and laying 50 /38 mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches/ road/ drain or fixed along wall, poles or laid under floor complete all as specified and directed by Engineer-in-Charge. Make:- Rex/ Poly/ Gemini
Material & Labour for LT panel Board cubical KIOSK outdoor type compact 415 Volts AC 50 Hz, 4 wire +E, factory made, outdoor type, dust and vermin proof cubical type, LT panel fabricated from 3.15 mm thick ( minimum) CRCA sheet with epoxy polyester powder coating of flint Grey shade (RAL-7032) finish confirming to IP 54 complete including Copper bus bar 100 Amps, 30 KA, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry comprising of following :- (a) Incoming MCCB 40 Amps 4 pole with microprocessor based release having breaking capacity 36 KA - 01 Nos. (b) Outgoing MCB 32 Amps 415 V, Triple Pole, 36KA - 02 Nos. (c) Outgoing MCB 32 Amps SPN - 01 No. (d) DOL starter 10 HP - 02 Nos (e) Digital Voltmeter 0-500 V 96x96xm - 01 No (f) Digital Ammeter 0 - 500 A 96x96m - 01 No (g) Indicating lamps set RYB - 01 set. (h) Panel mounted type digital multifunctional energy meter, CT operated, LT 3 phase, 4 wire, including ct ratio 200/5 - 01 Nos. Make:- BCH / C &S / ADVANCE / L&T
Material & Labour for Earthing complete with Copper plate electrode 60×60cm ×3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to Copper earth Strip 20 x 3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and directed by Engineer-in-Charge.
Supply and laying 3- layer PP-R Polypropylene random copolymer of size 90 mm Dia concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches including fittings complete all as specified and directed by Engineer-in-Charge. MAKE:- SFMC /AKG /SFC / RELIANCE
Supply and laying 3- layer PP-R Polypropylene random copolymer of size 75 mm Dia concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches including fittings complete all as specified and directed by Engineer-in-Charge. MAKE:- SFMC /AKG /SFC / RELIANCE
Supply and laying 3- layer PP-R Polypropylene random copolymer of size 63 mm Dia concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches including fittings complete all as specified and directed by Engineer-in-Charge. MAKE:- SFMC /AKG /SFC / RELIANCE
Supply and fixing PP-R Gate valves (brass insert) as per requirement of the site of Size of 75/63mm bore complete all as specified and directed by Engineer-in-Charge. MAKE:- SFMC /AKG /SFC / RELIANCE
Supply, install, testing & commissioning of Monoblock pump set suitable for 415 V, 3 phase, system having capacity 7.5 HP complete with foundation and connected accessories including support of base plate and fixed with suitable bolts, grouted in PCC foundation etc., complete all as specified and directed by Engineer-in-Charge. MAKE:- KIRLOSKAR / CROMPTON
Material & Labour for weather proof flexible three core 6 Sqmm x 3 Core flat cables copper counductor insulated with PVC sheathed for submersible pump motor with voltage grade up to 1100 including proper lugs, drawn through rigid non-metallic PVC conduit of size 25 mm dia inclusive of all tees, bends, elbows, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for interconnection of cable light/looping box to light etc. complete all as specified and directed by Engineer-in-Charge. Make :- Polycab /Plaza /Havells
Material & Labour for Construction of valve pit chamber of follwing sizes with brick massonary, one brick thick wall in cement mortor (1:4) on 100 mm thick PCC 1:4:8 type D-2 (using 40mm graded aggregate) as in foundation, 15 mm thick cement & plaster rendering internally all arround over brick work & externally upto 15cm below normal GL with 10 SWG thick MS sheet cover including 40 x 40 x 6mm MS angle frame fixed locking arrangement and painting with one coat of red oxide and two coats of black Bituminous paints of size 1000 mm x 1000 mm x 900mm, complete all as specified and directed by Engineer-in-Charge.
Commercial Electric Co.
AADESH CONSTRUCTION
Vijay Construction Co
K B N TRADERS
SANVI ASSOCIATES
shree chamunda enterprise
K K Construction Co
JAY BHARAT METAL SUPPLIERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .